-
Real-Time Electro-Optic Dual Comb Detection of Ultrasound Waves
Authors:
Debanuj Chatterjee,
Louis Etien,
Simon Boivinet,
Hervé Rigneault,
Thomas Chaigne,
Arnaud Mussot
Abstract:
High-resolution ultrasound based imaging techniques like photoacoustic (PA) imaging that require fast detection of acoustic waves, are often coupled with an opto-mechanical sensor like a Fabry-Perot cavity (FPC) for enhanced sensitivity at high frequency. Due to the inherent inhomogeneity of the FPC thickness, the resonance of the cavity can exhibit a spatial distribution, requiring dynamic adjust…
▽ More
High-resolution ultrasound based imaging techniques like photoacoustic (PA) imaging that require fast detection of acoustic waves, are often coupled with an opto-mechanical sensor like a Fabry-Perot cavity (FPC) for enhanced sensitivity at high frequency. Due to the inherent inhomogeneity of the FPC thickness, the resonance of the cavity can exhibit a spatial distribution, requiring dynamic adjustment of the interrogation wavelength when raster-scanning the sensor with a probe beam. To avoid this, we propose in this work the use of an electro-optically modulated dual-comb light source for rapid acoustic wave sensing within a specified bandwidth. Utilizing a dual-comb vibrometry approach, we demonstrated a proof-of-principle of the technique, with real-time detection of 10 MHz acoustic waves simultaneously with three different teeth (separated by 10 GHz) of the dual-frequency comb, achieving a 20 ns temporal resolution. We also investigated the system's sensitivity limit in terms of the strength of the detected acoustic waves, opening new possibilities for ultrafast PA imaging modalities.
△ Less
Submitted 25 March, 2025;
originally announced March 2025.
-
A hollow-core fiber based stand-alone multimodal (2-photon, 3-photon, SHG, THG) nonlinear flexible imaging endoscope
Authors:
D. Septier,
G. Brévalle-Wasilewski,
E. Lefebvre,
N. Gajendra Kumar,
Y. J. Wang,
A. Kaszas,
H. Rigneault,
A. Kudlinski
Abstract:
Multimodal nonlinear endoscopes have been a topic of intense research over the past two decades, enabling sub-cellular and label-free imaging in areas not reachable with table-top microscopes. They are sophisticated systems that can be implemented on an optical table in a lab environment, but they cannot be easily moved within or out of the lab. We present here a multimodal and flexible nonlinear…
▽ More
Multimodal nonlinear endoscopes have been a topic of intense research over the past two decades, enabling sub-cellular and label-free imaging in areas not reachable with table-top microscopes. They are sophisticated systems that can be implemented on an optical table in a lab environment, but they cannot be easily moved within or out of the lab. We present here a multimodal and flexible nonlinear endoscope system able to perform two photon excited fluorescence and second harmonic generation imaging with a stand-alone and moveable kart integrating a compact ultrashort laser source. In addition, the system can perform three photon excited fluorescence and third harmonic generation thanks to a delivery optical fiber used to deliver ultrashort pulses from massive and not movable laser systems into the stand-alone kart. The endoscopic fiber probes and delivery optical fibers are based on functionalized negative curvature hollow core fibers. The endoscope distal head has a diameter <2.2mm and can perform nonlinear imaging at max 10 frames/s over a field of view up to 600 $μ$m with a ~1 $μ$m spatial resolution.
△ Less
Submitted 14 March, 2024;
originally announced March 2024.
-
Low frequency coherent Raman imaging robust to optical scattering
Authors:
David R. Smith,
Jesse W. Wilson,
Siddarth Shivkumar,
Herve Rigneault,
Randy A. Bartels
Abstract:
We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in non-scattering specimens, such a…
▽ More
We demonstrate low-frequency interferometric impulsive stimulated Raman scattering (ISRS) imaging with high robustness to distortions by optical scattering. ISRS is a pump-probe coherent Raman spectroscopy that can capture Raman vibrational spectra. Recording of ISRS spectra requires isolation of a probe pulse from the pump pulse. While this separation is simple in non-scattering specimens, such as liquids, scattering leads to significant pump pulse contamination and prevent the extraction of a Raman spectrum. We introduce a robust method for ISRS microscopy that works in complex scattering samples. High signal-to-noise ISRS spectra are obtained even when the pump and probe pulses pass through many scattering layers.
△ Less
Submitted 10 February, 2024;
originally announced February 2024.
-
Hyperspectral acquisition with ScanImage at the single pixel level: Application to time domain coherent Raman imaging
Authors:
Samuel Metais,
Sisira Suresh,
Paulo Diniz,
Siddarth Shivkumar,
Randy Bartels,
Nicolas Forget,
Hervé Rigneault
Abstract:
We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time dependent signal varies at each pixel level. In the proposed acquisition scheme the scan along the X axis is slowed down while the data acquisition is maintained at high pace to enable the rapid acquisition of the…
▽ More
We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time dependent signal varies at each pixel level. In the proposed acquisition scheme the scan along the X axis is slowed down while the data acquisition is maintained at high pace to enable the rapid acquisition of the time dependent signal at each pixel level. The ScanImage generated raw 2D images have a very asymmetric aspect ratio between X and Y, the X axis encoding both for space and time acquisition. The results are X axis macro-pixel where the associated time depend signal is sampled therefore providing an hyperspectral information. We exemplified the proposed hyperspectral scheme in the context of time domain coherent Raman imaging where a pump pulse impulsively excites molecular vibrations that are subsequently probed by a time delayed probe pulse. In this case the time dependent signal is a fast acousto-optics delay line that can scan a delay of 4.5ps in 25$μ$s, at each pixel level. We this acquisition scheme we demonstrate ultra-fast hyperspectral vibrational imaging in the low frequency range [10$cm^{-1}$, 150 $cm^{-1}$] over a 500 $μm$ field of view in 14ms (7 frames/s). The proposed acquisition scheme can be readily extended to other applications requiring to acquired a fast evolving signal at each pixel level.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
Interferometric single-pixel imaging with a multicore fiber
Authors:
Olivier Leblanc,
Matthias Hofer,
Siddharth Sivankutty,
Hervé Rigneault,
Laurent Jacques
Abstract:
Lensless illumination single-pixel imaging with a multicore fiber (MCF) is a computational imaging technique that enables potential endoscopic observations of biological samples at cellular scale. In this work, we show that this technique is tantamount to collecting multiple symmetric rank-one projections (SROP) of a Hermitian \emph{interferometric} matrix -- a matrix encoding the spectral content…
▽ More
Lensless illumination single-pixel imaging with a multicore fiber (MCF) is a computational imaging technique that enables potential endoscopic observations of biological samples at cellular scale. In this work, we show that this technique is tantamount to collecting multiple symmetric rank-one projections (SROP) of a Hermitian \emph{interferometric} matrix -- a matrix encoding the spectral content of the sample image. In this model, each SROP is induced by the complex \emph{sketching} vector shaping the incident light wavefront with a spatial light modulator (SLM), while the projected interferometric matrix collects up to $O(Q^2)$ image frequencies for a $Q$-core MCF. While this scheme subsumes previous sensing modalities, such as raster scanning (RS) imaging with beamformed illumination, we demonstrate that collecting the measurements of $M$ random SLM configurations -- and thus acquiring $M$ SROPs -- allows us to estimate an image of interest if $M$ and $Q$ scale linearly (up to log factors) with the image sparsity level, hence requiring much fewer observations than RS imaging or a complete Nyquist sampling of the $Q \times Q$ interferometric matrix. This demonstration is achieved both theoretically, with a specific restricted isometry analysis of the sensing scheme, and with extensive Monte Carlo experiments. Experimental results made on an actual MCF system finally demonstrate the effectiveness of this imaging procedure on a benchmark image.
△ Less
Submitted 17 July, 2023;
originally announced July 2023.
