-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km
Authors:
H. Hachisu,
M. Fujieda,
S. Nagano,
T. Gotoh,
A. Nogami,
T. Ido,
St. Falke,
N. Huntemann,
C. Grebing,
B. Lipphardt,
Ch. Lisdat,
D. Piester
Abstract:
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fra…
▽ More
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.
△ Less
Submitted 12 July, 2014; v1 submitted 25 March, 2014;
originally announced March 2014.
-
Carrier-phase Two-Way Satellite Frequency Transfer over a Very Long Baseline
Authors:
M Fujieda,
D Piester,
T Gotoh,
J Becker,
M Aida,
A Bauch
Abstract:
In this paper we report that carrier-phase two-way satellite time and frequency transfer (TWSTFT) was successfully demonstrated over a very long baseline of 9,000 km, established between the National Institute of Information and Communications Technology (NICT) and the Physikalisch-Technische Bundesanstalt (PTB). We verified that the carrier-phase TWSTFT (TWCP) result agreed with those obtained by…
▽ More
In this paper we report that carrier-phase two-way satellite time and frequency transfer (TWSTFT) was successfully demonstrated over a very long baseline of 9,000 km, established between the National Institute of Information and Communications Technology (NICT) and the Physikalisch-Technische Bundesanstalt (PTB). We verified that the carrier-phase TWSTFT (TWCP) result agreed with those obtained by conventional TWSTFT and GPS carrier-phase (GPSCP) techniques. Moreover, a much improved short-term instability for frequency transfer of $2\times10^{-13}$ at 1 s was achieved, which is at the same level as previously confirmed over a shorter baseline within Japan. The precision achieved was so high that the effects of ionospheric delay became significant which are ignored in conventional TWSTFT even over a long link. We compensated for these effects using ionospheric delays computed from regional vertical total electron content maps. The agreement between the TWCP and GPSCP results was improved because of this compensation.
△ Less
Submitted 13 March, 2014;
originally announced March 2014.
-
Time transfer through optical fibers over a distance of 73 km with an uncertainty below 100 ps
Authors:
M. Rost,
D. Piester,
W. Yang,
T. Feldmann,
T. Wübbena,
A. Bauch
Abstract:
We demonstrate the capability of accurate time transfer using optical fibers over long distances utilizing a dark fiber and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fiber (TTTOF) system is a variant of the standard TWSTFT by employing an optical fiber in the transmission path instead of free-space transmission o…
▽ More
We demonstrate the capability of accurate time transfer using optical fibers over long distances utilizing a dark fiber and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fiber (TTTOF) system is a variant of the standard TWSTFT by employing an optical fiber in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fiber there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip-rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared to satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universitaet Hannover, Institut fuer Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1-sigma uncertainty of the GPS link results, which is estimated as 0.72 ns. The fiber link exhibits a nearly 10-fold improved stability compared to the GPS link, and assessment of its performance has been limited by the properties of the passive maser.
△ Less
Submitted 20 September, 2012;
originally announced September 2012.
-
Remote atomic clock synchronization via satellites and optical fibers
Authors:
D. Piester,
M. Rost,
M. Fujieda,
T. Feldmann,
A. Bauch
Abstract:
In the global network of institutions engaged with the realization of International Atomic Time (TAI), atomic clocks and time scales are compared by means of the Global Positioning System (GPS) and by employing telecommunication satellites for two-way satellite time and frequency transfer (TWSTFT). The frequencies of the state-of-the-art primary caesium fountain clocks can be compared at the level…
▽ More
In the global network of institutions engaged with the realization of International Atomic Time (TAI), atomic clocks and time scales are compared by means of the Global Positioning System (GPS) and by employing telecommunication satellites for two-way satellite time and frequency transfer (TWSTFT). The frequencies of the state-of-the-art primary caesium fountain clocks can be compared at the level of 10e-15 (relative, 1 day averaging) and time scales can be synchronized with an uncertainty of one nanosecond. Future improvements of worldwide clock comparisons will require also an improvement of the local signal distribution systems. For example, the future ACES (atomic clock ensemble in space) mission shall demonstrate remote time scale comparisons at the uncertainty level of 100 ps. To ensure that the ACES ground instrument will be synchronized to the local time scale at PTB without a significant uncertainty contribution, we have developed a means for calibrated clock comparisons through optical fibers. An uncertainty below 50 ps over a distance of 2 km has been demonstrated on the campus of PTB. This technology is thus in general a promising candidate for synchronization of enhanced time transfer equipment with the local realizations of UTC . Based on these experiments we estimate the uncertainty level for calibrated time transfer through optical fibers over longer distances. These findings are compared with the current status and developments of satellite based time transfer systems, with a focus on the calibration techniques for operational systems.
