Showing 1–2 of 2 results for author: Schertenleib, T
-
An Absorption Correction for Reliable Pair-Distribution Functions from Low Energy X-ray Sources
Authors:
Yucong Chen,
Till Schertenleib,
Andrew Yang,
Pascal Schouwink,
Wendy L. Queen,
Simon J. L. Billinge
Abstract:
This paper explores the development and testing of a simple absorption correction model for processing x-ray powder diffraction data from Debye-Scherrer geometry laboratory x-ray experiments. This may be used as a pre-processing step before using PDFgetX3 to obtain reliable pair distribution functions (PDFs). The correction was found to depend only on muD, the product of the x-ray attenuation coef…
▽ More
This paper explores the development and testing of a simple absorption correction model for processing x-ray powder diffraction data from Debye-Scherrer geometry laboratory x-ray experiments. This may be used as a pre-processing step before using PDFgetX3 to obtain reliable pair distribution functions (PDFs). The correction was found to depend only on muD, the product of the x-ray attenuation coefficient and capillary diameter. Various experimental and theoretical methods for estimating muD were explored, and the most appropriate muD values for correction were identified for different capillary diameters and x-ray beam sizes. We identify operational ranges of muD where reasonable signal to noise is possible after correction. A user-friendly software package, diffpy.labpdfproc, is presented that can help estimate muD and perform absorption corrections, with a rapid calculation for efficient processing.
△ Less
Submitted 16 April, 2025;
originally announced April 2025.
-
Testing Protocols for Obtaining Reliable PDFs from Laboratory x-ray Sources Using PDFgetX3
Authors:
Till Schertenleib,
Daniel Schmuckler,
Yucong Chen,
Geng Bang Jin,
Wendy L. Queen,
Simon J. L. Billinge
Abstract:
In this work, we explored data acquisition protocols and improved data reduction protocols using PDFgetX3 to obtain reliable data for atomic pair distribution function (PDF) analysis from a laboratory-based Mo x-ray source. A variable counting scheme is described that preferentially counts in the high-angle region of the diffraction pattern. The effects on the resulting PDF are studied by varying…
▽ More
In this work, we explored data acquisition protocols and improved data reduction protocols using PDFgetX3 to obtain reliable data for atomic pair distribution function (PDF) analysis from a laboratory-based Mo x-ray source. A variable counting scheme is described that preferentially counts in the high-angle region of the diffraction pattern. The effects on the resulting PDF are studied by varying the overall count time, the use of Soller slits, and limiting the out-of-plane divergence of the incident beam. The protocols are tested using an amorphous silica and a quartz sample. We also present a modification to the current PDFgetX3 data corrections to take care of sample absorption, which was previously neglected in the use of that program for high-energy synchrotron x-ray data. We show that, despite limitations in the Q-range and flux of laboratory instruments, reasonable data for PDF model fits may be obtained using the best protocols in a few hours of counting.
△ Less
Submitted 9 January, 2025; v1 submitted 26 June, 2024;
originally announced June 2024.