-
Calibration of a $Δ$E-E telescope based on CeBr$_3$ scintillator for secondary charged particles measurements in hadron therapy
Authors:
L. Gesson,
J. Gross,
C. Mozzi,
C. Reibel,
Ch. Finck,
S. Higueret,
T. D. Le,
E. Traykov,
J. C. Thomas,
N. Arbor,
M. Pullia,
G. Harmant,
M. Vanstalle
Abstract:
Hadrontherapy is a promising cancer treatment method that offers better dose conformity and reduces damage to healthy tissues compared to conventional radiotherapy. However, one major challenge remaining is the precise characterization of secondary particles generated by nuclear interactions of the primary beam with tissues. Current data on secondary charged particles, such as protons and light io…
▽ More
Hadrontherapy is a promising cancer treatment method that offers better dose conformity and reduces damage to healthy tissues compared to conventional radiotherapy. However, one major challenge remaining is the precise characterization of secondary particles generated by nuclear interactions of the primary beam with tissues. Current data on secondary charged particles, such as protons and light ions, remain insufficient, particularly in the clinically relevant energy ranges. This lack of experimental data introduces uncertainties in treatment planning softwares and Monte Carlo calculations, thus compromising the accuracy of dose delivery to the patients. This work consists in the characterization of secondary charged particles generated in hadron therapy using a $Δ$E-E telescope comprising a CeBr$_3$ crystal scintillator and a plastic scintillator. The calibration and response of this telescope to ions commonly used in clinical settings is presented in this work, highlighting adherence to Birks law for accurate energy measurements. This study is the first to optimize a $Δ$E-E telescope combining CeBr$_3$ and plastic scintillators specifically for secondary particle detection in hadrontherapy. This represents an important step in the exploitation of the system for nuclear data acquisition, as it enables both the measurement of energy and the discrimination of secondary particles. The objective is to develop a system compatible with clinical use, allowing for the most precise possible comparison with treatment planning software calculations.
△ Less
Submitted 7 February, 2025;
originally announced February 2025.
-
Cross Section Measurements of Large Angle Fragments Production in the Interaction of Carbon Ion Beams with Thin Targets
Authors:
The FOOT Collaboration,
Y. Dong,
I. Mattei,
A. Alexandrov,
B. Alpat,
G. Ambrosi,
S. Argirò,
M. Barbanera,
N. Bartosik,
G. Battistoni,
M. G. Bisogni,
V. Boccia,
F. Cavanna,
P. Cerello,
E. Ciarrocchi,
A. De Gregorio,
G. De Lellis,
A. Di Crescenzo,
B. Di Ruzza,
M. Dondi,
M. Donetti,
M. Durante,
R. Faccini,
V. Ferrero,
C. Finck
, et al. (65 additional authors not shown)
Abstract:
The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at 90$^{\text{o}}$ and 60$^{\text{o}}$ at the CNAO particle therapy center (Pavia, Italy). The presented measurements are a complete reanalysis by the FOOT collaboration of a…
▽ More
The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at 90$^{\text{o}}$ and 60$^{\text{o}}$ at the CNAO particle therapy center (Pavia, Italy). The presented measurements are a complete reanalysis by the FOOT collaboration of already published elemental cross section on composite targets, in order to refine the analysis, improve the systematic uncertainties and show the comparison with the FLUKA Monte Carlo code calculations. In this work, the kinetic energy at production of measured fragments has been completely redefined, together with the efficiencies computation. The new analysis strategy has been successfully validated against the Monte Carlo cross sections. Two detection arms were positioned at two different angles to perform the measurement at 90$^{\text{o}}$ and 60$^{\text{o}}$. The fragment species have been identified in charge (Z$_{id}$ = H) and mass (M$_{id}$ = $^1$H, $^2$H, $^3$H) combining the information of the deposited energy in thin plastic scintillators, of the deposited energy in a thick LYSO crystal and of the fragments Time of Flight (ToF) measurement. The ToF was also used to compute the fragments measured kinetic energy. The cross sections are presented as a function of the fragments kinetic energy at production thanks to an unfolding technique applied to the data.
△ Less
Submitted 8 January, 2025;
originally announced January 2025.
