-
Room Temperature, Quantum-Limited THz Heterodyne Detection? Not Yet
Authors:
J. Zmuidzinas,
B. Karasik,
A. R. Kerr,
M. Pospieszalski
Abstract:
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could…
▽ More
In their article, Wang et al. [1] report a new scheme for THz heterodyne detection using a laser-driven LTG-GaAs photomixer [2, 3] and make the impressive claim of achieving near quantum-limited sensitivity at room temperature. Unfortunately, their experimental methodology is incorrect, and furthermore the paper provides no information on the mixer conversion loss, an important quantity that could readily have been measured and reported as a consistency check. The paper thus offers no reliable experimental evidence that substantiates the claimed sensitivities. To the contrary, the very high value reported for their photomixer impedance strongly suggests that the conversion loss is quite poor and that the actual sensitivity is far worse than claimed.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
The Atacama Large Millimeter/submillimeter Array (ALMA) Band-1 Receiver
Authors:
Yau De Huang,
Oscar Morata,
Patrick Michel Koch,
Ciska Kemper,
Yuh-Jing Hwang,
Chau-Ching Chiong,
Paul Ho,
You-Hua Chu,
Chi-Den Huang,
Ching-Tang Liu,
Fang-Chia Hsieh,
Yen-Hsiang Tseng,
Shou-Hsien Weng,
Chin-Ting Ho,
Po-Han Chiang,
Hsiao-Ling Wu,
Chih-Cheng Chang,
Shou-Ting Jian,
Chien-Feng Lee,
Yi-Wei Lee,
Satoru Iguchi,
Shin'ichiro Asayama,
Daisuke Iono,
Alvaro Gonzalez,
John Effland
, et al. (7 additional authors not shown)
Abstract:
The Atacama Large Millimeter/submillimeter Array(ALMA) Band 1 receiver covers the 35-50 GHz frequency band. Development of prototype receivers, including the key components and subsystems has been completed and two sets of prototype receivers were fully tested. We will provide an overview of the ALMA Band 1 science goals, and its requirements and design for use on the ALMA. The receiver developmen…
▽ More
The Atacama Large Millimeter/submillimeter Array(ALMA) Band 1 receiver covers the 35-50 GHz frequency band. Development of prototype receivers, including the key components and subsystems has been completed and two sets of prototype receivers were fully tested. We will provide an overview of the ALMA Band 1 science goals, and its requirements and design for use on the ALMA. The receiver development status will also be discussed and the infrastructure, integration, evaluation of fully-assembled band 1 receiver system will be covered. Finally, a discussion of the technical and management challenges encountered will be presented.
△ Less
Submitted 2 December, 2016;
originally announced December 2016.
-
The GBT 67 -- 93.6 GHz Spectral Line Survey of Orion-KL
Authors:
D. T. Frayer,
Ronald J. Maddalena,
M. Meijer,
L. Hough,
S. White,
R. Norrod,
G. Watts,
M. Stennes,
R. Simon,
D. Woody,
S. Srikanth,
M. Pospieszalski,
E. Bryerton,
M. Whitehead,
P. Ford,
M. Mello,
M. Bloss
Abstract:
We present a 67--93.6 GHz spectral line survey of Orion-KL with the new 4 mm Receiver on the Green Bank Telescope (GBT). The survey reaches unprecedented depths and covers the low-frequency end of the 3 mm atmospheric window which has been relatively unexplored previously. The entire spectral-line survey is published electronically for general use by the astronomical community. The calibration and…
▽ More
We present a 67--93.6 GHz spectral line survey of Orion-KL with the new 4 mm Receiver on the Green Bank Telescope (GBT). The survey reaches unprecedented depths and covers the low-frequency end of the 3 mm atmospheric window which has been relatively unexplored previously. The entire spectral-line survey is published electronically for general use by the astronomical community. The calibration and performance of 4 mm Receiver on the GBT is also summarized.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
A blind detection of a large, complex, Sunyaev--Zel'dovich structure
Authors:
AMI Consortium,
:,
T. W. Shimwell,
R. W. Barker,
P. Biddulph,
D. Bly,
R. C. Boysen,
A. R. Brown,
M. L. Brown,
C. Clementson,
M. Crofts,
T. L. Culverhouse,
J. Czeres,
R. J. Dace,
M. L. Davies,
R. D'Alessandro,
P. Doherty,
K. Duggan,
J. A. Ely,
M. Felvus,
F. Feroz,
W. Flynn,
T. M. O. Franzen,
J. Geisbusch,
R. Genova-Santos
, et al. (36 additional authors not shown)
Abstract:
