-
Time-resolved diamond magnetic microscopy of superparamagnetic iron-oxide nanoparticles
Authors:
B. A. Richards,
N. Ristoff,
J. Smits,
A. Jeronimo Perez,
I. Fescenko,
M. D. Aiello,
F. Hubert,
Y. Silani,
N. Mosavian,
M. Saleh Ziabari,
A. Berzins,
J. T. Damron,
P. Kehayias,
D. Egbebunmi,
J. E. Shield,
D. L. Huber,
A. M. Mounce,
M. P. Lilly,
T. Karaulanov,
A. Jarmola,
A. Laraoui,
V. M. Acosta
Abstract:
Superparamagnetic iron-oxide nanoparticles (SPIONs) are promising probes for biomedical imaging, but the heterogeneity of their magnetic properties is difficult to characterize with existing methods. Here, we perform widefield imaging of the stray magnetic fields produced by hundreds of isolated ~30-nm SPIONs using a magnetic microscope based on nitrogen-vacancy centers in diamond. By analyzing th…
▽ More
Superparamagnetic iron-oxide nanoparticles (SPIONs) are promising probes for biomedical imaging, but the heterogeneity of their magnetic properties is difficult to characterize with existing methods. Here, we perform widefield imaging of the stray magnetic fields produced by hundreds of isolated ~30-nm SPIONs using a magnetic microscope based on nitrogen-vacancy centers in diamond. By analyzing the SPION magnetic field patterns as a function of applied magnetic field, we observe substantial field-dependent transverse magnetization components that are typically obscured with ensemble characterization methods. We find negligible hysteresis in each of the three magnetization components for nearly all SPIONs in our sample. Most SPIONs exhibit a sharp Langevin saturation curve, enumerated by a characteristic polarizing applied field, B_c. The B_c distribution is highly asymmetric, with a standard deviation (1.4 mT) that is larger than the median (0.6 mT). Using time-resolved magnetic microscopy, we directly record SPION Néel relaxation, after switching off a 31 mT applied field, with a temporal resolution of ~60 ms that is limited by the ring-down time of the electromagnet coils. For small bias fields B_{hold}=1.5-3.5 mT, we observe a broad range of SPION Néel relaxation times--from milliseconds to seconds--that are consistent with an exponential dependence on B_{hold}. Our time-resolved diamond magnetic microscopy study reveals rich SPION sample heterogeneity and may be extended to other fundamental studies of nanomagnetism.
△ Less
Submitted 3 February, 2025; v1 submitted 20 November, 2024;
originally announced November 2024.
-
Residence Time Distribution Analysis of Aerosol Transport and Associated Healthcare Worker Exposure in a Mock Hospital Isolation Room via Computational Fluid Dynamics
Authors:
Anthony J. Perez,
Juan Penaloza-Gutierrez,
Tauhidur Rahman,
Andrés E. Tejada-Martínez
Abstract:
The transport of aerosol discharge in the form of a passive scalar or tracer discharged from a single cough of a patient in a ventilated mock hospital isolation room is investigated via computational fluid dynamics (CFD). Healthcare worker (HCW) exposure to the aerosol is assessed through residence time analysis of the aerosol transported through the imperfect mixing conditions in the room. Flow f…
▽ More
The transport of aerosol discharge in the form of a passive scalar or tracer discharged from a single cough of a patient in a ventilated mock hospital isolation room is investigated via computational fluid dynamics (CFD). Healthcare worker (HCW) exposure to the aerosol is assessed through residence time analysis of the aerosol transported through the imperfect mixing conditions in the room. Flow features responsible for imperfect mixing, including short-circuiting or channeling between the patient and exhaust air vent (which leads to rapid expulsion of aerosols from the room), dead zones or re-circulation flow regions in the room, and the turbulent diffusion or spreading of aerosol across the room, are shown to play important factors determining the HCW exposure to the aerosol. The importance of each of these factors varies depending on the ventilation rate (ACH) and the placement of the exhaust air vent relative to the patient. For example, reducing ACH from 12 to 6 diminishes the importance of these flow features and the aerosol transport may be approximately modeled through the classical perfectly mixed assumption. At ACH = 12, especially when the ceiling exhaust is placed above the patient and the HCW, short-circuiting is the dominant feature in determining HCW exposure. But when the ceiling exhaust is placed away from the patient and HCW, the short-circuiting is weakened and the influence of dead zones, which trap aerosol, and turbulent diffusion, which allow the aerosol to escape, becomes more important. It is shown that the importance of these flow features and the resulting impact on HCW exposure can be quantified in terms of residence time distribution (RTD) metrics such as mean residence time and cumulative RTD. The results suggest that residence time analysis is a useful technique to be employed when designing a hospital isolation room and assessing HCW exposure to aerosols.
△ Less
Submitted 5 March, 2023;
originally announced April 2023.
-
Absorptive corrections for vector mesons. Matching to complex mass scheme and longitudinal corrections
Authors:
L. A. Jiménez Pérez,
G. Toledo Sánchez
Abstract:
Unstable spin-1 particles are properly described by including absorptive corrections to the electromagnetic vertex and propagator, without breaking the electromagnetic gauge invariance. We show that the modified propagator can be set into a complex mass form, provided the mass and the width parameters, which are properly defined at the pole position, are replaced by energy dependent functions fulf…
▽ More
Unstable spin-1 particles are properly described by including absorptive corrections to the electromagnetic vertex and propagator, without breaking the electromagnetic gauge invariance. We show that the modified propagator can be set into a complex mass form, provided the mass and the width parameters, which are properly defined at the pole position, are replaced by energy dependent functions fulfilling the same requirements at the pole. We exemplify the case for the $K^*(892)$ vector meson, where the mass function deviates around 2 MeV from the $Kπ$ threshold to the pole position. The absorptive correction depends on the mass of the particles in the loop. For vector mesons, whose main decay is into two pseudoscalar mesons ($PP'$), the flavor symmetry breaking induces a correction to the longitudinal part of the propagator. Considering the $τ^- \to K_Sπ^-ν_τ$ decay, we illustrate these corrections by obtaining the modified vector and scalar form factors. The $K_Sπ^-$ spectrum is described considering the $K^*(892)$ and $K^{'*}(1410)$ vectors and one scalar particle. Nonetheless, for this case, the correction to the scalar form factor is found to be negligible.
△ Less
Submitted 28 March, 2017;
originally announced March 2017.
-
The discrete spectrum of the D=11 bosonic M5-brane
Authors:
I. Martin,
L. Navarro,
A. J. Perez,
A. Restuccia
Abstract:
We prove that the spectrum of the regularized M5-brane in D=11 target space is discrete with eigenvalues extending to infinity. The proof includes the same result for the spectra of regularized bosonic p-branes in general.
We prove that the spectrum of the regularized M5-brane in D=11 target space is discrete with eigenvalues extending to infinity. The proof includes the same result for the spectra of regularized bosonic p-branes in general.
△ Less
Submitted 22 August, 2007; v1 submitted 25 May, 2007;
originally announced May 2007.