-
Exploring the parameter space of MagLIF implosions using similarity scaling. III. Rise-time scaling
Authors:
D. E. Ruiz,
P. F. Schmit,
M. R. Weis,
K. J. Peterson,
M. K. Matzen
Abstract:
Magnetized Liner Inertial Fusion (MagLIF) is a z-pinch magneto-inertial-fusion (MIF) concept studied on the Z Machine at Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach peak current. It is known that, when driving a z-pinch load with a longer current-ris…
▽ More
Magnetized Liner Inertial Fusion (MagLIF) is a z-pinch magneto-inertial-fusion (MIF) concept studied on the Z Machine at Sandia National Laboratories. Two important metrics characterizing current delivery to a z-pinch load are the peak current and the current-rise time, which is roughly the time interval to reach peak current. It is known that, when driving a z-pinch load with a longer current-rise time, the performance of the z-pinch decreases. However, a theory to understand and quantify this effect is still lacking. In this paper, we utilize a framework based on similarity scaling to analytically investigate the variations in performance of MagLIF loads when varying the current-rise time, or equivalently, the implosion timescale. To maintain similarity between the implosions, we provide the scaling prescriptions of the experimental input parameters defining a MagLIF load and derive the scaling laws for the stagnation conditions and for various performance metrics. We compare predictions of the theory to 2D numerical simulations using the radiation, magneto-hydrodynamic code HYDRA. For several metrics, we find acceptable agreement between the theory and simulations. Our results show that the voltage near the MagLIF load follows a weak scaling law $\smash{\varphi_{\rm load} \propto t_\varphi^{-0.12}}$ with respect to the characteristic timescale $t_\varphi$ of the voltage source, instead of the ideal $\smash{\varphi_{\rm load} \propto t_\varphi^{-1}}$ scaling. This occurs because the imploding height of the MagLIF load must increase to preserve end losses. As a consequence of the longer imploding liners, the required total laser preheat energy and delivered electric energy increase. Overall, this study may help understand the trade-offs of the MagLIF design space when considering future pulsed-power generators with shorter and longer current-rise times.
△ Less
Submitted 5 January, 2023; v1 submitted 29 September, 2022;
originally announced September 2022.
-
Clinical Concept Extraction: a Methodology Review
Authors:
Sunyang Fu,
David Chen,
Huan He,
Sijia Liu,
Sungrim Moon,
Kevin J Peterson,
Feichen Shen,
Liwei Wang,
Yanshan Wang,
Andrew Wen,
Yiqing Zhao,
Sunghwan Sohn,
Hongfang Liu
Abstract:
Background Concept extraction, a subdomain of natural language processing (NLP) with a focus on extracting concepts of interest, has been adopted to computationally extract clinical information from text for a wide range of applications ranging from clinical decision support to care quality improvement.
Objectives In this literature review, we provide a methodology review of clinical concept ext…
▽ More
Background Concept extraction, a subdomain of natural language processing (NLP) with a focus on extracting concepts of interest, has been adopted to computationally extract clinical information from text for a wide range of applications ranging from clinical decision support to care quality improvement.
Objectives In this literature review, we provide a methodology review of clinical concept extraction, aiming to catalog development processes, available methods and tools, and specific considerations when developing clinical concept extraction applications.
Methods Based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, a literature search was conducted for retrieving EHR-based information extraction articles written in English and published from January 2009 through June 2019 from Ovid MEDLINE In-Process & Other Non-Indexed Citations, Ovid MEDLINE, Ovid EMBASE, Scopus, Web of Science, and the ACM Digital Library.
Results A total of 6,686 publications were retrieved. After title and abstract screening, 228 publications were selected. The methods used for developing clinical concept extraction applications were discussed in this review.
△ Less
Submitted 10 August, 2020; v1 submitted 24 October, 2019;
originally announced October 2019.
