-
Imaging and Spectral Performance of a Wide-gap CdTe Double-Sided Strip Detector
Authors:
Shunsaku Nagasawa,
Takahiro Minami,
Shin Watanabe,
Tadayuki Takahashi
Abstract:
The fourth flight of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4) aimed to achieve the first imaging spectroscopic observations of mid-to-large class ( >= GOES C5 class) solar flares, in contrast to the previous three flights that targeted relatively quiet regions of the Sun. To meet the emerging requirements for hard X-ray focal plane detectors for providing simulta…
▽ More
The fourth flight of the Focusing Optics X-ray Solar Imager sounding rocket experiment (FOXSI-4) aimed to achieve the first imaging spectroscopic observations of mid-to-large class ( >= GOES C5 class) solar flares, in contrast to the previous three flights that targeted relatively quiet regions of the Sun. To meet the emerging requirements for hard X-ray focal plane detectors for providing simultaneous diagnostics of spectrally (<1 keV FWHM) and spatially (<50 um) separated coronal and chromospheric emissions from solar flares, we developed a new strip-configuration detector called the wide-gap CdTe semiconductor double-sided strip detector (CdTe-DSD). The wide-gap CdTe-DSD employs a unique design principle to enhance position resolution. This enhancement is realized by expanding the gaps between electrodes to induce charge-sharing across adjacent strip electrodes and using this sharing energy information for position reconstruction to a level finer than the strip-pitch. However, the detector response becomes complex and requires consideration of various factors, such as the charge loss due to wider gaps and the dependence on the depth of photon interaction. Thus, we developed an energy reconstruction method that fully leverages the energy information between adjacent strips and from both the cathode and anode sides, achieving an energy resolution of 0.75 keV (FWHM) at 14 keV. Furthermore, we conducted an X-ray scanning experiment using a synchrotron beam at Spring-8 to evaluate the detector response with a fine scale of 10 um. Based on these results, we established a sub-strip position reconstruction method, demonstrating that X-rays interacting at the center of the gap can be determined with an accuracy of 20 um, and even those at the strip center can be determined with an accuracy of 50 um.
△ Less
Submitted 21 February, 2025;
originally announced February 2025.
-
A Study of Afterglow Signatures in NaI and CsI Scintillator Modules for the Background and Transient Observer Instrument on COSI
Authors:
Hannah Gulick,
Hiroki Yoneda,
Tadayuki Takahashi,
Claire Chen,
Kazuhiro Nakazawa,
Shunsaku Nagasawa,
Mii Ando,
Keigo Okuma,
Alyson Joens,
Samer Al Nussirat,
Yasuyuki Shimizu,
Kaito Fujisawa,
Takayoshi Kohmura,
Kouichi Hagino,
Hisashi Kitamura,
Andreas Zoglauer,
Juan Carlos Martinez Oliveros,
John A. Tomsick
Abstract:
We present measurements of the afterglow signatures in NaI(Tl) and CsI(Tl) detector modules as part of the Background and Transient Observer (BTO) mission detector trade-study. BTO is a NASA Student Collaboration Project flying on the Compton Spectrometer and Imager (COSI) Small Explorer mission in 2027. The detectors utilized in this study are cylindrical in shape with a height and diameter of 5.…
▽ More
We present measurements of the afterglow signatures in NaI(Tl) and CsI(Tl) detector modules as part of the Background and Transient Observer (BTO) mission detector trade-study. BTO is a NASA Student Collaboration Project flying on the Compton Spectrometer and Imager (COSI) Small Explorer mission in 2027. The detectors utilized in this study are cylindrical in shape with a height and diameter of 5.1 cm and were read out by silicon photomultipliers (SiPMs). We conducted a radiation campaign at the HIMAC accelerator in Japan where the scintillators were irradiated with a 230 MeV/u helium beam (He beam) and 350 MeV/u carbon beam (C beam). We find that both the CsI and NaI scintillators exhibit afterglow signatures when irradiated with the C and He beams. The CsI crystal exhibits a stronger afterglow intensity with afterglow pulses occurring for an average 2.40 ms for C and 0.9 ms for He after the initial particle pulse. The duration of afterglow pulses in CsI is 8.6x and 5.6x the afterglow signal duration in NaI for C and He (0.28 ms and 0.16 ms, respectively). Although CsI has advantages such as a higher light yield and radiation hardness, the stronger afterglows in the CsI detector increase the complexity of the electronics and lead to a ~7x larger dead time per afterglow event or a ~3x higher energy threshold value. We use the measured dead times to predict the amount of observing time lost to afterglow-inducing events for an instrument like BTO in low Earth orbit. We simulate the background rates in a BTO-like orbit and find a total value of 114 counts/s for the full two-detector system. Based on the particle energies in the HIMAC experiment, we then determine that an event with sufficient energy to produce an afterglow signal occurs once every ~70 s and ~1.4 s in NaI and CsI detectors, respectively. Thus, we conclude that NaI is the better choice for the BTO mission.
