Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm
Authors:
Adnan Rashid,
Sebastian M. Waldstein,
Bianca S. Gerendas,
Hrvoje Bogunovic,
Andreas Wahle,
Kyungmoo Lee,
Kai Wang,
Christian Simader,
Michael D. Abramoff,
Ursula Schmidt-Erfurth,
Milan Sonka
Abstract:
PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measureme…
▽ More
PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measurement across devices. PARTICIPANTS: 55 Fovea-centered Spectral-Domain Optical Coherence Tomography volumes from eleven subjects were analyzed, obtained from Cirrus HD-OCT, RS-3000, Heidelberg Spectralis, RTVue and Topcon2000, seven subjects with retinal diseases and four normal controls. METHOD: The Iowa Reference Algorithm measured total retinal thickness. Nonlinear model of total retinal thickness measurement comparisons was derived and used for device-specific comparisons. Bland-Altman plots and pairwise predictive equations yielded pairwise scanner-specific differences. Mendel test determined whether measurement biases were constant for each scanner pair. RESULTS: Mendel test revealed that all pairwise scanner differences of total retinal thickness were constant across the cohort (p=0.992). Individual measurements can thus be bias-corrected and the Iowa Reference Algorithm serve as a scanner-agnostic independent standard of total retinal thickness across the five tested SD-OCT scanners. CONCLUSIONS: Combination of the Iowa Reference Algorithm with scanner-specific bias correction yields cross-scanner consistency of total retinal thickness measurements, facilitating scanning-device independent quantitative assessment of total retinal thickness, longitudinal follow-up quantification without requiring patients to be imaged on the same scanner model, and allowing for multi-center studies with heterogeneous device utilization when using the Iowa Reference Algorithm.
△ Less
Submitted 19 December, 2016;
originally announced December 2016.