Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km
Authors:
H. Hachisu,
M. Fujieda,
S. Nagano,
T. Gotoh,
A. Nogami,
T. Ido,
St. Falke,
N. Huntemann,
C. Grebing,
B. Lipphardt,
Ch. Lisdat,
D. Piester
Abstract:
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fra…
▽ More
We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.
△ Less
Submitted 12 July, 2014; v1 submitted 25 March, 2014;
originally announced March 2014.
Direct comparison of a Ca+ single ion clock against a Sr optical lattice clock
Authors:
Kensuke Matsubara,
Hidekazu Hachisu,
Ying Li,
Shigeo Nagano,
Clayton Locke,
Asahiko Nogami,
Masatoshi Kajita,
Kazuhiro Hayasaka,
Tetsuya Ido,
Mizuhiko Hosokawa
Abstract:
Optical frequency comparison of the 40Ca+ clock transition ν_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition ν_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio ν_{Ca} / ν_{Sr} = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν_{Ca} / ν_{Sr} to reach 1x10-15 in only 1000s and yielded a val…
▽ More
Optical frequency comparison of the 40Ca+ clock transition ν_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition ν_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio ν_{Ca} / ν_{Sr} = 0.957 631 202 358 049 9(2 3). The rapid nature of optical comparison allowed the statistical uncertainty of frequency ratio ν_{Ca} / ν_{Sr} to reach 1x10-15 in only 1000s and yielded a value consistent with that calculated from separate absolute frequency measurements of ν_{Ca} using the International Atomic Time (TAI) link. The total uncertainty of the frequency ratio using optical comparison (free from microwave link uncertainties) is smaller than that obtained using absolute frequency measurement, demonstrating the advantage of optical frequency evaluation. We report the absolute frequency of ^{40}Ca+ with a systematic uncertainty 14 times smaller than our previous measurement [1].
△ Less
Submitted 22 August, 2012;
originally announced August 2012.