-
Interferometric lensless imaging: rank-one projections of image frequencies with speckle illuminations
Authors:
Olivier Leblanc,
Mathias Hofer,
Siddharth Sivankutty,
Hervé Rigneault,
Laurent Jacques
Abstract:
Lensless illumination single-pixel imaging with a multicore fiber (MCF) is a computational imaging technique that enables potential endoscopic observations of biological samples at cellular scale. In this work, we show that this technique is tantamount to collecting multiple symmetric rank-one projections (SROP) of an interferometric matrix--a matrix encoding the spectral content of the sample ima…
▽ More
Lensless illumination single-pixel imaging with a multicore fiber (MCF) is a computational imaging technique that enables potential endoscopic observations of biological samples at cellular scale. In this work, we show that this technique is tantamount to collecting multiple symmetric rank-one projections (SROP) of an interferometric matrix--a matrix encoding the spectral content of the sample image. In this model, each SROP is induced by the complex sketching vector shaping the incident light wavefront with a spatial light modulator (SLM), while the projected interferometric matrix collects up to $O(Q^2)$ image frequencies for a $Q$-core MCF. While this scheme subsumes previous sensing modalities, such as raster scanning (RS) imaging with beamformed illumination, we demonstrate that collecting the measurements of $M$ random SLM configurations--and thus acquiring $M$ SROPs--allows us to estimate an image of interest if $M$ and $Q$ scale log-linearly with the image sparsity level This demonstration is achieved both theoretically, with a specific restricted isometry analysis of the sensing scheme, and with extensive Monte Carlo experiments. On a practical side, we perform a single calibration of the sensing system robust to certain deviations to the theoretical model and independent of the sketching vectors used during the imaging phase. Experimental results made on an actual MCF system demonstrate the effectiveness of this imaging procedure on a benchmark image.
△ Less
Submitted 6 March, 2024; v1 submitted 22 June, 2023;
originally announced June 2023.
-
Ultralow-Noise Optical Parametric Amplifier for Stimulated Raman Scattering Imaging
Authors:
Ines Martin,
Yoann Pertot,
Olivier Albert,
Thomas Pinoteau,
Sébastien Coudreau,
Simon Pomarède,
José Villanueva,
Grégory Gitzinger,
Penda Leye,
Ivan Jelicic,
Cyril Vaneph,
Daniel Kaplan,
Simone Bux,
Nicolas Forget,
Thibaut Sylvestre,
Samuel Métais,
Hervé Rigneault
Abstract:
We present a 40-MHz ultrafast optical parametric amplifier (OPA), tunable from 0.8 to 1 $μ$m, with a relative intensity noise (RIN) matching the shot-noise floor (-160 dB/Hz) above 2 MHz. The OPA is pumped by a 20-W Kerr-lens mode-locked Ytterbium laser and seeded by a a supercontinuum generated in an all-normal-dispersion (ANDi) fiber. With an average output power >1.5 W, this compact and simple…
▽ More
We present a 40-MHz ultrafast optical parametric amplifier (OPA), tunable from 0.8 to 1 $μ$m, with a relative intensity noise (RIN) matching the shot-noise floor (-160 dB/Hz) above 2 MHz. The OPA is pumped by a 20-W Kerr-lens mode-locked Ytterbium laser and seeded by a a supercontinuum generated in an all-normal-dispersion (ANDi) fiber. With an average output power >1.5 W, this compact and simple scheme is an attractive alternative to synchronously-pumped optical parametric oscillators, especially within the context of stimulated Raman scattering (SRS) imaging. To illustrate the latter, we perform chemical imaging of vinegar droplets in oil by SRS microscopy.
△ Less
Submitted 5 February, 2024; v1 submitted 12 May, 2023;
originally announced May 2023.
-
Coherent Stokes Raman scattering microscopy (CSRS)
Authors:
Sandro Heuke,
Hervé Rigneault
Abstract:
We report the first implementation of laser scanning Coherent Stokes Raman scattering (CSRS - pronounced "sCiSsoRS") microscopy. To overcome the major challenge in CSRS imaging, we show how to suppress the fluorescence background by narrow bandpass filter and a lock-in based demodulation. Near background free CSRS imaging of polymer beads, human skin, onion cells, avocado flesh and the wing disc o…
▽ More
We report the first implementation of laser scanning Coherent Stokes Raman scattering (CSRS - pronounced "sCiSsoRS") microscopy. To overcome the major challenge in CSRS imaging, we show how to suppress the fluorescence background by narrow bandpass filter and a lock-in based demodulation. Near background free CSRS imaging of polymer beads, human skin, onion cells, avocado flesh and the wing disc of a drosphila larva are presented. Finally, we explain and demonstrate numerically that CSRS solves a major obstacle of other coherent Raman techniques by sending a significant part (up to 100%) of the CSRS photons into the backward direction under tight focusing conditions. We believe that this discovery will pave the way for numerous technological advances, e.g. in epi-detected coherent Raman multi-focus imaging, real-time laser scanning based spectroscopy or efficient endoscopy.
△ Less
Submitted 9 January, 2023;
originally announced January 2023.
-
Fast interrogation wavelength tuning for all-optical photoacoustic imaging
Authors:
Jérémy Saucourt,
Antonin Moreau,
Julien Lumeau,
Hervé Rigneault,
Thomas Chaigne
Abstract:
Optical detection of ultrasound for photoacoustic imaging provides large bandwidth and high sensitivity at high acoustic frequencies. Higher spatial resolutions can therefore be achieved using Fabry-Pérot cavity sensors, as compared to conventional piezoelectric detection. However, fabrication constraints during deposition of the sensing polymer layer require a precise control of the interrogation…
▽ More
Optical detection of ultrasound for photoacoustic imaging provides large bandwidth and high sensitivity at high acoustic frequencies. Higher spatial resolutions can therefore be achieved using Fabry-Pérot cavity sensors, as compared to conventional piezoelectric detection. However, fabrication constraints during deposition of the sensing polymer layer require a precise control of the interrogation beam wavelength to provide optimal sensitivity. This is commonly achieved by employing slowly tunable narrowband lasers as interrogation sources, hence limiting the acquisition speed. We propose instead to use a broadband source and a fast tunable acousto-optic filter to adjust the interrogation wavelength at each pixel within a few microseconds. We demonstrate the validity of this approach by performing photoacoustic imaging with a highly inhomogeneous Fabry-Pérot sensor.
△ Less
Submitted 16 October, 2022;
originally announced October 2022.
-
Photon-noise: Is a single-pixel camera better than point scanning? A signal-to-noise ratio analysis for Hadamard and Cosine positive modulation
Authors:
Camille Scotté,
Frédéric Galland,
Hervé Rigneault
Abstract:
In a single-pixel camera, an unknown object is sequentially illuminated by intensity patterns. The total reflected or transmitted intensity is summed in a single-pixel detector from which the object is computationally reconstructed. In the situation where the measurements are limited by photon-noise, it is questionable whether a single-pixel camera performs better or worse than simply scanning the…
▽ More
In a single-pixel camera, an unknown object is sequentially illuminated by intensity patterns. The total reflected or transmitted intensity is summed in a single-pixel detector from which the object is computationally reconstructed. In the situation where the measurements are limited by photon-noise, it is questionable whether a single-pixel camera performs better or worse than simply scanning the object with a focused intensity spot - a modality known as \textit{point raster scanning} and employed in many laser scanning systems. Here, we solve this general question and report that positive intensity modulation based on Hadamard or Cosine patterns does not necessarily improve the single-to-noise ratio (SNR) of single-pixel cameras as compared to point raster scanning, as compared to a raster-scanning. Instead, we show that the SNR is only improved on object pixels at least k times brighter than the object mean signal, where k is a constant that depends on the modulation scheme. This fundamental property is demonstrated theoretically and numerically. It is also experimentally confirmed in the spatial domain - for widefield fluorescence imaging - and in the spectral domain - for spontaneous Raman spectral measurements. Finally, we provide user-oriented guidelines that help decide when and how multiplexing under photon-noise should be used instead of point raster scanning.
△ Less
Submitted 4 October, 2022;
originally announced October 2022.
