-
Brain Tumor Segmentation (BraTS) Challenge 2024: Meningioma Radiotherapy Planning Automated Segmentation
Authors:
Dominic LaBella,
Katherine Schumacher,
Michael Mix,
Kevin Leu,
Shan McBurney-Lin,
Pierre Nedelec,
Javier Villanueva-Meyer,
Jonathan Shapey,
Tom Vercauteren,
Kazumi Chia,
Omar Al-Salihi,
Justin Leu,
Lia Halasz,
Yury Velichko,
Chunhao Wang,
John Kirkpatrick,
Scott Floyd,
Zachary J. Reitman,
Trey Mullikin,
Ulas Bagci,
Sean Sachdev,
Jona A. Hattangadi-Gluth,
Tyler Seibert,
Nikdokht Farid,
Connor Puett
, et al. (45 additional authors not shown)
Abstract:
The 2024 Brain Tumor Segmentation Meningioma Radiotherapy (BraTS-MEN-RT) challenge aims to advance automated segmentation algorithms using the largest known multi-institutional dataset of radiotherapy planning brain MRIs with expert-annotated target labels for patients with intact or postoperative meningioma that underwent either conventional external beam radiotherapy or stereotactic radiosurgery…
▽ More
The 2024 Brain Tumor Segmentation Meningioma Radiotherapy (BraTS-MEN-RT) challenge aims to advance automated segmentation algorithms using the largest known multi-institutional dataset of radiotherapy planning brain MRIs with expert-annotated target labels for patients with intact or postoperative meningioma that underwent either conventional external beam radiotherapy or stereotactic radiosurgery. Each case includes a defaced 3D post-contrast T1-weighted radiotherapy planning MRI in its native acquisition space, accompanied by a single-label "target volume" representing the gross tumor volume (GTV) and any at-risk postoperative site. Target volume annotations adhere to established radiotherapy planning protocols, ensuring consistency across cases and institutions. For preoperative meningiomas, the target volume encompasses the entire GTV and associated nodular dural tail, while for postoperative cases, it includes at-risk resection cavity margins as determined by the treating institution. Case annotations were reviewed and approved by expert neuroradiologists and radiation oncologists. Participating teams will develop, containerize, and evaluate automated segmentation models using this comprehensive dataset. Model performance will be assessed using an adapted lesion-wise Dice Similarity Coefficient and the 95% Hausdorff distance. The top-performing teams will be recognized at the Medical Image Computing and Computer Assisted Intervention Conference in October 2024. BraTS-MEN-RT is expected to significantly advance automated radiotherapy planning by enabling precise tumor segmentation and facilitating tailored treatment, ultimately improving patient outcomes.
△ Less
Submitted 15 August, 2024; v1 submitted 28 May, 2024;
originally announced May 2024.
-
Fluid registration between lung CT and stationary chest tomosynthesis images
Authors:
Lin Tian,
Connor Puett,
Peirong Liu,
Zhengyang Shen,
Stephen R. Aylward,
Yueh Z. Lee,
Marc Niethammer
Abstract:
Registration is widely used in image-guided therapy and image-guided surgery to estimate spatial correspondences between organs of interest between planning and treatment images. However, while high-quality computed tomography (CT) images are often available at planning time, limited angle acquisitions are frequently used during treatment because of radiation concerns or imaging time constraints.…
▽ More
Registration is widely used in image-guided therapy and image-guided surgery to estimate spatial correspondences between organs of interest between planning and treatment images. However, while high-quality computed tomography (CT) images are often available at planning time, limited angle acquisitions are frequently used during treatment because of radiation concerns or imaging time constraints. This requires algorithms to register CT images based on limited angle acquisitions. We, therefore, formulate a 3D/2D registration approach which infers a 3D deformation based on measured projections and digitally reconstructed radiographs of the CT. Most 3D/2D registration approaches use simple transformation models or require complex mathematical derivations to formulate the underlying optimization problem. Instead, our approach entirely relies on differentiable operations which can be combined with modern computational toolboxes supporting automatic differentiation. This then allows for rapid prototyping, integration with deep neural networks, and to support a variety of transformation models including fluid flow models. We demonstrate our approach for the registration between CT and stationary chest tomosynthesis (sDCT) images and show how it naturally leads to an iterative image reconstruction approach.
△ Less
Submitted 6 March, 2022;
originally announced March 2022.
-
Practical large-scale spatio-temporal modeling of particulate matter concentrations
Authors:
Christopher J. Paciorek,
Jeff D. Yanosky,
Robin C. Puett,
Francine Laden,
Helen H. Suh
Abstract:
The last two decades have seen intense scientific and regulatory interest in the health effects of particulate matter (PM). Influential epidemiological studies that characterize chronic exposure of individuals rely on monitoring data that are sparse in space and time, so they often assign the same exposure to participants in large geographic areas and across time. We estimate monthly PM during 1…
▽ More
The last two decades have seen intense scientific and regulatory interest in the health effects of particulate matter (PM). Influential epidemiological studies that characterize chronic exposure of individuals rely on monitoring data that are sparse in space and time, so they often assign the same exposure to participants in large geographic areas and across time. We estimate monthly PM during 1988--2002 in a large spatial domain for use in studying health effects in the Nurses' Health Study. We develop a conceptually simple spatio-temporal model that uses a rich set of covariates. The model is used to estimate concentrations of $PM_{10}$ for the full time period and $PM_{2.5}$ for a subset of the period. For the earlier part of the period, 1988--1998, few $PM_{2.5}$ monitors were operating, so we develop a simple extension to the model that represents $PM_{2.5}$ conditionally on $PM_{10}$ model predictions. In the epidemiological analysis, model predictions of $PM_{10}$ are more strongly associated with health effects than when using simpler approaches to estimate exposure. Our modeling approach supports the application in estimating both fine-scale and large-scale spatial heterogeneity and capturing space--time interaction through the use of monthly-varying spatial surfaces. At the same time, the model is computationally feasible, implementable with standard software, and readily understandable to the scientific audience. Despite simplifying assumptions, the model has good predictive performance and uncertainty characterization.
△ Less
Submitted 8 June, 2009;
originally announced June 2009.