Skip to main content

Showing 1–11 of 11 results for author: Shanks, W E

.
  1. Minimum quantum run-time characterization and calibration via restless measurements with dynamic repetition rates

    Authors: Caroline Tornow, Naoki Kanazawa, William E. Shanks, Daniel J. Egger

    Abstract: The performance of a quantum processor depends on the characteristics of the device and the quality of the control pulses. Characterizing cloud-based quantum computers and calibrating the pulses that control them is necessary for high-fidelity operations. However, this time intensive task eats into the availability of the device. Here, we show restless measurements with a dynamic repetition rate t… ▽ More

    Submitted 15 August, 2022; v1 submitted 14 February, 2022; originally announced February 2022.

    Journal ref: Phys. Rev. Applied 17, 064061 (2022)

  2. arXiv:1510.08428  [pdf, other

    quant-ph cond-mat.mes-hall

    Imaging Photon Lattice States by Scanning Defect Microscopy

    Authors: D. L. Underwood, W. E. Shanks, Andy C. Y. Li, Lamia Ateshian, Jens Koch, A. A. Houck

    Abstract: Microwave photons inside lattices of coupled resonators and superconducting qubits can exhibit surprising matter-like behavior. Realizing such open-system quantum simulators presents an experimental challenge and requires new tools and measurement techniques. Here, we introduce Scanning Defect Microscopy as one such tool and illustrate its use in mapping the normal-mode structure of microwave phot… ▽ More

    Submitted 28 October, 2015; originally announced October 2015.

    Journal ref: Phys. Rev. X 6, 021044 (2016)

  3. arXiv:1303.0874  [pdf, other

    quant-ph cond-mat.mes-hall

    A scanning transmon qubit for strong coupling circuit quantum electrodynamics

    Authors: William E. Shanks, Devin L. Underwood, Andrew A. Houck

    Abstract: Like a quantum computer designed for a particular class of problems, a quantum simulator enables quantitative modeling of quantum systems that is computationally intractable with a classical computer. Quantum simulations of quantum many-body systems have been performed using ultracold atoms and trapped ions among other systems. Superconducting circuits have recently been investigated as an alterna… ▽ More

    Submitted 4 March, 2013; originally announced March 2013.

    Comments: 11 pages, 8 figures

    Journal ref: Nat. Comm. 4, 1991 (2013)

  4. Measurement of the full distribution of the persistent current in normal-metal rings

    Authors: M. A. Castellanos-Beltran, D. Q. Ngo, W. E. Shanks, A. B. Jayich, J. G. E. Harris

    Abstract: We have measured the persistent current in individual normal metal rings over a wide range of magnetic fields. From this data, we extract the first six cumulants of the single-ring persistent current distribution. Our results are consistent with the theoretical prediction that this distribution should be nearly Gaussian (i.e., that these cumulants should be nearly zero) for diffusive metallic ring… ▽ More

    Submitted 21 January, 2013; v1 submitted 17 April, 2012; originally announced April 2012.

    Comments: 14 pages, 4 figures and supplementary on-line information (31 pages)

  5. arXiv:1203.5363  [pdf, other

    quant-ph cond-mat.mes-hall

    Low-Disorder Microwave Cavity Lattices for Quantum Simulation with Photons

    Authors: Devin L. Underwood, Will E. Shanks, Jens Koch, Andrew A. Houck

    Abstract: We assess experimentally the suitability of coupled transmission line resonators for studies of quantum phase transitions of light. We have measured devices with low photon hopping rates t/2pi = 0.8MHz to quantify disorder in individual cavity frequencies. The observed disorder is consistent with small imperfections in fabrication. We studied the dependence of the disorder on transmission line geo… ▽ More

    Submitted 24 October, 2012; v1 submitted 23 March, 2012; originally announced March 2012.

    Journal ref: Phys. Rev. A 86, 023837 (2012)

  6. arXiv:1112.3395  [pdf, other

    cond-mat.mes-hall

    Persistent Currents in Normal Metal Rings (Yale PhD thesis)

    Authors: William E. Shanks

    Abstract: In this work, I present measurements of persistent currents in normal metal rings performed with cantilever torsional magnetometry. With this technique, the typical persistent current (the component that varies randomly from ring to ring) was measured with high sensitivity. I report measured magnitudes as low as 1 pA, over two orders of magnitude smaller than that observed in previous studies. The… ▽ More

    Submitted 14 December, 2011; originally announced December 2011.