-
Angular differential and elemental fragmentation cross sections of a $400\,\text{MeV/nucleon}$ $^{16}\text{O}$ beam on a graphite target with the FOOT experiment
Authors:
FOOT Collaboration,
R. Ridolfi,
M. Toppi,
A. Mengarelli,
M. Dondi,
A. Alexandrov,
B. Alpat,
G. Ambrosi,
S. Argirò,
M. Barbanera,
N. Bartosik,
G. Battistoni,
M. G. Bisogni,
V. Boccia,
F. Cavanna,
P. Cerello,
E. Ciarrocchi,
A. De Gregorio,
G. De Lellis,
A. Di Crescenzo,
B. Di Ruzza,
M. Donetti,
Y. Dong,
M. Durante,
R. Faccini
, et al. (66 additional authors not shown)
Abstract:
This paper presents the measurements of the angular differential cross sections for the forward production of He, Li, Be, B, C and N nuclei in the fragmentation process of a 400$\text{MeV/nucleon}$ $^{16}\text{O}$ beam interacting with a graphite target. Due to the limited data available in this energy regime, these measurements of nuclear fragmentation cross sections are relevant to improve nucle…
▽ More
This paper presents the measurements of the angular differential cross sections for the forward production of He, Li, Be, B, C and N nuclei in the fragmentation process of a 400$\text{MeV/nucleon}$ $^{16}\text{O}$ beam interacting with a graphite target. Due to the limited data available in this energy regime, these measurements of nuclear fragmentation cross sections are relevant to improve nuclear interaction models for Particle Therapy and space radioprotection applications. The data analyzed in this paper were collected during a measurement campaign carried out at the GSI Helmholtz Center for Heavy Ion Research facility in Darmstadt (Germany) by the FOOT collaboration. The results are compared with similar results found in the literature and with a previous FOOT measurement of the same process, using the same setup, from a previous pilot run performed at GSI. The pilot run data, however, had limited statistics and only allowed for the measurement of elemental fragmentation cross sections integrated in the setup acceptance. This data set, with statistics more than 100 times larger compared to the data collected in the previous run, enabled the measurement of angular differential cross sections, fully exploiting the granularity of the FOOT $Δ\text{E}$-TOF system. Furthermore, a better comprehension of the FOOT apparatus allowed to improve the analysis techniques, leading to a reduction in the final systematic uncertainties.
△ Less
Submitted 9 June, 2025; v1 submitted 31 December, 2024;
originally announced January 2025.
-
The muon beam monitor for the FAMU experiment: design, simulation, test and operation
Authors:
R. Rossini,
G. Baldazzi,
S. Banfi,
M. Baruzzo,
R. Benocci,
R. Bertoni,
M. Bonesini,
S. Carsi,
D. Cirrincione,
M. Clemenza,
L. Colace,
A. de Bari,
C. de Vecchi,
E. Fasci,
R. Gaigher,
L. Gianfrani,
A. D. Hillier,
K. Ishida,
P. J. C. King,
J. S. Lord,
R. Mazza,
A. Menegolli,
E. Mocchiutti,
S. Monzani,
L. Moretti
, et al. (13 additional authors not shown)
Abstract:
FAMU is an INFN-led muonic atom physics experiment based at the RIKEN-RAL muon facility at the ISIS Neutron and Muon Source (United Kingdom). The aim of FAMU is to measure the hyperfine splitting in muonic hydrogen to determine the value of the proton Zemach radius with accuracy better than 1%.The experiment has a scintillating-fibre hodoscope for beam monitoring and data normalisation. In order t…
▽ More
FAMU is an INFN-led muonic atom physics experiment based at the RIKEN-RAL muon facility at the ISIS Neutron and Muon Source (United Kingdom). The aim of FAMU is to measure the hyperfine splitting in muonic hydrogen to determine the value of the proton Zemach radius with accuracy better than 1%.The experiment has a scintillating-fibre hodoscope for beam monitoring and data normalisation. In order to carry out muon flux estimation, low-rate measurements were performed to extract the single-muon average deposited charge. Then, detector simulation in Geant4 and FLUKA allowed a thorough understanding of the single-muon response function, crucial for determining the muon flux. This work presents the design features of the FAMU beam monitor, along with the simulation and absolute calibration measurements in order to enable flux determination and enable data normalisation.
△ Less
Submitted 8 October, 2024;
originally announced October 2024.
-
Status of the detector setup for the FAMU experiment at RIKEN-RAL for a precision measurement of the Zemach radius of the proton in muonic hydrogen
Authors:
R. Rossini,
A. Adamczak,
D. Bakalov,
G. Baldazzi,
S. Banfi,
M. Baruzzo,
R. Benocci,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
H. Cabrera,
S. Carsi,
D. Cirrincione,
M. Clemenza,
L. Colace,
M. B. Danailov,
P. Danev,
A. de Bari,
C. de Vecchi,
E. Fasci,
K. S. Gadedjisso-Tossou,
R. Gaigher,
L. Gianfrani,
A. D. Hillier,
K. Ishida
, et al. (24 additional authors not shown)
Abstract:
The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition.…
▽ More
The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition. The experiment has started its data taking in July 2023. The status of the detector setup for the 2023 experimental runs, for the beam characterisation and muonic X-ray detection in the 100-200 keV energy range, is presented and discussed.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Characterisation of a low-momentum high-rate muon beam monitor for the FAMU experiment at the CNAO-XPR beam facility
Authors:
Riccardo Rossini,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Stefano Carsi,
Massimiliano Clemenza,
Antonio de Bari,
Marco Donetti,
Carlo de Vecchi,
Alessandro Menegolli,
