-
Muonic atom spectroscopy with microgram target material
Authors:
A. Adamczak,
A. Antognini,
N. Berger,
T. E. Cocolios,
N. Deokar,
Ch. E. Düllmann,
A. Eggenberger,
R. Eichler,
M. Heines,
H. Hess,
P. Indelicato,
K. Kirch,
A. Knecht,
J. J. Krauth,
J. Nuber,
A. Ouf,
A. Papa,
R. Pohl,
E. Rapisarda,
P. Reiter,
N. Ritjoho,
S. Roccia,
M. Seidlitz,
N. Severijns,
K. von Schoeler
, et al. (4 additional authors not shown)
Abstract:
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However,…
▽ More
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100-bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5-μg gold target.
△ Less
Submitted 2 June, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.
-
Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique
Authors:
Sayani Biswas,
Lars Gerchow,
Hubertus Luetkens,
Thomas Prokscha,
Aldo Antognini,
Niklaus Berger,
Thomas Elias Cocolios,
Rugard Dressler,
Paul Indelicato,
Klaus Jungmann,
Klaus Kirch,
Andreas Knecht,
Angela Papa,
Randolf Pohl,
Maxim Pospelov,
Elisa Rapisarda,
Peter Reiter,
Narongrit Ritjoho,
Stephanie Roccia,
Nathal Severijns,
Alexander Skawran,
Stergiani Marina Vogiatzi,
Frederik Wauters,
Lorenz Willmann,
Alex Amato
Abstract:
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the avail…
▽ More
The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Study of nuclear properties with muonic atoms
Authors:
A. Knecht,
A. Skawran,
S. M. Vogiatzi
Abstract:
Muons are a fascinating probe to study nuclear properties. Muonic atoms can easily be formed by stopping negative muons inside a material. The muon is subsequently captured by the nucleus and, due to its much higher mass compared to the electron, orbits the nucleus at very small distances. During this atomic capture process the muon emits characteristic X-rays during its cascade down to the ground…
▽ More
Muons are a fascinating probe to study nuclear properties. Muonic atoms can easily be formed by stopping negative muons inside a material. The muon is subsequently captured by the nucleus and, due to its much higher mass compared to the electron, orbits the nucleus at very small distances. During this atomic capture process the muon emits characteristic X-rays during its cascade down to the ground state. The energies of these X-rays reveal the muonic energy level scheme, from which properties like the nuclear charge radius or its quadrupole moment can be extracted. While almost all stable elements have been examined using muons, probing highly radioactive atoms has so far not been possible. The muX experiment has developed a technique based on transfer reaction inside a high pressure hydrogen/deuterium gas cell to examine targets available only in microgram quantities.
△ Less
Submitted 7 April, 2020;
originally announced April 2020.
-
The measurement of the quadrupole moment of 185-Re and 187-Re from the hyperfine structure of muonic X rays
Authors:
A. Antognini,
N. Berger,
T. E. Cocolios,
R. Dressler,
R. Eichler,
A. Eggenberger,
P. Indelicato,
K. -P. Jungmann,
C. H. Keitel,
K. Kirch,
A. Knecht,
N. Michel,
J. Nuber,
N. S. Oreshkina,
A. Ouf,
A. Papa,
R. Pohl,
M. Pospelov,
E. Rapisarda,
N. Ritjoho,
S. Roccia,
N. Severijns,
A. Skawran,
S. M. Vogiatzi,
F. Wauters
, et al. (1 additional authors not shown)
Abstract:
The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values…
▽ More
The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values of the nuclear spectroscopic quadrupole moment are 2.07(5) barn and 1.94(5) barn, respectively for 185-Re and 187-Re. This work is part of a larger effort at the Paul Scherrer Institut towards the measurement of the nuclear charge radii of radioactive elements.
△ Less
Submitted 5 March, 2020;
originally announced March 2020.