-
Recent results on the low-pressure GEM-based TPC at an Accelerator Mass Spectrometer
Authors:
A. Bondar,
V. Parkhomchuk,
A. Petrozhitsky,
T. Shakirova,
A. Sokolov
Abstract:
The Accelerator Mass Spectrometry technique makes it possible to measure rare long-lived isotopes such as $^{10}$Be, $^{14}$C, $^{26}$Al, $^{36}$Cl, $^{41}$Ca and $^{129}$I. The content of these isotopes can be at the level of 10$^{-15}$ of the total element content. The Accelerator Mass Spectrometer developed by Budker Institute of Nuclear Physics (BINP AMS) successfully measures the concentratio…
▽ More
The Accelerator Mass Spectrometry technique makes it possible to measure rare long-lived isotopes such as $^{10}$Be, $^{14}$C, $^{26}$Al, $^{36}$Cl, $^{41}$Ca and $^{129}$I. The content of these isotopes can be at the level of 10$^{-15}$ of the total element content. The Accelerator Mass Spectrometer developed by Budker Institute of Nuclear Physics (BINP AMS) successfully measures the concentration of $^{14}$C relative $^{12}$C. However, there is a problem of separating the $^{10}$B isobaric background from $^{10}$Be. Beryllium-10 is used to date geological objects on a time scale from 1 thousand years to 10 million years.
To solve this problem we have proposed a new technique for ion identification based on measuring both ion track ranges and ion energies in a low-pressure Time-Projection Chamber (TPC) with Gas Electron Multiplier (GEM) readout. We have developed the TPC with a dedicated thin silicon nitride window for an efficient passage of ions. To begin with, the characteristic of the low-pressure TPC were studied in isobutane at a pressure of 50 torr using alpha particle sources.
In this work, we set up the low-pressure TPC on BINP AMS facility and successfully measured track ranges and energies of ions from samples containing $^{14}$C. At the next stage, we are going to carry out measurements with samples containing $^{10}$Be. However, using the obtained results and SRIM simulation we have already shown that the isobaric boron and beryllium ions can be separated by more than 5 sigma. This technique is proposed to be applied in AMS for dating geological objects, namely for geochronology of Cenozoic era.
△ Less
Submitted 7 November, 2024;
originally announced November 2024.
-
New technique of ion identification in Accelerator Mass Spectrometry using low-pressure TPC with GEM readout
Authors:
A. Bondar,
A. Buzulutskov,
V. Parkhomchuk,
A. Petrozhitsky,
T. Shakirova,
A. Sokolov
Abstract:
We have developed and successfully tested a low-pressure Time Projection Chamber (TPC) with Gas Electron Multiplier (GEM) readout for Accelerator Mass Spectrometry (AMS).
AMS facility in Novosibirsk has a problem of separating isobar ions of different chemical elements that have the same atomic mass. The typical example is radioactive isotopes 10Be and 10B that are used to date geological object…
▽ More
We have developed and successfully tested a low-pressure Time Projection Chamber (TPC) with Gas Electron Multiplier (GEM) readout for Accelerator Mass Spectrometry (AMS).
AMS facility in Novosibirsk has a problem of separating isobar ions of different chemical elements that have the same atomic mass. The typical example is radioactive isotopes 10Be and 10B that are used to date geological objects at a time scale of ten million years. To solve this problem, a new ion identification technique, namely that based on measuring both ion track ranges and ion energies in low-pressure TPCs with GEM readout, has been developed. This technique is proposed to be applied in AMS for dating geological objects, namely for geochronology of Cenozoic era.
In this work, we developed a new larger version of the TPC with a dedicated thin silicon nitride window for an efficient passage of ions. The TPC characteristics were studied in isobutane at low pressures using alpha particle sources. In addition, the use of GEM instead of THGEM has been shown to substantially improve the energy resolution at a nominal pressure (50 torr). Using these results and SRIM code simulations, it is shown that isobaric boron and beryllium ions can be effectively separated at AMS, providing efficient dating on a scale of ten million years. This technique will be applied in the AMS facility in Novosibirsk in the near future.
