-
Model-independent measurement of isospin diffusion in Ni-Ni systems at intermediate energy
Authors:
C. Ciampi,
J. D. Frankland,
D. Gruyer,
N. Le Neindre,
S. Mallik,
R. Bougault,
A. Chbihi,
L. Baldesi,
S. Barlini,
E. Bonnet,
B. Borderie,
A. Camaiani,
G. Casini,
I. Dekhissi,
D. Dell'Aquila,
J. A. Dueñas,
Q. Fable,
F. Gramegna,
C. Gouyet,
M. Henri,
B. Hong,
S. Kim,
A. Kordyasz,
T. Kozik,
M. J. Kweon
, et al. (16 additional authors not shown)
Abstract:
In this work we provide a model-independent experimental evaluation of the degree of isospin equilibration taking place in $^{58,64}$Ni+$^{58,64}$Ni collisions at 32 MeV/nucleon across varying reaction centralities. This result has been obtained by combining the complementary information provided by two different datasets, sharing common characteristics. The first dataset has been acquired with th…
▽ More
In this work we provide a model-independent experimental evaluation of the degree of isospin equilibration taking place in $^{58,64}$Ni+$^{58,64}$Ni collisions at 32 MeV/nucleon across varying reaction centralities. This result has been obtained by combining the complementary information provided by two different datasets, sharing common characteristics. The first dataset has been acquired with the INDRA setup and has been used to implement a model-independent reconstruction of the impact parameter. The second dataset has been acquired in the first experimental campaign of the coupled INDRA-FAZIA apparatus at GANIL. The neutron-to-proton content of the quasiprojectile remnant measured by FAZIA has been employed as isospin observable. The effect of isospin diffusion has been evidenced by means of the isospin transport ratio, reported as a function of the impact parameter of the collision. The evolution towards isospin equilibration from semiperipheral to more central collisions is clearly extracted. This experimental result, expanding our previous works (Phys. Rev. C 106, 024603 (2022) and Phys. Rev. C 108, 054611 (2023)), can be compared with the predictions of any transport model, and can thus be used to set constraints on the behavior of the symmetry energy term of the nuclear Equation of State at sub- to saturation densities.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Performance of the prototype beam drift chamber for LAMPS at RAON with proton and Carbon-12 beams
Authors:
H. Kim,
Y. Bae,
C. Heo,
J. Seo,
J. Hwang,
D. H. Moon,
D. S. Ahn,
J. K. Ahn,
J. Bae,
J. Bok,
Y. Cheon,
S. W. Choi,
S. Do,
B. Hong,
S. -W. Hong,
J. Huh,
S. Hwang,
Y. Jang,
B. Kang,
A. Kim,
B. Kim,
C. Kim,
E. -J. Kim,
G. Kim,
G. Kim
, et al. (23 additional authors not shown)
Abstract:
Beam Drift Chamber (BDC) is designed to reconstruct the trajectories of incident rare isotope beams provided by RAON (Rare isotope Accelerator complex for ON-line experiments) into the experimental target of LAMPS (Large Acceptance Multi-Purpose Spectrometer). To conduct the performance test of the BDC, the prototype BDC (pBDC) is manufactured and evaluated with the high energy ion beams from HIMA…
▽ More
Beam Drift Chamber (BDC) is designed to reconstruct the trajectories of incident rare isotope beams provided by RAON (Rare isotope Accelerator complex for ON-line experiments) into the experimental target of LAMPS (Large Acceptance Multi-Purpose Spectrometer). To conduct the performance test of the BDC, the prototype BDC (pBDC) is manufactured and evaluated with the high energy ion beams from HIMAC (Heavy Ion Medical Accelerator in Chiba) facility in Japan. Two kinds of ion beams, 100 MeV proton, and 200 MeV/u $^{12}$C, have been utilized for this evaluation, and the track reconstruction efficiency and position resolution have been measured as the function of applied high voltage. This paper introduces the construction details and presents the track reconstruction efficiency and position resolution of pBDC.
△ Less
Submitted 6 December, 2024;
originally announced December 2024.