    Comments: 436 pages, 141 figures; high resolution version available at http://www.yale.edu/harrislab; covers work presented in arXiv:0708.2878, arXiv:0710.5259, arXiv:0906.4780, and arXiv:1002.0700

  7. Mesoscopic persistent currents in a strong magnetic field

    Authors: Eran Ginossar, Leonid I. Glazman, Teemu Ojanen, Felix von Oppen, William E. Shanks, Ania C. Bleszynski-Jayich, J. G. E. Harris

    Abstract: Recent precision measurements of mesoscopic persistent currents in normal-metal rings rely on the interaction between the magnetic moment generated by the current and a large applied magnetic field. Motivated by this technique, we extend the theory of mesoscopic persistent currents to include the effect of the finite thickness of the ring and the resulting penetration of the large magnetic field… ▽ More

    Submitted 3 February, 2010; originally announced February 2010.

    Comments: 12 pages, 7 figures

  8. arXiv:0906.4780  [pdf

    cond-mat.mes-hall cond-mat.dis-nn

    Persistent currents in normal metal rings: comparing high-precision experiment with theory

    Authors: A. C. Bleszynski-Jayich, W. E. Shanks, B. Peaudecerf, E. Ginossar, F. von Oppen, L. Glazman, J. G. E. Harris

    Abstract: Quantum mechanics predicts that the equilibrium state of a resistive electrical circuit contains a dissipationless current. This persistent current has been the focus of considerable theoretical and experimental work, but its basic properties remain a topic of controversy. The main experimental challenges in studying persistent currents have been the small signals they produce and their exceptio… ▽ More

    Submitted 25 June, 2009; originally announced June 2009.

    Comments: 9 pages, 1 table, 3 figures, plus supplemental info(13 pages, 18 figures)

  9. High quality mechanical and optical properties of commercial silicon nitride membranes

    Authors: B. M. Zwickl, W. E. Shanks, A. M. Jayich, C. Yang, A. C. Bleszynski Jayich, J. D. Thompson, J. G. E. Harris

    Abstract: We have measured the optical and mechanical loss of commercial silicon nitride membranes. We find that 50 nm-thick, 1 mm^2 membranes have mechanical Q > 10^6 at 293 K, and Q > 10^7 at 300 mK, well above what has been observed in devices with comparable dimensions. The near-IR optical loss at 293 K is less than 2E-4. This combination of properties make these membranes attractive candidates for st… ▽ More

    Submitted 14 November, 2007; originally announced November 2007.

    Comments: 4 pages, 4 figures

  10. arXiv:0710.5259  [pdf

    cond-mat.mes-hall

    High sensitivity cantilevers for measuring persistent currents in normal metal rings

    Authors: Ania C. Bleszynski Jayich, Will E. Shanks, Rob Ilic, J. G. E. Harris

    Abstract: We propose a new approach to measuring persistent currents in normal metal rings. By integrating micron-scale metal rings into sensitive micromechanical cantilevers and using the cantilevers as torque magnetometers, it should be possible to measure the rings' persistent currents with greater sensitivity than the SQUID-based and microwave resonator-based detectors used in the past. In addition, c… ▽ More

    Submitted 27 October, 2007; originally announced October 2007.

  11. arXiv:0708.2878  [pdf

    cond-mat.other

    Noise thermometry and electron thermometry of a sample-on-cantilever system below 1 Kelvin

    Authors: A. C. Bleszynski Jayich, W. E. Shanks, J. G. E. Harris

    Abstract: We have used two types of thermometry to study thermal fluctuations in a microcantilever-based system below 1 K. We measured the temperature of a cantilever's macroscopic degree-of-freedom (via the Brownian motion of its lowest flexural mode) and its microscopic degrees-of-freedom (via the electron temperature of a metal sample mounted on the cantilever). We also measured both temperatures' resp… ▽ More

    Submitted 21 August, 2007; originally announced August 2007.