-
Exploring magnetized liner inertial fusion with a semi-analytic model
Authors:
R. D. McBride,
S. A. Slutz,
R. A. Vesey,
M. R. Gomez,
A. B. Sefkow,
S. B. Hansen,
P. F. Knapp,
P. F. Schmit,
M. Geissel,
A. J. Harvey-Thompson,
C. A. Jennings,
E. C. Harding,
T. J. Awe,
D. C. Rovang,
K. D. Hahn,
M. R. Martin,
K. R. Cochrane,
K. J. Peterson,
G. A. Rochau,
J. L. Porter,
W. A. Stygar,
E. M. Campbell,
C. W. Nakhleh,
M. C. Herrmann,
M. E. Cuneo
, et al. (1 additional authors not shown)
Abstract:
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the depende…
▽ More
In this paper, we explore magnetized liner inertial fusion (MagLIF) [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] using a semi-analytic model [R. D. McBride and S. A. Slutz, Phys. Plasmas 22, 052708 (2015)]. Specifically, we present simulation results from this model that: (a) illustrate the parameter space, energetics, and overall system efficiencies of MagLIF; (b) demonstrate the dependence of radiative loss rates on the radial fraction of the fuel that is preheated; (c) explore some of the recent experimental results of the MagLIF program at Sandia National Laboratories [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)]; (d) highlight the experimental challenges presently facing the MagLIF program; and (e) demonstrate how increases to the preheat energy, fuel density, axial magnetic field, and drive current could affect future MagLIF performance.
△ Less
Submitted 13 January, 2016; v1 submitted 25 November, 2015;
originally announced November 2015.
-
Model-independent determination of the strong-phase difference between D^0 and D^0-bar-> K^0_S,L h^+ h^- (h=pi,K) and its impact on the measurement of the CKM angle gamma/phi_3
Authors:
J. Libby,
M. Kornicer,
R. E. Mitchell,
M. R. Shepherd,
C. M. Tarbert,
D. Besson,
T. K. Pedlar,
J. Xavier,
D. Cronin-Hennessy,
J. Hietala,
P. Zweber,
S. Dobbs,
Z. Metreveli,
K. K. Seth,
A. Tomaradze,
T. Xiao,
S. Brisbane,
S. Malde,
L. Martin,
A. Powell,
P. Spradlin,
G. Wilkinson,
H. Mendez,
J. Y. Ge,
D. H. Miller
, et al. (59 additional authors not shown)
Abstract:
We report the first determination of the relative strong-phase difference between D^0 -> K^0_S,L K^+ K^- and D^0-bar -> K^0_S,L K^+ K^-. In addition, we present updated measurements of the relative strong-phase difference between D^0 -> K^0_S,L pi^+ pi^- and D^0-bar -> K^0_S,L pi^+ pi^-. Both measurements exploit the quantum coherence between a pair of D^0 and D^0-bar mesons produced from psi(3770…
▽ More
We report the first determination of the relative strong-phase difference between D^0 -> K^0_S,L K^+ K^- and D^0-bar -> K^0_S,L K^+ K^-. In addition, we present updated measurements of the relative strong-phase difference between D^0 -> K^0_S,L pi^+ pi^- and D^0-bar -> K^0_S,L pi^+ pi^-. Both measurements exploit the quantum coherence between a pair of D^0 and D^0-bar mesons produced from psi(3770) decays. The strong-phase differences measured are important for determining the Cabibbo-Kobayashi-Maskawa angle gamma/phi_3 in B^- -> K^- D^0-tilde decays, where D^0-tilde is a D^0 or D^0-bar meson decaying to K^0_S h^+ h^- (h=pi,K), in a manner independent of the model assumed to describe the D^0 -> K^0_S h^+ h^- decay. Using our results, the uncertainty in gamma/phi_3 due to the error on the strong-phase difference is expected to be between 1.7 and 3.9 degrees for an analysis using B^- K^- D^0-tilde D^0-tilde -> K^0_S pi^+ pi^- decays, and between 3.2 and 3.9 degrees for an analysis based on B^- -> K^- D^0-tilde, D^0-tilde -> K^0_S K^+ K^- decays. A measurement is also presented of the CP-odd fraction, F_-, of the decay D^0 -> K^0_S K^+ K^- in the region of the phi -> K^+ K^- resonance. We find that in a region within 0.01 GeV^2/c^4 of the nominal phi mass squared F_- > 0.91 at the 90% confidence level.
△ Less
Submitted 2 February, 2016; v1 submitted 13 October, 2010;
originally announced October 2010.