-
Study of quasi-projectile properties at Fermi energies in 48Ca projectile systems
Authors:
S. Upadhyaya,
K. Mazurek,
T. Kozik,
D. Gruyer,
G. Casini,
S. Piantelli,
L. Baldesi,
S. Barlini,
B. Borderie,
R. Bougault,
A. Camaiani,
C. Ciampi,
M. Cicerchia,
M. Ciemala,
D. Dell Aquila,
J. A. Duenas,
Q. Fable,
J. D. Frankland,
F. Gramegna,
M. Henri,
B. Hong,
A. Kordyasz,
M. J. Kweon,
N. Le Neindre,
I. Lombardo
, et al. (10 additional authors not shown)
Abstract:
The emission of the pre-equilibrium particles during nuclear collisions at moderate beam energies is still an open question. This influences the properties of the compound nucleus but also changes the interpretation of the quasi-fission process. A systematic analysis of the data obtained by the FAZIA collaboration during a recent experiment with a neutron rich projectile is presented. The full ran…
▽ More
The emission of the pre-equilibrium particles during nuclear collisions at moderate beam energies is still an open question. This influences the properties of the compound nucleus but also changes the interpretation of the quasi-fission process. A systematic analysis of the data obtained by the FAZIA collaboration during a recent experiment with a neutron rich projectile is presented. The full range of charged particles detected in the experiment is within the limit of isotopic resolution of the FAZIA detector. Quasi-projectile (QP) fragments were detected in majority thanks to the forward angular acceptance of the experimental setup which was confirmed by introducing cuts based on the HIPSE event generator calculations. The main goal was to compare the experimental results with the HIPSE simulations after introducing these cuts to investigate the influence of the n-rich entrance channel on the QP fragment properties. More specifically, the lowering of N/Z of QP fragments with beam energy was found to be present since the initial phase of the reaction. Thus, pre-equilibrium emissions might be a possible candidate to explain such an effect.
△ Less
Submitted 14 February, 2024;
originally announced February 2024.
-
Isospin diffusion from $^{40,48}$Ca$+^{40,48}$Ca experimental data at Fermi energies: Direct comparisons with transport model calculations
Authors:
Q. Fable,
L. Baldesi,
S. Barlini,
Eric Bonnet,
Bernard Borderie,
Remi Bougault,
A. Camaiani,
G. Casini,
A. Chbihi,
Caterina Ciampi,
J. A. Dueñas,
J. D. Frankland,
T. Genard,
Diego D. Gruyer,
Maxime Henri,
Byungsik Hong,
S. Kim,
A. J. Kordyasz,
T. Kozik,
Arnaud Le Fèvre,
Nicolas Le Neindre,
Ivano Lombardo,
Olivier Lopez,
T. Marchi,
Paola Marini
, et al. (8 additional authors not shown)
Abstract:
This article presents an investigation of isospin equilibration in cross-bombarding $^{40,48}$Ca$+^{40,48}$Ca reactions at 35 MeV/nucleon, by comparing experimental data with filtered transport model calculations. Isospin diffusion is studied using the evolution of the isospin transport ratio with centrality. The asymmetry parameter $δ=(N-Z)/A$ of the quasiprojectile (QP) residue is used as isospi…
▽ More
This article presents an investigation of isospin equilibration in cross-bombarding $^{40,48}$Ca$+^{40,48}$Ca reactions at 35 MeV/nucleon, by comparing experimental data with filtered transport model calculations. Isospin diffusion is studied using the evolution of the isospin transport ratio with centrality. The asymmetry parameter $δ=(N-Z)/A$ of the quasiprojectile (QP) residue is used as isospin-sensitive observable, while a recent method for impact parameter reconstruction is used for centrality sorting. A benchmark of global observables is proposed to assess the relevance of the antisymmetrized molecular dynamics (AMD) model, coupled to GEMINI++, in the study of dissipative collisions. Our results demonstrate the importance of considering cluster formation to reproduce observables used for isospin transport and centrality studies. Within the AMD model, we prove the applicability of the impact parameter reconstruction method, enabling a direct comparison to the experimental data for the investigation of isospin diffusion. For both, we evidence a tendency to isospin equilibration with an impact parameter decreasing from 9 to 3 fm, while the full equilibration is not reached. A weak sensitivity to the stiffness of the equation of state employed in the model is also observed, with a better reproduction of the experimental trend for the neutron-rich reactions.
△ Less
Submitted 6 June, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
Quasiprojectile breakup and isospin equilibration at Fermi energies: an indication of longer projectile-target contact times?