△ Less
Submitted 27 January, 2025;
originally announced January 2025.
-
The energy dependence of cluster size and its physical processes in the proton measurement with TimePix3 silicon detector
Authors:
Naoki Itoh,
Hugo Allaire,
Tokihiro Ikeda,
Shunsaku Nagasawa,
Shinji Okada,
Tadayuki Takahashi,
Aiko Takamine,
Yuichi Toyama,
Yuusuke Uchida,
Hideki Ueno
Abstract:
We investigated the energy dependence of the number of triggered pixels, or cluster size, when charged particles are detected using the TimePix3 detector with a silicon sensor. We measured protons in the range of 1.5~3.3 MeV from a Pelletron accelerator at RIKEN using a TimePix3 detector with a 500 um-thick silicon sensor. We determined from the experimental results a cluster size comprised betwee…
▽ More
We investigated the energy dependence of the number of triggered pixels, or cluster size, when charged particles are detected using the TimePix3 detector with a silicon sensor. We measured protons in the range of 1.5~3.3 MeV from a Pelletron accelerator at RIKEN using a TimePix3 detector with a 500 um-thick silicon sensor. We determined from the experimental results a cluster size comprised between 30 and 80 pixels. To understand the physical process that produces large cluster images and its energy dependence, we simulated the charge carrier drifts in the sensor, assuming the incidence of a proton in the detector. The cluster sizes estimated in the simulation were smaller than those observed in the experiment, and remained constant across the entire energy range, when thermal diffusion and charge carriers self-repulsion were considered as the factors of the cluster image formation. In addition, we discovered that the size of the cluster image and its energy dependence observed in the experiment could be well explained when considering that the TimePix3 detector is sensitive to the transient induced charges, allowing even pixels that do not collect the charge carriers to trigger. We conclude that the cluster size measurement is a promising method for evaluating the energy deposited by a charged particle in the TimePix3 detector.
△ Less
Submitted 19 January, 2025;
originally announced January 2025.