△ Less
Submitted 11 May, 2023;
originally announced May 2023.
-
Ion detector for Accelerator Mass Spectrometry based on low-pressure TPC with THGEM readout
Authors:
A. Bondar,
A. Buzulutskov,
E. Frolov,
V. Parkhomchuk,
A. Petrozhitskiy,
T. Shakirova,
A. Sokolov
Abstract:
A new technique for ion identification in Accelerator Mass Spectrometry (AMS) has been proposed by measuring the ion track ranges using a low-pressure TPC. As a proof of principle, a low-pressure TPC with charge readout using a THGEM multiplier was developed. The tracks of alpha particles from various radioactive sources were successfully recorded in the TPC. The track ranges were measured with a…
▽ More
A new technique for ion identification in Accelerator Mass Spectrometry (AMS) has been proposed by measuring the ion track ranges using a low-pressure TPC. As a proof of principle, a low-pressure TPC with charge readout using a THGEM multiplier was developed. The tracks of alpha particles from various radioactive sources were successfully recorded in the TPC. The track ranges were measured with a high accuracy, reaching the 2% resolution level. Using these results and the SRIM code simulation, it is shown that the isobaric boron and beryllium ions can be effectively separated at ten sigma level. It is expected that this technique will be applied in the AMS facility in Novosibirsk for dating geological objects, in particular for the geochronology of Cenozoic Era.
△ Less
Submitted 30 September, 2019;
originally announced September 2019.
-
Darwinian Genetic Drift
Authors:
Alexey A. Shadrin,
Dmitri V. Parkhomchuk
Abstract:
Genetic drift is stochastic fluctuations of alleles frequencies in a population due to sampling effects. We consider a model of drift in an equilibrium population, with high mutation rates: few functional mutations per generation. Such mutation rates are common in multicellular organisms including humans, however they are not explicitly considered in most population genetics models. Under these as…
▽ More
Genetic drift is stochastic fluctuations of alleles frequencies in a population due to sampling effects. We consider a model of drift in an equilibrium population, with high mutation rates: few functional mutations per generation. Such mutation rates are common in multicellular organisms including humans, however they are not explicitly considered in most population genetics models. Under these assumptions the drift shows properties distinct from the classical drift models, which ignore realistic mutation rates: i) All (non-lethal) variants of a site have a characteristic average frequencies, which are independent of population size, however the magnitude of fluctuations around these frequencies depends on population size. ii) There is no "mutational meltdown" due to "low efficiency of selection" for small population size. Population average fitness does not depend on population size. iii) Drift (and molecular clock) can be represented as wandering by compensatory mutations, postulate of neutral mutations is not necessary for explaining the high rate of mutation accumulation. Our results, which adjust the meaning of the neutral theory from the individual neutrality of the majority of mutations, to the collective neutrality of compensatory mutations, are applicable to investigations in phylogeny and coalescent and for GWAS design and analysis.
△ Less
Submitted 11 January, 2017;
originally announced January 2017.
-
Drake's Rule as a Consequence of Approaching Channel Capacity
Authors:
Alexey A. Shadrin,
Dmitri V. Parkhomchuk
Abstract:
How mutations accumulate in genomes is the central question of molecular evolution theories, however our understanding of this process is far from complete. Drake's rule is a notoriously universal property of genomes from microbes to mammals - the number of (functional) mutations per-genome per-generation is approximately constant within a phylum, despite orders of magnitude differences in genome…
▽ More
How mutations accumulate in genomes is the central question of molecular evolution theories, however our understanding of this process is far from complete. Drake's rule is a notoriously universal property of genomes from microbes to mammals - the number of (functional) mutations per-genome per-generation is approximately constant within a phylum, despite orders of magnitude differences in genome sizes and diverse populations properties. So far there is no concise explanation for this phenomenon. A formal model of storage of genetic information suggests that a genome of any species operates near its maximum informational storage capacity, and the mutation rate is near its upper limit, providing a simple explanation for the rule with minimal assumptions.
△ Less
Submitted 28 February, 2014; v1 submitted 18 June, 2013;
originally announced June 2013.
