-
The GlueX Beamline and Detector
Authors:
S. Adhikari,
C. S. Akondi,
H. Al Ghoul,
A. Ali,
M. Amaryan,
E. G. Anassontzis,
A. Austregesilo,
F. Barbosa,
J. Barlow,
A. Barnes,
E. Barriga,
R. Barsotti,
T. D. Beattie,
J. Benesch,
V. V. Berdnikov,
G. Biallas,
T. Black,
W. Boeglin,
P. Brindza,
W. J. Briscoe,
T. Britton,
J. Brock,
W. K. Brooks,
B. E. Cannon,
C. Carlin
, et al. (165 additional authors not shown)
Abstract:
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based…
▽ More
The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 $μ$s. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
△ Less
Submitted 26 October, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
The Central Drift Chamber for GlueX
Authors:
N. S. Jarvis,
C. A. Meyer,
B. Zihlmann,
M. Staib,
A. Austregesilo,
F. Barbosa,
C. Dickover,
V. Razmyslovich,
S. Taylor,
Y. Van Haarlem,
G. Visser,
T. Whitlatch
Abstract:
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discu…
▽ More
The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as 0.25 GeV/c as well as to identify low-momentum protons via energy loss. The construction of the detector is described and its operation and calibration are discussed in detail. The design goal of 150 microns in position resolution has been reached.
△ Less
Submitted 27 February, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
The transverse momentum dependence of charged kaon Bose-Einstein correlations in the SELEX experiment
Authors:
SELEX Collaboration,
G. A. Nigmatkulov,
A. K. Ponosov,
U. Akgun,
G. Alkhazov,
J. Amaro-Reyes,
A. Asratyan,
A. G. Atamantchouk,
A. S. Ayan,
M. Y. Balatz,
A. Blanco-Covarrubias,
N. F. Bondar,
P. S. Cooper,
L. J. Dauwe,
G. V. Davidenko,
U. Dersch,
A. G. Dolgolenko,
G. B. Dzyubenko,
R. Edelstein,
L. Emediato,
A. M. F. Endler,
J. Engelfried,
I. Eschrich,
C. O. Escobar,
N. Estrada
, et al. (79 additional authors not shown)
Abstract:
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlatio…
▽ More
We report on the measurement of the one-dimensional charged kaon correlation functions using 600~GeV/{\it c} $Σ^-$, $π^-$ and 540~GeV/{\it c} $p$ beams from the SELEX~(E781) experiment at the Fermilab Tevatron. $K^{\pm}K^{\pm}$ correlation functions are studied for three transverse pair momentum, $k_T$, ranges and parameterized by a Gaussian form. The emission source radii, $R$, and the correlation strength, $λ$, are extracted. The analysis shows a decrease of the source radii with increasing kaon transverse pair momentum for all beam types.
△ Less
Submitted 14 November, 2015; v1 submitted 18 January, 2015;
originally announced January 2015.
-
The GlueX Central Drift Chamber: Design and Performance
Authors:
Y. Van Haarlem,
C. A. Meyer,
F. Barbosa,
B. Dey,
D. Lawrence,
V. Razmyslovich,
E. Smith,
G. Visser,
T. Whitlatch,
G. Wilkin,
B. Zihlmann
Abstract:
Tests and studies concerning the design and performance of the GlueX Central Drift
Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo si…
▽ More
Tests and studies concerning the design and performance of the GlueX Central Drift
Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.
△ Less
Submitted 21 April, 2010;
originally announced April 2010.