-
Minimum quantum run-time characterization and calibration via restless measurements with dynamic repetition rates
Authors:
Caroline Tornow,
Naoki Kanazawa,
William E. Shanks,
Daniel J. Egger
Abstract:
The performance of a quantum processor depends on the characteristics of the device and the quality of the control pulses. Characterizing cloud-based quantum computers and calibrating the pulses that control them is necessary for high-fidelity operations. However, this time intensive task eats into the availability of the device. Here, we show restless measurements with a dynamic repetition rate t…
▽ More
The performance of a quantum processor depends on the characteristics of the device and the quality of the control pulses. Characterizing cloud-based quantum computers and calibrating the pulses that control them is necessary for high-fidelity operations. However, this time intensive task eats into the availability of the device. Here, we show restless measurements with a dynamic repetition rate that speed-up calibration and characterization tasks. Randomized benchmarking is performed 5.3 times faster on the quantum device than when an active reset is used and without discarding any data. In addition, we calibrate a qubit with parameter scans and error-amplifying gate sequences and show speed-ups of up to a factor of forty on the quantum device over active reset. Finally, we present a methodology to perform restless quantum process tomography that mitigates restless state preparation errors. These results reduce the footprint of characterization and calibration tasks. Quantum computers can thus either spend more time running applications or run calibrations more often to maintain gate fidelity.
△ Less
Submitted 15 August, 2022; v1 submitted 14 February, 2022;
originally announced February 2022.
-
Imaging Photon Lattice States by Scanning Defect Microscopy
Authors:
D. L. Underwood,
W. E. Shanks,
Andy C. Y. Li,
Lamia Ateshian,
Jens Koch,
A. A. Houck
Abstract:
Microwave photons inside lattices of coupled resonators and superconducting qubits can exhibit surprising matter-like behavior. Realizing such open-system quantum simulators presents an experimental challenge and requires new tools and measurement techniques. Here, we introduce Scanning Defect Microscopy as one such tool and illustrate its use in mapping the normal-mode structure of microwave phot…
▽ More
Microwave photons inside lattices of coupled resonators and superconducting qubits can exhibit surprising matter-like behavior. Realizing such open-system quantum simulators presents an experimental challenge and requires new tools and measurement techniques. Here, we introduce Scanning Defect Microscopy as one such tool and illustrate its use in mapping the normal-mode structure of microwave photons inside a 49-site Kagome lattice of coplanar waveguide resonators. Scanning is accomplished by moving a probe equipped with a sapphire tip across the lattice. This locally perturbs resonator frequencies and induces shifts of the lattice resonance frequencies which we determine by measuring the transmission spectrum. From the magnitude of mode shifts we can reconstruct photon field amplitudes at each lattice site and thus create spatial images of the photon-lattice normal modes.
△ Less
Submitted 28 October, 2015;
originally announced October 2015.
-
A scanning transmon qubit for strong coupling circuit quantum electrodynamics
Authors:
William E. Shanks,
Devin L. Underwood,
Andrew A. Houck
Abstract:
Like a quantum computer designed for a particular class of problems, a quantum simulator enables quantitative modeling of quantum systems that is computationally intractable with a classical computer. Quantum simulations of quantum many-body systems have been performed using ultracold atoms and trapped ions among other systems. Superconducting circuits have recently been investigated as an alterna…
▽ More
Like a quantum computer designed for a particular class of problems, a quantum simulator enables quantitative modeling of quantum systems that is computationally intractable with a classical computer. Quantum simulations of quantum many-body systems have been performed using ultracold atoms and trapped ions among other systems. Superconducting circuits have recently been investigated as an alternative system in which microwave photons confined to a lattice of coupled resonators act as the particles under study with qubits coupled to the resonators producing effective photon-photon interactions. Such a system promises insight into the nonequilibrium physics of interacting bosons but new tools are needed to understand this complex behavior. Here we demonstrate the operation of a scanning transmon qubit and propose its use as a local probe of photon number within a superconducting resonator lattice. We map the coupling strength of the qubit to a resonator on a separate chip and show that the system reaches the strong coupling regime over a wide scanning area.
△ Less
Submitted 4 March, 2013;
originally announced March 2013.
-
Measurement of the full distribution of the persistent current in normal-metal rings
Authors:
M. A. Castellanos-Beltran,
D. Q. Ngo,
W. E. Shanks,
A. B. Jayich,
J. G. E. Harris
Abstract:
We have measured the persistent current in individual normal metal rings over a wide range of magnetic fields. From this data, we extract the first six cumulants of the single-ring persistent current distribution. Our results are consistent with the theoretical prediction that this distribution should be nearly Gaussian (i.e., that these cumulants should be nearly zero) for diffusive metallic ring…
▽ More
We have measured the persistent current in individual normal metal rings over a wide range of magnetic fields. From this data, we extract the first six cumulants of the single-ring persistent current distribution. Our results are consistent with the theoretical prediction that this distribution should be nearly Gaussian (i.e., that these cumulants should be nearly zero) for diffusive metallic rings. This measurement highlights the particular sensitivity of persistent current to the mesoscopic fluctuations within a single coherent volume.