Authors:
C. Ciampi,
S. Piantelli,
G. Casini,
A. Ono,
J. D. Frankland,
L. Baldesi,
S. Barlini,
B. Borderie,
R. Bougault,
A. Camaiani,
A. Chbihi,
J. A. Dueñas,
Q. Fable,
D. Fabris,
C. Frosin,
T. Génard,
F. Gramegna,
D. Gruyer,
M. Henri,
B. Hong,
S. Kim,
A. Kordyasz,
T. Kozik,
M. J. Kweon,
N. Le Neindre
, et al. (16 additional authors not shown)
Abstract:
An investigation of the quasiprojectile breakup channel in semiperipheral and peripheral collisions of $^{58,64}$Ni+$^{58,64}$Ni at 32 and 52 MeV/nucleon is presented. Data have been acquired in the first experimental campaign of the INDRA-FAZIA apparatus in GANIL. The effect of isospin diffusion between projectile and target in the two asymmetric reactions has been highlighted by means of the iso…
▽ More
An investigation of the quasiprojectile breakup channel in semiperipheral and peripheral collisions of $^{58,64}$Ni+$^{58,64}$Ni at 32 and 52 MeV/nucleon is presented. Data have been acquired in the first experimental campaign of the INDRA-FAZIA apparatus in GANIL. The effect of isospin diffusion between projectile and target in the two asymmetric reactions has been highlighted by means of the isospin transport ratio technique, exploiting the neutron-to-proton ratio of the quasiprojectile reconstructed from the two breakup fragments. We found evidence that, for the same reaction centrality, a higher degree of relaxation of the initial isospin imbalance is achieved in the breakup channel with respect to the more populated binary output, possibly indicating the indirect selection of specific dynamical features. We have proposed an interpretation based on different average projectile-target contact times related to the two exit channels under investigation, with a longer interaction for the breakup channel. The time information has been extracted from AMD simulations of the studied systems coupled to GEMINI++: the model calculations support the hypothesis hereby presented.
△ Less
Submitted 29 August, 2023;
originally announced August 2023.
-
Examination of cluster production in excited light systems at Fermi energies from new experimental data and comparison with transport model calculations
Authors:
C. Frosin,
S. Piantelli,
G. Casini,
A. Ono,
A. Camaiani,
L. Baldesi,
S. Barlini,
B. Borderie,
R. Bougault,
C. Ciampi,
M. Cicerchia,
A. Chbihi,
D. Dell'Aquila,
J. A. Dueñas,
D. Fabris,
Q. Fable,
J. D. Frankland,
T. Génard,
F. Gramegna,
D. Gruyer,
M. Henri,
B. Hong,
M. J. Kweon,
S. Kim,
A. Kordyasz
, et al. (22 additional authors not shown)
Abstract:
Four different reactions, $^{32}$S+$^{12}$C and $^{20}$Ne+$^{12}$C at 25 and 50 MeV/nucleon, have been measured with the FAZIA detector capable of full isotopic identification of most forward emitted reaction products. Fragment multiplicities, angular distributions and energy spectra have been measured and compared with Monte Carlo simulations, i.e. the antisymmetrized molecular dynamics (AMD) and…
▽ More
Four different reactions, $^{32}$S+$^{12}$C and $^{20}$Ne+$^{12}$C at 25 and 50 MeV/nucleon, have been measured with the FAZIA detector capable of full isotopic identification of most forward emitted reaction products. Fragment multiplicities, angular distributions and energy spectra have been measured and compared with Monte Carlo simulations, i.e. the antisymmetrized molecular dynamics (AMD) and the heavy-ion phase space exploration (HIPSE) models. These models are combined with two different afterburner codes (HF$l$ and SIMON) to describe the decay of the excited primary fragments. In the case of AMD, the effect of including the clustering and inter-clustering processes to form bound particles and fragments is discussed. A clear confirmation of the role of cluster aggregation in the reaction dynamics and particle production for these light systems, for which the importance of the clustering process increases with bombarding energy, is obtained.
△ Less
Submitted 30 March, 2023;
originally announced March 2023.