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have been observed down to our target sensitivity of 100μJy/beam. In follow-up deep pointed observations the SZ effect is detected with a maximum peak decrement greater than 8 \times the thermal noise. No corresponding emission is visible in the ROSAT…
▽ More
We present an interesting Sunyaev-Zel'dovich (SZ) detection in the first of the Arcminute Microkelvin Imager (AMI) 'blind', degree-square fields to have been observed down to our target sensitivity of 100μJy/beam. In follow-up deep pointed observations the SZ effect is detected with a maximum peak decrement greater than 8 \times the thermal noise. No corresponding emission is visible in the ROSAT all-sky X-ray survey and no cluster is evident in the Palomar all-sky optical survey. Compared with existing SZ images of distant clusters, the extent is large (\approx 10') and complex; our analysis favours a model containing two clusters rather than a single cluster. Our Bayesian analysis is currently limited to modelling each cluster with an ellipsoidal or spherical beta-model, which do not do justice to this decrement. Fitting an ellipsoid to the deeper candidate we find the following. (a) Assuming that the Evrard et al. (2002) approximation to Press & Schechter (1974) correctly gives the number density of clusters as a function of mass and redshift, then, in the search area, the formal Bayesian probability ratio of the AMI detection of this cluster is 7.9 \times 10^4:1; alternatively assuming Jenkins et al. (2001) as the true prior, the formal Bayesian probability ratio of detection is 2.1 \times 10^5:1. (b) The cluster mass is MT,200 = 5.5+1.2\times 10^14h-1M\odot. (c) Abandoning a physical model with num- -1.3 70 ber density prior and instead simply modelling the SZ decrement using a phenomenological β-model of temperature decrement as a function of angular distance, we find a central SZ temperature decrement of -295+36 μK - this allows for CMB primary anisotropies, receiver -15 noise and radio sources. We are unsure if the cluster system we observe is a merging system or two separate clusters.
△ Less
Submitted 22 March, 2012; v1 submitted 20 December, 2010;
originally announced December 2010.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
Authors:
R. J. Davis,
A. Wilkinson,
R. D. Davies,
W. F. Winder,
N. Roddis,
E. J. Blackhurst,
D. Lawson,
S. R. Lowe,
C. Baines,
M. Butlin,
A. Galtress,
D. Shepherd,
B. Aja,
E. Artal,
M. Bersanelli,
R. C. Butler,
C. Castelli,
F. Cuttaia,
O. D'Arcangelo,
T. Gaier,
R. Hoyland,
D. Kettle,
R. Leonardi,
N. Mandolesi,
A. Mennella
, et al. (6 additional authors not shown)
Abstract:
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo…
▽ More
We give a description of the design, construction and testing of the 30 and 44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the Planck mission to be launched in 2009. The scientific requirements of the mission determine the performance parameters to be met by the FEMs, including their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in which the signal from the sky is compared with a 4-K blackbody load. The Low Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel phase-switch design which gives excellent amplitude and phase match across the band.
The noise temperature requirements are met within the measurement errors at the two frequencies. For the most sensitive LNAs, the noise temperature at the band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively. For some of the FEMs, the noise temperature is still falling as the ambient temperature is reduced to 20 K. Stability tests of the FEMs, including a measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all critical aspects. The most sensitive LNAs have reached new limits of noise temperature for HEMTs at their band centres. The FEMs have well-defined linear polarization characteristcs.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Large Instrument Development for Radio Astronomy
Authors:
J. R. Fisher,
R. F. Bradley,
W. F. Brisken,
W. D. Cotton,
D. T. Emerson,
A. R. Kerr,
R. J. Lacasse,
M. A. Morgan,
P. J. Napier,
R. D. Norrod,
J. M. Payne,
M. W. Pospieszalski,
A. Symmes,
A. R. Thompson,
J. C. Webber
Abstract:
This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instr…
▽ More
This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.