-
Across the soft gamma-ray regime: utilizing simultaneous detections in the Compton Spectrometer and Imager (COSI) and the Background and Transient Observer (BTO) to understand astrophysical transients
Authors:
Hannah C. Gulick,
Eliza Neights,
Samer Al Nussirat,
Claire Tianyi Chen,
Kaylie Ching,
Cassandra Dove,
Alyson Joens,
Carolyn Kierans,
Hubert Liu,
Israel Martinez,
Tomas Mician,
Shunsaku Nagasawa,
Shreya Nandyala,
Isabel Schmidtke,
Derek Shah,
Andreas Zoglauer,
Kazuhiro Nakasawa,
Tadayuki Takahashi,
Juan-Carlos Martinez Oliveros,
John A. Tomsick
Abstract:
The Compton Spectrometer and Imager (COSI) is a NASA funded Small Explorer (SMEX) mission slated to launch in 2027. COSI will house a wide-field gamma-ray telescope designed to survey the entire sky in the 0.2--5 MeV range. Using germanium detectors, the instrument will provide imaging, spectroscopy, and polarimetry of astrophysical sources with excellent energy resolution and degree-scale localiz…
▽ More
The Compton Spectrometer and Imager (COSI) is a NASA funded Small Explorer (SMEX) mission slated to launch in 2027. COSI will house a wide-field gamma-ray telescope designed to survey the entire sky in the 0.2--5 MeV range. Using germanium detectors, the instrument will provide imaging, spectroscopy, and polarimetry of astrophysical sources with excellent energy resolution and degree-scale localization capabilities. In addition to the main instrument, COSI will fly with a student collaboration project known as the Background and Transient Observer (BTO). BTO will extend the COSI bandpass to energies lower than 200 keV, thus enabling spectral analysis across the shared band of 30 keV--2 MeV range. The BTO instrument will consist of two NaI scintillators and student-designed readout electronics. Using spectral information from both the COSI and BTO instruments, physics such as the energy peak turnover in gamma-ray bursts, the characteristics of magnetar flares, and the event frequency of a range of transient phenomena will be constrained. In this paper, we present the expected science returnables from BTO and comment on the shared returnables from the COSI and BTO missions. We include simulations of gamma-ray bursts, magnetar giant flares, and terrestrial gamma-ray flashes using BTO's spectral response. Additionally, we estimate BTO's gamma-ray burst detection rate and find that BTO will detect ~150 gamma-ray bursts per year, with most of these events being long bursts.
△ Less
Submitted 28 August, 2024; v1 submitted 9 July, 2024;
originally announced July 2024.
-
2-mm-Thick Large-Area CdTe Double-sided Strip Detectors for High-Resolution Spectroscopic Imaging of X-ray and Gamma-ray with Depth-Of-Interaction Sensing
Authors:
Takahiro Minami,
Miho Katsuragawa,
Shunsaku Nagasawa,
Shin'ichiro Takeda,
Shin Watanabe,
Yutaka Tsuzuki,
Tadayuki Takahashi
Abstract:
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic…
▽ More
We developed a 2-mm-thick CdTe double-sided strip detector (CdTe-DSD) with a 250 um strip pitch, which has high spatial resolution with a uniform large imaging area of 10 cm$^2$ and high energy resolution with high detection efficiency in tens to hundreds keV. The detector can be employed in a wide variety of fields for quantitative observations of hard X-ray and soft gamma-ray with spectroscopic imaging, for example, space observation, nuclear medicine, and non-destructive elemental analysis. This detector is thicker than the 0.75-mm-thick one previously developed by a factor of $\sim$2.7, thus providing better detection efficiency for hard X-rays and soft gamma rays. The increased thickness could potentially enhance bias-induced polarization if we do not apply sufficient bias and if we do not operate at a low temperature, but the polarization is not evident in our detector when a high voltage of 500 V is applied to the CdTe diode and the temperature is maintained at -20 $^\circ$C during one-day experiments. The ''Depth Of Interaction'' (DOI) dependence due to the CdTe diode's poor carrier-transport property is also more significant, resulting in much DOI information while complicated detector responses such as charge sharings or low-energy tails that exacerbate the loss in the energy resolution.
In this paper, we developed 2-mm-thick CdTe-DSDs, studied their response, and evaluated their energy resolution, spatial resolution, and uniformity. We also constructed a theoretical model to understand the detector response theoretically, resulting in reconstructing the DOI with an accuracy of 100 um while estimating the carrier-transport property. We realized the detector that has high energy resolution and high 3D spatial resolution with a uniform large imaging area.
△ Less
Submitted 17 December, 2023; v1 submitted 13 December, 2023;
originally announced December 2023.