-
Characterization of the breakup channel in the asymmetric systems $^{40,48}$Ca+$^{12}$C at 25 and 40 MeV/nucleon
Authors:
S. Piantelli,
G. Casini,
P. Ottanelli,
L. Baldesi,
S. Barlini,
B. Borderie,
R. Bougault,
A. Camaiani,
A. Chbihi,
C. Ciampi,
J. A. Duenas,
D. Fabris,
Q. Fable,
J. D. Frankland,
C. Frosin,
F. Gramegna,
D. Gruyer,
B. Hong,
A. Kordyasz,
T. Kozik,
M. J. Kweon,
J. Lemarie',
N. LeNeindre,
I. Lombardo,
O. Lopez
, et al. (14 additional authors not shown)
Abstract:
An analysis of the asymmetric reactions $^{40,48}$Ca+$^{12}$C at 25 and 40 MeV/nucleon is presented. Data have been collected with six modules of the FAZIA array. The analysis is focused on the breakup channel of sources produced in dissipative collisions, partially corresponding to incomplete fusion processes. The study has been performed both on detected fragments and on some resonances reconstr…
▽ More
An analysis of the asymmetric reactions $^{40,48}$Ca+$^{12}$C at 25 and 40 MeV/nucleon is presented. Data have been collected with six modules of the FAZIA array. The analysis is focused on the breakup channel of sources produced in dissipative collisions, partially corresponding to incomplete fusion processes. The study has been performed both on detected fragments and on some resonances reconstructed by means of particle-fragment correlations, with a focus on the evolution of the breakup channel with the beam energy and the neutron content of the system, looking in particular at the relative velocity between the breakup fragments. Results show that also
Carbon fragments reconstructed by means of particle correlations can be in large part interpreted as the light partner of a scission.
△ Less
Submitted 23 March, 2023;
originally announced March 2023.
-
Indefinite and Bidirectional Near Infrared Nanocrystal Photoswitching
Authors:
Changhwan Lee,
Emma Z. Xu,
Kevin W. C. Kwock,
Ayelet Teitelboim,
Yawei Liu,
Natalie Fardian-Melamed,
Cassio C. S. Pedroso,
Hye Sun Park,
Jongwoo Kim,
Stefanie D. Pritzl,
Sang Hwan Nam,
Theobald Lohmueller,
Peter Ercius,
Yung Doug Suh,
Bruce E Cohen,
Emory M Chan,
P. James Schuck
Abstract:
Materials whose luminescence can be switched by optical stimulation drive technologies ranging from superresolution imaging1-4, nanophotonics5, and optical data storage6-8, to targeted pharmacology, optogenetics, and chemical reactivity9. These photoswitchable probes, including organic fluorophores and proteins, are prone to photodegradation, and often require phototoxic doses of ultraviolet (UV)…
▽ More
Materials whose luminescence can be switched by optical stimulation drive technologies ranging from superresolution imaging1-4, nanophotonics5, and optical data storage6-8, to targeted pharmacology, optogenetics, and chemical reactivity9. These photoswitchable probes, including organic fluorophores and proteins, are prone to photodegradation, and often require phototoxic doses of ultraviolet (UV) or visible light. Colloidal inorganic nanoparticles have significant stability advantages over existing photoswitchable materials, but the ability to switch emission bidirectionally, particularly with NIR light, has not been reported with nanoparticles. Here, we present 2-way, near-infrared (NIR) photoswitching of avalanching nanoparticles (ANPs), showing full optical control of upconverted emission using phototriggers in the NIR-I and NIR-II spectral regions useful for subsurface imaging. Employing single-step photodarkening10-13 and photobrightening12,14-18, we demonstrate indefinite photoswitching of individual nanoparticles (>1000 cycles over 7 h) in ambient or aqueous conditions without measurable photodegradation. Critical steps of the photoswitching mechanism are elucidated by modeling and by measuring the photon avalanche properties of single ANPs in both bright and dark states. Unlimited, reversible photoswitching of ANPs enables indefinitely rewritable 2D and 3D multi-level optical patterning of ANPs, as well as optical nanoscopy with sub-Å localization superresolution that allows us to distinguish individual ANPs within tightly packed clusters.
△ Less
Submitted 13 September, 2022;
originally announced September 2022.
