-
Deformable registration and generative modelling of aortic anatomies by auto-decoders and neural ODEs
Authors:
Riccardo Tenderini,
Luca Pegolotti,
Fanwei Kong,
Stefano Pagani,
Francesco Regazzoni,
Alison L. Marsden,
Simone Deparis
Abstract:
This work introduces AD-SVFD, a deep learning model for the deformable registration of vascular shapes to a pre-defined reference and for the generation of synthetic anatomies. AD-SVFD operates by representing each geometry as a weighted point cloud and models ambient space deformations as solutions at unit time of ODEs, whose time-independent right-hand sides are expressed through artificial neur…
▽ More
This work introduces AD-SVFD, a deep learning model for the deformable registration of vascular shapes to a pre-defined reference and for the generation of synthetic anatomies. AD-SVFD operates by representing each geometry as a weighted point cloud and models ambient space deformations as solutions at unit time of ODEs, whose time-independent right-hand sides are expressed through artificial neural networks. The model parameters are optimized by minimizing the Chamfer Distance between the deformed and reference point clouds, while backward integration of the ODE defines the inverse transformation. A distinctive feature of AD-SVFD is its auto-decoder structure, that enables generalization across shape cohorts and favors efficient weight sharing. In particular, each anatomy is associated with a low-dimensional code that acts as a self-conditioning field and that is jointly optimized with the network parameters during training. At inference, only the latent codes are fine-tuned, substantially reducing computational overheads. Furthermore, the use of implicit shape representations enables generative applications: new anatomies can be synthesized by suitably sampling from the latent space and applying the corresponding inverse transformations to the reference geometry. Numerical experiments, conducted on healthy aortic anatomies, showcase the high-quality results of AD-SVFD, which yields extremely accurate approximations at competitive computational costs.
△ Less
Submitted 1 June, 2025;
originally announced June 2025.
-
Leveraging Cardiovascular Simulations for In-Vivo Prediction of Cardiac Biomarkers
Authors:
Laura Manduchi,
Antoine Wehenkel,
Jens Behrmann,
Luca Pegolotti,
Andy C. Miller,
Ozan Sener,
Marco Cuturi,
Guillermo Sapiro,
Jörn-Henrik Jacobsen
Abstract:
Whole-body hemodynamics simulators, which model blood flow and pressure waveforms as functions of physiological parameters, are now essential tools for studying cardiovascular systems. However, solving the corresponding inverse problem of mapping observations (e.g., arterial pressure waveforms at specific locations in the arterial network) back to plausible physiological parameters remains challen…
▽ More
Whole-body hemodynamics simulators, which model blood flow and pressure waveforms as functions of physiological parameters, are now essential tools for studying cardiovascular systems. However, solving the corresponding inverse problem of mapping observations (e.g., arterial pressure waveforms at specific locations in the arterial network) back to plausible physiological parameters remains challenging. Leveraging recent advances in simulation-based inference, we cast this problem as statistical inference by training an amortized neural posterior estimator on a newly built large dataset of cardiac simulations that we publicly release. To better align simulated data with real-world measurements, we incorporate stochastic elements modeling exogenous effects. The proposed framework can further integrate in-vivo data sources to refine its predictive capabilities on real-world data. In silico, we demonstrate that the proposed framework enables finely quantifying uncertainty associated with individual measurements, allowing trustworthy prediction of four biomarkers of clinical interest--namely Heart Rate, Cardiac Output, Systemic Vascular Resistance, and Left Ventricular Ejection Time--from arterial pressure waveforms and photoplethysmograms. Furthermore, we validate the framework in vivo, where our method accurately captures temporal trends in CO and SVR monitoring on the VitalDB dataset. Finally, the predictive error made by the model monotonically increases with the predicted uncertainty, thereby directly supporting the automatic rejection of unusable measurements.
△ Less
Submitted 23 December, 2024;
originally announced December 2024.
