-
Assessing the Reliability Benefits of Energy Storage as a Transmission Asset
Authors:
David Sehloff,
Jonghwan Kwon,
Mahdi Mehrtash,
Todd Levin,
Benjamin F. Hobbs
Abstract:
Utilizing energy storage solutions to reduce the need for traditional transmission investments has been recognized by system planners and supported by federal policies in recent years. This work demonstrates the need for detailed reliability assessment for quantitative comparison of the reliability benefits of energy storage and traditional transmission investments. First, a mixed-integer linear p…
▽ More
Utilizing energy storage solutions to reduce the need for traditional transmission investments has been recognized by system planners and supported by federal policies in recent years. This work demonstrates the need for detailed reliability assessment for quantitative comparison of the reliability benefits of energy storage and traditional transmission investments. First, a mixed-integer linear programming expansion planning model considering candidate transmission lines and storage technologies is solved to find the least-cost investment decisions. Next, operations under the resulting system configuration are simulated in a probabilistic reliability assessment which accounts for weather-dependent forced outages. The outcome of this work, when applied to TPPs, is to further equalize the consideration of energy storage compared to traditional transmission assets by capturing the value of storage for system reliability.
△ Less
Submitted 31 July, 2024;
originally announced July 2024.
-
Enabling Undergrounding of Long-Distance Transmission Lines with Low Frequency AC Technology
Authors:
David K. Sehloff,
Line A. Roald
Abstract:
With increasing prevalence of severe natural hazards and the ignition of wildfires by power lines, many power system planners are considering converting overhead lines to underground cables to mitigate risks related to these events. Systems with a large proportion of underground cables can bring challenges due to the capacitance and losses of the cables, factors which may limit the potential for h…
▽ More
With increasing prevalence of severe natural hazards and the ignition of wildfires by power lines, many power system planners are considering converting overhead lines to underground cables to mitigate risks related to these events. Systems with a large proportion of underground cables can bring challenges due to the capacitance and losses of the cables, factors which may limit the potential for hardening in critical areas. Low frequency AC (LFAC) transmission solves these problems, as lowering the frequency decreases both the effects of capacitance and the losses. This paper presents a tractable frequency-dependent model for underground cables and incorporates it into the open source optimal power flow tool VariableFrequencyOPF.jl. The model and implementation are used to demonstrate the benefits of LFAC in a case study involving two multi-terminal cable upgrades with LFAC, including a comparison with HVDC. The results demonstrate the value of LFAC systems for both power flow control and reduction of losses.
△ Less
Submitted 7 July, 2022; v1 submitted 17 June, 2022;
originally announced June 2022.
-
Low Frequency AC Transmission Upgrades with Optimal Frequency Selection
Authors:
David Sehloff,
Line Roald
Abstract:
The advantages of operating selected transmission lines at frequencies other than the standard 50 or 60 Hz are numerous, encompassing increased power transfer capacity and better utilization of existing infrastructure. While high voltage DC (HVDC) is by far the most well-established example, there has been an emerging interest low frequency AC (LFAC) transmission in applications ranging from offsh…
▽ More
The advantages of operating selected transmission lines at frequencies other than the standard 50 or 60 Hz are numerous, encompassing increased power transfer capacity and better utilization of existing infrastructure. While high voltage DC (HVDC) is by far the most well-established example, there has been an emerging interest low frequency AC (LFAC) transmission in applications ranging from offshore wind to railway systems and mining. In this paper, we investigate the use of LFAC as a transmission upgrade and propose models and analysis methods to determine the optimal choice of frequency. The paper first presents an optimal power flow model with frequency as a variable, assuming modular multilevel converters for frequency conversion. Using this model, we analyze LFAC as an embedded upgrade in a transmission system using existing lines. We quantify the system-wide advantages from improved power flow control and frequency reduction and find that an LFAC upgrade achieves similar and sometimes better results compared with HVDC upgrades. Finally, we analyze the factors which determine the optimal frequency for these upgraded transmission lines, and we demonstrate the benefits of changing the frequency in response to different system topologies and operating conditions.
△ Less
Submitted 20 August, 2021; v1 submitted 11 March, 2021;
originally announced March 2021.
-
Steady State Modeling for Variable Frequency AC Power Flow
Authors:
David Sehloff,
Line Roald
Abstract:
Advantages of operating portions of a power system at frequencies different from the standard 50 or 60 Hz have been demonstrated in the low frequency AC (LFAC) and high voltage DC (HVDC) literature. Branches constrained by stability or thermal limits can benefit from increased capacity and flexibility. Since advances in power electronics enable the choice of an operating frequency, tools are neede…
▽ More
Advantages of operating portions of a power system at frequencies different from the standard 50 or 60 Hz have been demonstrated in the low frequency AC (LFAC) and high voltage DC (HVDC) literature. Branches constrained by stability or thermal limits can benefit from increased capacity and flexibility. Since advances in power electronics enable the choice of an operating frequency, tools are needed to make this choice. In order to quantify the advantages as functions of frequency, this paper provides models for steady state calculations with frequency as a variable and validates the modeling assumptions. It then introduces an analytical quantification of the power flow capacity of a transmission branch as a function of frequency, demonstrating different active constraints across the range of frequency. The modeling and power flow calculations are demonstrated for a practical transmission line using manufacturer data. The models presented here provide a foundation for system level studies with variable frequency using optimal power flow.
△ Less
Submitted 26 January, 2021;
originally announced January 2021.