Seven-Probe Fiber Detector for Time-Resolved Source Tracking in HDR-Brachytherapy: Experimental Evaluation
Authors:
Mathieu Gonod,
Miguel Angel Suarez,
Samir Laskri,
Gwenael Rolin,
Karine Charriere,
Emmanuel Dordor,
Julien Crouzilles,
Thomas Lihoreau,
Lionel Pazart,
Jean-Francois Vinchant,
Leone Aubignac,
Thierry Grosjean
Abstract:
{\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques.
{\bf Methods:} The SSD comprises seven detection cells made of Gd$_2$O$_2$S:Tb, each measuring 0.28 $\pm$ 0.02 mm in diameter and 0.43 $\pm$ 0.02 mm in length…
▽ More
{\bf Purpose:} This study evaluates a compact biocompatible Seven-probe Scintillator Detector (7SD) for monitoring HDR-BT treatment sequences across a range of dwell times and source-probe spacings representative of most HDR-BT techniques.
{\bf Methods:} The SSD comprises seven detection cells made of Gd$_2$O$_2$S:Tb, each measuring 0.28 $\pm$ 0.02 mm in diameter and 0.43 $\pm$ 0.02 mm in length, coupled to the microstructured tips of silica optical fibers (110-micron diameter). The probes, spaced 15 mm apart along the fiber axis, are organized into a bundle with a total diameter of less than 0.45 mm. The SSD was tested using a MicroSelectron 9.1 Ci Ir-192 HDR afterloader connected to a BT stainless steel interstitial needle. Detection signals were acquired with an sCMOS camera equipped. Monitoring of dwell times and positions was performed by combining detection signals from all seven probes.
{\bf Results:} A total of 4,040 dwell positions were analyzed, covering source-probe spacings from 10 to 36 mm and a source travel range of 62 mm, with dwell times ranging from 0.1 to 19.5 s. The 7SD successfully identified 99.5\% of the dwell positions. In cylindrical coordinates, the measured dwell positions deviated from the planned values by 0.224 $\pm$ 0.155 mm (radial) and 0.077 $\pm$ 0.181 mm (axial, source travel axis). The average deviation from planned dwell times was 0.006 $\pm$ 0.061 s. 99.4\% of the dwell positions were measured within the 1 mm reliability threshold. The remaining 0.6\% of deviations consistently occurred at the initial dwell position of treatment sequences and appear to stem from a systematic source positioning error by the afterloader. Additionally, the detector accurately identified intentional needle mispositioning scenarios with sub-millimeter accuracy.
△ Less
Submitted 19 June, 2025;
originally announced June 2025.
Miniaturized fiber dosimeter of medical radiations on a narrow optical fiber
Authors:
Miguel Angel Suarez,
Tony Lim,
Louise Robillot,
Valentin Maillot,
Thomas Lihoreau,
Patrick Bontemps,
Lionel Pazart,
Thierry Grosjean
Abstract:
Fiber dosimeters have recently drawn much interest for measuring in vivo and in real time the dose of medical radiations. This paper presents the first miniaturized fiber dosimeter integrated at the end of a narrow 125-micron outer diameter optical fiber. Miniaturization is rendered possible by exploiting the concept of a leaky wave optical antenna for interfacing the scintillators and the fiber,…
▽ More
Fiber dosimeters have recently drawn much interest for measuring in vivo and in real time the dose of medical radiations. This paper presents the first miniaturized fiber dosimeter integrated at the end of a narrow 125-micron outer diameter optical fiber. Miniaturization is rendered possible by exploiting the concept of a leaky wave optical antenna for interfacing the scintillators and the fiber, and by taking advantage of the low propagation loss of narrow silica fibers and high detection yield of single-pixel photon counters. Upon irradiation at 6 MV, our fiber probe led to a linear detection response with a signal-to-noise ratio as high as 190 in air. Although implemented with inorganic scintillators and fiber, our fiber probe induces an intensity contrast in the impinging radiation lower than 0.9% over an area of 0.153 mm2. Our nano-optically driven approach opens the route for ultra-compact fiber dosimeters of negligible footprint in the radiotherapeutic processes, even with non-water equivalent fibers and scintillators. A large panel of therapies relying on ionizing radiations (photons or charged particles) may take benefit of this nano-optically-driven technology.
△ Less
Submitted 9 September, 2019;
originally announced September 2019.