△ Less
Submitted 26 August, 2009;
originally announced August 2009.
-
Cosmological Results from Five Years of 30 GHz CMB Intensity Measurements with the Cosmic Background Imager
Authors:
J. L. Sievers,
B. S. Mason,
L. Weintraub,
C. Achermann,
P. Altamirano,
J. R. Bond,
L. Bronfman,
R. Bustos,
C. Contaldi,
C. Dickinson,
M. E. Jones,
J. May,
S. T. Myers,
N. Oyarce,
S. Padin,
T. J. Pearson,
M. Pospieszalski,
A. C. S. Readhead,
R. Reeves,
M. C. Shepherd,
A. C. Taylor,
S. Torres
Abstract:
We present final results on the angular power spectrum of total intensity anisotropies in the CMB from the CBI. Our analysis includes all primordial anisotropy data collected between January 2000 and April 2005, and benefits significantly from an improved maximum likelihood analysis pipeline. It also includes results from a 30 GHz foreground survey conducted with the Green Bank Telescope (GBT) w…
▽ More
We present final results on the angular power spectrum of total intensity anisotropies in the CMB from the CBI. Our analysis includes all primordial anisotropy data collected between January 2000 and April 2005, and benefits significantly from an improved maximum likelihood analysis pipeline. It also includes results from a 30 GHz foreground survey conducted with the Green Bank Telescope (GBT) which places significant constraints on the possible contamination due to foreground point sources. We improve on previous CBI results by about a factor of two in the damping tail. These data confirm, at ~3-sigma, the existence of an excess of power over intrinsic CMB anisotropy on small angular scales (l > 1800). Using the GBT survey, we find currently known radio source populations are not capable of generating the power; a new population of faint sources with steeply rising spectral indices would be required to explain the excess with sources... We also present a full cosmological parameter analysis of the new CBI power spectrum... With CBI alone, the full parameter analysis finds the excess is 1.6-sigma above the level expected for a sigma_8=0.8 universe. We find the addition of high-l CMB data substantially improves constraints on cosmic string contributions to the TT power spectrum as well as the running of the scalar spectral index... We also present forecasts for what other experiments should see at different frequencies and angular resolutions given the excess power observed by CBI. We find that the reported high-l bandpowers from current high resolution CMB bolometer experiments are consistent with each other and CBI if the excess power is due to the SZE at the CBI-level of 2.5 +/- 1 times the sigma_8=0.8 standard SZ template. <Abridged>
△ Less
Submitted 5 February, 2009; v1 submitted 28 January, 2009;
originally announced January 2009.
-
Implications of the Cosmic Background Imager Polarization Data
Authors:
J. L. Sievers,
C. Achermann,
J. R. Bond,
L. Bronfman,
R. Bustos,
C. R. Contaldi,
C. Dickinson,
P. G. Ferreira,
M. E. Jones,
A. M. Lewis,
B. S. Mason,
J. May,
S. T. Myers,
S. Padin,
T. J. Pearson,
M. Pospieszalski,
A. C. S. Readhead,
R. Reeves,
A. C. Taylor,
S. Torres
Abstract:
We present new measurements of the power spectra of the E-mode of CMB polarization, the temperature T, the cross-correlation of E and T, and upper limits on the B-mode from 2.5 years of dedicated Cosmic Background Imager (CBI) observations. Both raw maps and optimal signal images in the uv-plane and real space show strong detections of the E-mode (11.7 sigma for the EE power spectrum overall) an…
▽ More
We present new measurements of the power spectra of the E-mode of CMB polarization, the temperature T, the cross-correlation of E and T, and upper limits on the B-mode from 2.5 years of dedicated Cosmic Background Imager (CBI) observations. Both raw maps and optimal signal images in the uv-plane and real space show strong detections of the E-mode (11.7 sigma for the EE power spectrum overall) and no detection of the B-mode. The power spectra are used to constrain parameters of the flat tilted adiabatic Lambda-CDM models: those determined from EE and TE bandpowers agree with those from TT, a powerful consistency check. There is little tolerance for shifting polarization peaks from the TT-forecast locations, as measured by the angular sound crossing scale theta = 100 ell_s = 1.03 +/- 0.02 from EE and TE cf. 1.044 +/- 0.005 with the TT data included. The scope for extra out-of-phase peaks from subdominant isocurvature modes is also curtailed. The EE and TE measurements of CBI, DASI and BOOMERANG are mutually consistent, and, taken together rather than singly, give enhanced leverage for these tests.