-
Wide-gap CdTe Strip Detectors for High-Resolution Imaging in Hard X-rays
Authors:
Shunsaku Nagasawa,
Takahiro Minami,
Shin Watanabe,
Tadayuki Takahashi
Abstract:
We propose a new strip configuration for CdTe X-ray detectors, named "Wide-gap CdTe strip detector", in which the gap between adjacent strips is much wider than the width of each strip. It has been known that the observed energies of an incoming photon in adjacent strips can be utilized to achieve a position resolution finer than the strip pitch, if and only if the charge cloud induced by an incom…
▽ More
We propose a new strip configuration for CdTe X-ray detectors, named "Wide-gap CdTe strip detector", in which the gap between adjacent strips is much wider than the width of each strip. It has been known that the observed energies of an incoming photon in adjacent strips can be utilized to achieve a position resolution finer than the strip pitch, if and only if the charge cloud induced by an incoming X-ray photon is split into multiple strips and their energies are accurately measured. However, with existing CdTe strip detectors, the ratio of such charge-sharing events is limited. An idea for a potential breakthrough to greatly enhance the ratio of charge-sharing events is to widen the gaps between strips on the detector. To test the concept, we developed a wide-gap CdTe strip detector, which has 64 platinum strip electrodes on the cathode side with some variations in strip pitches from 60 um (30 um strip and 30 um gap width) to 80 um (30 um strip and 50 um gap width). We evaluated the performance depending on the strip pitches by irradiating X-rays from Am-241 on the detector. The charge loss due to the wider gaps on the detector was found to be significant to the extent that the assumption that the energy of an incoming photon for a charge-sharing event was the simple sum of the energies detected in adjacent strips lead to a significant degradation in the energy resolution in the accumulated spectrum, compared with those obtained with its predecessor having standard gap-widths. We then developed a new energy-reconstruction method to compensate for the charge loss. Application of the method to the data yielded a spectrum with a comparable spectral resolution with that of the predecessor. The ratio of the charge-sharing events for 17.8 keV events was doubled from that of the predecessor, from 24.3 to 49.9 percent.
△ Less
Submitted 2 March, 2023; v1 submitted 28 February, 2023;
originally announced February 2023.
-
Study of Time Evolution of Thermal and Non-Thermal Emission from an M-Class Solar Flare
Authors:
Shunsaku Nagasawa,
Tomoko Kawate,
Noriyuki Narukage,
Tadayuki Takahashi,
Amir Caspi,
Thomas N. Woods
Abstract:
We conduct a wide-band X-ray spectral analysis in the energy range of 1.5-100 keV to study the time evolution of the M7.6 class flare of 2016 July 23, with the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat and the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft. With the combination of MinXSS for soft X-rays and RHESSI for hard X-rays, a non-thermal component and thr…
▽ More
We conduct a wide-band X-ray spectral analysis in the energy range of 1.5-100 keV to study the time evolution of the M7.6 class flare of 2016 July 23, with the Miniature X-ray Solar Spectrometer (MinXSS) CubeSat and the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft. With the combination of MinXSS for soft X-rays and RHESSI for hard X-rays, a non-thermal component and three-temperature multi-thermal component -- "cool" ($T \approx$ 3 MK), "hot" ($T \approx$ 15 MK), and "super-hot" ($T \approx$ 30 MK) -- were measured simultaneously. In addition, we successfully obtained the spectral evolution of the multi-thermal and non-thermal components with a 10 s cadence, which corresponds to the Alfvén time scale in the solar corona. We find that the emission measures of the cool and hot thermal components are drastically increasing more than hundreds of times and the super-hot thermal component is gradually appearing after the peak of the non-thermal emission. We also study the microwave spectra obtained by the Nobeyama Radio Polarimeters (NoRP), and we find that there is continuous gyro-synchrotron emission from mildly relativistic non-thermal electrons. In addition, we conducted a differential emission measure (DEM) analysis by using Atmospheric Imaging Assembly (AIA) onboard the Solar Dynamics Observatory (SDO) and determine that the DEM of cool plasma increases within the flaring loop. We find that the cool and hot plasma components are associated with chromospheric evaporation. The super-hot plasma component could be explained by the thermalization of the non-thermal electrons trapped in the flaring loop.
