CHIPS Event Reconstruction and Design Optimisation
Authors:
A. Blake,
S. Germani,
Y. B. Pan,
A. J. Perch,
M. M. Pfützner,
J. Thomas,
L. H. Whitehead
Abstract:
The CHIPS experiment will comprise a 10 kton water Cherenkov detector in an open mine pit in northern Minnesota, USA. The detector has been simulated using a full GEANT4 simulation and a series of event reconstruction algorithms have been developed to exploit the charge and time information from all of the PMTs. A comparison of simulated CCQE nu_mu and nu_e interactions using 10 inch and 3 inch PM…
▽ More
The CHIPS experiment will comprise a 10 kton water Cherenkov detector in an open mine pit in northern Minnesota, USA. The detector has been simulated using a full GEANT4 simulation and a series of event reconstruction algorithms have been developed to exploit the charge and time information from all of the PMTs. A comparison of simulated CCQE nu_mu and nu_e interactions using 10 inch and 3 inch PMTs is presented, alongside a comparison of 10% and 6% photocathode coverage for 3 inch PMTs. The studies demonstrate that the required selection efficiency and purity of charged-current nu_e interactions can be achieved using a photocathode coverage of 6% with 3 inch PMTs. Finally, a dedicated pi-zero fitter is shown to successfully reconstruct a clean sample of pi-zero mesons despite the low 6% photocathode coverage with 3 inch PMTs.
△ Less
Submitted 14 December, 2016;
originally announced December 2016.
Measuring the Attenuation Length of Water in the CHIPS-M Water Cherenkov Detector
Authors:
F. Amat,
P. Bizouard,
J. Bryant,
T. J. Carroll,
S. De Rijck,
S. Germani,
T. Joyce,
B. Kreisten,
M. Marshak,
J. Meier,
J. Nelson,
A. J. Perch,
M. M. Pfuzner,
R. Salazar,
J. Thomas,
J. Trokan-Tenorio,
P. Vahle,
R. Wade,
C. Wendt,
L. H. Whitehead,
M. Whitney
Abstract:
The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2\unit{m} vertical column filled with this water, was used to study the transmissi…
▽ More
The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2\unit{m} vertical column filled with this water, was used to study the transmission of 405nm laser light. Results consistent with attenuation lengths of up to 100m were observed for this wavelength with filtration and UV sterilization alone.
△ Less
Submitted 19 November, 2016; v1 submitted 21 October, 2016;
originally announced October 2016.