△ Less
Submitted 2 May, 2011;
originally announced May 2011.
-
Time Transfer Through Optical Fibers (TTTOF): Progress on Calibrated Clock Comparisons
Authors:
M. Rost,
M. Fujieda,
D. Piester
Abstract:
During the last years the transfer of frequency signals through optical fibers has shown ultra low instabilities in various configurations. The outstanding experimental results of such point-to-point connections is motivation to develop a means to extend the frequency transfer to accurate time transfer. We aim at the synchronization of clocks located at different places of the PTB campus with an o…
▽ More
During the last years the transfer of frequency signals through optical fibers has shown ultra low instabilities in various configurations. The outstanding experimental results of such point-to-point connections is motivation to develop a means to extend the frequency transfer to accurate time transfer. We aim at the synchronization of clocks located at different places of the PTB campus with an over-all uncertainty of less than 100 ps. Such an installation can be used as a part of the infrastructure connecting local time scales with the ground station setup during forthcoming ACES experiments and the local two-way satellite time and frequency transfer (TWSTFT) installations. This paper reports on the progress on time transfer through optical fibers (TTTOF) similar to the well known and long established TWSTFT scheme: A 10 MHz signal is transferred through an optical fiber connection to a remote site for realization of a time scale using a 10 MHz to 1PPS divider. For time transfer the 1PPS output is initially synchronized and then monitored by TWSTFT equipment connected by a second optical fiber to observe instabilities and uncertainties. Depending on further needs in future the transferred signal can be monitored only (for software correction) or controlled in real time by adding adequate phase shifters. We discuss procedures for a proper calibration of such TTTOF links and show results of experiments using fiber lengths up to two kilometers which prove that the proposed method is well suitable for the envisaged purpose.
△ Less
Submitted 21 December, 2010;
originally announced December 2010.
-
Time Transfer Through Optical Fibers (TTTOF): First Results of Calibrated Clock Comparisons
Authors:
D. Piester,
M. Fujieda,
M. Rost,
A. Bauch
Abstract:
We have developed a means for accurate time transfer using optical fibers and aim at the synchronization of clocks located at different places on an institute campus with an overall uncertainty of 100 ps or better. Such an installation shall be used as a part of the infrastructure connecting the ground station setups during forthcoming T2L2 and ACES experiments and the local installations at the…
▽ More
We have developed a means for accurate time transfer using optical fibers and aim at the synchronization of clocks located at different places on an institute campus with an overall uncertainty of 100 ps or better. Such an installation shall be used as a part of the infrastructure connecting the ground station setups during forthcoming T2L2 and ACES experiments and the local installations at the PTB time laboratory. Our target transmission length is less than 1 km. To transfer time, a code-domain-multiple-access (CDMA) signal is used for modulation of a laser. Optical signals are exchanged in the two-way mode to cancel long-term fiber length variation. This is similar to the well known two-way satellite time and frequency transfer (TWSTFT) scheme. We discuss procedures for a proper calibration of such time transfer through optical fibers links and show first promising results of an experiment using a test loop on the PTB campus with a length of 2 km.
△ Less
Submitted 29 January, 2010;
originally announced January 2010.