△ Less
Submitted 21 January, 2013; v1 submitted 17 April, 2012;
originally announced April 2012.
-
Low-Disorder Microwave Cavity Lattices for Quantum Simulation with Photons
Authors:
Devin L. Underwood,
Will E. Shanks,
Jens Koch,
Andrew A. Houck
Abstract:
We assess experimentally the suitability of coupled transmission line resonators for studies of quantum phase transitions of light. We have measured devices with low photon hopping rates t/2pi = 0.8MHz to quantify disorder in individual cavity frequencies. The observed disorder is consistent with small imperfections in fabrication. We studied the dependence of the disorder on transmission line geo…
▽ More
We assess experimentally the suitability of coupled transmission line resonators for studies of quantum phase transitions of light. We have measured devices with low photon hopping rates t/2pi = 0.8MHz to quantify disorder in individual cavity frequencies. The observed disorder is consistent with small imperfections in fabrication. We studied the dependence of the disorder on transmission line geometry and used our results to fabricate devices with disorder less than two parts in 10^4. The normal mode spectrum of devices with a high photon hopping rate t/2pi = 31MHz shows little effect of disorder, rendering resonator arrays a good backbone for the study of condensed matter physics with photons.
△ Less
Submitted 24 October, 2012; v1 submitted 23 March, 2012;
originally announced March 2012.
-
Persistent Currents in Normal Metal Rings (Yale PhD thesis)
Authors:
William E. Shanks
Abstract:
In this work, I present measurements of persistent currents in normal metal rings performed with cantilever torsional magnetometry. With this technique, the typical persistent current (the component that varies randomly from ring to ring) was measured with high sensitivity. I report measured magnitudes as low as 1 pA, over two orders of magnitude smaller than that observed in previous studies. The…
▽ More
In this work, I present measurements of persistent currents in normal metal rings performed with cantilever torsional magnetometry. With this technique, the typical persistent current (the component that varies randomly from ring to ring) was measured with high sensitivity. I report measured magnitudes as low as 1 pA, over two orders of magnitude smaller than that observed in previous studies. These measurements extend the range of temperature and magnetic field over which the typical current has been observed. The wide magnetic field range allowed us to study the effect of magnetic field penetrating the ring. It also enabled the recording of many independent measurements of the current magnitude in a single sample. These independent measurements are necessary to characterize the persistent current magnitude because it is a random quantity. From these measurements of the persistent current, I also characterize the parametric dependence of the typical current on sample orientation and number of rings. In addition to presenting the experimental results, I thoroughly review the theory of the typical persistent current in the diffusive regime. I begin with the simplest model and build up to the case appropriate for the samples studied in our experiments. I also present in detail the experimental apparatus used to measure the persistent currents.
△ Less
Submitted 14 December, 2011;
originally announced December 2011.
-
Mesoscopic persistent currents in a strong magnetic field
Authors:
Eran Ginossar,
Leonid I. Glazman,
Teemu Ojanen,
Felix von Oppen,
William E. Shanks,
Ania C. Bleszynski-Jayich,
J. G. E. Harris
Abstract:
Recent precision measurements of mesoscopic persistent currents in normal-metal rings rely on the interaction between the magnetic moment generated by the current and a large applied magnetic field. Motivated by this technique, we extend the theory of mesoscopic persistent currents to include the effect of the finite thickness of the ring and the resulting penetration of the large magnetic field…
▽ More
Recent precision measurements of mesoscopic persistent currents in normal-metal rings rely on the interaction between the magnetic moment generated by the current and a large applied magnetic field. Motivated by this technique, we extend the theory of mesoscopic persistent currents to include the effect of the finite thickness of the ring and the resulting penetration of the large magnetic field. We discuss both the sample-specific typical current and the ensemble-averaged current which is dominated by the effects of electron-electron interactions. We find that the magnetic field strongly suppresses the interaction-induced persistent current and so provides direct access to the independent-electron contribution. Moreover, the technique allows for measurements of the entire distribution function of the persistent current. We also discuss the consequences of the Zeeman splitting and spin-orbit scattering, and include a detailed and quantitative comparison of our theoretical results to experimental data.
△ Less
Submitted 3 February, 2010;
originally announced February 2010.
