Real-time fetAl brain and placental T2* mapping at 0.55T low-field MRI (RAT)
Authors:
Jordina Aviles Verdera,
Sara Neves Silva,
Raphael Tomi-Tricot,
Megan Hall,
Lisa Story,
Shaihan J Malik,
Joseph V Hajnal,
Mary A Rutherford,
Jana Hutter
Abstract:
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 da…
▽ More
Purpose: To provide real-time quantitative organ-specific information - specifically placental and brain T2* - to allow optimization of the MR examination to the individual patient.
Methods: A FIRE-based real-time setup segmenting placenta and fetal brain in real-time, performing T2* fitting and analysis and calculation of the centile was implemented. A nn-UNet were trained and tested on 2989 datasets for the fetal brain and a second one trained on 210 datasets for the placenta for automatic segmentation. T2* normal curves were obtained from 106 cases and prospective evaluation was performed on 10 cases between 35 and 39 weeks GA.
Results: Quantitative brain and placental T2* maps and centiles were available in all prospective cases within 30 seconds. The robustness of the method was shown with intra-scan repeats (mean difference 1.04+/-12.39 ms for fetal brain and -3.15+/-8.88 ms for placenta) and direct validation with vendor-processed offline results (mean difference 1.62+/-4.33 ms for fetal brain and 0.16+/-6.19 ms for placenta).
Discussion and Conclusion: Real-time available organ-specific quantitative information enables more personalized MR examinations, selection of the most pertinent sequences and thus the promise of reduced recalls and specific insights into tissue properties. The here enabled placental T2*, demonstrated in multiple recent studies to be a biomarker sensitive to a range of pregnancy complications, and fetal brain T2* will be explored in further studies in pregnancies with pre-eclampsia, growth restriction as a way of enabling future MR-guided fetal interventions.
△ Less
Submitted 25 September, 2024;
originally announced September 2024.
-
AutOmatic floW planning for fetaL MRI (OWL)
Authors:
Sara Neves Silva,
Tomas Woodgate,
Sarah McElroy,
Michela Cleri,
Kamilah St Clair,
Jordina Aviles Verdera,
Kelly Payette,
Alena Uus,
Lisa Story,
David Lloyd,
Mary A Rutherford,
Joseph V Hajnal,
Kuberan Pushparajah,
Jana Hutter
Abstract:
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landm…
▽ More
Two subsequent deep learning networks, one localizing the fetal chest and one identifying a set of landmarks on a coronal whole-uterus balanced steady-state free precession scan, were trained on 167 and 71 fetal datasets across field strengths, acquisition parameters, and gestational ages and implemented in a real-time setup. Next, a phase-contrast sequence was modified to use the identified landmarks for planning. The OWL pipeline was evaluated retrospectively in 10 datasets and prospectively in 7 fetal subjects (gestational ages between 36+3 and 39+3 weeks). The prospective cases were additionally manually planned to enable direct comparison both qualitatively, by scoring the planning quality, and quantitatively, by comparing the indexed flow measurements. OWL enabled real-time fully automatic planning of the 2D phase-contrast scans in all but one of the prospective participants. The fetal body localization achieved an overall Dice score of 0.94+-0.05 and the cardiac landmark detection accuracy was 5.77+-2.91 mm for the descending aorta, 4.32+-2.44 mm for the spine, and 4.94+-3.82 mm for the umbilical vein. For the prospective cases, overall planning quality was 2.73/4 for the automated scans, compared to 3.0/4 for manual planning, and the flow quantitative evaluation showed a mean difference of -1.8% (range -14.2% to 14.9%) by comparing the indexed flow measurements obtained from gated automatic and manual acquisitions. Real-time automated planning of 2D phase-contrast MRI was effectively accomplished for 2 major vessels of the fetal vasculature. While demonstrated here on 0.55T, the achieved method has wider implications, and training across multiple field strengths enables generalization. OWL thereby presents an important step towards extending access to this modality beyond specialised centres.
△ Less
Submitted 12 August, 2024;
originally announced August 2024.
-
Fully automated planning for anatomical fetal brain MRI on 0.55T
Authors:
Sara Neves Silva,
Sarah McElroy,
Jordina Aviles Verdera,
Kathleen Colford,
Kamilah St Clair,
Raphael Tomi-Tricot,
Alena Uus,
Valery Ozenne,
Megan Hall,
Lisa Story,
Kuberan Pushparajah,
Mary A Rutherford,
Joseph V Hajnal,
Jana Hutter
Abstract:
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from…
▽ More
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. Comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality and the resulting image quality was conducted. Results: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.21+-2.56 mm for the fetal eyes and 6.47+-3.23 for the cerebellum, planning quality was 2.44/3 (compared to 2.56/3 for manual planning) and diagnostic image quality was 2.14 compared to 2.07 for manual planning. Conclusions: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way towards simplifying the acquisition of fetal MRI thereby widening the availability of this modality in non-specialist centres.
△ Less
Submitted 18 January, 2024;
originally announced January 2024.
-
Proposal of a Takagi-Sugeno Fuzzy-PI Controller Hardware
Authors:
Sérgio N. Silva,
Felipe F. Lopes,
Carlos Valderrama,
Marcelo A. C. Fernandes
Abstract:
This work proposes dedicated hardware for an intelligent control system on Field Programmable Gate Array (FPGA). The intelligent system is represented as Takagi-Sugeno Fuzzy-PI controller. The implementation uses a fully parallel strategy associated with a hybrid bit format scheme (fixed-point and other floating-point). Two hardware designs are proposed; the first one uses a single clock cycle pro…
▽ More
This work proposes dedicated hardware for an intelligent control system on Field Programmable Gate Array (FPGA). The intelligent system is represented as Takagi-Sugeno Fuzzy-PI controller. The implementation uses a fully parallel strategy associated with a hybrid bit format scheme (fixed-point and other floating-point). Two hardware designs are proposed; the first one uses a single clock cycle processing architecture, and the other uses a pipeline scheme. The bit accuracy was tested by simulation with a non linear control system of a robotic manipulator. The area, throughput, and dynamic power consumption of the implemented hardware are used to validate and compare the results of this proposal. The results achieved allow that the proposal hardware can use in several applications with high-throughput, low-power and ultra-low-latency restrictions such as teleportation of robot manipulators, tactile internet, industrial automation in industry 4.0, and others.
△ Less
Submitted 12 March, 2020;
originally announced March 2020.