-
Stable beam operation of approximately 1 mA beam under highly efficient energy recovery conditions at compact energy-recovery linac
Authors:
Hiroshi Sakai,
Dai Arakawa,
Takaaki Furuya,
Kaiichi Haga,
Masayuki Hagiwara,
Kentaro Harada,
Yosuke Honda,
Teruya Honma,
Eiji Kako,
Ryukou Kato,
Yuuji Kojima,
Taro Konomi,
Hiroshi Matsumura,
Taichi Miura,
Takako Miura,
Shinya Nagahashi,
Hirotaka Nakai,
Norio Nakamura,
Kota Nakanishi,
Kazuyuki Nigorikawa,
Takashi Nogami,
Takashi Obina,
Feng Qiu,
Hidenori Sagehashi,
Shogo Sakanaka
, et al. (15 additional authors not shown)
Abstract:
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the desi…
▽ More
A compact energy-recovery linac (cERL) has been un-der construction at KEK since 2009 to develop key technologies for the energy-recovery linac. The cERL began operating in 2013 to create a high-current beam with a low-emittance beam with stable continuous wave (CW) superconducting cavities. Owing to the development of critical components, such as the DC gun, superconducting cavities, and the design of ideal beam transport optics, we have successfully established approximately 1 mA stable CW operation with a small beam emittance and extremely small beam loss. This study presents the details of our key technologies and experimental results for achieving 100% energy recovery operation with extremely small beam loss during a stable, approximately 1 mA CW beam operation.
△ Less
Submitted 24 August, 2024;
originally announced August 2024.
-
Commissioning of a compact multibend achromat lattice: A new 3 GeV synchrotron radiation facility
Authors:
Shuhei Obara,
Kota Ueshima,
Takao Asaka,
Yuji Hosaka,
Koichi Kan,
Nobuyuki Nishimori,
Toshitaka Aoki,
Hiroyuki Asano,
Koichi Haga,
Yuto Iba,
Akira Ihara,
Katsumasa Ito,
Taiki Iwashita,
Masaya Kadowaki,
Rento Kanahama,
Hajime Kobayashi,
Hideki Kobayashi,
Hideo Nishihara,
Masaaki Nishikawa,
Haruhiko Oikawa,
Ryota Saida,
Keisuke Sakuraba,
Kento Sugimoto,
Masahiro Suzuki,
Kouki Takahashi
, et al. (57 additional authors not shown)
Abstract:
NanoTerasu, a new 3 GeV synchrotron light source in Japan, began user operation in April 2024. It provides high-brilliance soft to tender X-rays and covers a wide spectral range from ultraviolet to tender X-rays. Its compact storage ring with a circumference of 349 m is based on a four-bend achromat lattice to provide two straight sections in each cell for insertion devices with a natural horizont…
▽ More
NanoTerasu, a new 3 GeV synchrotron light source in Japan, began user operation in April 2024. It provides high-brilliance soft to tender X-rays and covers a wide spectral range from ultraviolet to tender X-rays. Its compact storage ring with a circumference of 349 m is based on a four-bend achromat lattice to provide two straight sections in each cell for insertion devices with a natural horizontal emittance of 1.14 nm rad, which is small enough for soft X-rays users. The NanoTerasu accelerator incorporates several innovative technologies, including a full-energy injector C-band linear accelerator with a length of 110 m, an in-vacuum off-axis injection system, a four-bend achromat with B-Q combined bending magnets, and a TM020 mode accelerating cavity with built-in higher-order-mode dampers in the storage ring. This paper presents the accelerator machine commissioning over a half-year period and our model-consistent ring optics correction. The first user operation with a stored beam current of 160 mA is also reported. We summarize the storage ring parameters obtained from the commissioning. This is helpful for estimating the effective optical properties of synchrotron radiation at NanoTerasu.
△ Less
Submitted 11 July, 2024;
originally announced July 2024.
-
Soft X-ray harmonic comb from relativistic electron spikes
Authors:
A. S. Pirozhkov,
M. Kando,
T. Zh. Esirkepov,
P. Gallegos,
H. Ahmed,
E. N. Ragozin,
A. Ya. Faenov,
T. A. Pikuz,
T. Kawachi,
A. Sagisaka,
J. K. Koga,
M. Coury,
J. Green,
P. Foster,
C. Brenner,
B. Dromey,
D. R. Symes,
M. Mori,
K. Kawase,
T. Kameshima,
Y. Fukuda,
L. Chen,
I. Daito,
K. Ogura,
Y. Hayashi
, et al. (15 additional authors not shown)
Abstract:
We demonstrate a new high-order harmonic generation mechanism reaching the `water window' spectral region in experiments with multi-terawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving uJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativis…
▽ More
We demonstrate a new high-order harmonic generation mechanism reaching the `water window' spectral region in experiments with multi-terawatt femtosecond lasers irradiating gas jets. A few hundred harmonic orders are resolved, giving uJ/sr pulses. Harmonics are collectively emitted by an oscillating electron spike formed at the joint of the boundaries of a cavity and bow wave created by a relativistically self-focusing laser in underdense plasma. The spike sharpness and stability are explained by catastrophe theory. The mechanism is corroborated by particle-in-cell simulations.