-
Persistent currents in normal metal rings: comparing high-precision experiment with theory
Authors:
A. C. Bleszynski-Jayich,
W. E. Shanks,
B. Peaudecerf,
E. Ginossar,
F. von Oppen,
L. Glazman,
J. G. E. Harris
Abstract:
Quantum mechanics predicts that the equilibrium state of a resistive electrical circuit contains a dissipationless current. This persistent current has been the focus of considerable theoretical and experimental work, but its basic properties remain a topic of controversy. The main experimental challenges in studying persistent currents have been the small signals they produce and their exceptio…
▽ More
Quantum mechanics predicts that the equilibrium state of a resistive electrical circuit contains a dissipationless current. This persistent current has been the focus of considerable theoretical and experimental work, but its basic properties remain a topic of controversy. The main experimental challenges in studying persistent currents have been the small signals they produce and their exceptional sensitivity to their environment. To address these issues we have developed a new technique for detecting persistent currents which offers greatly improved sensitivity and reduced measurement back action. This allows us to measure the persistent current in metal rings over a wider range of temperature, ring size, and magnetic field than has been possible previously. We find that measurements of both a single ring and arrays of rings agree well with calculations based on a model of non-interacting electrons.
△ Less
Submitted 25 June, 2009;
originally announced June 2009.
-
High quality mechanical and optical properties of commercial silicon nitride membranes
Authors:
B. M. Zwickl,
W. E. Shanks,
A. M. Jayich,
C. Yang,
A. C. Bleszynski Jayich,
J. D. Thompson,
J. G. E. Harris
Abstract:
We have measured the optical and mechanical loss of commercial silicon nitride membranes. We find that 50 nm-thick, 1 mm^2 membranes have mechanical Q > 10^6 at 293 K, and Q > 10^7 at 300 mK, well above what has been observed in devices with comparable dimensions. The near-IR optical loss at 293 K is less than 2E-4. This combination of properties make these membranes attractive candidates for st…
▽ More
We have measured the optical and mechanical loss of commercial silicon nitride membranes. We find that 50 nm-thick, 1 mm^2 membranes have mechanical Q > 10^6 at 293 K, and Q > 10^7 at 300 mK, well above what has been observed in devices with comparable dimensions. The near-IR optical loss at 293 K is less than 2E-4. This combination of properties make these membranes attractive candidates for studying quantum effects in optomechanical systems.
△ Less
Submitted 14 November, 2007;
originally announced November 2007.
-
High sensitivity cantilevers for measuring persistent currents in normal metal rings
Authors:
Ania C. Bleszynski Jayich,
Will E. Shanks,
Rob Ilic,
J. G. E. Harris
Abstract:
We propose a new approach to measuring persistent currents in normal metal rings. By integrating micron-scale metal rings into sensitive micromechanical cantilevers and using the cantilevers as torque magnetometers, it should be possible to measure the rings' persistent currents with greater sensitivity than the SQUID-based and microwave resonator-based detectors used in the past. In addition, c…
▽ More
We propose a new approach to measuring persistent currents in normal metal rings. By integrating micron-scale metal rings into sensitive micromechanical cantilevers and using the cantilevers as torque magnetometers, it should be possible to measure the rings' persistent currents with greater sensitivity than the SQUID-based and microwave resonator-based detectors used in the past. In addition, cantilever-based detectors may allow for measurements in a cleaner electromagnetic environment. We have fabricated ultra sensitive cantilevers with integrated rings and measured their mechanical properties. We present an estimate of the persistent current sensitivity of these cantilever-based detectors, focusing on the limits set by the cantilever's Brownian motion and the shot noise in the laser interferometer that monitors the cantilever.
△ Less
Submitted 27 October, 2007;
originally announced October 2007.
-
Noise thermometry and electron thermometry of a sample-on-cantilever system below 1 Kelvin
Authors:
A. C. Bleszynski Jayich,
W. E. Shanks,
J. G. E. Harris
Abstract:
We have used two types of thermometry to study thermal fluctuations in a microcantilever-based system below 1 K. We measured the temperature of a cantilever's macroscopic degree-of-freedom (via the Brownian motion of its lowest flexural mode) and its microscopic degrees-of-freedom (via the electron temperature of a metal sample mounted on the cantilever). We also measured both temperatures' resp…
▽ More
We have used two types of thermometry to study thermal fluctuations in a microcantilever-based system below 1 K. We measured the temperature of a cantilever's macroscopic degree-of-freedom (via the Brownian motion of its lowest flexural mode) and its microscopic degrees-of-freedom (via the electron temperature of a metal sample mounted on the cantilever). We also measured both temperatures' response to a localized heat source. We find it possible to maintain thermal equilibrium between these two temperatures and a refrigerator down to at least 300 mK. These results are promising for ongoing experiments to probe quantum effects using micromechanical devices.
△ Less
Submitted 21 August, 2007;
originally announced August 2007.