Statistical characterization of residual noise in the low-rank approximation filter framework, general theory and application to hyperpolarized tracer spectroscopy
Authors:
R. Francischello,
M. F. Santarelli,
A. Flori,
L. Menichetti,
M. Geppi
Abstract:
The use of low-rank approximation filters in the field of NMR is increasing due to their flexibility and effectiveness. Despite their ability to reduce the Mean Square Error between the processed signal and the true signal is well known, the statistical distribution of the residual noise is still undescribed. In this article, we show that low-rank approximation filters are equivalent to linear fil…
▽ More
The use of low-rank approximation filters in the field of NMR is increasing due to their flexibility and effectiveness. Despite their ability to reduce the Mean Square Error between the processed signal and the true signal is well known, the statistical distribution of the residual noise is still undescribed. In this article, we show that low-rank approximation filters are equivalent to linear filters, and we calculate the mean and the covariance matrix of the processed data. We also show how to use this knowledge to build a maximum likelihood estimator, and we test the estimator's performance with a Montecarlo simulation of a 13C pyruvate metabolic tracer. While the article focuses on NMR spectroscopy experiment with hyperpolarized tracer, we also show that the results can be applied to tensorial data (e.g. using HOSVD) or 1D data (e.g. Cadzow filter).
△ Less
Submitted 4 October, 2023; v1 submitted 23 July, 2023;
originally announced July 2023.
-
Robust reconstruction of cardiac T1 maps using RNNs
Authors:
Nicola Martini,
Alessio Vatti,
Andrea Ripoli,
Sara Salaris,
Gianmarco Santini,
Maria Filomena Santarelli,
Dante Chiappino,
Daniele Della Latta
Abstract:
Cardiac magnetic resonance parametric T1 maps are typically reconstructed using non-linear fitting. However this method has limitations due to the high computational cost and robustness. In this study, a recurrent neural network (RNN) is proposed for the robust and fast reconstruction of cardiac T1 maps.
Cardiac magnetic resonance parametric T1 maps are typically reconstructed using non-linear fitting. However this method has limitations due to the high computational cost and robustness. In this study, a recurrent neural network (RNN) is proposed for the robust and fast reconstruction of cardiac T1 maps.
△ Less
Submitted 29 July, 2019;
originally announced July 2019.
-
Probabilistic Graphical Modeling approach to dynamic PET direct parametric map estimation and image reconstruction
Authors:
Michele Scipioni,
Stefano Pedemonte,
Maria Filomena Santarelli,
Luigi Landini
Abstract:
In the context of dynamic emission tomography, the conventional processing pipeline consists of independent image reconstruction of single time frames, followed by the application of a suitable kinetic model to time activity curves (TACs) at the voxel or region-of-interest level. The relatively new field of 4D PET direct reconstruction, by contrast, seeks to move beyond this scheme and incorporate…
▽ More
In the context of dynamic emission tomography, the conventional processing pipeline consists of independent image reconstruction of single time frames, followed by the application of a suitable kinetic model to time activity curves (TACs) at the voxel or region-of-interest level. The relatively new field of 4D PET direct reconstruction, by contrast, seeks to move beyond this scheme and incorporate information from multiple time frames within the reconstruction task. Existing 4D direct models are based on a deterministic description of voxels' TACs, captured by the chosen kinetic model, considering the photon counting process the only source of uncertainty. In this work, we introduce a new probabilistic modeling strategy based on the key assumption that activity time course would be subject to uncertainty even if the parameters of the underlying dynamic process were known. This leads to a hierarchical Bayesian model, which we formulate using the formalism of Probabilistic Graphical Modeling (PGM). The inference of the joint probability density function arising from PGM is addressed using a new gradient-based iterative algorithm, which presents several advantages compared to existing direct methods: it is flexible to an arbitrary choice of linear and nonlinear kinetic model; it enables the inclusion of arbitrary (sub)differentiable priors for parametric maps; it is simpler to implement and suitable to integration in computing frameworks for machine learning. Computer simulations and an application to real patient scan showed how the proposed approach allows us to weight the importance of the kinetic model, providing a bridge between indirect and deterministic direct methods.
△ Less
Submitted 24 August, 2018;
originally announced August 2018.
-
Kinetic Compressive Sensing
Authors:
Michele Scipioni,
Maria F. Santarelli,
Luigi Landini,
Ciprian Catana,
Douglas N. Greve,
Julie C. Price,
Stefano Pedemonte
Abstract:
Parametric images provide insight into the spatial distribution of physiological parameters, but they are often extremely noisy, due to low SNR of tomographic data. Direct estimation from projections allows accurate noise modeling, improving the results of post-reconstruction fitting. We propose a method, which we name kinetic compressive sensing (KCS), based on a hierarchical Bayesian model and o…
▽ More
Parametric images provide insight into the spatial distribution of physiological parameters, but they are often extremely noisy, due to low SNR of tomographic data. Direct estimation from projections allows accurate noise modeling, improving the results of post-reconstruction fitting. We propose a method, which we name kinetic compressive sensing (KCS), based on a hierarchical Bayesian model and on a novel reconstruction algorithm, that encodes sparsity of kinetic parameters. Parametric maps are reconstructed by maximizing the joint probability, with an Iterated Conditional Modes (ICM) approach, alternating the optimization of activity time series (OS-MAP-OSL), and kinetic parameters (MAP-LM). We evaluated the proposed algorithm on a simulated dynamic phantom: a bias/variance study confirmed how direct estimates can improve the quality of parametric maps over a post-reconstruction fitting, and showed how the novel sparsity prior can further reduce their variance, without affecting bias. Real FDG PET human brain data (Siemens mMR, 40min) images were also processed. Results enforced how the proposed KCS-regularized direct method can produce spatially coherent images and parametric maps, with lower spatial noise and better tissue contrast. A GPU-based open source implementation of the algorithm is provided.
△ Less
Submitted 27 March, 2018;
originally announced March 2018.