-
Bayesian Windkessel calibration using optimized 0D surrogate models
Authors:
Jakob Richter,
Jonas Nitzler,
Luca Pegolotti,
Karthik Menon,
Jonas Biehler,
Wolfgang A. Wall,
Daniele E. Schiavazzi,
Alison L. Marsden,
Martin R. Pfaller
Abstract:
Boundary condition (BC) calibration to assimilate clinical measurements is an essential step in any subject-specific simulation of cardiovascular fluid dynamics. Bayesian calibration approaches have successfully quantified the uncertainties inherent in identified parameters. Yet, routinely estimating the posterior distribution for all BC parameters in 3D simulations has been unattainable due to th…
▽ More
Boundary condition (BC) calibration to assimilate clinical measurements is an essential step in any subject-specific simulation of cardiovascular fluid dynamics. Bayesian calibration approaches have successfully quantified the uncertainties inherent in identified parameters. Yet, routinely estimating the posterior distribution for all BC parameters in 3D simulations has been unattainable due to the infeasible computational demand. We propose an efficient method to identify Windkessel parameter posteriors using results from a single high-fidelity three-dimensional (3D) model evaluation. We only evaluate the 3D model once for an initial choice of BCs and use the result to create a highly accurate zero-dimensional (0D) surrogate. We then perform Sequential Monte Carlo (SMC) using the optimized 0D model to derive the high-dimensional Windkessel BC posterior distribution. We validate this approach in a publicly available dataset of N=72 subject-specific vascular models. We found that optimizing 0D models to match 3D data a priori lowered their median approximation error by nearly one order of magnitude. In a subset of models, we confirm that the optimized 0D models still generalize to a wide range of BCs. Finally, we present the high-dimensional Windkessel parameter posterior for different measured signal-to-noise ratios in a vascular model using SMC. We further validate that the 0D-derived posterior is a good approximation of the 3D posterior. The minimal computational demand of our method using a single 3D simulation, combined with the open-source nature of all software and data used in this work, will increase access and efficiency of Bayesian Windkessel calibration in cardiovascular fluid dynamics simulations.
△ Less
Submitted 29 July, 2024; v1 submitted 22 April, 2024;
originally announced April 2024.
-
Hybrid Physics-Based and Data-Driven Modeling of Vascular Bifurcation Pressure Differences
Authors:
Natalia L. Rubio,
Luca Pegolotti,
Martin R. Pfaller,
Eric F. Darve,
Alison L. Marsden
Abstract:
Reduced-order models (ROMs) allow for the simulation of blood flow in patient-specific vasculatures without the high computational cost and wait time associated with traditional computational fluid dynamics (CFD) models. Unfortunately, due to the simplifications made in their formulations, ROMs can suffer from significantly reduced accuracy. One common simplifying assumption is the continuity of s…
▽ More
Reduced-order models (ROMs) allow for the simulation of blood flow in patient-specific vasculatures without the high computational cost and wait time associated with traditional computational fluid dynamics (CFD) models. Unfortunately, due to the simplifications made in their formulations, ROMs can suffer from significantly reduced accuracy. One common simplifying assumption is the continuity of static or total pressure over vascular junctions. In many cases, this assumption has been shown to introduce significant error. We propose a model to account for this pressure difference, with the ultimate goal of increasing the accuracy of cardiovascular ROMs. Our model successfully uses a structure common in existing ROMs in conjunction with machine-learning techniques to predict the pressure difference over a vascular bifurcation. We analyze the performance of our model on steady and transient flows, testing it on three bifurcation cohorts representing three different bifurcation geometric types. We also compare the efficacy of different machine-learning techniques and two different model modalities.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
Simulation-based Inference for Cardiovascular Models
Authors:
Antoine Wehenkel,
Laura Manduchi,
Jens Behrmann,
Luca Pegolotti,
Andrew C. Miller,
Guillermo Sapiro,
Ozan Sener,
Marco Cuturi,
Jörn-Henrik Jacobsen
Abstract:
Over the past decades, hemodynamics simulators have steadily evolved and have become tools of choice for studying cardiovascular systems in-silico. While such tools are routinely used to simulate whole-body hemodynamics from physiological parameters, solving the corresponding inverse problem of mapping waveforms back to plausible physiological parameters remains both promising and challenging. Mot…
▽ More
Over the past decades, hemodynamics simulators have steadily evolved and have become tools of choice for studying cardiovascular systems in-silico. While such tools are routinely used to simulate whole-body hemodynamics from physiological parameters, solving the corresponding inverse problem of mapping waveforms back to plausible physiological parameters remains both promising and challenging. Motivated by advances in simulation-based inference (SBI), we cast this inverse problem as statistical inference. In contrast to alternative approaches, SBI provides \textit{posterior distributions} for the parameters of interest, providing a \textit{multi-dimensional} representation of uncertainty for \textit{individual} measurements. We showcase this ability by performing an in-silico uncertainty analysis of five biomarkers of clinical interest comparing several measurement modalities. Beyond the corroboration of known facts, such as the feasibility of estimating heart rate, our study highlights the potential of estimating new biomarkers from standard-of-care measurements. SBI reveals practically relevant findings that cannot be captured by standard sensitivity analyses, such as the existence of sub-populations for which parameter estimation exhibits distinct uncertainty regimes. Finally, we study the gap between in-vivo and in-silico with the MIMIC-III waveform database and critically discuss how cardiovascular simulations can inform real-world data analysis.