-
Signal-to-noise ratio analysis of single-pixel detection multiplexing under photon-noise. Cases of Hadamard and Cosine positive modulation
Authors:
Camille Scotté,
Frédéric Galland,
Hervé Rigneault
Abstract:
In typical single-pixel detection multiplexing, an unknown object is sequentially illuminated with intensity patterns: the total signal is summed into a single-pixel detector and is then demultiplexed to retrieve the object. Because of measurement noise, the retrieved object differs from the ground truth by some error quantified by the signal-to-noise ratio (SNR). In situations where the noise onl…
▽ More
In typical single-pixel detection multiplexing, an unknown object is sequentially illuminated with intensity patterns: the total signal is summed into a single-pixel detector and is then demultiplexed to retrieve the object. Because of measurement noise, the retrieved object differs from the ground truth by some error quantified by the signal-to-noise ratio (SNR). In situations where the noise only arises from the photon counting process, it has not been made clear if single-pixel detection multiplexing leads to a better SNR than simply scanning the object with a focused intensity spot - a modality known as raster scanning. This study theoretically assesses the SNR associated with certain types of single-pixel detection multiplexing, and compares it with raster scanning. In particular, we show that, under photon noise, when the positive intensity modulation is based on Hadamard or Cosine patterns, single-pixel detection multiplexing does not systematically improve the SNR as compared to raster scanning. Instead, it only improves the SNR on object pixels at least $k$ times brighter than the object mean signal $\bar{x}$, where $k$ is a constant that depends on the modulation scheme.
△ Less
Submitted 13 April, 2022;
originally announced April 2022.
-
Tapered multi-core fiber for lensless endoscopes
Authors:
Fatima El Moussawi,
Matthias Hofer,
Damien Labat,
Andy Cassez,
Géraud Bouwmans,
Siddharth Sivankutty,
Rosa Cossart,
Olivier Vanvincq,
Hervé Rigneault,
Esben Ravn Andresen
Abstract:
We present a novel fiber-optic component, a "tapered multi-core fiber (MCF)", designed for integration into ultra-miniaturized endoscopes for minimally invasive two-photon point-scanning imaging and to address the power delivery issue that has faced MCF based lensless endoscopes. With it we achieve experimentally a factor 6.0 increase in two-photon signal yield while keeping the ability to point-s…
▽ More
We present a novel fiber-optic component, a "tapered multi-core fiber (MCF)", designed for integration into ultra-miniaturized endoscopes for minimally invasive two-photon point-scanning imaging and to address the power delivery issue that has faced MCF based lensless endoscopes. With it we achieve experimentally a factor 6.0 increase in two-photon signal yield while keeping the ability to point-scan by the memory effect, and a factor 8.9 sacrificing the memory effect. To reach this optimal design we first develop and validate a fast numerical model capable of predicting the essential properties of an arbitrarily tapered MCF from its structural parameters. We then use this model to identify the tapered MCF design parameters that result in a chosen set of target properties (point-spread function, delivered power, presence or absence of memory effect). We fabricate the identified target designs by stack-and-draw and post-processing on a CO$_{2}$ laser-based glass processing and splicing system. Finally we demonstrate the performance gain of the fabricated tapered MCFs in two-photon imaging when used in a lensless endoscope system. Our results show that tailoring of the taper profile brings new degrees of freedom that can be efficiently exploited for lensless endoscopes.
△ Less
Submitted 7 April, 2022;
originally announced April 2022.
-
Miniature 120-beam coherent combiner with 3D printed optics for multicore fiber based endoscopy
Authors:
Siddharth Sivankutty,
Andrea Bertoncini,
Victor Tsvirkun,
Naveen Gajendra Kumar,
Gaelle Brévalle,
Géraud Bouwmans,
Esben Ravn Andresen,
Carlo Liberale,
Hervé Rigneault
Abstract:
We report high efficiency, miniaturized, ultra-fast coherent beam combining with 3D printed micro-optics directly on the tip of a multicore fiber bundle. The highly compact device foot-print (180 micron diameter) facilitates its incorporation into a minimally invasive ultra-thin nonlinear endoscope to perform two-photon imaging
We report high efficiency, miniaturized, ultra-fast coherent beam combining with 3D printed micro-optics directly on the tip of a multicore fiber bundle. The highly compact device foot-print (180 micron diameter) facilitates its incorporation into a minimally invasive ultra-thin nonlinear endoscope to perform two-photon imaging
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Roadmap on Wavefront Shaping and deep imaging in complex media
Authors:
Sylvain Gigan,
Ori Katz,
Hilton B. de Aguiar,
Esben Ravn Andresen,
Alexandre Aubry,
Jacopo Bertolotti,
Emmanuel Bossy,
Dorian Bouchet,
Joshua Brake,
Sophie Brasselet,
Yaron Bromberg,
Hui Cao,
Thomas Chaigne,
Zhongtao Cheng,
Wonshik Choi,
Tomáš Čižmár,
Meng Cui,
Vincent R Curtis,
Hugo Defienne,
Matthias Hofer,
Ryoichi Horisaki,
Roarke Horstmeyer,
Na Ji,
Aaron K. LaViolette,
Jerome Mertz
, et al. (20 additional authors not shown)
Abstract:
The last decade has seen the development of a wide set of tools, such as wavefront shaping, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tiss…
▽ More
The last decade has seen the development of a wide set of tools, such as wavefront shaping, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tissues. This roadmap highlights several key aspects of this fast developing field, and some of the challenges and opportunities ahead.
△ Less
Submitted 29 November, 2021;
originally announced November 2021.
-
Compressive lensless endoscopy with partial speckle scanning
Authors:
Stéphanie Guérit,
Siddharth Sivankutty,
John Aldo Lee,
Hervé Rigneault,
Laurent Jacques
Abstract:
The lensless endoscope (LE) is a promising device to acquire in vivo images at a cellular scale. The tiny size of the probe enables a deep exploration of the tissues. Lensless endoscopy with a multicore fiber (MCF) commonly uses a spatial light modulator (SLM) to coherently combine, at the output of the MCF, few hundreds of beamlets into a focus spot. This spot is subsequently scanned across the s…
▽ More
The lensless endoscope (LE) is a promising device to acquire in vivo images at a cellular scale. The tiny size of the probe enables a deep exploration of the tissues. Lensless endoscopy with a multicore fiber (MCF) commonly uses a spatial light modulator (SLM) to coherently combine, at the output of the MCF, few hundreds of beamlets into a focus spot. This spot is subsequently scanned across the sample to generate a fluorescent image. We propose here a novel scanning scheme, partial speckle scanning (PSS), inspired by compressive sensing theory, that avoids the use of an SLM to perform fluorescent imaging in LE with reduced acquisition time. Such a strategy avoids photo-bleaching while keeping high reconstruction quality. We develop our approach on two key properties of the LE: (i) the ability to easily generate speckles, and (ii) the memory effect in MCF that allows to use fast scan mirrors to shift light patterns. First, we show that speckles are sub-exponential random fields. Despite their granular structure, an appropriate choice of the reconstruction parameters makes them good candidates to build efficient sensing matrices. Then, we numerically validate our approach and apply it on experimental data. The proposed sensing technique outperforms conventional raster scanning: higher reconstruction quality is achieved with far fewer observations. For a fixed reconstruction quality, our speckle scanning approach is faster than compressive sensing schemes which require to change the speckle pattern for each observation.
△ Less
Submitted 22 April, 2021;
originally announced April 2021.
-
Line-scan Compressive Raman imaging with spatio-spectral encoding
Authors:
Camille Scotté,
Siddharth Sivankutty,
Randy A. Bartels,
Hervé Rigneault
Abstract:
We report a line-scanning imaging modality of Compressive Raman technology with a single-pixel detector. The spatial information along the illumination line is encoded onto one axis of a digital micromirror device, while spectral coding masks are applied along the orthogonal direction. We demonstrate imaging and classification of three different chemical species.
We report a line-scanning imaging modality of Compressive Raman technology with a single-pixel detector. The spatial information along the illumination line is encoded onto one axis of a digital micromirror device, while spectral coding masks are applied along the orthogonal direction. We demonstrate imaging and classification of three different chemical species.
△ Less
Submitted 12 June, 2020;
originally announced June 2020.
-
Linear and nonlinear fiber propagation of partially coherent fields exhibiting temporal correlations
Authors:
Frédéric Audo,
Herve Rigneault,
Christophe Finot
Abstract:
Using ultrafast photonic first-order differentiator applied on a partially coherent field, we report the generation of two correlated temporal waveforms and study their correlation properties upon linear and nonlinear propagation along the two orthogonal polarization axis of a dispersive optical fiber. Temporal correlations are maintained in linear propagation whereas Kerr nonlinearity generates a…
▽ More
Using ultrafast photonic first-order differentiator applied on a partially coherent field, we report the generation of two correlated temporal waveforms and study their correlation properties upon linear and nonlinear propagation along the two orthogonal polarization axis of a dispersive optical fiber. Temporal correlations are maintained in linear propagation whereas Kerr nonlinearity generates anti-correlated temporal intensity patterns for both partially and uncorrelated fields. Experiments are in close agreement with the theoretical analysis.