-
Hydrostatic Level Sensors as High Precision Ground Motion Instrumentation for Tevatron and Other Energy Frontier Accelerators
Authors:
J. Volk,
S. Hansen,
T. Johnson,
H. Jostlein,
T. Kiper,
V. Shiltsev,
A. Chupyra,
M. Kondaurov,
A. Medvedko,
V. Parkhomchuk,
S. Singatulin,
L. Stetler,
J. Van Beek,
D. Fratta,
J. Roberts,
H. Wang
Abstract:
Particle accelerators pushed the limits of our knowledge in search of the answers to most fundamental questions about micro-world and our Universe. In these pursuits, accelerators progressed to higher and higher energies and particle beam intensities as well as increasingly smaller and smaller beam sizes. As the result, modern existing and planned energy frontier accelerators demand very tight tol…
▽ More
Particle accelerators pushed the limits of our knowledge in search of the answers to most fundamental questions about micro-world and our Universe. In these pursuits, accelerators progressed to higher and higher energies and particle beam intensities as well as increasingly smaller and smaller beam sizes. As the result, modern existing and planned energy frontier accelerators demand very tight tolerances on alignment and stability of their elements: magnets, accelerating cavities, vacuum chambers, etc. In this article we describe the instruments developed for and used in such accelerators as Fermilab's Tevatron (FNAL, Batavia, IL USA) and for the studies toward an International Linear Collider (ILC). The instrumentation includes Hydrostatic Level Sensors (HLS) for very low frequency measurements. We present design features of the sensors, outline their technical parameters, describe test and calibration procedures and discuss different regimes of operation. Experimental results of the ground motion measurements with these detectors will be presented in subsequent paper.
△ Less
Submitted 8 May, 2012;
originally announced May 2012.
-
Test of detuning system for dielectronic recombination experiment at CSRm
Authors:
L. J. Meng,
X. Ma,
V. V. Parkhomchuk,
D. Yang,
V. B. Reva,
J. Li,
L. J. Mao,
X. M. Ma,
T. L. Yan,
J. W. Xia,
Y. J. Yuan,
H. S. Xu,
J. C. Yang,
G. Q. Xiao
Abstract:
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+…
▽ More
The storage ring equipped with an electron cooler is an ideal platform for dielectronic recombination (DR) experiments. In order to fulfil the requirement of DR measurements at the main Cooler Storage Ring, a detuning system for the precision control of the relative energy between the ion beam and the electron beam has been installed on the electron cooler device. The test run using 7.0 MeV/u C6+ beam was performed to examine the influence of this system on the performance of the stored ion beam. The Schottky spectra and the ion beam currents were recorded to monitor the beam status. The influence of pulse heights and widths of the detuning voltage on the ion beam was investigated. For the small pulse height, the experimental results from the Schottky spectrum were in good agreement with the theoretical results. The frequency shift in the Schottky spectrum is significantly reduced for the short pulse width. For the large pulse height, an oscillation phenomenon was observed. From the Schottky spectrum, we found the oscillation amplitude is dependent on the pulse width of detuning and the ion beam intensity. The detailed description of the phenomenon and the theoretical model based on the plasma oscillation was discussed in this paper.
△ Less
Submitted 14 February, 2012;
originally announced February 2012.
-
Present Performance of Electron Cooling at Cosy-Jülich
Authors:
H. J. Stein,
D. Prasuhn,
H. Stockhorst,
J. Dietrich,
K. Fan,
V. Kamerdjiev,
R. Maier,
I. N. Meshkov,
A. Sidorin,
V. V. Parkhomchuk
Abstract:
At COSY, electron cooling is used after stripping injection of H- or D- ions in order to prepare phase-space-dense ion beams before acceleration to a requested energy. The electron-cooled beam has been successfully applied for specific external experiments. The achievable beam intensity is limited by instabilities during the cooling process. Besides initial losses after injection, as long as the b…
▽ More
At COSY, electron cooling is used after stripping injection of H- or D- ions in order to prepare phase-space-dense ion beams before acceleration to a requested energy. The electron-cooled beam has been successfully applied for specific external experiments. The achievable beam intensity is limited by instabilities during the cooling process. Besides initial losses after injection, as long as the beam has still large emittances, the self-excitation of coherent betatron oscillations is the dominating beam loss mechanism. Perspectives for possible improvements are briefly addressed.
