Non-unique water and contrast agent solutions in dual-energy CT
Authors:
JP Phillips,
Emil Y. Sidky,
Fatma Terzioglu,
Ingrid S. Reiser,
Guillaume Bal,
Xiaochuan Pan
Abstract:
The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity dat…
▽ More
The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity data for practical thickness ranges of water and contrast agent. Once existence is identified, non-unique solutions are found by simulating scan data and finding intensity contours with that intersect multiple times. With this process non-unique solutions are found for DECT setups scanning iodine and gadolinium, including setups using tube potentials in practical ranges. Non-unique solutions demonstrate a large range of differences and can result in significant discrepancies between recovered and true material mapping.
△ Less
Submitted 19 November, 2024;
originally announced November 2024.
-
A directional total variation minimization algorithm for isotropic resolution in digital breast tomosynthesis
Authors:
Emil Y. Sidky,
Xiangyi Wu,
Xiaoyu Duan,
Hailing Huang,
Wei Zhao,
Leo Y. Zhang,
John Paul Phillips,
Zheng Zhang,
Buxin Chen,
Dan Xia,
Ingrid S. Reiser,
Xiaochuan Pan
Abstract:
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction.…
▽ More
An optimization-based image reconstruction algorithm is developed for contrast enhanced digital breast tomosynthesis (DBT) using dual-energy scanning. The algorithm minimizes directional total variation (TV) with a data discrepancy and non-negativity constraints. Iodinated contrast agent (ICA) imaging is performed by reconstructing images from dual-energy DBT data followed by weighted subtraction. Physical DBT data is acquired with a Siemens Mammomat scanner of a structured breast phantom with ICA inserts. Results are shown for both directional TV minimization and filtered back-projection for reference. It is seen that directional TV is able to substantially reduce depth blur for the ICA objects.
△ Less
Submitted 11 June, 2024;
originally announced June 2024.
-
Enhancing signal detectability in learning-based CT reconstruction with a model observer inspired loss function
Authors:
Megan Lantz,
Emil Y. Sidky,
Ingrid S. Reiser,
Xiaochuan Pan,
Gregory Ongie
Abstract:
Deep neural networks used for reconstructing sparse-view CT data are typically trained by minimizing a pixel-wise mean-squared error or similar loss function over a set of training images. However, networks trained with such pixel-wise losses are prone to wipe out small, low-contrast features that are critical for screening and diagnosis. To remedy this issue, we introduce a novel training loss in…
▽ More
Deep neural networks used for reconstructing sparse-view CT data are typically trained by minimizing a pixel-wise mean-squared error or similar loss function over a set of training images. However, networks trained with such pixel-wise losses are prone to wipe out small, low-contrast features that are critical for screening and diagnosis. To remedy this issue, we introduce a novel training loss inspired by the model observer framework to enhance the detectability of weak signals in the reconstructions. We evaluate our approach on the reconstruction of synthetic sparse-view breast CT data, and demonstrate an improvement in signal detectability with the proposed loss.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
A signal detection model for quantifying over-regularization in non-linear image reconstruction
Authors:
Emil Y. Sidky,
John Paul Phillips,
Weimin Zhou,
Greg Ongie,
Juan Cruz-Bastida,
Ingrid S. Reiser,
Mark A. Anastasio,
Xiaochuan Pan
Abstract:
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regu…
▽ More
Purpose: Many useful image quality metrics for evaluating linear image reconstruction techniques do not apply to or are difficult to interpret for non-linear image reconstruction. The vast majority of metrics employed for evaluating non-linear image reconstruction are based on some form of global image fidelity, such as image root mean square error (RMSE). Use of such metrics can lead to over-regularization in the sense that they can favor removal of subtle details in the image. To address this shortcoming, we develop an image quality metric based on signal detection that serves as a surrogate to the qualitative loss of fine image details. Methods: The metric is demonstrated in the context of a breast CT simulation, where different equal-dose configurations are considered. The configurations differ in the number of projections acquired. Image reconstruction is performed with a non-linear algorithm based on total variation constrained least-squares (TV-LSQ). The images are evaluated visually, with image RMSE, and with the proposed signal-detection based metric. The latter uses a small signal, and computes detectability in the sinogram and in the reconstructed image. Loss of signal detectability through the image reconstruction process is taken as a quantitative measure of loss of fine details in the image. Results: Loss of signal detectability is seen to correlate well with the blocky or patchy appearance due to over-regularization with TV-LSQ, and this trend runs counter to the image RMSE metric, which tends to favor the over-regularized images. Conclusions: The proposed signal detection based metric provides an image quality assessment that is complimentary to that of image RMSE. Using the two metrics in concert may yield a useful prescription for determining CT algorithm and configuration parameters when non-linear image reconstruction is used.
△ Less
Submitted 8 December, 2020; v1 submitted 7 October, 2020;
originally announced October 2020.
-
Toward optimal X-ray flux utilization in breast CT
Authors:
Jakob H. Joergensen,
Per Christian Hansen,
Emil Y. Sidky,
Ingrid S. Reiser,
Xiaochuan Pan
Abstract:
A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained, TV-minimization problem, which has received much interest recently for sparse-view CT data.
A realistic computer-simulation of a breast computed tomography (CT) system and subject is constructed. The model is used to investigate the optimal number of views for the scan given a fixed total X-ray fluence. The reconstruction algorithm is based on accurate solution to a constrained, TV-minimization problem, which has received much interest recently for sparse-view CT data.
△ Less
Submitted 8 April, 2011;
originally announced April 2011.
-
Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
Authors:
Emil Y. Sidky,
Xiaochuan Pan,
Ingrid S. Reiser,
Robert M. Nishikawa,
Richard H. Moore,
Daniel B. Kopans
Abstract:
PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT).
METHOD: The algorithm controls image regularity by minimizing the image total $p$-variation (TpV), a function that reduces to the total variation when $p=1.0$ or the image roughness when $p=2.0$. Constraints on the image, such as image…
▽ More
PURPOSE: We develop a practical, iterative algorithm for image-reconstruction in under-sampled tomographic systems, such as digital breast tomosynthesis (DBT).
METHOD: The algorithm controls image regularity by minimizing the image total $p$-variation (TpV), a function that reduces to the total variation when $p=1.0$ or the image roughness when $p=2.0$. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets (POCS). The fact that the tomographic system is under-sampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) reduction of the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in under-sampled tomography.
RESULTS: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses.
CONCLUSION: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.
△ Less
Submitted 7 April, 2009;
originally announced April 2009.