△ Less
Submitted 17 December, 2019;
originally announced December 2019.
-
Noise in stimulated Raman scattering measurement: From basics to practice
Authors:
Xavier Audier,
Sandro Heuke,
Peter Volz,
Ingo Rimke,
Hervé Rigneault
Abstract:
We revisit laser intensity noise in the context of stimulated Raman scattering (SRS), which has recently proved to be a key technique to provide label free images of chemical bonds in biological and medical samples. Contrary to most microscopy techniques, which detect a weak photon flux resulting from light matter interactions, SRS is a pump-probe scheme that works in the high flux regime and happ…
▽ More
We revisit laser intensity noise in the context of stimulated Raman scattering (SRS), which has recently proved to be a key technique to provide label free images of chemical bonds in biological and medical samples. Contrary to most microscopy techniques, which detect a weak photon flux resulting from light matter interactions, SRS is a pump-probe scheme that works in the high flux regime and happens as a weak modulation ($10^{-4}-10^{-6}$) in a strong laser field. As a result, laser noise is a key issue in SRS detection. This practical tutorial provides the experimentalists with the tools required to assess the amount of noise and the ultimate SRS detection limit in a conventional lock-in-based SRS system. We first define the quantities that are relevant when discussing intensity noise, and illustrate them through a conventional model of light detection by a photodiode. Stimulated Raman Scattering is then introduced in its lock-in-based implementation, and the model presented is adapted in this particular case. The power spectral density (PSD), relative intensity noise (RIN), signal to noise ratio (SNR), and sensitivity of the system are derived and discussed. Two complementary methods are presented that allow measurement of the RIN and assessment of the performance of a SRS system. Such measurements are illustrated on two commercial laser systems. Finally, the consequences of noise in SRS are discussed, and future developments are suggested. The presentation is made simple enough for under-graduated, graduated students, and newcomers in the field of stimulated Raman, and more generally in pump-probe based schemes.
△ Less
Submitted 28 October, 2019;
originally announced October 2019.
-
Shot noise limited high speed stimulated Raman microscopy
Authors:
Xavier Audier,
Nicolas Forget,
Hervé Rigneault
Abstract:
We report a shot noise limited high speed stimulated Raman microscopy platform allowing to acquire molecular vibrational spectra over \SI{200}{\per \cm} in \SI{12}{\micro \second} at a scan rate of 40kHz. Using spectral focusing together with optimized acousto-optics programmable dispersive filters the designed low noise imaging platform performs chemical imaging of dynamical processes such as Man…
▽ More
We report a shot noise limited high speed stimulated Raman microscopy platform allowing to acquire molecular vibrational spectra over \SI{200}{\per \cm} in \SI{12}{\micro \second} at a scan rate of 40kHz. Using spectral focusing together with optimized acousto-optics programmable dispersive filters the designed low noise imaging platform performs chemical imaging of dynamical processes such as Mannitol crystal hydratation and reaches a signal to noise ratio sufficient to perform label free histological imaging on frozen human colon tissue slides.
△ Less
Submitted 28 May, 2019;
originally announced May 2019.
-
Flexible lensless endoscope with a conformationally invariant multi-core fiber
Authors:
Viktor Tsvirkun,
Siddharth Sivankutty,
Karen Baudelle,
Rémi Habert,
Géraud Bouwmans,
Olivier Vanvincq,
Esben Ravn Andresen,
Hervé Rigneault
Abstract:
The lensless endoscope represents the ultimate limit in miniaturization of imaging tools: an image can be transmitted through a (multi-mode or multi-core) fiber by numerical or physical inversion of the fiber's pre-measured transmission matrix. However, the transmission matrix changes completely with only minute conformational changes of the fiber, which has so far limited lensless endoscopes to f…
▽ More
The lensless endoscope represents the ultimate limit in miniaturization of imaging tools: an image can be transmitted through a (multi-mode or multi-core) fiber by numerical or physical inversion of the fiber's pre-measured transmission matrix. However, the transmission matrix changes completely with only minute conformational changes of the fiber, which has so far limited lensless endoscopes to fibers that must be kept static. In this letter we report for the first time a lensless endoscope which is exempt from the requirement of static fiber by designing and employing a custom-designed conformationally invariant fiber. We give experimental and theoretical validations and determine the parameter space over which the invariance is maintained.
△ Less
Submitted 23 May, 2019;
originally announced May 2019.
-
Fast stimulated Raman imaging for intraoperative gastro-intestinal cancer detection
Authors:
Barbara Sarri,
Rafaël Canonge,
Xavier Audier,
Emma Simon,
Julien Wojak,
Fabrice Caillol,
Cécile Cador,
Didier Marguet,
Flora Poizat,
Marc Giovannini,
Hervé Rigneault
Abstract:
Conventional haematoxylin, eosin and saffron (HES) histopathology, currently the gold-standard for pathological diagnosis of cancer, requires extensive sample preparations that are achieved within time scales that are not compatible with intra-operative situations where quick decisions must be taken. Providing to pathologists a close to real-time technology revealing tissue structures at the cellu…
▽ More
Conventional haematoxylin, eosin and saffron (HES) histopathology, currently the gold-standard for pathological diagnosis of cancer, requires extensive sample preparations that are achieved within time scales that are not compatible with intra-operative situations where quick decisions must be taken. Providing to pathologists a close to real-time technology revealing tissue structures at the cellular level with HES histologic quality would provide an invaluable tool for surgery guidance with evident clinical benefit. Here, we specifically develop a stimulated Raman imaging based framework that demonstrates gastro-intestinal (GI) cancer detection of unprocessed human surgical specimens. The generated stimulated Raman histology (SRH) images combine chemical and collagen information to mimic conventional HES histopathology staining. We report excellent agreements between SRH and HES images acquire on the same patients for healthy, pre-cancerous and cancerous colon and pancreas tissue sections. We also develop a novel fast SRH imaging modality that captures at the pixel level all the information necessary to provide instantaneous SRH images. These developments pave the way for instantaneous label free GI histology in an intra-operative context.
△ Less
Submitted 23 February, 2019;
originally announced February 2019.
-
Arago spot formation in the time domain
Authors:
Christophe Finot,
Hervé Rigneault
Abstract:
Using the space-time duality we theoretically and experimentally revisit the Arago spot formation in the time domain and explore the temporal emergence of a bright spot in the time shadow of an initial waveform. We describe the linear regime of propagation using Fresnel's integrals and show that in the presence of Kerr nonlinearity the Arago spot formation is affected depending on the sign of the…
▽ More
Using the space-time duality we theoretically and experimentally revisit the Arago spot formation in the time domain and explore the temporal emergence of a bright spot in the time shadow of an initial waveform. We describe the linear regime of propagation using Fresnel's integrals and show that in the presence of Kerr nonlinearity the Arago spot formation is affected depending on the sign of the dispersion. We finally confirm experimentally the Arago spot formation in the time domain using a telecommunication optical fiber platform.
△ Less
Submitted 16 February, 2019;
originally announced February 2019.
-
Compressive Raman imaging with spatial frequency modulated illumination
Authors:
Camille Scotté,
Siddharth Sivankutty,
Patrick Stockton,
Randy A. Bartels,
Hervé Rigneault
Abstract:
We report a line scanning imaging modality of compressive Raman technology with spatial frequency modulated illumination using a single pixel detector. We demonstrate the imaging and classification of three different chemical species at line scan rates of 40 Hz.
We report a line scanning imaging modality of compressive Raman technology with spatial frequency modulated illumination using a single pixel detector. We demonstrate the imaging and classification of three different chemical species at line scan rates of 40 Hz.
△ Less
Submitted 11 April, 2019; v1 submitted 21 January, 2019;
originally announced January 2019.
