-
AI-based, automated chamber volumetry from gated, non-contrast CT
Authors:
Athira J Jacob,
Ola Abdelkarim,
Salma Zook,
Kristian Hay Kragholm,
Prantik Gupta,
Myra Cocker,
Juan Ramirez Giraldo,
Jim O Doherty,
Max Schoebinger,
Chris Schwemmer,
Mehmet A Gulsun,
Saikiran Rapaka,
Puneet Sharma,
Su-Min Chang
Abstract:
Background: Accurate chamber volumetry from gated, non-contrast cardiac CT (NCCT) scans can be useful for potential screening of heart failure.
Objectives: To validate a new, fully automated, AI-based method for cardiac volume and myocardial mass quantification from NCCT scans compared to contrasted CT Angiography (CCTA).
Methods: Of a retrospectively collected cohort of 1051 consecutive patie…
▽ More
Background: Accurate chamber volumetry from gated, non-contrast cardiac CT (NCCT) scans can be useful for potential screening of heart failure.
Objectives: To validate a new, fully automated, AI-based method for cardiac volume and myocardial mass quantification from NCCT scans compared to contrasted CT Angiography (CCTA).
Methods: Of a retrospectively collected cohort of 1051 consecutive patients, 420 patients had both NCCT and CCTA scans at mid-diastolic phase, excluding patients with cardiac devices. Ground truth values were obtained from the CCTA scans.
Results: The NCCT volume computation shows good agreement with ground truth values. Volume differences [95% CI ] and correlation coefficients were: -9.6 [-45; 26] mL, r = 0.98 for LV Total, -5.4 [-24; 13] mL, r = 0.95 for LA, -8.7 [-45; 28] mL, r = 0.94 for RV, -5.2 [-27; 17] mL, r = 0.92 for RA, -3.2 [-42; 36] mL, r = 0.91 for LV blood pool, and -6.7 [-39; 26] g, r = 0.94 for LV wall mass, respectively. Mean relative volume errors of less than 7% were obtained for all chambers.
Conclusions: Fully automated assessment of chamber volumes from NCCT scans is feasible and correlates well with volumes obtained from contrast study.
△ Less
Submitted 25 October, 2023;
originally announced November 2023.
-
Handling Label Uncertainty on the Example of Automatic Detection of Shepherd's Crook RCA in Coronary CT Angiography
Authors:
Felix Denzinger,
Michael Wels,
Oliver Taubmann,
Florian Kordon,
Fabian Wagner,
Stephanie Mehltretter,
Mehmet A. Gülsün,
Max Schöbinger,
Florian André,
Sebastian Buss,
Johannes Görich,
Michael Sühling,
Andreas Maier
Abstract:
Coronary artery disease (CAD) is often treated minimally invasively with a catheter being inserted into the diseased coronary vessel. If a patient exhibits a Shepherd's Crook (SC) Right Coronary Artery (RCA) - an anatomical norm variant of the coronary vasculature - the complexity of this procedure is increased. Automated reporting of this variant from coronary CT angiography screening would ease…
▽ More
Coronary artery disease (CAD) is often treated minimally invasively with a catheter being inserted into the diseased coronary vessel. If a patient exhibits a Shepherd's Crook (SC) Right Coronary Artery (RCA) - an anatomical norm variant of the coronary vasculature - the complexity of this procedure is increased. Automated reporting of this variant from coronary CT angiography screening would ease prior risk assessment. We propose a 1D convolutional neural network which leverages a sequence of residual dilated convolutions to automatically determine this norm variant from a prior extracted vessel centerline. As the SC RCA is not clearly defined with respect to concrete measurements, labeling also includes qualitative aspects. Therefore, 4.23% samples in our dataset of 519 RCA centerlines were labeled as unsure SC RCAs, with 5.97% being labeled as sure SC RCAs. We explore measures to handle this label uncertainty, namely global/model-wise random assignment, exclusion, and soft label assignment. Furthermore, we evaluate how this uncertainty can be leveraged for the determination of a rejection class. With our best configuration, we reach an area under the receiver operating characteristic curve (AUC) of 0.938 on confident labels. Moreover, we observe an increase of up to 0.020 AUC when rejecting 10% of the data and leveraging the labeling uncertainty information in the exclusion process.
△ Less
Submitted 22 May, 2023;
originally announced June 2023.