△ Less
Submitted 9 November, 2006; v1 submitted 8 September, 2005;
originally announced September 2005.
-
Polarization Observations with the Cosmic Background Imager
Authors:
A. C. S. Readhead,
S. T. Myers,
T. J. Pearson,
J. L. Sievers,
B. S. Mason,
C. R. Contaldi,
J. R. Bond,
R. Bustos,
P. Altamirano,
C. Achermann,
L. Bronfman,
J. E. Carlstrom,
J. K. Cartwright,
S. Casassus,
C. Dickinson,
W. L. Holzapfel,
J. M. Kovac,
E. M. Leitch,
J. May,
S. Padin,
D. Pogosyan,
M. Pospieszalski,
C. Pryke,
R. Reeves,
M. C. Shepherd
, et al. (1 additional authors not shown)
Abstract:
Polarization observations of the cosmic microwave background with the Cosmic Background Imager from September 2002 to May 2004 provide a significant detection of the E-mode polarization and reveal an angular power spectrum of polarized emission showing peaks and valleys that are shifted in phase by half a cycle relative to those of the total intensity spectrum. This key agreement between the pha…
▽ More
Polarization observations of the cosmic microwave background with the Cosmic Background Imager from September 2002 to May 2004 provide a significant detection of the E-mode polarization and reveal an angular power spectrum of polarized emission showing peaks and valleys that are shifted in phase by half a cycle relative to those of the total intensity spectrum. This key agreement between the phase of the observed polarization spectrum and that predicted based on the total intensity spectrum provides support for the standard model of cosmology, in which dark matter and dark energy are the dominant constituents, the geometry is close to flat, and primordial density fluctuations are predominantly adiabatic with a matter power spectrum commensurate with inflationary cosmological models.
△ Less
Submitted 28 October, 2004; v1 submitted 23 September, 2004;
originally announced September 2004.
-
Design, Implementation and Testing of the MAP Radiometers
Authors:
N. Jarosik,
C. L. Bennett,
M. Halpern,
G. Hinshaw,
A. Kogut,
M. Limon,
S. S. Meyer,
L. Page,
M. Pospieszalski,
D. N. Spergel,
G. S. Tucker,
D. T. Wilkinson,
E. Wollack,
E. L. Wright,
Z. Zhang
Abstract:
The Microwave Anisotropy Probe (MAP) satellite, launched June 30, 2001, will produce full sky maps of the cosmic microwave background radiation in 5 frequency bands spanning 20 - 106 GHz. MAP contains 20 differential radiometers built with High Electron Mobility Transistor (HEMT) amplifiers with passively cooled input stages. The design and test techniques used to evaluate and minimize systemati…
▽ More
The Microwave Anisotropy Probe (MAP) satellite, launched June 30, 2001, will produce full sky maps of the cosmic microwave background radiation in 5 frequency bands spanning 20 - 106 GHz. MAP contains 20 differential radiometers built with High Electron Mobility Transistor (HEMT) amplifiers with passively cooled input stages. The design and test techniques used to evaluate and minimize systematic errors and the pre-launch performance of the radiometers for all five bands are presented.
△ Less
Submitted 24 February, 2003; v1 submitted 10 January, 2003;
originally announced January 2003.