△ Less
Submitted 1 January, 2012;
originally announced January 2012.
-
X-ray harmonic comb from relativistic electron spikes
Authors:
Alexander S. Pirozhkov,
Masaki Kando,
Timur Zh. Esirkepov,
Eugene N. Ragozin,
Anatoly Ya. Faenov,
Tatiana A. Pikuz,
Tetsuya Kawachi,
Akito Sagisaka,
Michiaki Mori,
Keigo Kawase,
James K. Koga,
Takashi Kameshima,
Yuji Fukuda,
Liming Chen,
Izuru Daito,
Koichi Ogura,
Yukio Hayashi,
Hideyuki Kotaki,
Hiromitsu Kiriyama,
Hajime Okada,
Nobuyuki Nishimori,
Kiminori Kondo,
Toyoaki Kimura,
Toshiki Tajima,
Hiroyuki Daido
, et al. (2 additional authors not shown)
Abstract:
X-ray devices are far superior to optical ones for providing nanometre spatial and attosecond temporal resolutions. Such resolution is indispensable in biology, medicine, physics, material sciences, and their applications. A bright ultrafast coherent X-ray source is highly desirable, for example, for the diffractive imaging of individual large molecules, viruses, or cells. Here we demonstrate expe…
▽ More
X-ray devices are far superior to optical ones for providing nanometre spatial and attosecond temporal resolutions. Such resolution is indispensable in biology, medicine, physics, material sciences, and their applications. A bright ultrafast coherent X-ray source is highly desirable, for example, for the diffractive imaging of individual large molecules, viruses, or cells. Here we demonstrate experimentally a new compact X-ray source involving high-order harmonics produced by a relativistic-irradiance femtosecond laser in a gas target. In our first implementation using a 9 Terawatt laser, coherent soft X-rays are emitted with a comb-like spectrum reaching the 'water window' range. The generation mechanism is robust being based on phenomena inherent in relativistic laser plasmas: self-focusing, nonlinear wave generation accompanied by electron density singularities, and collective radiation by a compact electric charge. The formation of singularities (electron density spikes) is described by the elegant mathematical catastrophe theory, which explains sudden changes in various complex systems, from physics to social sciences. The new X-ray source has advantageous scalings, as the maximum harmonic order is proportional to the cube of the laser amplitude enhanced by relativistic self-focusing in plasma. This allows straightforward extension of the coherent X-ray generation to the keV and tens of keV spectral regions. The implemented X-ray source is remarkably easily accessible: the requirements for the laser can be met in a university-scale laboratory, the gas jet is a replenishable debris-free target, and the harmonics emanate directly from the gas jet without additional devices. Our results open the way to a compact coherent ultrashort brilliant X-ray source with single shot and high-repetition rate capabilities, suitable for numerous applications and diagnostics in many research fields.
△ Less
Submitted 26 April, 2010;
originally announced April 2010.
-
Measurement of Single and Double Spin-Flip Probabilities in Inelastic Deuteron Scattering on 12C at 270 MeV
Authors:
Y. Satou,
S. Ishida,
H. Sakai,
H. Okamura,
H. Otsu,
N. Sakamoto,
T. Uesaka,
T. Wakasa,
T. Ohnishi,
K. Sekiguchi,
K. Yako,
T. Ichihara,
T. Niizeki,
K. S. Itoh,
N. Nishimori
Abstract:
The deuteron single and double spin-flip probabilities, S1 and S2, have been measured for the 12C(pol{d},pol{d}') reaction at Ed = 270 MeV for an excitation energy range between 4 and 24 MeV and a scattering angular range between Theta_lab = 2.5 and 7.5 deg. The extracted S1 exhibits characteristic values depending on the structure of the excited state. The S2 is close to zero over the measured…
▽ More
The deuteron single and double spin-flip probabilities, S1 and S2, have been measured for the 12C(pol{d},pol{d}') reaction at Ed = 270 MeV for an excitation energy range between 4 and 24 MeV and a scattering angular range between Theta_lab = 2.5 and 7.5 deg. The extracted S1 exhibits characteristic values depending on the structure of the excited state. The S2 is close to zero over the measured excitation energy range. The SFP angular distribution data for the 2+ (4.44 MeV) and 1+ (12.71 MeV) states are well described by the microscopic DWIA calculations.
△ Less
Submitted 3 October, 2001;
originally announced October 2001.