-
Multiscale Finite Element Formulations for 2D/1D Problems
Authors:
Karl Hollaus,
Markus Schöbinger
Abstract:
Multiscale finite element methods for 2D/1D problems have been studied in this work to demonstrate their excellent ability to solve real-world problems. These methods are much more efficient than conventional 3D finite element methods and just as accurate. The 2D/1D multiscale finite element methods are based on a magnetic vector potential or a current vector potential. Known currents for excitati…
▽ More
Multiscale finite element methods for 2D/1D problems have been studied in this work to demonstrate their excellent ability to solve real-world problems. These methods are much more efficient than conventional 3D finite element methods and just as accurate. The 2D/1D multiscale finite element methods are based on a magnetic vector potential or a current vector potential. Known currents for excitation can be replaced by the Biot-Savart-field. Boundary conditions allow to integrate planes of symmetry. All presented approaches consider eddy currents, an insulation layer and preserve the edge effect. A segment of a fictitious electrical machine has been studied to demonstrate all above options, the accuracy and the low computational costs of the 2D/1D multiscale finite element methods.
△ Less
Submitted 13 April, 2023;
originally announced April 2023.
-
An Equilibrated Error Estimator for the 2D/1D MSFEM T-Formulation of the Eddy Current Problem
Authors:
Markus Schöbinger,
Karl Hollaus
Abstract:
The 2D/1D multiscale finite element method (MSFEM) is an efficient way to simulate rotating machines in which each iron sheet is exposed to the same field. It allows the reduction of the three dimensional sheet to a two dimensional cross-section by resolving the dependence along the thickness of the sheet with a polynomial expansion. This work presents an equilibrated error estimator based on flux…
▽ More
The 2D/1D multiscale finite element method (MSFEM) is an efficient way to simulate rotating machines in which each iron sheet is exposed to the same field. It allows the reduction of the three dimensional sheet to a two dimensional cross-section by resolving the dependence along the thickness of the sheet with a polynomial expansion. This work presents an equilibrated error estimator based on flux equilibration and the theorem of Prager and Synge for the T-formulation of the eddy current problem in a 2D/1D MSFEM setting. The estimator is shown to give both a good approximation of the total error and to allow for adaptive mesh refinement by correctly estimating the local error distribution.
△ Less
Submitted 3 February, 2023;
originally announced February 2023.
-
CAD-RADS Scoring using Deep Learning and Task-Specific Centerline Labeling
Authors:
Felix Denzinger,
Michael Wels,
Oliver Taubmann,
Mehmet A. Gülsün,
Max Schöbinger,
Florian André,
Sebastian J. Buss,
Johannes Görich,
Michael Sühling,
Andreas Maier,
Katharina Breininger
Abstract:
With coronary artery disease (CAD) persisting to be one of the leading causes of death worldwide, interest in supporting physicians with algorithms to speed up and improve diagnosis is high. In clinical practice, the severeness of CAD is often assessed with a coronary CT angiography (CCTA) scan and manually graded with the CAD-Reporting and Data System (CAD-RADS) score. The clinical questions this…
▽ More
With coronary artery disease (CAD) persisting to be one of the leading causes of death worldwide, interest in supporting physicians with algorithms to speed up and improve diagnosis is high. In clinical practice, the severeness of CAD is often assessed with a coronary CT angiography (CCTA) scan and manually graded with the CAD-Reporting and Data System (CAD-RADS) score. The clinical questions this score assesses are whether patients have CAD or not (rule-out) and whether they have severe CAD or not (hold-out). In this work, we reach new state-of-the-art performance for automatic CAD-RADS scoring. We propose using severity-based label encoding, test time augmentation (TTA) and model ensembling for a task-specific deep learning architecture. Furthermore, we introduce a novel task- and model-specific, heuristic coronary segment labeling, which subdivides coronary trees into consistent parts across patients. It is fast, robust, and easy to implement. We were able to raise the previously reported area under the receiver operating characteristic curve (AUC) from 0.914 to 0.942 in the rule-out and from 0.921 to 0.950 in the hold-out task respectively.
△ Less
Submitted 8 February, 2022;
originally announced February 2022.
