-
H-Mode Accelerating Structures with PMQ Beam Focusing
Authors:
Sergey S. Kurennoy,
Lawrence J. Rybarcyk,
James F. O'Hara,
Eric R. Olivas,
Thomas P. Wangler
Abstract:
We have developed high-efficiency normal-conducting RF accelerating structures by combining H-mode resonator cavities and a transverse beam focusing by permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of inter-digital H-mode (IH-PMQ) structures is 10-20 times higher than that of a conventional drift-tube linac, while t…
▽ More
We have developed high-efficiency normal-conducting RF accelerating structures by combining H-mode resonator cavities and a transverse beam focusing by permanent-magnet quadrupoles (PMQ), for beam velocities in the range of a few percent of the speed of light. The shunt impedance of inter-digital H-mode (IH-PMQ) structures is 10-20 times higher than that of a conventional drift-tube linac, while the transverse size is 4-5 times smaller. Results of the combined 3-D modeling - electromagnetic computations, multi-particle beam-dynamics simulations with high currents, and thermal-stress analysis - for an IH-PMQ accelerator tank are presented. The accelerating field profile in the tank is tuned to provide the best propagation of a 50-mA deuteron beam using coupled iterations of electromagnetic and beam-dynamics modeling. Measurements of a cold model of the IH-PMQ tank show a good agreement with the calculations. H-PMQ accelerating structures following a short RFQ can be used both in the front end of ion linacs or in stand-alone applications.
△ Less
Submitted 19 April, 2011;
originally announced April 2011.
-
Determining Phase-Space Properties of the LEDA RFQ Output Beam
Authors:
W. P. Lysenko,
J. D. Gilpatrick,
L. J. Rybarcyk,
J. D. Schneider,
H. V. Smith Jr,
L. M. Young,
M. E. Schulze
Abstract:
Quadrupole scans were used to characterize the LEDA RFQ beam. Experimental data were fit to computer simulation models for the rms beam size. The codes were found to be inadequate in accurately reproducing details of the wire scanner data. When this discrepancy is resolved, we plan to fit using all the data in wire scanner profiles, not just the rms values, using a 3-D nonlinear code.
Quadrupole scans were used to characterize the LEDA RFQ beam. Experimental data were fit to computer simulation models for the rms beam size. The codes were found to be inadequate in accurately reproducing details of the wire scanner data. When this discrepancy is resolved, we plan to fit using all the data in wire scanner profiles, not just the rms values, using a 3-D nonlinear code.
△ Less
Submitted 19 August, 2000;
originally announced August 2000.
-
High Power Operations of LEDA
Authors:
L. M. Young,
L. J. Rybarcyk,
J. D. Schneider,
M. E. Schulze,
H. V. Smith
Abstract:
The LEDA RFQ, a 350-MHz continuous wave (CW) radio-frequency quadrupole (RFQ), successfully accelerated a 100-mA CW proton beam from 75 keV to 6.7 MeV. We have accumulated 111 hr of beam on time with at least 90 mA of CW output beam current. The 8-m-long RFQ accelerates a dc, 75-keV, ~106-mA H+ beam from the LEDA injector with ~94% transmission. When operating the RFQ at the RF power level for w…
▽ More
The LEDA RFQ, a 350-MHz continuous wave (CW) radio-frequency quadrupole (RFQ), successfully accelerated a 100-mA CW proton beam from 75 keV to 6.7 MeV. We have accumulated 111 hr of beam on time with at least 90 mA of CW output beam current. The 8-m-long RFQ accelerates a dc, 75-keV, ~106-mA H+ beam from the LEDA injector with ~94% transmission. When operating the RFQ at the RF power level for which it was designed, the peak electrical field on the vane tips is 33 MV/m. However, to maintain the high transmission quoted above with the CW beam, it was necessary to operate the RFQ with field levels ~10% higher than design. The RFQ dissipates 1.5 MW of RF power when operating with this field. Three klystrons provide the 2.2 MW of RF power required by the RFQ to accelerate the 100-mA beam. The beam power is 670 kW. Some of the challenges that were met in accelerating a 100-mA CW proton beam to 6.7 MeV, will be discussed.
△ Less
Submitted 18 August, 2000;
originally announced August 2000.
-
LEDA Beam Operations Milestone and Observed Beam Transmission Characteristics
Authors:
L. J. Rybarcyk,
J. D. Schneider,
H. V. Smith,
L. M. Young,
M. E. Schulze
Abstract:
Recently, the Low-Energy Demonstration Accelerator (LEDA) portion of the Accelerator Production of Tritium (APT) project reached its 100-mA, 8-hr CW beam operation milestone. LEDA consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW radio-frequency quadrupole (RFQ) with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam…
▽ More
Recently, the Low-Energy Demonstration Accelerator (LEDA) portion of the Accelerator Production of Tritium (APT) project reached its 100-mA, 8-hr CW beam operation milestone. LEDA consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW radio-frequency quadrupole (RFQ) with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam dump. During the commissioning phase it was discovered that the RFQ field level must to be approximately 5-10% higher than design in order to accelerate the full 100-mA beam with low losses. Measurements of a low-duty-factor, 100-mA beam show the beam transmission is unexpectedly low for RFQ field levels between ~90 and 105% of design. This paper will describe some aspects of LEDA operations critical to achieving the above milestone. Measurement and simulation results for reduced RFQ beam transmission near design operating conditions are also presented.
△ Less
Submitted 16 August, 2000;
originally announced August 2000.
-
Beam Emittance Measurements for the Low-Energy Demonstration Accelerator Radio-Frequency Quadrupole
Authors:
M. E. Schulze,
J. D. Gilpatrick,
W. P. Lysenko,
L. J. Rybarcyk,
J. D. Schneider,
H. V. Smith, Jr.,
L. M. You
Abstract:
The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from the LEDA injector with >90% transmission. LEDA [1,2] consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW RFQ with associated high-power and low-level r…
▽ More
The Low-Energy Demonstration Accelerator (LEDA) radio-frequency quadrupole (RFQ) is a 100% duty factor (CW) linac that delivers >100 mA of H+ beam at 6.7 MeV. The 8-m-long, 350-MHz RFQ structure accelerates a dc, 75-keV, 110-mA H+ beam from the LEDA injector with >90% transmission. LEDA [1,2] consists of a 75-keV proton injector, 6.7-MeV, 350-MHz CW RFQ with associated high-power and low-level rf systems, a short high-energy beam transport (HEBT) and high-power (670-kW CW) beam stop. The beam emittance is inferred from wire scanner measurements of the beam profile at a single location in the HEBT. The beam profile is measured as a function of the magnetic field gradient in one of the HEBT quadrupoles. As the gradient is changed the spot size passes through a transverse waist. Measurements are presented for peak currents between 25 and 100 mA.
△ Less
Submitted 17 August, 2000; v1 submitted 15 August, 2000;
originally announced August 2000.