△ Less
Submitted 30 December, 2024; v1 submitted 25 July, 2023;
originally announced July 2023.
-
Learning Reduced-Order Models for Cardiovascular Simulations with Graph Neural Networks
Authors:
Luca Pegolotti,
Martin R. Pfaller,
Natalia L. Rubio,
Ke Ding,
Rita Brugarolas Brufau,
Eric Darve,
Alison L. Marsden
Abstract:
Reduced-order models based on physics are a popular choice in cardiovascular modeling due to their efficiency, but they may experience reduced accuracy when working with anatomies that contain numerous junctions or pathological conditions. We develop one-dimensional reduced-order models that simulate blood flow dynamics using a graph neural network trained on three-dimensional hemodynamic simulati…
▽ More
Reduced-order models based on physics are a popular choice in cardiovascular modeling due to their efficiency, but they may experience reduced accuracy when working with anatomies that contain numerous junctions or pathological conditions. We develop one-dimensional reduced-order models that simulate blood flow dynamics using a graph neural network trained on three-dimensional hemodynamic simulation data. Given the initial condition of the system, the network iteratively predicts the pressure and flow rate at the vessel centerline nodes. Our numerical results demonstrate the accuracy and generalizability of our method in physiological geometries comprising a variety of anatomies and boundary conditions. Our findings demonstrate that our approach can achieve errors below 2% and 3% for pressure and flow rate, respectively, provided there is adequate training data. As a result, our method exhibits superior performance compared to physics-based one-dimensional models, while maintaining high efficiency at inference time.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.
-
Automated generation of 0D and 1D reduced-order models of patient-specific blood flow
Authors:
Martin R. Pfaller,
Jonathan Pham,
Aekaansh Verma,
Luca Pegolotti,
Nathan M. Wilson,
David W. Parker,
Weiguang Yang,
Alison L. Marsden
Abstract:
Three-dimensional (3D) cardiovascular fluid dynamics simulations typically require hours to days of computing time on a high-performance computing cluster. One-dimensional (1D) and lumped-parameter zero-dimensional (0D) models show great promise for accurately predicting blood bulk flow and pressure waveforms with only a fraction of the cost. They can also accelerate uncertainty quantification, op…
▽ More
Three-dimensional (3D) cardiovascular fluid dynamics simulations typically require hours to days of computing time on a high-performance computing cluster. One-dimensional (1D) and lumped-parameter zero-dimensional (0D) models show great promise for accurately predicting blood bulk flow and pressure waveforms with only a fraction of the cost. They can also accelerate uncertainty quantification, optimization, and design parameterization studies. Despite several prior studies generating 1D and 0D models and comparing them to 3D solutions, these were typically limited to either 1D or 0D and a singular category of vascular anatomies. This work proposes a fully automated and openly available framework to generate and simulate 1D and 0D models from 3D patient-specific geometries, automatically detecting vessel junctions and stenosis segments. Our only input is the 3D geometry; we do not use any prior knowledge from 3D simulations. All computational tools presented in this work are implemented in the open-source software platform SimVascular. We demonstrate the reduced-order approximation quality against rigid-wall 3D solutions in a comprehensive comparison with N=72 publicly available models from various anatomies, vessel types, and disease conditions. Relative average approximation errors of flows and pressures typically ranged from 1% to 10% for both 1D and 0D models, measured at the outlets of terminal vessel branches. In general, 0D model errors were only slightly higher than 1D model errors despite requiring only a third of the 1D runtime. Automatically generated ROMs can significantly speed up model development and shift the computational load from high-performance machines to personal computers.