-
First results from the INDRA-FAZIA apparatus on isospin diffusion in $^{58,64}$Ni+$^{58,64}$Ni systems at Fermi energies
Authors:
C. Ciampi,
S. Piantelli,
G. Casini,
G. Pasquali,
J. Quicray,
L. Baldesi,
S. Barlini,
B. Borderie,
R. Bougault,
A. Camaiani,
A. Chbihi,
D. Dell'Aquila,
M. Cicerchia,
J. A. Dueñas,
Q. Fable,
D. Fabris,
J. D. Frankland,
C. Frosin,
T. Génard,
F. Gramegna,
D. Gruyer,
K. I. Hahn,
M. Henri,
B. Hong,
S. Kim
, et al. (21 additional authors not shown)
Abstract:
An investigation of the isospin equilibration process in the reactions $^{58,64}$Ni+$^{58,64}$Ni at two bombarding energies in the Fermi regime ($32\,$MeV/nucleon and $52\,$MeV/nucleon) is presented. Data have been acquired during the first experimental campaign of the coupled INDRA-FAZIA apparatus in GANIL. Selecting from peripheral to semi-central collisions, both the neutron content of the quas…
▽ More
An investigation of the isospin equilibration process in the reactions $^{58,64}$Ni+$^{58,64}$Ni at two bombarding energies in the Fermi regime ($32\,$MeV/nucleon and $52\,$MeV/nucleon) is presented. Data have been acquired during the first experimental campaign of the coupled INDRA-FAZIA apparatus in GANIL. Selecting from peripheral to semi-central collisions, both the neutron content of the quasiprojectile residue and that of the light ejectiles coming from the quasiprojectile evaporation have been used as probes of the dynamical process of isospin diffusion between projectile and target for the asymmetric systems. The isospin transport ratio technique has been employed. The relaxation of the initial isospin imbalance with increasing centrality has been clearly evidenced. The isospin equilibration appears stronger for the reactions at $32\,$MeV/nucleon, as expected due to the longer projectile-target interaction time than at $52\,$MeV/nucleon. Coherent indications of isospin equilibration come from the quasiprojectile residue characteristics and from particles ascribed to the quasiprojectile decay.
△ Less
Submitted 20 May, 2022;
originally announced May 2022.
-
High temperature mid-IR polarizer via natural in-plane hyperbolic Van der Waals crystals
Authors:
Nihar Ranjan Sahoo,
Saurabh Dixit,
Anuj Kumar Singh,
Sang Hoon Nam,
Nicholas X. Fang,
Anshuman Kumar
Abstract:
Integration of conventional mid to long-wavelength infrared polarizers with chip-scale platforms is restricted by their bulky size and complex fabrication. Van der Waals materials based polarizer can address these challenges due to its non-lithographic fabrication, ease of integration with chip-scale platforms, and room temperature operation. In the present work, mid-IR optical response of the sub…
▽ More
Integration of conventional mid to long-wavelength infrared polarizers with chip-scale platforms is restricted by their bulky size and complex fabrication. Van der Waals materials based polarizer can address these challenges due to its non-lithographic fabrication, ease of integration with chip-scale platforms, and room temperature operation. In the present work, mid-IR optical response of the sub-wavelength thin films of $α$-MoO$_3$ is investigated for application towards high temperature mid-IR transmission and reflection type thin film polarizer. To our knowledge, this is the first report of above room temperature mid-IR optical response of $α$-MoO$_3$ to determine the thermal stability of the proposed device. We find that our $α$-MoO$_3$ based polarizer retains high extinction ratio with peak value exceeding 10 dB, up to a temperature of 140$^{\circ}$C. We explain our experimental findings by natural in-plane hyperbolic anisotropy of $α$-MoO$_3$ in the mid-IR, high temperature X-ray diffraction and Raman spectroscopic measurements. This work opens up new avenues for naturally in-plane hyperbolic van der Waals thin-films to realize sub-wavelength IR optical components without lithographic constraints.
△ Less
Submitted 20 August, 2021; v1 submitted 19 August, 2021;
originally announced August 2021.