-
High-sensitivity high-speed compressive spectrometer for Raman imaging
Authors:
Benneth Sturm,
Fernando Soldevila,
Enrique Tajahuerce,
Sylvain Gigan,
Herve Rigneault,
Hilton B. de Aguiar
Abstract:
Compressive Raman is a recent framework that allows for large data compression of microspectroscopy during its measurement. Because of its inherent multiplexing architecture, it has shown imaging speeds considerably higher than conventional Raman microspectroscopy. Nevertheless, the low signal-to-noise (SNR) of Raman scattering still poses challenges for high-sensitivity bio-imaging exploiting com…
▽ More
Compressive Raman is a recent framework that allows for large data compression of microspectroscopy during its measurement. Because of its inherent multiplexing architecture, it has shown imaging speeds considerably higher than conventional Raman microspectroscopy. Nevertheless, the low signal-to-noise (SNR) of Raman scattering still poses challenges for high-sensitivity bio-imaging exploiting compressive Raman: (i) the idle solvent acts as a background noise upon imaging small biological organelles, (ii) current compressive spectrometers are lossy precluding high-sensitivity imaging. We present inexpensive high-throughput spectrometer layouts for high-sensitivity compressive hyperspectroscopy. We exploit various modalities of compressive Raman allowing for up to 80X reduction of data storage and 2X microspectroscopy speed up at a 230-nm spatial resolution. Such achievements allowed us to chemically image sub-diffraction-limited biological specimens (lipid bilayers) in few seconds.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Compressive Sampling Approach for Image Acquisition with Lensless Endoscope
Authors:
Stéphanie Guérit,
Siddharth Sivankutty,
Camille Scotté,
John Alto Lee,
Hervé Rigneault,
Laurent Jacques
Abstract:
The lensless endoscope is a promising device designed to image tissues in vivo at the cellular scale. The traditional acquisition setup consists in raster scanning during which the focused light beam from the optical fiber illuminates sequentially each pixel of the field of view (FOV). The calibration step to focus the beam and the sampling scheme both take time. In this preliminary work, we propo…
▽ More
The lensless endoscope is a promising device designed to image tissues in vivo at the cellular scale. The traditional acquisition setup consists in raster scanning during which the focused light beam from the optical fiber illuminates sequentially each pixel of the field of view (FOV). The calibration step to focus the beam and the sampling scheme both take time. In this preliminary work, we propose a scanning method based on compressive sampling theory. The method does not rely on a focused beam but rather on the random illumination patterns generated by the single-mode fibers. Experiments are performed on synthetic data for different compression rates (from 10 to 100% of the FOV).
△ Less
Submitted 30 October, 2018; v1 submitted 29 October, 2018;
originally announced October 2018.
-
Single-shot non-interferometric measurement of the phase transmission matrix in multicore fibers
Authors:
Siddharth Sivankutty,
Viktor Tsvirkun,
Géraud Bouwmans,
Esben Ravn Andresen,
Dan Oron,
Hervé Rigneault,
Miguel A. Alonso
Abstract:
A simple technique for far-field single-shot non-interferometric determination of the phase transmission matrix of a multicore fiber with over 100 cores is presented. This phase retrieval technique relies on the aperiodic arrangement of the cores.
A simple technique for far-field single-shot non-interferometric determination of the phase transmission matrix of a multicore fiber with over 100 cores is presented. This phase retrieval technique relies on the aperiodic arrangement of the cores.
△ Less
Submitted 22 August, 2018;
originally announced August 2018.
-
Nonlinear imaging through a golden spiral multicore fiber
Authors:
Siddharth Sivankutty,
Viktor Tsvirkun,
Olivier Vanvincq,
Géraud Bouwmans,
Esben Andresen,
Hérve Rigneault
Abstract:
We report two-photon lensless imaging through a novel golden spiral multicore fiber. This unique layout optimizes the sidelobe levels, field of view, cross-talk, group delay and mode density to achieve a sidelobe contrast of atleast 10.9 dB. We demonstrate experimentally the ability to generate and scan a focal point with a femtosecond pulse and perform two-photon imaging.
We report two-photon lensless imaging through a novel golden spiral multicore fiber. This unique layout optimizes the sidelobe levels, field of view, cross-talk, group delay and mode density to achieve a sidelobe contrast of atleast 10.9 dB. We demonstrate experimentally the ability to generate and scan a focal point with a femtosecond pulse and perform two-photon imaging.
△ Less
Submitted 4 June, 2018;
originally announced June 2018.
-
Pump-probe micro-spectroscopy by means of an ultra-fast acousto-optics delay line
Authors:
Xavier Audier,
Naveen Balla,
Herve Rigneault
Abstract:
We demonstrate femtosecond pump-probe transient absorption spectroscopy using a programmable dispersive filter as an ultra-fast delay line. Combined with fast synchronous detection this delay line allows for recording of 6 ps decay traces at 34 kHz. With such acquisition speed we perform single point pump-probe spectroscopy on bulk samples in 80 $μ$s and hyperspectral pump-probe imaging over a fie…
▽ More
We demonstrate femtosecond pump-probe transient absorption spectroscopy using a programmable dispersive filter as an ultra-fast delay line. Combined with fast synchronous detection this delay line allows for recording of 6 ps decay traces at 34 kHz. With such acquisition speed we perform single point pump-probe spectroscopy on bulk samples in 80 $μ$s and hyperspectral pump-probe imaging over a field of view of 100 $μ$m in less than a second. The usability of the method is illustrated on a showcase experiment to image and discriminate two pigments in a mixture.
△ Less
Submitted 4 May, 2018;
originally announced May 2018.
-
Optical Antenna-based Fluorescence Correlation Spectroscopy to Probe the Nanoscale Dynamics of Biological Membranes
Authors:
Pamina M. Winkler,
Raju Regmi,
Valentin Flauraud,
Jürgen Brugger,
Hervé Rigneault,
Jérôme Wenger,
Maria F. Garcia-Parajo
Abstract:
The plasma membrane of living cells is compartmentalized at multiple spatial scales ranging from the nano- to the meso-scale. This non-random organization is crucial for a large number of cellular functions. At the nanoscale, cell membranes organize into dynamic nano-assemblies enriched by cholesterol, sphingolipids and certain types of proteins. Investigating these nano-assemblies known as lipid…
▽ More
The plasma membrane of living cells is compartmentalized at multiple spatial scales ranging from the nano- to the meso-scale. This non-random organization is crucial for a large number of cellular functions. At the nanoscale, cell membranes organize into dynamic nano-assemblies enriched by cholesterol, sphingolipids and certain types of proteins. Investigating these nano-assemblies known as lipid rafts is of paramount interest in fundamental cell biology. However, this goal requires simultaneous nanometer spatial precision and microsecond temporal resolution which is beyond the reach of common microscopes. Optical antennas based on metallic nanostructures efficiently enhance and confine light into nanometer dimensions, breaching the diffraction limit of light. In this Perspective, we discuss recent progress combining optical antennas with fluorescence correlation spectroscopy (FCS) to monitor microsecond dynamics at nanoscale spatial dimensions. These new developments offer numerous opportunities to investigate lipid and protein dynamics in both mimetic and native biological membranes.
△ Less
Submitted 19 December, 2017;
originally announced December 2017.