△ Less
Submitted 31 January, 2011;
originally announced January 2011.
-
Experimental Studies of Compensation of Beam-Beam Effects with Tevatron Electron Lenses
Authors:
V. Shiltsev,
Yu. Alexahin,
K. Bishofberger,
V. Kamerdzhiev,
V. Parkhomchuk,
V. Reva,
N. Solyak,
D. Wildman,
X. -L. Zhang,
F. Zimmermann
Abstract:
Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the results of various beam experiments with electron lenses, novel instruments developed for the beam-beam compensation at the Tevatron, which collides 980-GeV pro…
▽ More
Applying the space-charge forces of a low-energy electron beam can lead to a significant improvement of the beam-particle lifetime limit arising from the beam-beam interaction in a high-energy collider [1]. In this article we present the results of various beam experiments with electron lenses, novel instruments developed for the beam-beam compensation at the Tevatron, which collides 980-GeV proton and antiproton beams. We study the dependencies of the particle betatron tunes on the electron beam current, energy and position; we explore the effects of electron-beam imperfections and noises; and we quantify the improvements of the high-energy beam intensity and the collider luminosity lifetime obtained by the action of the Tevatron Electron Lenses.
△ Less
Submitted 4 February, 2008;
originally announced February 2008.
-
Information Theory of Genomes
Authors:
Dmitri V. Parkhomchuk
Abstract:
Relation of genome sizes to organisms complexity is still described rather equivocally. Neither the number of genes (G-value), nor the total amount of DNA (C-value) correlates consistently with phenotype complexity. Using information theory considerations we developed a model that allows a quantative estimate for the amount of functional information in a genomic sequence. This model easily answe…
▽ More
Relation of genome sizes to organisms complexity is still described rather equivocally. Neither the number of genes (G-value), nor the total amount of DNA (C-value) correlates consistently with phenotype complexity. Using information theory considerations we developed a model that allows a quantative estimate for the amount of functional information in a genomic sequence. This model easily answers the long-standing question of why GC content is increased in functional regions. The model allows consistent estimate of genome complexities, resolving the major discrepancies of G- and C-values. For related organisms with similarly complex phenotypes, this estimate provides biological insights into their niches complexities. This theoretical framework suggests that biological information can rapidly evolve on demand from environment, mainly in non-coding genomic sequence and explains the role of duplications in the evolution of biological information. Knowing the approximate amount of functionality in a genomic sequence is useful for many applications such as phylogenetics analyses, in-silico functional elements discovery or prioritising targets for genotyping and sequencing.
△ Less
Submitted 12 January, 2007; v1 submitted 19 December, 2006;
originally announced December 2006.
-
Conceptual Design for a Polarized Proton-Antiproton Collider Facility at Gsi
Authors:
F. Bradamante,
I. Koop,
A. Otboev,
V. Parkhomchuk,
V. Reva P. Shatunov,
Yu. Shatunov
Abstract:
Two possible options of polarized proton-antiproton collider at the future HESR storage ring are considered. It is shown that the modifications of the present HESR project which are needed to arrange for the polarized proton-antiproton collisions are relatively moderate. An achievable luminosity of 5x10^31 cm^-2 sec^-1 will provide a possibility to carry out experiments in the CM energy range 10…
▽ More
Two possible options of polarized proton-antiproton collider at the future HESR storage ring are considered. It is shown that the modifications of the present HESR project which are needed to arrange for the polarized proton-antiproton collisions are relatively moderate. An achievable luminosity of 5x10^31 cm^-2 sec^-1 will provide a possibility to carry out experiments in the CM energy range 10-30 GeV, a particularly interesting option for Drell-Yan physics.
△ Less
Submitted 13 December, 2005; v1 submitted 30 November, 2005;
originally announced November 2005.