-
Isospin diffusion measurement from the direct detection of a Quasi-Projectile remnant
Authors:
A. Camaiani,
G. Casini,
S. Piantelli,
A. Ono,
E. Bonnet,
R. Alba,
S. Barlini,
B. Borderie,
R. Bougault,
C. Ciampi,
A. Chbihi,
M. Cicerchia,
M. Cinausero,
J. A. Dueñas,
D. DellAquila,
Q. Fable,
D. Fabris,
C. Frosin,
J. D. Frankland,
F. Gramegna,
D. Gruyer,
K. I. Hahn,
M. Henri,
B. Hong,
S. Kim
, et al. (18 additional authors not shown)
Abstract:
The neutron-proton equilibration process in 48 Ca+ 40 Ca at 35 MeV/nucleon bombarding energy has been experimentally estimated by means of the isospin transport ratio. Experimental data have been collected with a subset of the FAZIA telescope array, which permitted to determine Z and N of detected fragments. For the first time, the QP evaporative channel has been compared with the QP break-up one…
▽ More
The neutron-proton equilibration process in 48 Ca+ 40 Ca at 35 MeV/nucleon bombarding energy has been experimentally estimated by means of the isospin transport ratio. Experimental data have been collected with a subset of the FAZIA telescope array, which permitted to determine Z and N of detected fragments. For the first time, the QP evaporative channel has been compared with the QP break-up one in a homogeneous and consistent way, pointing out to a comparable n-p equilibration which suggests close interaction time between projectile and target independently of the exit channel. Moreover, in the QP evaporative channel n-p equilibration has been compared with the prediction of the Antisymmetrized Molecular Dynamics (AMD) model coupled to the GEMINI statistical model as an afterburner, showing a larger probability of proton and neutron transfers in the simulation with respect to the experimental data.
△ Less
Submitted 15 January, 2021;
originally announced January 2021.
-
Giant nonlinear optical responses from photon avalanching nanoparticles
Authors:
Changhwan Lee,
Emma Xu,
Yawei Liu,
Ayelet Teitelboim,
Kaiyuan Yao,
Angel Fernandez-Bravo,
Agata Kotulska,
Sang Hwan Nam,
Yung Doug Suh,
Artur Bednarkiewicz,
Bruce E. Cohen,
Emory M. Chan,
P. James Schuck
Abstract:
Avalanche phenomena leverage steeply nonlinear dynamics to generate disproportionately high responses from small perturbations and are found in a multitude of events and materials, enabling technologies including optical phase-conjugate imaging, infrared quantum counting, and efficient upconverted lasing. However, the photon avalanching (PA) mechanism underlying these optical innovations has been…
▽ More
Avalanche phenomena leverage steeply nonlinear dynamics to generate disproportionately high responses from small perturbations and are found in a multitude of events and materials, enabling technologies including optical phase-conjugate imaging, infrared quantum counting, and efficient upconverted lasing. However, the photon avalanching (PA) mechanism underlying these optical innovations has been observed only in bulk materials and aggregates, and typically at cryogenic temperatures, limiting its utility and impact. Here, we report the realization of PA at room temperature in single nanostructures--small, Tm-doped upconverting nanocrystals--and demonstrate their use in superresolution imaging at near-infrared (NIR) wavelengths within spectral windows of maximal biological transparency. Avalanching nanoparticles (ANPs) can be pumped by continuous-wave or pulsed lasers and exhibit all of the defining features of PA. These hallmarks include excitation power thresholds, long rise time at threshold, and a dominant excited-state absorption that is >13,000x larger than ground-state absorption. Beyond the avalanching threshold, ANP emission scales nonlinearly with the 26th power of pump intensity. This enables the realization of photon-avalanche single-beam superresolution imaging (PASSI), achieving sub-70 nm spatial resolution using only simple scanning confocal microscopy and before any computational analysis. Pairing their steep nonlinearity with existing superresolution techniques and computational methods, ANPs allow for imaging with higher resolution and at ca. 100-fold lower excitation intensities than is possible with other probes. The low PA threshold and exceptional photostability of ANPs also suggest their utility in a diverse array of applications including sub-wavelength bioimaging, IR detection, temperature and pressure transduction, neuromorphic computing, and quantum optics.
△ Less
Submitted 20 July, 2020;
originally announced July 2020.
-
Value-assigned pulse shape discrimination for neutron detectors
Authors:
F. C. E. Teh,
J. -W. Lee,
K. Zhu,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
M. B. Tsang,
A. Anthony,
J. Barney,
D. Dell'Aquila,
J. Estee,
B. Hong,
G. Jhang,
O. B. Khanal,
Y. J. Kim,
H. S. Lee,
J. W. Lee,
J. Manfredi,
S. H. Nam,
C. Y. Niu,
J. H. Park,
S. Sweany,
C. Y. Tsang,
R. Wang,
H. Wu
Abstract:
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as…
▽ More
Using the waveforms from a digital electronic system, an offline analysis technique on pulse shape discrimination (PSD) has been developed to improve the neutron-gamma separation in a bar-shaped NE-213 scintillator that couples to a photomultiplier tube (PMT) at each end. The new improved method, called the ``valued-assigned PSD'' (VPSD), assigns a normalized fitting residual to every waveform as the PSD value. This procedure then facilitates the incorporation of longitudinal position dependence of the scintillator, which further enhances the PSD capability of the detector system. In this paper, we use radiation emitted from an AmBe neutron source to demonstrate that the resulting neutron-gamma identification has been much improved when compared to the traditional technique that uses the geometric mean of light outputs from both PMTs. The new method has also been modified and applied to a recent experiment at the National Superconducting Cyclotron Laboratory (NSCL) that uses an analog electronic system.
