3D-printed axicon enables extended depth-of-focus intravascular optical coherence tomography
Authors:
Pavel Ruchka,
Alok Kushwaha,
Jessica A. Marathe,
Lei Xiang,
Rouyan Chen,
Rodney Kirk,
Joanne T. M. Tan,
Christina A. Bursill,
Johan Verjans,
Simon Thiele,
Robert Fitridge,
Robert A. McLaughlin,
Peter J. Psaltis,
Harald Giessen,
Jiawen Li
Abstract:
A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs…
▽ More
A fundamental challenge in endoscopy is how to fabricate a small fiber-optic probe that can achieve comparable function to probes with large, complicated optics (e.g., high resolution and extended depth of focus). To achieve high resolution over an extended depth of focus (DOF), the application of needle-like beams has been proposed. However, existing methods using miniaturized needle beam designs fail to adequately correct astigmatism and other monochromatic aberrations, limiting the resolution of at least one axis. Here, we describe a novel approach to realize freeform beam-shaping endoscopic probes via two-photon direct laser writing, also known as micro 3D-printing. We present a design achieving approximately 8-micron resolution with a DOF of >0.8 mm at a central wavelength of 1310 nm. The probe has a diameter of 0.25 mm (without the catheter sheaths) and is fabricated using a single printing step directly on the optical fiber. We demonstrate our device in intravascular imaging of living atherosclerotic pigs at multiple time points, as well as human arteries with plaques ex vivo. This is the first step to enable beam-tailoring endoscopic probes which achieve diffraction-limited resolution over a large DOF.
△ Less
Submitted 20 July, 2024;
originally announced July 2024.
Evaluating the severity of tandem coronary stenoses: Insights from simulated FFR and iFR techniques
Authors:
Navid Freidoonimehr,
Tam Atkins,
Jessica A. Marathe,
Peter J. Psaltis,
Maziar Arjomandi
Abstract:
Aims: The presence of coronary tandem lesions poses a significant challenge for the accurate diagnosis and management of coronary artery diseases. This study set out to provide a deeper understanding of the haemodynamic interactions between tandem obstructive coronary lesions and their impact on different haemodynamic diagnostic parameters. Methods and Results: Using a computational fluid dynamic…
▽ More
Aims: The presence of coronary tandem lesions poses a significant challenge for the accurate diagnosis and management of coronary artery diseases. This study set out to provide a deeper understanding of the haemodynamic interactions between tandem obstructive coronary lesions and their impact on different haemodynamic diagnostic parameters. Methods and Results: Using a computational fluid dynamic model, validated against in vitro laboratory experiments, we investigated the various combinations of moderate and severe stenoses interchangeably located in the proximal and distal segments of the artery. The investigation was conducted using two diagnostic parameters: one hyperaemic-based, i.e., FFR, and one rest-based, i.e., iFR, technique, both of which are commonly used to assess the physiological significance of coronary stenoses. The three main findings of this work are: (a) the recovery distance (the immediate local distance affected by the presence of stenosis) is much shorter for the rest-measured diagnostic parameter compared with the hyperaemic-measured diagnostic parameter; (b) pressure drop measurements immediately downstream of the stenotic sections overestimate the significance of stenoses, and (c) the presence of a moderate stenosis downstream of a severe stenosis increases FFR value (faster FFR recovery). Conclusion: These findings enhance our understanding of the diagnostic accuracy of hyperaemic-based and rest-based physiological diagnostic coronary assessments and the nuances of using these different techniques when assessing tandem coronary stenoses. This understanding can help inform tailored therapeutic approaches for the management of coronary artery disease.
△ Less
Submitted 7 July, 2024;
originally announced July 2024.