△ Less
Submitted 28 May, 2022;
originally announced May 2022.
-
Uncertainty Relation and Minimum Wave Packet on Circle
Authors:
Naohisa Ogawa,
Shuichi Nagasawa
Abstract:
We discuss on the uncertainty relation (UR) for a closed one dimensional system (circle). In such a system, we cannot use the angle along the circle as a position variable. Otherwise we meet difficulties about the definition of the average position and the standard deviation (SD), and Hermitian property of angular momentum. From these reasons, we define the position variable as Cartesian variable…
▽ More
We discuss on the uncertainty relation (UR) for a closed one dimensional system (circle). In such a system, we cannot use the angle along the circle as a position variable. Otherwise we meet difficulties about the definition of the average position and the standard deviation (SD), and Hermitian property of angular momentum. From these reasons, we define the position variable as Cartesian variable $(X,Y)$ that have the periodic property for angle $φ$. In the same way we define a SD by using that variables. Then we obtain two URs. We also discuss the minimum wave packet (MWP) on the circle. MWPs are expressed by von Mises distribution functions. Next we construct total URs by combining two URs for $X$ and $Y$. Furthermore, we extend the variables to $(X_n, Y_n)$ \; with $n= 1,2,3,\cdots$ and we have infinite series of total URs. We consider the meaning of such extended URs.
△ Less
Submitted 13 March, 2023; v1 submitted 13 March, 2022;
originally announced March 2022.
-
Experimental Demonstrations of Native Implementation of Boolean Logic Hamiltonian in a Superconducting Quantum Annealer
Authors:
Daisuke Saida,
Yuki Yamanashi,
Mutsuo Hidaka,
Fuminori Hirayama,
Kentaro Imafuku,
Shuichi Nagasawa,
Shiro Kawabata
Abstract:
Experimental demonstrations of quantum annealing with native implementation of Boolean logic Hamiltonians are reported. As a superconducting integrated circuit, a problem Hamiltonian whose set of ground states is consistent with a given truth table is implemented for quantum annealing with no redundant qubits. As examples of the truth table, NAND and NOR are successfully fabricated as an identical…
▽ More
Experimental demonstrations of quantum annealing with native implementation of Boolean logic Hamiltonians are reported. As a superconducting integrated circuit, a problem Hamiltonian whose set of ground states is consistent with a given truth table is implemented for quantum annealing with no redundant qubits. As examples of the truth table, NAND and NOR are successfully fabricated as an identical circuit. Similarly, a native implementation of a multiplier comprising six superconducting flux qubits is also demonstrated. These native implementations of Hamiltonians consistent with Boolean logic provide an efficient and scalable way of applying annealing computation to so-called circuit satisfiability problems that aim to find a set of inputs consistent with a given output over any Boolean logic functions, especially those like factorization through a multiplier Hamiltonian. A proof-of-concept demonstration of a hybrid computing architecture for domain-specific quantum computing is described.
△ Less
Submitted 17 June, 2021; v1 submitted 16 June, 2021;
originally announced June 2021.