△ Less
Submitted 17 June, 2021; v1 submitted 15 January, 2020;
originally announced January 2020.
-
Ultrafast fluorescent decay induced by metal-mediated dipole-dipole interaction in two-dimensional molecular aggregates
Authors:
Qing Hu,
Dafei Jin,
Sang Hoon Nam,
Jun Xiao,
Yongmin Liu,
Xiang Zhang,
Nicholas X. Fang
Abstract:
Two-dimensional molecular aggregate (2DMA), a thin sheet of strongly interacting dipole molecules self-assembled at close distance on an ordered lattice, is a fascinating fluorescent material. It is distinctively different from the single or colloidal dye molecules or quantum dots in most previous research. In this paper, we verify for the first time that when a 2DMA is placed at a nanometric dist…
▽ More
Two-dimensional molecular aggregate (2DMA), a thin sheet of strongly interacting dipole molecules self-assembled at close distance on an ordered lattice, is a fascinating fluorescent material. It is distinctively different from the single or colloidal dye molecules or quantum dots in most previous research. In this paper, we verify for the first time that when a 2DMA is placed at a nanometric distance from a metallic substrate, the strong and coherent interaction between the dipoles inside the 2DMA dominates its fluorescent decay at picosecond timescale. Our streak-camera lifetime measurement and interacting lattice-dipole calculation reveal that the metal-mediated dipole-dipole interaction shortens the fluorescent lifetime to about one half and increases the energy dissipation rate by ten times than expected from the noninteracting single-dipole picture. Our finding can enrich our understanding of nanoscale energy transfer in molecular excitonic systems and may designate a new direction for developing fast and efficient optoelectronic devices.
△ Less
Submitted 10 May, 2016; v1 submitted 27 March, 2016;
originally announced March 2016.
-
Evaluation of the clinical usefulness of modulated Arc treatment
Authors:
Young Kyu Lee,
Hong Seok Jang,
Yeon Sil Kim,
Byung Ock Choi,
Sang Hee Nam,
Hyeong Wook Park,
Shin Wook Kim,
Hun Joo Shin,
Jae Choon Lee,
Ji Na Kim,
Sung Kwang Park,
Jin Young Kim,
Young-Nam Kang
Abstract:
The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical usefulness of mARC. A pre study was conducted to find the most competent plan condition of mARC treatment and the usefulness of mARC treatment plan was evaluated by c…
▽ More
The purpose of this study is to evaluate the clinical usefulness of modulated arc (mARC) treatment techniques. The mARC treatment plans of the non-small cell lung cancer (NSCLC) patients were performed in order to verify the clinical usefulness of mARC. A pre study was conducted to find the most competent plan condition of mARC treatment and the usefulness of mARC treatment plan was evaluated by comparing it with the other Arc treatment plans such as Tomotherapy and RapidArc. In the case of mARC, the optimal condition for the mARC plan was determined by comparing the dosimetric performance of the mARC plans with the use of various parameters. The various parameters includes the photon energies (6 MV, 10 MV), optimization point angle (6°-10° intervals), and total segment number (36-59 segment). The best dosimetric performance of mARC was observed at 10 MV photon energy and the point angle 6 degree, and 59 segments. The each treatment plans of three different techniques were compared with the following parameters: conformity index (CI), homogeneity index (HI), target coverage, dose in the OARs, monitor units (MU), beam on time and the normal tissue complication probability (NTCP). As a result, all three different treatment techniques show the similar target coverage. The mARC results the lowest V20 and MU per fraction compared with both RapidArc and Tomotherapy plan. The mARC plan reduces the beam on time as well. Therefore, the results of this study provided a satisfactory result which mARC technique is considered as a useful clinical technique for radiation treatment.
△ Less
Submitted 11 March, 2015;
originally announced March 2015.