-
Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode
Authors:
Megumi Shidatsu,
Yukikatsu Terada,
Takashi Kominato,
So Kato,
Ryohei Sato,
Minami Sakama,
Takumi Shioiri,
Yugo Motogami,
Yuuki Niida,
Chulsoo Kang,
Toshihiro Takagi,
Taichi Nakamoto,
Chikara Natsukari,
Makoto S. Tashiro,
Kenichi Toda,
Hironori Maejima,
Shin Watanabe,
Ryo Iizuka,
Rie Sato,
Chris Baluta,
Katsuhiro Hayashi,
Tessei Yoshida,
Shoji Ogawa,
Yoshiaki Kanemaru,
Kotaro Fukushima
, et al. (37 additional authors not shown)
Abstract:
We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperatur…
▽ More
We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperature-versus-clock frequency trend. Comparing the time values calculated from the data and the true GPS times when the data were obtained, we confirmed that the requirement (within a 350 $μ$s error in the absolute time, accounting for both the spacecraft bus system and the ground system) was satisfied in the temperature conditions of the thermal vacuum test. We also simulated the variation of the timing accuracy in the on-orbit temperature conditions using the Hitomi on-orbit temperature data and found that the error remained within the requirement over $\sim 3 \times 10^{5}$ s. The on-orbit tests were conducted in 2023 September and October as part of the bus system checkout. The temperature versus clock frequency trend remained unchanged from that obtained in the thermal vacuum test and the observed time drift was consistent with that expected from the trend.
△ Less
Submitted 3 June, 2025;
originally announced June 2025.
-
Development of the Timing System for the X-Ray Imaging and Spectroscopy Mission
Authors:
Yukikatsu Terada,
Megumi Shidatsu,
Makoto Sawada,
Takashi Kominato,
So Kato,
Ryohei Sato,
Minami Sakama,
Takumi Shioiri,
Yuki Niida,
Chikara Natsukari,
Makoto S Tashiro,
Kenichi Toda,
Hironori Maejima,
Katsuhiro Hayashi,
Tessei Yoshida,
Shoji Ogawa,
Yoshiaki Kanemaru,
Akio Hoshino,
Kotaro Fukushima,
Hiromitsu Takahashi,
Masayoshi Nobukawa,
Tsunefumi Mizuno,
Kazuhiro Nakazawa,
Shin'ichiro Uno,
Ken Ebisawa
, et al. (40 additional authors not shown)
Abstract:
This paper describes the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0~ms. All components of the timing system were designed and verified to be within the timing error budgets, whi…
▽ More
This paper describes the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0~ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR~B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below $15~μ$s compared to the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within $200~μ$s. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of $500~μ$s.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
The High Energy X-ray Probe (HEX-P): Supernova remnants, pulsar wind nebulae, and nuclear astrophysics
Authors:
Stephen Reynolds,
Hongjun An,
Moaz Abdelmaguid,
Jason Alford,
Chris L. Fryer,
Kaya Mori,
Melania Nynka,
Jaegeun Park,
Yukikatsu Terada,
Jooyun Woo,
Aya Bamba,
Priyadarshini Bangale,
Rebecca Diesing,
Jordan Eagle,
Stefano Gabici,
Joseph Gelfand,
Brian Grefenstette,
Javier Garcia,
Chanho Kim,
Sajan Kumar,
Brydyn Mac Intyre,
Kristin Madsen,
Silvia Manconi,
Yugo Motogami,
Hayato Ohsumi
, et al. (7 additional authors not shown)
Abstract:
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging ($<10"$ full width at half maximum) and broad spectral coverage (0.2--80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. HEX-P is ideally suited to address important p…
▽ More
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging ($<10"$ full width at half maximum) and broad spectral coverage (0.2--80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. HEX-P is ideally suited to address important problems in the physics and astrophysics of supernova remnants (SNRs) and pulsar-wind nebulae (PWNe). For shell SNRs, HEX-P can greatly improve our understanding via more accurate spectral characterization and localization of non-thermal X-ray emission from both non-thermal-dominated SNRs and those containing both thermal and non-thermal components, and can discover previously unknown non-thermal components in SNRs. Multi-epoch HEX-P observations of several young SNRs (e.g., Cas A and Tycho) are expected to detect year-scale variabilities of X-ray filaments and knots, thus enabling us to determine fundamental parameters related to diffusive shock acceleration, such as local magnetic field strengths and maximum electron energies. For PWNe, HEX-P will provide spatially-resolved, broadband X-ray spectral data separately from their pulsar emission, allowing us to study how particle acceleration, cooling, and propagation operate in different evolution stages of PWNe. HEX-P is also poised to make unique and significant contributions to nuclear astrophysics of Galactic radioactive sources by improving detections of, or limits on, $^{44}$Ti in the youngest SNRs and by potentially discovering rare nuclear lines as evidence of double neutron star mergers. Throughout the paper, we present simulations of each class of objects, demonstrating the power of both the imaging and spectral capabilities of HEX-P to advance our knowledge of SNRs, PWNe, and nuclear astrophysics.
△ Less
Submitted 8 November, 2023;
originally announced November 2023.
-
The High Energy X-ray Probe (HEX-P): Galactic PeVatrons, star clusters, superbubbles, microquasar jets, and gamma-ray binaries
Authors:
Kaya Mori,
Stephen Reynolds,
Hongjun An,
Aya Bamba,
Roman Krivonos,
Naomi Tsuji,
Moaz Abdelmaguid,
Jason Alford,
Priyadarshini Bangale,
Silvia Celli,
Rebecca Diesing,
Jordan Eagle,
Chris L. Fryer,
Stefano Gabici,
Joseph Gelfand,
Brian Grefenstette,
Javier Garcia,
Chanho Kim,
Sajan Kumar,
Ekaterina Kuznetsova,
Brydyn Mac Intyre,
Kristin Madsen,
Silvia Manconi,
Yugo Motogami,
Hayato Ohsumi
, et al. (10 additional authors not shown)
Abstract:
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2-80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sour…
▽ More
HEX-P is a probe-class mission concept that will combine high spatial resolution X-ray imaging (<10" FWHM) and broad spectral coverage (0.2-80 keV) with an effective area far superior to current facilities (including XMM-Newton and NuSTAR) to enable revolutionary new insights into a variety of important astrophysical problems. With the recent discoveries of over 40 ultra-high-energy gamma-ray sources (detected above 100 TeV) and neutrino emission in the Galactic Plane, we have entered a new era of multi-messenger astrophysics facing the exciting reality of Galactic PeVatrons. In the next decade, as more Galactic PeVatrons and TeV gamma-ray sources are expected to be discovered, the identification of their acceleration and emission mechanisms will be the most pressing issue in both particle and high-energy astrophysics. In this paper, along with its companion papers (Reynolds et al. 2023, Mori et al. 2023), we will present that HEX-P is uniquely suited to address important problems in various cosmic-ray accelerators, including Galactic PeVatrons, through investigating synchrotron X-ray emission of TeV-PeV electrons produced by both leptonic and hadronic processes.
△ Less
Submitted 8 November, 2023;
originally announced November 2023.