-
Coronary Plaque Analysis for CT Angiography Clinical Research
Authors:
Felix Denzinger,
Michael Wels,
Christian Hopfgartner,
Jing Lu,
Max Schöbinger,
Andreas Maier,
Michael Sühling
Abstract:
The analysis of plaque deposits in the coronary vasculature is an important topic in current clinical research. From a technical side mostly new algorithms for different sub tasks - e.g. centerline extraction or vessel/plaque segmentation - are proposed. However, to enable clinical research with the help of these algorithms, a software solution, which enables manual correction, comprehensive visua…
▽ More
The analysis of plaque deposits in the coronary vasculature is an important topic in current clinical research. From a technical side mostly new algorithms for different sub tasks - e.g. centerline extraction or vessel/plaque segmentation - are proposed. However, to enable clinical research with the help of these algorithms, a software solution, which enables manual correction, comprehensive visual feedback and tissue analysis capabilities, is needed. Therefore, we want to present such an integrated software solution. It is able to perform robust automatic centerline extraction and inner and outer vessel wall segmentation, while providing easy to use manual correction tools. Also, it allows for annotation of lesions along the centerlines, which can be further analyzed regarding their tissue composition. Furthermore, it enables research in upcoming technologies and research directions: it does support dual energy CT scans with dedicated plaque analysis and the quantification of the fatty tissue surrounding the vasculature, also in automated set-ups.
△ Less
Submitted 11 January, 2021;
originally announced January 2021.
-
Automatic CAD-RADS Scoring Using Deep Learning
Authors:
Felix Denzinger,
Michael Wels,
Katharina Breininger,
Mehmet A. Gülsün,
Max Schöbinger,
Florian André,
Sebastian Buß,
Johannes Görich,
Michael Sühling,
Andreas Maier
Abstract:
Coronary CT angiography (CCTA) has established its role as a non-invasive modality for the diagnosis of coronary artery disease (CAD). The CAD-Reporting and Data System (CAD-RADS) has been developed to standardize communication and aid in decision making based on CCTA findings. The CAD-RADS score is determined by manual assessment of all coronary vessels and the grading of lesions within the coron…
▽ More
Coronary CT angiography (CCTA) has established its role as a non-invasive modality for the diagnosis of coronary artery disease (CAD). The CAD-Reporting and Data System (CAD-RADS) has been developed to standardize communication and aid in decision making based on CCTA findings. The CAD-RADS score is determined by manual assessment of all coronary vessels and the grading of lesions within the coronary artery tree.
We propose a bottom-up approach for fully-automated prediction of this score using deep-learning operating on a segment-wise representation of the coronary arteries. The method relies solely on a prior fully-automated centerline extraction and segment labeling and predicts the segment-wise stenosis degree and the overall calcification grade as auxiliary tasks in a multi-task learning setup.
We evaluate our approach on a data collection consisting of 2,867 patients. On the task of identifying patients with a CAD-RADS score indicating the need for further invasive investigation our approach reaches an area under curve (AUC) of 0.923 and an AUC of 0.914 for determining whether the patient suffers from CAD. This level of performance enables our approach to be used in a fully-automated screening setup or to assist diagnostic CCTA reading, especially due to its neural architecture design -- which allows comprehensive predictions.
△ Less
Submitted 5 October, 2020;
originally announced October 2020.
-
Effective Medium Transformation: the Case of Stratified Magnetic Structures
Authors:
Markus Schöbinger,
Karl Hollaus,
Igor Tsukerman
Abstract:
Effective medium theory replaces a given fine-scale heterostructure with a homogeneous one in such a way that the physically measurable quantities, e.g. reaction fields and losses, remain approximately the same. This Letter shows that the very nature of the physical problem may change upon homogenization. A specific example is a stratified nonlinear magnetic and conducting medium, where a low freq…
▽ More
Effective medium theory replaces a given fine-scale heterostructure with a homogeneous one in such a way that the physically measurable quantities, e.g. reaction fields and losses, remain approximately the same. This Letter shows that the very nature of the physical problem may change upon homogenization. A specific example is a stratified nonlinear magnetic and conducting medium, where a low frequency excitation induces eddy currents. It is shown that the appropriate coarse-scale (homogeneous) model is, counter intuitively, magnetostatic, with an effective complex valued BH curve whose real and imaginary parts represent active and reactive losses in the sample. Similar situations may arise in other physical and engineering applications, notably, in diffusion problems with boundary layers.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.