-
Improved measurements of neutron lifetime with cold neutron beam at J-PARC
Authors:
Y. Fuwa,
T. Hasegawa,
K. Hirota,
T. Hoshino,
R. Hosokawa,
G. Ichikawa,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
R. Kitahara,
S. Makise,
K. Mishima,
T. Mogi,
N. Nagakura,
H. Oide,
H. Okabe,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. E. Shimizu,
H. M. Shimizu,
N. Sumi,
H. Sumino
, et al. (6 additional authors not shown)
Abstract:
The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of ne…
▽ More
The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $τ_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$σ$ tension with the average value obtained from the proton-detection-based beam method.
△ Less
Submitted 27 December, 2024;
originally announced December 2024.
-
Measurement of $γ$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector
Authors:
J. Koga,
S. Ieki,
A. Kimura,
M. Kitaguchi,
R. Kitahara,
K. Mishima,
N. Nagakura,
T. Okudaira,
H. Otono,
H. M. Shimizu,
N. Sumi,
S. Takada,
T. Tomita,
T. Yamada,
T. Yoshioka
Abstract:
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress th…
▽ More
A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $γ$ rays. In order to estimate the amount of $γ$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $γ$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $γ$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $γ$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.
△ Less
Submitted 30 July, 2020;
originally announced July 2020.
-
Neutron lifetime measurement with pulsed cold neutrons
Authors:
K. Hirota,
G. Ichikawa,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
R. Kitahara,
J. Koga,
K. Mishima,
T. Mogi,
K. Morikawa,
A. Morishita,
N. Nagakura,
H. Oide,
H. Okabe,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
T. Tomita,
H. Uehara,
T. Yamada
, et al. (4 additional authors not shown)
Abstract:
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas c…
▽ More
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.
△ Less
Submitted 25 November, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement
Authors:
R. Kitahara,
K. Hirota,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
J. Koga,
K. Mishima,
A. Morishita,
N. Nagakura,
H. Oide,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
K. Taketani,
T. Tomita,
T. Yamada,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of…
▽ More
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement.
In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.
△ Less
Submitted 2 August, 2019; v1 submitted 26 April, 2019;
originally announced April 2019.
-
Accurate determination of the absolute 3He/4He ratio of a synthesized helium standard gas (Helium Standard of Japan, HESJ): Towards revision of the atmospheric 3He/4He ratio
Authors:
Kenji Mishima,
Hirochika Sumino,
Takahito Yamada,
Sei Ieki,
Naoki Nagakura,
Hidetoshi Otono,
Hideyuki Oide
Abstract:
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accur…
▽ More
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accuracy of the absolute 3He/4He ratios of the atmosphere and other working standards including HESJ is crucial in some applications of helium isotopes, such as tritium-3He dating, surface-exposure age determination based on cosmogenic 3He, and the accurate measurement of the neutron lifetime. In this work, new control samples of helium gases with 3He/4He ratios of 14, 28, and 42 ppm were fabricated with accuracy of 0.25-0.38% using a gas-handling system for a neutron lifetime experiment at Japan Proton Accelerator Research Complex (J-PARC). The relative 3He/4He ratios of these samples and the HESJ were measured using a magnetic-sector-type, single-focusing, noble gas mass spectrometer with a double collector system. As a result, the absolute 3He/4He ratio of the HESJ was determined as 27.36 +/- 0.11 ppm. The atmospheric 3He/4He ratio was determined as 1.340 +/- 0.006 ppm, based on this work.
△ Less
Submitted 2 October, 2018; v1 submitted 21 April, 2018;
originally announced April 2018.
-
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
Authors:
Kenji Mishima,
Shogo Awano,
Yasuhiro Fuwa,
Fumiya Goto,
Christopher C. Haddock,
Masahiro Hino,
Masanori Hirose,
Katsuya Hirota,
Sei Ieki,
Sohei Imajo,
Takashi Ino,
Yoshihisa Iwashita,
Ryo Katayama,
Hiroaki Kawahara,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Jun Koga,
Aya Morishita,
Tomofumi Nagae,
Naoki Nagakura,
Naotaka Naganawa,
Noriko Oi,
Hideyuki Oide,
Hidetoshi Otono,
Yoshichika Seki
, et al. (15 additional authors not shown)
Abstract:
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The…
▽ More
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are developing an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The neutron lifetime is an important parameter in elementary particle and astrophysics. Thus far, the neutron lifetime has been measured by several groups; however, different values are obtained from different measurement methods. This experiment is using a method with different sources of systematic uncertainty than measurements conducted to date. We are also developing a source of pulsed ultra-cold neutrons (UCNs) produced from a Doppler shifter are available at the unpolarized beam branch. We are developing a time focusing device for UCNs, a so called "rebuncher", which can increase UCN density from a pulsed UCN source. At the low divergence beam branch, an experiment to search an unknown intermediate force with nanometer range is performed by measuring the angular dependence of neutron scattering by noble gases. Finally the beamline is also used for the research and development of optical elements and detectors. For example, a position sensitive neutron detector that uses emulsion to achieve sub-micrometer resolution is currently under development. We have succeeded in detecting cold and ultra-cold neutrons using the emulsion detector.
△ Less
Submitted 25 January, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Precise neutron lifetime experiment using pulsed neutron beams at J-PARC
Authors:
Naoki Nagakura,
Katsuya Hirota,
Sei Ieki,
Takashi Ino,
Yoshihisa Iwashita,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Kenji Mishima,
Aya Morishita,
Hideyuki Oide,
Hidetoshi Otono,
Risa Sakakibara,
Yoshichika Seki,
Tatsushi Shima,
Hirohiko M. Shimizu,
Tomoaki Sugino,
Naoyuki Sumi,
Hiroshima Sumino,
Kaoru Taketani,
Genki Tanaka,
Tatsuhiko Tomita,
Takahito Yamada,
Satoru Yamashita,
Mami Yokohashi,
Tamaki Yoshioka
Abstract:
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in…
▽ More
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in 2016, which is expected to yield a statistical uncertainty of O(1)%. This paper presents the current analysis results and the future plans to achieve our goal precision.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.