-
Transient Nanoscopic Phase Separation in Biological Lipid Membranes Resolved by Planar Plasmonic Antennas
Authors:
Pamina M. Winkler,
Raju Regmi,
Valentin Flauraud,
Jürgen Brugger,
Hervé Rigneault,
Jérôme Wenger,
María F. García-Parajo
Abstract:
Nanoscale membrane assemblies of sphingolipids, cholesterol, and certain proteins, also known as lipid rafts, play a crucial role in facilitating a broad range of important cell functions. Whereas on living cell membranes lipid rafts have been postulated to have nanoscopic dimensions and to be highly transient, the existence of a similar type of dynamic nanodomains in multicomponent lipid bilayers…
▽ More
Nanoscale membrane assemblies of sphingolipids, cholesterol, and certain proteins, also known as lipid rafts, play a crucial role in facilitating a broad range of important cell functions. Whereas on living cell membranes lipid rafts have been postulated to have nanoscopic dimensions and to be highly transient, the existence of a similar type of dynamic nanodomains in multicomponent lipid bilayers has been questioned. Here, we perform fluorescence correlation spectroscopy on planar plasmonic antenna arrays with different nanogap sizes to assess the dynamic nanoscale organization of mimetic biological membranes. Our approach takes advantage of the highly enhanced and confined excitation light provided by the nanoantennas together with their outstanding planarity to investigate membrane regions as small as 10 nm in size with microsecond time resolution. Our diffusion data are consistent with the coexistence of transient nanoscopic domains in both the liquid-ordered and the liquid-disordered microscopic phases of multicomponent lipid bilayers. These nanodomains have characteristic residence times between 30 and 150 μs and sizes around 10 nm, as inferred from the diffusion data. Thus, although microscale phase separation occurs on mimetic membranes, nanoscopic domains also coexist, suggesting that these transient assemblies might be similar to those occurring in living cells, which in the absence of raft-stabilizing proteins are poised to be short-lived. Importantly, our work underscores the high potential of photonic nanoantennas to interrogate the nanoscale heterogeneity of native biological membranes with ultrahigh spatiotemporal resolution.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Planar Optical Nanoantennas Resolve Cholesterol-Dependent Nanoscale Heterogeneities in the Plasma Membrane of Living Cells
Authors:
Raju Regmi,
Pamina M. Winkler,
Valentin Flauraud,
Kyra J. E. Borgman,
Carlo Manzo,
Jürgen Brugger,
Hervé Rigneault,
Jérôme Wenger,
María F. García-Parajo
Abstract:
Optical nanoantennas can efficiently confine light into nanoscopic hotspots, enabling single-molecule detection sensitivity at biological relevant conditions. This innovative approach to breach the diffraction limit offers a versatile platform to investigate the dynamics of individual biomolecules in living cell membranes and their partitioning into cholesterol-dependent lipid nanodomains. Here, w…
▽ More
Optical nanoantennas can efficiently confine light into nanoscopic hotspots, enabling single-molecule detection sensitivity at biological relevant conditions. This innovative approach to breach the diffraction limit offers a versatile platform to investigate the dynamics of individual biomolecules in living cell membranes and their partitioning into cholesterol-dependent lipid nanodomains. Here, we present optical nanoantenna arrays with accessible surface hotspots to study the characteristic diffusion dynamics of phosphoethanolamine (PE) and sphingomyelin (SM) in the plasma membrane of living cells at the nanoscale. Fluorescence burst analysis and fluorescence correlation spectroscopy performed on nanoantennas of different gap sizes show that, unlike PE, SM is transiently trapped in cholesterol-enriched nanodomains of 10 nm diameter with short characteristic times around 100 μs. The removal of cholesterol led to the free diffusion of SM, consistent with the dispersion of nanodomains. Our results are consistent with the existence of highly transient and fluctuating nanoscale assemblies enriched by cholesterol and sphingolipids in living cell membranes, also known as lipid rafts. Quantitative data on sphingolipids partitioning into lipid rafts is crucial to understand the spatiotemporal heterogeneous organization of transient molecular complexes on the membrane of living cells at the nanoscale. The proposed technique is fully biocompatible and thus provides various opportunities for biophysics and live cell research to reveal details that remain hidden in confocal diffraction-limited measurements.
△ Less
Submitted 17 November, 2017;
originally announced November 2017.
-
Wavefront-sensing with a thin diffuser
Authors:
Pascal Berto,
Hervé Rigneault,
Marc Guillon
Abstract:
We propose and implement a broadband, compact, and low-cost wavefront sensing scheme by simply placing a thin diffuser in the close vicinity of a camera. The local wavefront gradient is determined from the local translation of the speckle pattern. The translation vector map is computed thanks to a fast diffeomorphic image registration algorithm and integrated to reconstruct the wavefront profile.…
▽ More
We propose and implement a broadband, compact, and low-cost wavefront sensing scheme by simply placing a thin diffuser in the close vicinity of a camera. The local wavefront gradient is determined from the local translation of the speckle pattern. The translation vector map is computed thanks to a fast diffeomorphic image registration algorithm and integrated to reconstruct the wavefront profile. The simple translation of speckle grains under local wavefront tip/tilt is ensured by the so-called "memory effect" of the diffuser. Quantitative wavefront measurements are experimentally demonstrated both for the few first Zernike polynomials and for phase-imaging applications requiring high resolution. We finally provided a theoretical description of the resolution limit that is supported experimentally.
△ Less
Submitted 10 October, 2017;
originally announced October 2017.
-
Origin and suppression of parasitic signals in Kagomé lattice hollow core fibers used for SRS microscopy and endoscopy
Authors:
Alberto Lombardini,
Esben Ravn Andresen,
Alexandre Kudlinski,
Ingo Rimke,
Hervé Rigneault
Abstract:
Hollow core fibers are considered as promising candidates to deliver intense temporally overlapping picosecond pulses in applications such as stimulated Raman scattering (SRS) microscopy and endoscopy because of their inherent low nonlinearity compared to solid-core silica fibers. Here we demonstrate that, contrary to prior assumptions, parasitic signals are generated in Kagomé lattice hollow core…
▽ More
Hollow core fibers are considered as promising candidates to deliver intense temporally overlapping picosecond pulses in applications such as stimulated Raman scattering (SRS) microscopy and endoscopy because of their inherent low nonlinearity compared to solid-core silica fibers. Here we demonstrate that, contrary to prior assumptions, parasitic signals are generated in Kagomé lattice hollow core fibers. We identify the origin of the parasitic signals as an interplay between the Kerr nonlinearity of air and frequency-dependent fiber losses. Importantly, we identify the special cases of experimental parameters that are free from parasitic signals, making hollow core fibers ideal candidates for noise-free SRS microscopy and endoscopy.
△ Less
Submitted 27 September, 2017; v1 submitted 25 September, 2017;
originally announced September 2017.
-
High-resolution multimodal flexible coherent Raman endoscope
Authors:
Alberto Lombardini,
Vasyl Mytskaniuk,
Siddharth Sivankutty,
Esben Ravn Andresen,
Xueqin Chen,
Jérôme Wenger,
Marc Fabert,
Nicolas Joly,
Frédéric Louradour,
Alexandre Kudlinski,
Hervé Rigneault
Abstract:
Coherent Raman scattering microscopy is a fast, label-free and chemically specific imaging technique that has a high potential for future in-vivo optical histology. However, its imaging depth into tissues is limited to the sub-millimeter range by absorption and scattering. Performing coherent Raman imaging in a fiber endoscope system is a crucial step to image deep inside living tissues and provid…
▽ More
Coherent Raman scattering microscopy is a fast, label-free and chemically specific imaging technique that has a high potential for future in-vivo optical histology. However, its imaging depth into tissues is limited to the sub-millimeter range by absorption and scattering. Performing coherent Raman imaging in a fiber endoscope system is a crucial step to image deep inside living tissues and provide the information inaccessible with current microscopy tools. However the development of coherent Raman endoscopy has been hampered by several issues in the fiber delivery of the excitation pulses and signal collection. Here, we present a flexible, compact, and multimodal nonlinear endoscope (4.2 mm outer diameter, 71 mm rigid length) based on a resonantly scanned hollow-core Kagomé-lattice double-clad fiber. The fiber design allows distortion-less, background-free delivery of femtosecond excitation pulses and the back-collection of nonlinear signals through the same fiber. Sub-micron spatial resolution together with large field of view is made possible by the combination of a miniature objective lens together with a silica microsphere lens inserted into the fiber core. We demonstrate coherent anti-Stokes Raman scattering, 2-photon fluorescence and second harmonic generation imaging with 0.8 μm resolution over a field of view up to 320 μm and at a rate of 0.8 frames/s. These results pave the way for intra-operative label-free imaging applied to real-time histopathology diagnosis and surgery guidance.
△ Less
Submitted 11 August, 2017;
originally announced August 2017.
-
Widefield lensless endoscopy with a multicore fiber
Authors:
Viktor Tsvirkun,
Siddharth Sivankutty,
Géraud Bouwmans,
Ori Katz,
Esben Ravn Andresen,
Hervé Rigneault
Abstract:
We demonstrate pixelation-free real-time widefield endoscopic imaging through an aperiodic multicore fiber (MCF) without any distal opto-mechanical elements or proximal scanners. Exploiting the memory effect in MCFs the images in our system are directly obtained without any post-processing using a static wavefront correction obtained from a single calibration procedure. Our approach allows for vid…
▽ More
We demonstrate pixelation-free real-time widefield endoscopic imaging through an aperiodic multicore fiber (MCF) without any distal opto-mechanical elements or proximal scanners. Exploiting the memory effect in MCFs the images in our system are directly obtained without any post-processing using a static wavefront correction obtained from a single calibration procedure. Our approach allows for video-rate 3D widefield imaging of incoherently illuminated objects with imaging speed not limited by the wavefront shaping device refresh rate.