-
Catalog of Long-Term Transient Sources in the First 10 Years of Fermi-LAT Data
Authors:
L. Baldini,
J. Ballet,
D. Bastieri,
J. Becerra Gonzalez,
R. Bellazzini,
A. Berretta,
E. Bissaldi,
R. D. Blandford,
E. D. Bloom,
R. Bonino,
E. Bottacini,
P. Bruel,
S. Buson,
R. A. Cameron,
P. A. Caraveo,
E. Cavazzuti,
S. Chen,
G. Chiaro,
D. Ciangottini,
S. Ciprini,
P. Cristarella Orestano,
M. Crnogorcevic,
S. Cutini,
F. D'Ammando,
P. de la Torre Luque
, et al. (90 additional authors not shown)
Abstract:
We present the first Fermi Large Area Telescope (LAT) catalog of long-term $γ$-ray transient sources (1FLT). This comprises sources that were detected on monthly time intervals during the first decade of Fermi-LAT operations. The monthly time scale allows us to identify transient and variable sources that were not yet reported in other Fermi-LAT catalogs. The monthly datasets were analyzed using a…
▽ More
We present the first Fermi Large Area Telescope (LAT) catalog of long-term $γ$-ray transient sources (1FLT). This comprises sources that were detected on monthly time intervals during the first decade of Fermi-LAT operations. The monthly time scale allows us to identify transient and variable sources that were not yet reported in other Fermi-LAT catalogs. The monthly datasets were analyzed using a wavelet-based source detection algorithm that provided the candidate new transient sources. The search was limited to the extragalactic regions of the sky to avoid the dominance of the Galactic diffuse emission at low Galactic latitudes. The transient candidates were then analyzed using the standard Fermi-LAT Maximum Likelihood analysis method. All sources detected with a statistical significance above 4$σ$ in at least one monthly bin were listed in the final catalog. The 1FLT catalog contains 142 transient $γ$-ray sources that are not included in the 4FGL-DR2 catalog. Many of these sources (102) have been confidently associated with Active Galactic Nuclei (AGN): 24 are associated with Flat Spectrum Radio Quasars; 1 with a BL Lac object; 70 with Blazars of Uncertain Type; 3 with Radio Galaxies; 1 with a Compact Steep Spectrum radio source; 1 with a Steep Spectrum Radio Quasar; 2 with AGN of other types. The remaining 40 sources have no candidate counterparts at other wavelengths. The median $γ$-ray spectral index of the 1FLT-AGN sources is softer than that reported in the latest Fermi-LAT AGN general catalog. This result is consistent with the hypothesis that detection of the softest $γ$-ray emitters is less efficient when the data are integrated over year-long intervals.
△ Less
Submitted 31 May, 2021;
originally announced June 2021.
-
Imaging and Spectral Performance of a 60 μm Pitch CdTe Double-Sided Strip Detector
Authors:
Kento Furukawa,
Shunsaku Nagasawa,
Lindsay Glesener,
Miho Katsuragawa,
Shin'ichiro Takeda,
Shin Watanabe,
Tadayuki Takahashi
Abstract:
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of…
▽ More
We have evaluated the performance of a fine pitch CdTe Double-sided Strip Detector (CdTe-DSD), which was originally developed for the focal plane detector of a hard X-ray telescope to observe the Sun. The detector has a thickness of 750 um and has 128 strip electrodes with a 60 um strip pitch orthogonally placed on both sides of the detector and covers an energy range 4 keV to 80 keV. The study of the depth of photon interaction and charge sharing effects are of importance in order to provide good spectroscopic and imaging performance. We study the tail structure observed in the spectra caused by charge trapping and develop a new method to reconstruct the spectra based on induced charge information from both anode and cathode strips. By applying this method, energy resolutions (FWHM) of 0.76 keV and 1.0 keV can be obtained at photon energies of 14 keV and 60 keV, respectively, if the energy difference between the anode and cathode is within 1 keV. Furthermore, the tail component at 60 keV is reduced, and the energy resolution of the 60 keV peak is improved from 2.4 keV to 1.5 keV (FWHM) if the energy difference is greater than 1 keV. In order to study the imaging performance, we constructed a simple imaging system using a 5 mm thick tungsten plate that has a pinhole with a diameter of 100 um. We utilize a Ba-133 radioisotope of 1 mm in diameter as a target source in combination with a 100 um slit made from 0.5 mm thickness tungsten. We imaged the Ba-133 source behind the 100 um slit using a 30 keV peak, with a 100 um pinhole placed at the center of the source-detector distance. By applying a charge sharing correction between strips, we have succeeded in obtaining a position resolution better than the strip pitch of 60 um.
