Impact of friction force and retrieval speed on in silico mechanical thrombectomies: a sensitivity analysis
Authors:
Mahesh S. Nagargoje,
Virginia Fregona,
Giulia Luraghi,
Francesco Migliavacca,
Demitria A Poulos,
Bryan C Good,
Jose Felix Rodriguez Matas
Abstract:
Background: Mechanical Thrombectomy (MT) is a widely accepted first-line treatment for Acute Ischemic Stroke (AIS) and it has been studied using in vitro and in silico models. Thrombectomy outcomes have been performed for patient-specific cases using in silico models. However, until now, in vivo friction coefficients for stent-vessel, stent-clot, and clot-vessel interactions are unknown, but in vi…
▽ More
Background: Mechanical Thrombectomy (MT) is a widely accepted first-line treatment for Acute Ischemic Stroke (AIS) and it has been studied using in vitro and in silico models. Thrombectomy outcomes have been performed for patient-specific cases using in silico models. However, until now, in vivo friction coefficients for stent-vessel, stent-clot, and clot-vessel interactions are unknown, but in vitro experiments have been attempted with significant standard deviations. These interactions and friction coefficients have been considered an important aspect of thrombectomy success. Objectives: In the current study, we explored the influence of variation in friction forces for stent-vessel, stent-clot, and clot-vessel interactions using virtual mechanical thrombectomy (VMT). We have performed three simulations for each interaction and varied friction coefficients around the standard deviation observed in the past in vitro studies. Results: (i) clot-vessel friction: higher friction leads to clot fragmentation and VMT failure. (ii) stent-clot friction: it is susceptible to VMT outcomes, with lower values showing the slippage of the clot while higher values lead to fragmentation. (iii) stent-vessel friction: higher friction shows compression of the stent in curved vessels and dislodgment of clot from stent retriever (SR) due to its compression, which leads to VMT failure. (iv) retrieval speed (RS): higher RS (>30 mm/s) leads to significant stent compression and unrealistic behavior of the SR. Conclusions: Analysis of results proposes the necessity for calculating accurate friction factor values and their implementation into in silico models, due to their sensitivity towards thrombectomy outcomes. Such in silico models mimic in vivo thrombectomy more closely and can be used in mechanical thrombectomy planning, management, and decision-making.
△ Less
Submitted 4 June, 2025;
originally announced June 2025.
Grover's algorithm in a four-qubit silicon processor above the fault-tolerant threshold
Authors:
Ian Thorvaldson,
Dean Poulos,
Christian M. Moehle,
Saiful H. Misha,
Hermann Edlbauer,
Jonathan Reiner,
Helen Geng,
Benoit Voisin,
Michael T. Jones,
Matthew B. Donnelly,
Luis F. Pena,
Charles D. Hill,
Casey R. Myers,
Joris G. Keizer,
Yousun Chung,
Samuel K. Gorman,
Ludwik Kranz,
Michelle Y. Simmons
Abstract:
Spin qubits in silicon are strong contenders for realizing a practical quantum computer. This technology has made remarkable progress with the demonstration of single and two-qubit gates above the fault-tolerant threshold and entanglement of up to three qubits. However, maintaining high fidelity operations while executing multi-qubit algorithms has remained elusive, only being achieved for two spi…
▽ More
Spin qubits in silicon are strong contenders for realizing a practical quantum computer. This technology has made remarkable progress with the demonstration of single and two-qubit gates above the fault-tolerant threshold and entanglement of up to three qubits. However, maintaining high fidelity operations while executing multi-qubit algorithms has remained elusive, only being achieved for two spin qubits to date due to the small qubit size, which makes it difficult to control qubits without creating crosstalk errors. Here, we use a four-qubit silicon processor with every operation above the fault tolerant limit and demonstrate Grover's algorithm with a ~95% probability of finding the marked state, one of the most successful implementations to date. Our four-qubit processor is made of three phosphorus atoms and one electron spin precision-patterned into 1.5 nm${}^2$ isotopically pure silicon. The strong resulting confinement potential, without additional confinement gates that can increase cross-talk, leverages the benefits of having both electron and phosphorus nuclear spins. Significantly, the all-to-all connectivity of the nuclear spins provided by the hyperfine interaction not only allows for efficient multi-qubit operations, but also provides individual qubit addressability. Together with the long coherence times of the nuclear and electron spins, this results in all four single qubit fidelities above 99.9% and controlled-Z gates between all pairs of nuclear spins above 99% fidelity. The high control fidelities, combined with >99% fidelity readout of all nuclear spins, allows for the creation of a three-qubit Greenberger-Horne-Zeilinger (GHZ) state with 96.2% fidelity, the highest reported for semiconductor spin qubits so far. Such nuclear spin registers can be coupled via electron exchange, establishing a path for larger scale fault-tolerant quantum processors.
△ Less
Submitted 2 March, 2025; v1 submitted 12 April, 2024;
originally announced April 2024.