△ Less
Submitted 23 November, 2016;
originally announced November 2016.
-
Complementary Speckle Patterns : deterministic interchange of intrinsic vortices and maxima through Scattering Media
Authors:
Jérôme Gateau,
Hervé Rigneault,
Marc Guillon
Abstract:
Intensity minima and maxima of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge $\pm 1$ to the impinging coherent beam. This transform arises from the intuitive expectation that a tightly focused beam is so-changed into a vortex beam and vice-versa. The statistics of extrema locations and the intensity distribution of the so-gen…
▽ More
Intensity minima and maxima of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge $\pm 1$ to the impinging coherent beam. This transform arises from the intuitive expectation that a tightly focused beam is so-changed into a vortex beam and vice-versa. The statistics of extrema locations and the intensity distribution of the so-generated "complementary" patterns are characterized by numerical simulations. It is demonstrated experimentally that the incoherent superposition of the three "complementary speckle patterns" yield a synthetic speckle grain size enlarged by a factor $\sqrt{3}$. A cyclic permutation of optical vortices and maxima is unexpectedly observed and discussed.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
Extended field-of-view in a lensless endoscope using an aperiodic multicore fiber
Authors:
Siddharth Sivankutty,
Viktor Tsvirkun,
Géraud Bouwmans,
Dani Kogan,
Dan Oron,
Esben Ravn Andresen,
Hervé Rigneault
Abstract:
We investigate lensless endoscopy using coherent beam combining and aperiodic multicore fibers (MCF). We show that diffracted orders, inherent to MCF with periodically arranged cores, dramatically reduce the field of view (FoV) and that randomness in MCF core positions can increase the FoV up to the diffraction limit set by a single fiber core, while maintaining MCF experimental feasibility. We de…
▽ More
We investigate lensless endoscopy using coherent beam combining and aperiodic multicore fibers (MCF). We show that diffracted orders, inherent to MCF with periodically arranged cores, dramatically reduce the field of view (FoV) and that randomness in MCF core positions can increase the FoV up to the diffraction limit set by a single fiber core, while maintaining MCF experimental feasibility. We demonstrate experimentally pixelation-free lensless endoscopy imaging over a 120 micron FoV with an aperiodic MCF designed with widely spaced cores. We show that this system is suitable to perform beam scanning imaging by simply applying a tilt to the proximal wavefront.
△ Less
Submitted 27 June, 2016;
originally announced June 2016.
-
Single shot polarimetry imaging of multicore fiber
Authors:
Siddharth Sivankutty,
Esben Ravn Andresen,
Géraud Bouwmans,
Thomas G. Brown,
Miguel A. Alonso,
Hérve Rigneault
Abstract:
We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element together with an analyzer and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this tec…
▽ More
We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element together with an analyzer and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single mode fiber cores in both conventional and polarization-maintaining bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual ber core including eigen-polarization states, phase delay and diattenuation.
△ Less
Submitted 5 April, 2016;
originally announced April 2016.
-
Widefield lensless endoscopy via speckle-correlations
Authors:
Amir Porat,
Esben Ravn Andresen,
Hervé Rigneault,
Dan Oron,
Sylvain Gigan,
Ori Katz
Abstract:
Flexible fiber-optic endoscopes provide a minimally-invasive solution for imaging at depths beyond the reach of conventional microscopes. Current endoscopes require focusing and/or scanning mechanisms at the distal end, which limit miniaturization and frame-rate, and induce aberrations. Alternative lensless solutions are based on adaptive wavefront-correction, but are extremely sensitive to fiber…
▽ More
Flexible fiber-optic endoscopes provide a minimally-invasive solution for imaging at depths beyond the reach of conventional microscopes. Current endoscopes require focusing and/or scanning mechanisms at the distal end, which limit miniaturization and frame-rate, and induce aberrations. Alternative lensless solutions are based on adaptive wavefront-correction, but are extremely sensitive to fiber bending. Here, we demonstrate a novel endoscopic approach, which enables single-shot imaging at a variable working distance through a conventional fiber bundle, without the use of any distal optics. Our approach computationally retrieves the object image from a single speckle pattern transmitted through the bundle, exploiting phase information preserved through inherent angular speckle correlations. Unlike conventional fiber-bundle endoscopes, the resulting image is unpixelated, the resolution is diffraction-limited, objects can be imaged at variable working distance, and the technique is completely insensitive to fiber bending. Since no optical elements are required, miniaturization is limited only by the bundle diameter.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.
-
Direct imaging of molecular symmetry by coherent anti-Stokes Raman scattering
Authors:
Carsten Cleff,
Alicja Gasecka,
Patrick Ferrand,
Hervé Rigneault,
Sophie Brasselet,
Julien Duboisset
Abstract:
Nonlinear optical methods, such as coherent anti-Stokes Raman scattering (CARS) and stimulated Raman scattering (SRS), are able to perform label free imaging, with chemical bonds specificity. Here, we demonstrate that the use of circularly polarized light allows to retrieve not only the chemical nature but also the symmetry of the probed sample, in a single shot measurement. Our symmetry-resolved…
▽ More
Nonlinear optical methods, such as coherent anti-Stokes Raman scattering (CARS) and stimulated Raman scattering (SRS), are able to perform label free imaging, with chemical bonds specificity. Here, we demonstrate that the use of circularly polarized light allows to retrieve not only the chemical nature but also the symmetry of the probed sample, in a single shot measurement. Our symmetry-resolved scheme offers simple access to the local organization of vibrational bonds and as a result provides enhanced image contrast for anisotropic samples as well as an improved chemical selectivity. We quantify the local organization of vibrational bonds on crystalline and biological samples, thus providing new information not accessible by spontaneous Raman and SRS techniques. This work stands for a novel symmetry-resolved contrast in vibrational microscopy, with potential application in biological diagnostic.
△ Less
Submitted 13 November, 2015;
originally announced November 2015.
-
Ultra-thin rigid endoscope: Two-photon imaging through a graded-index multi-mode fiber
Authors:
Siddharth Sivankutty,
Esben Ravn Andresen,
Rosa Cossart,
Géraud Bouwmans,
Serge Monneret,
Hervé Rigneault
Abstract:
Rigid endoscopes like graded-index (GRIN) lenses are known tools in biological imaging, but it is conceptually difficult to miniaturize them. In this letter, we demonstrate an ultra-thin rigid endoscope with a diameter of only 125 microns. In addition, we identify a domain where two-photon endoscopic imaging with fs-pulse excitation is possible. We validate the ultra-thin rigid endoscope consistin…
▽ More
Rigid endoscopes like graded-index (GRIN) lenses are known tools in biological imaging, but it is conceptually difficult to miniaturize them. In this letter, we demonstrate an ultra-thin rigid endoscope with a diameter of only 125 microns. In addition, we identify a domain where two-photon endoscopic imaging with fs-pulse excitation is possible. We validate the ultra-thin rigid endoscope consisting of a few cm of graded-index multi-mode fiber by using it to acquire optically sectioned two-photon fluorescence endoscopic images of three-dimensional samples.
△ Less
Submitted 16 October, 2015;
originally announced October 2015.