△ Less
Submitted 10 June, 2020;
originally announced June 2020.
-
Toward Practical-Scale Quantum Annealing Machine for Prime Factoring
Authors:
Masaaki Maezawa,
Go Fujii,
Mutsuo Hidaka,
Kentaro Imafuku,
Katsuya Kikuchi,
Hanpei Koike,
Kazumasa Makise,
Shuichi Nagasawa,
Hiroshi Nakagawa,
Masahiro Ukibe,
Shiro Kawabata
Abstract:
We propose a prime factorizer operated in a framework of quantum annealing (QA). The idea is inverse operation of a multiplier implemented with QA-based Boolean logic circuits. We designed the QA machine on an application-specific-annealing-computing architecture which efficiently increases available hardware budgets at the cost of restricted functionality. The invertible operation of QA logic gat…
▽ More
We propose a prime factorizer operated in a framework of quantum annealing (QA). The idea is inverse operation of a multiplier implemented with QA-based Boolean logic circuits. We designed the QA machine on an application-specific-annealing-computing architecture which efficiently increases available hardware budgets at the cost of restricted functionality. The invertible operation of QA logic gates consisting of superconducting flux qubits was confirmed by circuit simulation with classical noise sources. The circuits were implemented and fabricated by using superconducting integrated circuit technologies with Nb/AlOx/Nb Josephson junctions. We also propose a 2.5Dimensional packaging scheme of a qubit-chip/interpose /package-substrate structure for realizing practically large-scale QA systems.
△ Less
Submitted 5 September, 2018;
originally announced September 2018.
-
Flux avalanches in Nb superconducting shifted strip arrays
Authors:
Y. Tsuchiya,
Y. Mawatari,
J. Ibuka,
S. Tada,
S. Pyon,
S. Nagasawa,
M. Hidaka,
M. Maezawa,
T. Tamegai
Abstract:
Flux penetrations into three-dimensional Nb superconducting strip arrays, where two layers of strip arrays are stacked by shifting a half period, are studied using a magneto-optical imaging method. Flux avalanches are observed when the overlap between the top and bottom layers is large even if the width of each strip is well below the threshold value. In addition, anomalous linear avalanches perpe…
▽ More
Flux penetrations into three-dimensional Nb superconducting strip arrays, where two layers of strip arrays are stacked by shifting a half period, are studied using a magneto-optical imaging method. Flux avalanches are observed when the overlap between the top and bottom layers is large even if the width of each strip is well below the threshold value. In addition, anomalous linear avalanches perpendicular to the strip are observed in the shifted strip array when the overlap is very large and the thickness of the superconductor is greater than the penetration depth. We discuss possible origins for the flux avalanches, including linear ones, by considering flux penetration calculated by the Campbell method assuming the Bean model.
△ Less
Submitted 24 July, 2013;
originally announced July 2013.
-
Dissipation Under the Magnetic Field on 2D Surface
Authors:
Naohisa Ogawa,
Shu-ichi Nagasawa
Abstract:
It is well known that the convection of liquid solution or melt liquid is inhibited by the magnetic field experimentally, and so that we can make the larger and better crystals at the cost of slow growth rate. We shall show here another two effects due to the magnetic field. First, when the ionised molecule diffuses on the surface of crystal under the magnetic field applied normal to the surface…
▽ More
It is well known that the convection of liquid solution or melt liquid is inhibited by the magnetic field experimentally, and so that we can make the larger and better crystals at the cost of slow growth rate. We shall show here another two effects due to the magnetic field. First, when the ionised molecule diffuses on the surface of crystal under the magnetic field applied normal to the surface,its diffusion constant decreases due to the magnetic effect. Second, even if the molecule has no electric charge, if it has electric dipole moment, the kinetic energy decreases by different mechanism.
△ Less
Submitted 28 March, 2007;
originally announced March 2007.