Alessio Mereghetti,
Emiliano Mocchiutti,
Christian Petroselli,
Marco Cesare Prata,
Marco Pullia,
Gian Luca Raselli,
Massimo Rossella,
Simone Savazzi,
Ludovico Tortora,
Erik Silvio Vallazza
Abstract:
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of t…
▽ More
The FAMU experiment aims at an indirect measurement of the Zemach radius of the proton. The measurement is carried out on muonic hydrogen atoms produced through the low-momentum (50-60 MeV/c) muon beam a the RIKEN-RAL negative muon facility. The particle flux plays an important role in this measurement, as it is proportional to the number of muonic hydrogen atoms produced, which is the target of the FAMU experimental method. The beam monitor calibration technique and results, presented here, are meant to extract a reliable estimation of the muon flux during the FAMU data taking. These measurements were carried out at the CNAO synchrotron in Pavia, Italy, using proton beams and supported by Monte Carlo simulation of the detector in Geant4.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
The FragmentatiOn Of Target Experiment (FOOT) and its DAQ system
Authors:
Silvia Biondi,
Andrey Alexandrov,
Behcet Alpat,
Giovanni Ambrosi,
Stefano Argirò,
Rau Arteche Diaz,
Nazarm Bartosik,
Giuseppe Battistoni,
Nicola Belcari,
Elettra Bellinzona,
Maria Giuseppina Bisogni,
Graziano Bruni,
Pietro Carra,
Piergiorgio Cerello,
Esther Ciarrocchi,
Alberto Clozza,
Sofia Colombi,
Giovanni De Lellis,
Alberto Del Guerra,
Micol De Simoni,
Antonia Di Crescenzo,
Benedetto Di Ruzza,
Marco Donetti,
Yunsheng Dong,
Marco Durante
, et al. (70 additional authors not shown)
Abstract:
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experim…
▽ More
The FragmentatiOn Of Target (FOOT) experiment aims to provide precise nuclear cross-section measurements for two different fields: hadrontherapy and radio-protection in space. The main reason is the important role the nuclear fragmentation process plays in both fields, where the health risks caused by radiation are very similar and mainly attributable to the fragmentation process. The FOOT experiment has been developed in such a way that the experimental setup is easily movable and fits the space limitations of the experimental and treatment rooms available in hadrontherapy treatment centers, where most of the data takings are carried out. The Trigger and Data Acquisition system needs to follow the same criteria and it should work in different laboratories and in different conditions. It has been designed to acquire the largest sample size with high accuracy in a controlled and online-monitored environment. The data collected are processed in real-time for quality assessment and are available to the DAQ crew and detector experts during data taking.
△ Less
Submitted 29 October, 2020;
originally announced October 2020.
-
Beam test characterisation of a Plastic Scintillator Prototype for the space-based cosmic ray experiment HERD
Authors:
P. W. Cattaneo,
M. Pullia,
M. C. Prata,
A. Rappoldi,
M. Rossella
Abstract:
The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and c…
▽ More
The High Energy cosmic-Radiation Detector (HERD) facility is planned to go onboard China's Space Station, planned to be operational starting in around 2025 for about 10 years. The main scientific objectives of HERD are the search for signals of dark matter annihilation products, precise cosmic electron/positron spectrum and measurements of anisotropy up to 10 TeV, precise cosmic ray spectrum and composition measurements up to the knee energy (1 PeV), and high energy $γ$-ray monitoring and survey. HERD consists of a 3D cubic crystals calorimeter (CALO) surrounded by microstrip silicon trackers (STKs) and scintillating fiber trackers (FIT) and by a Plastic Scintillator Detector (PSD) for $γ$-ray veto and ion charge measurement. A PSD prototype consisting of a scintillator tile readout by two arrays of SiPMs on opposite sides has been tested with proton and C ion beam at the CNAO (Centro Nazionale Adroterapia Oncologica) in Pavia, (Italy). Preliminary results on charge resolution are presented.
△ Less
Submitted 20 May, 2020;
originally announced May 2020.
-
First tests for an online treatment monitoring system with in-beam PET for proton therapy
Authors:
Aafke C. Kraan,
G. Battistoni,
N. Belcari,
N. Camarlinghi,
F. Cappucci,
M. Ciocca,
A. Ferrari,
S. Ferretti,
A. Mairani,
S. Molinelli,
M. Pullia,
A. Retico,
P. Sala,
G. Sportelli,
A. Del Guerra,
V. Rosso
Abstract:
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype Do…
▽ More
PET imaging is a non-invasive technique for particle range verification in proton therapy. It is based on measuring the beta+ annihilations caused by nuclear interactions of the protons in the patient. In this work we present measurements for proton range verification in phantoms, performed at the CNAO particle therapy treatment center in Pavia, Italy, with our 10 x 10 cm^2 planar PET prototype DoPET. PMMA phantoms were irradiated with mono-energetic proton beams and clinical treatment plans, and PET data were acquired during and shortly after proton irradiation. We created 1-D profiles of the beta+ activity along the proton beam-axis, and evaluated the difference between the proximal rise and the distal fall-off position of the activity distribution. A good agreement with FLUKA Monte Carlo predictions was obtained. We also assessed the system response when the PMMA phantom contained an air cavity. The system was able to detect these cavities quickly after irradiation.
△ Less
Submitted 26 November, 2014;
originally announced November 2014.