-
Plasmonic antennas and zero mode waveguides to enhance single molecule fluorescence detection and fluorescence correlation spectroscopy towards physiological concentrations
Authors:
Deep Punj,
Petru Ghenuche,
Satish Babu Moparthi,
Juan de Torres,
Victor Grigoriev,
Hervé Rigneault,
Jérôme Wenger
Abstract:
Single-molecule approaches to biology offer a powerful new vision to elucidate the mechanisms that underpin the functioning of living cells. However, conventional optical single molecule spectroscopy techniques such as Förster fluorescence resonance energy transfer (FRET) or fluorescence correlation spectroscopy (FCS) are limited by diffraction to the nanomolar concentration range, far below the p…
▽ More
Single-molecule approaches to biology offer a powerful new vision to elucidate the mechanisms that underpin the functioning of living cells. However, conventional optical single molecule spectroscopy techniques such as Förster fluorescence resonance energy transfer (FRET) or fluorescence correlation spectroscopy (FCS) are limited by diffraction to the nanomolar concentration range, far below the physiological micromolar concentration range where most biological reaction occur. To breach the diffraction limit, zero mode waveguides and plasmonic antennas exploit the surface plasmon resonances to confine and enhance light down to the nanometre scale. The ability of plasmonics to achieve extreme light concentration unlocks an enormous potential to enhance fluorescence detection, FRET and FCS. Single molecule spectroscopy techniques greatly benefit from zero mode waveguides and plasmonic antennas to enter a new dimension of molecular concentration reaching physiological conditions. The application of nano-optics to biological problems with FRET and FCS is an emerging and exciting field, and is promising to reveal new insights on biological functions and dynamics.
△ Less
Submitted 6 March, 2014;
originally announced March 2014.
-
Excitation Enhancement of a Quantum Dot Coupled to a Plasmonic Antenna
Authors:
E. Bermudez Urena,
M. P. Kreuzer,
S. Itzhakov,
H. Rigneault,
R. Quidant,
D. Oron,
J. Wenger
Abstract:
Plasmonic antennas are key elements to control the luminescence of quantum emitters. However, the antenna's influence is often hidden by quenching losses. Here, the luminescence of a quantum dot coupled to a gold dimer antenna is investigated. Detailed analysis of the multiply excited states quantifies the antenna's influence on the excitation intensity and the luminescence quantum yield separatel…
▽ More
Plasmonic antennas are key elements to control the luminescence of quantum emitters. However, the antenna's influence is often hidden by quenching losses. Here, the luminescence of a quantum dot coupled to a gold dimer antenna is investigated. Detailed analysis of the multiply excited states quantifies the antenna's influence on the excitation intensity and the luminescence quantum yield separately.
△ Less
Submitted 27 November, 2012;
originally announced November 2012.
-
FCS diffusion laws on two-phases lipid membranes : experimental and Monte-carlo simulation determination of domain size
Authors:
C. Favard,
J. Ehrig,
J. Wenger,
P. -F. Lenne,
H. Rigneault
Abstract:
For more than ten years now, many efforts have been done to identify and characterize nature of obstructed diffusion in model and cellular lipid membranes. Amongst all the techniques developed for this purpose, FCS, by means of determination of FCS diffusion laws, has been shown to be a very efficient approach. In this paper, FCS diffusion laws are used to probe the behavior of a pure lipid and a…
▽ More
For more than ten years now, many efforts have been done to identify and characterize nature of obstructed diffusion in model and cellular lipid membranes. Amongst all the techniques developed for this purpose, FCS, by means of determination of FCS diffusion laws, has been shown to be a very efficient approach. In this paper, FCS diffusion laws are used to probe the behavior of a pure lipid and a lipid mixture at temperatures below and above phase transitions, both numerically, using a full thermodynamic model, and experimentally. In both cases FCS diffusion laws exhibit deviation from free diffusion and reveal the existence of domains. The variation of these domains mean size with temperature is in perfect correlation with the enthalpy fluctuation.
△ Less
Submitted 3 May, 2010;
originally announced May 2010.
-
A versatile dual spot laser scanning confocal microscopy system for advanced fluorescence correlation spectroscopy analysis in living cell
Authors:
P. Ferrand,
M. Pianta,
A. Kress,
A. Aillaud,
H. Rigneault,
D. Marguet
Abstract:
A fluorescence correlation spectroscopy (FCS) system based on two independent measurement volumes is presented. The optical setup and data acquisition hardware are detailed, as well as a complete protocol to control the location, size and shape of the measurement volumes. A method that allows to monitor independently the excitation and collection efficiency distribution is proposed. Finally, a f…
▽ More
A fluorescence correlation spectroscopy (FCS) system based on two independent measurement volumes is presented. The optical setup and data acquisition hardware are detailed, as well as a complete protocol to control the location, size and shape of the measurement volumes. A method that allows to monitor independently the excitation and collection efficiency distribution is proposed. Finally, a few examples of measurements that exploit the two spots in static and/or scanning schemes, are reported.
△ Less
Submitted 29 July, 2009;
originally announced July 2009.
-
Radiative and non-radiative photokinetics alteration inside a single metallic nanometric aperture
Authors:
Jerome Wenger,
Benoit Cluzel,
Jose Dintinger,
Nicolas Bonod,
Anne-Laure Fehrembach,
Evgeny Popov,
Pierre-Francois Lenne,
Thomas W. Ebbesen,
Herve Rigneault
Abstract:
We resolve the photokinetic rates enhancement of Rhodamine 6G molecules diffusing in a water-glycerol mixture within a single nanometric aperture milled in an opaque aluminium film. Combining fluorescence correlation spectroscopy and lifetime measurements, we report the relative influence of excitation, radiative and non-radiative decay in the fluorescence process, giving a detailed description…
▽ More
We resolve the photokinetic rates enhancement of Rhodamine 6G molecules diffusing in a water-glycerol mixture within a single nanometric aperture milled in an opaque aluminium film. Combining fluorescence correlation spectroscopy and lifetime measurements, we report the relative influence of excitation, radiative and non-radiative decay in the fluorescence process, giving a detailed description of the physics behind the overall 15 fold enhancement of the average fluorescence rate per molecule. This procedure is broadly adaptable to a wide range of nanostructures.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.
-
Influence of the Raman depolarisation ratio on far-field radiation patterns in coherent anti-Stokes Raman scattering (CARS) microscopy
Authors:
D. Gachet,
N. Sandeau,
H. Rigneault
Abstract:
We propose a full-vectorial numerical study of far field radiation patterns in coherent anti-Stokes Raman scattering (CARS) microscopy. We emphasis the particular role of the Raman depolarisation ratio of the observed medium and show how it modifies the radiation pattern of thin objects.
We propose a full-vectorial numerical study of far field radiation patterns in coherent anti-Stokes Raman scattering (CARS) microscopy. We emphasis the particular role of the Raman depolarisation ratio of the observed medium and show how it modifies the radiation pattern of thin objects.
△ Less
Submitted 6 October, 2006;
originally announced October 2006.
-
Far-field radiation pattern in Coherent Anti-stokes Raman Scattering (CARS) Microscopy
Authors:
D. Gachet,
N. Sandeau,
H. Rigneault
Abstract:
Far field radiation pattern under tight focusing condition is investigated in Coherent Anti-stokes Raman Scattering (CARS) microscopy both in the forward (F-CARS) and backward (E-CARS) directions. While we assume no refraction index mismatch between the sample and the environing medium, our rigorous numerical electromagnetic computation takes into account the exact polarizations of the excitatio…
▽ More
Far field radiation pattern under tight focusing condition is investigated in Coherent Anti-stokes Raman Scattering (CARS) microscopy both in the forward (F-CARS) and backward (E-CARS) directions. While we assume no refraction index mismatch between the sample and the environing medium, our rigorous numerical electromagnetic computation takes into account the exact polarizations of the excitation laser beams and of the induced nonlinear dipoles. F-CARS and E-CARS radiation patterns, as well as their divergence, are studied as a function of the size of the sample object and compared to the excitation beams.
△ Less
Submitted 8 June, 2006;
originally announced June 2006.
-
Axial localization of luminophores by partial coherence interferometry
Authors:
Nicolas Sandeau,
Hervé Rigneault,
Pierre François Lenne,
Hugues Giovannini,
the Mosaic Collaboration
Abstract:
We propose a solution for increasing the axial resolution of confocal microscopes. In the experimental set-up described in this paper an interference phenomenon between two counterpropagating beams is used to determine the axial position of a luminophore. The optical path difference between the two waves, which is related to the position of the luminophore, is recovered thanks to a second interf…
▽ More
We propose a solution for increasing the axial resolution of confocal microscopes. In the experimental set-up described in this paper an interference phenomenon between two counterpropagating beams is used to determine the axial position of a luminophore. The optical path difference between the two waves, which is related to the position of the luminophore, is recovered thanks to a second interferometer by using partial coherence interferometry demodulation technique. The proposed solution can find applications in biology for localizing with nanometric resolution a small number of tagged species.
△ Less
Submitted 8 June, 2006;
originally announced June 2006.