△ Less
Submitted 14 June, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Model order reduction of flow based on a modular geometrical approximation of blood vessels
Authors:
Luca Pegolotti,
Martin Pfaller,
Alison Marsden,
Simone Deparis
Abstract:
We are interested in a reduced order method for the efficient simulation of blood flow in arteries. The blood dynamics is modeled by means of the incompressible Navier-Stokes equations. Our algorithm is based on an approximated domain-decomposition of the target geometry into a number of subdomains obtained from the parametrized deformation of geometrical building blocks (e.g. straight tubes and m…
▽ More
We are interested in a reduced order method for the efficient simulation of blood flow in arteries. The blood dynamics is modeled by means of the incompressible Navier-Stokes equations. Our algorithm is based on an approximated domain-decomposition of the target geometry into a number of subdomains obtained from the parametrized deformation of geometrical building blocks (e.g. straight tubes and model bifurcations). On each of these building blocks, we build a set of spectral functions by proper orthogonal decomposition of a large number of snapshots of finite element solutions (offline phase). The global solution of the Navier-Stokes equations on a target geometry is then found by coupling linear combinations of these local basis functions by means of spectral Lagrange multipliers (online phase). Being that the number of reduced degrees of freedom is considerably smaller than their finite element counterpart, this approach allows us to significantly decrease the size of the linear system to be solved in each iteration of the Newton-Raphson algorithm. We achieve large speedups with respect to the full order simulation (in our numerical experiments, the gain is at least of one order of magnitude and grows inversely with respect to the reduced basis size), whilst still retaining satisfactory accuracy for most cardiovascular simulations.
△ Less
Submitted 1 October, 2020;
originally announced October 2020.
-
Data driven approximation of parametrized PDEs by Reduced Basis and Neural Networks
Authors:
Niccolò Dal Santo,
Simone Deparis,
Luca Pegolotti
Abstract:
We are interested in the approximation of partial differential equations with a data-driven approach based on the reduced basis method and machine learning. We suppose that the phenomenon of interest can be modeled by a parametrized partial differential equation, but that the value of the physical parameters is unknown or difficult to be directly measured. Our method allows to estimate fields of i…
▽ More
We are interested in the approximation of partial differential equations with a data-driven approach based on the reduced basis method and machine learning. We suppose that the phenomenon of interest can be modeled by a parametrized partial differential equation, but that the value of the physical parameters is unknown or difficult to be directly measured. Our method allows to estimate fields of interest, for instance temperature of a sample of material or velocity of a fluid, given data at a handful of points in the domain. We propose to accomplish this task with a neural network embedding a reduced basis solver as exotic activation function in the last layer. The reduced basis solver accounts for the underlying physical phenomenonon and it is constructed from snapshots obtained from randomly selected values of the physical parameters during an expensive offline phase. The same full order solutions are then employed for the training of the neural network. As a matter of fact, the chosen architecture resembles an asymmetric autoencoder in which the decoder is the reduced basis solver and as such it does not contain trainable parameters. The resulting latent space of our autoencoder includes parameter-dependent quantities feeding the reduced basis solver, which -- depending on the considered partial differential equation -- are the values of the physical parameters themselves or the affine decomposition coefficients of the differential operators.
△ Less
Submitted 29 June, 2019; v1 submitted 2 April, 2019;
originally announced April 2019.
-
Coupling non-conforming discretizations of PDEs by spectral approximation of the Lagrange multiplier space
Authors:
Simone Deparis,
Luca Pegolotti
Abstract:
This work focuses on the development of a non-conforming domain decomposition method for the approximation of PDEs based on weakly imposed transmission conditions: the continuity of the global solution is enforced by a discrete number of Lagrange multipliers defined over the interfaces of adjacent subdomains. The method falls into the class of primal hybrid methods, which also include the well-kno…
▽ More
This work focuses on the development of a non-conforming domain decomposition method for the approximation of PDEs based on weakly imposed transmission conditions: the continuity of the global solution is enforced by a discrete number of Lagrange multipliers defined over the interfaces of adjacent subdomains. The method falls into the class of primal hybrid methods, which also include the well-known mortar method. Differently from the mortar method, we discretize the space of basis functions on the interface by spectral approximation independently of the discretization of the two adjacent domains; one of the possible choices is to approximate the interface variational space by Fourier basis functions. As we show in the numerical simulations, our approach is well-suited for the solution of problems with non-conforming meshes or with finite element basis functions with different polynomial degrees in each subdomain. Another application of the method that still needs to be investigated is the coupling of solutions obtained from otherwise incompatible methods, such as the finite element method, the spectral element method or isogeometric analysis.
△ Less
Submitted 21 February, 2018;
originally announced February 2018.