-
Operation and performance of MEG II detector
Authors:
MEG II Collaboration,
K. Afanaciev,
A. M. Baldini,
S. Ban,
V. Baranov,
H. Benmansour,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
A. Corvaglia,
F. Cuna,
G. Dal Maso,
A. De Bari,
M. De Gerone,
L. Ferrari Barusso,
M. Francesconi,
L. Galli,
G. Gallucci,
F. Gatti,
L. Gerritzen,
F. Grancagnolo
, et al. (60 additional authors not shown)
Abstract:
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation…
▽ More
The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.
△ Less
Submitted 8 January, 2024; v1 submitted 18 October, 2023;
originally announced October 2023.
-
GINGER
Authors:
Carlo Altucci,
Francesco Bajardi Emilio Barchiesi,
Andrea Basti,
Nicolò Beverini,
Thomas Braun,
Giorgio Carelli,
Salvatore Capozziello,
Donatella Ciampini,
Fabrizio Davì,
Gaetano De Luca,
Roberto Devoti,
Rita Di Giovambattista,
Giuseppe Di Somma,
Giuseppe Di Stefano,
Angela D. V. Di Virgilio,
Daniela Famiani,
Alberto Frepoli,
Francesco Fuso,
Ivan Giorgio,
Aladino Govoni,
Gaetano Lambiase,
Enrico Maccioni,
Paolo Marsili,
Alessia Mercuri,
Fabio Morsani
, et al. (7 additional authors not shown)
Abstract:
In this paper, we outline the scientific objectives, the experimental layout, and the collaborations envisaged for the GINGER (Gyroscopes IN GEneral Relativity) project. The GINGER project brings together different scientific disciplines aiming at building an array of Ring Laser Gyroscopes (RLGs), exploiting the Sagnac effect, to measure continuously, with sensitivity better than picorad/ s, large…
▽ More
In this paper, we outline the scientific objectives, the experimental layout, and the collaborations envisaged for the GINGER (Gyroscopes IN GEneral Relativity) project. The GINGER project brings together different scientific disciplines aiming at building an array of Ring Laser Gyroscopes (RLGs), exploiting the Sagnac effect, to measure continuously, with sensitivity better than picorad/ s, large bandwidth (ca. 1 kHz), and high dynamic range, the absolute angular rotation rate of the Earth. In the paper, we address the feasibility of the apparatus with respect to the ambitious specifications above, as well as prove how such an apparatus, which will be able to detect strong Earthquakes, very weak geodetic signals, as well as general relativity effects like Lense-Thirring and De Sitter, will help scientific advancements in Theoretical Physics, Geophysics, and Geodesy, among other scientific fields.
△ Less
Submitted 19 September, 2022;
originally announced September 2022.
-
The WaveDAQ integrated Trigger and Data Acquisition System for the MEG II experiment
Authors:
Marco Francesconi,
Alessandro Massimo Baldini,
Fabrizio Cei,
Marco Chiappini,
Luca Galli,
Marco Grassi,
Ueli Hartmann,
Manuel Meucci,
Fabio Morsani,
Donato Nicolò,
Angela Papa,
Stefan Ritt,
Elmar Schmid,
Giovanni Signorelli
Abstract:
The WaveDAQ is a newly-designed digitization Trigger and Data AcQuisition system (TDAQ) allowing Multi-gigasample waveform recording on a large amount of channels (up to 16384) by using the DRS4 analog switched capacitor array as downconverting ASIC. A high bandwidth, programmable input stage has been coupled with a bias generator to allow SiPM operation without need of any other external apparatu…
▽ More
The WaveDAQ is a newly-designed digitization Trigger and Data AcQuisition system (TDAQ) allowing Multi-gigasample waveform recording on a large amount of channels (up to 16384) by using the DRS4 analog switched capacitor array as downconverting ASIC. A high bandwidth, programmable input stage has been coupled with a bias generator to allow SiPM operation without need of any other external apparatus. The trigger generation is tightly coupled within the system to limit the required depth of the analog memory, allowing faster digitization speeds. This system has been designed for the MEG experiment upgrade but also proved to be highly scalable and already found other applications.
△ Less
Submitted 24 June, 2018;
originally announced June 2018.
-
The design of the MEG II experiment
Authors:
A. M. Baldini,
E. Baracchini,
C. Bemporad,
F. Berg,
M. Biasotti,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
M. Chiappini,
G. Chiarello,
C. Chiri,
G. Cocciolo,
A. Corvaglia,
A. de Bari,
M. De Gerone,
A. D'Onofrio,
M. Francesconi,
Y. Fujii,
L. Galli,
F. Gatti,
F. Grancagnolo,
M. Grassi,
D. N. Grigoriev,
M. Hildebrandt
, et al. (55 additional authors not shown)
Abstract:
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation…
▽ More
The MEG experiment, designed to search for the mu+->e+ gamma decay at a 10^-13 sensitivity level, completed data taking in 2013. In order to increase the sensitivity reach of the experiment by an order of magnitude to the level of 6 x 10-14 for the branching ratio, a total upgrade, involving substantial changes to the experiment, has been undertaken, known as MEG II. We present both the motivation for the upgrade and a detailed overview of the design of the experiment and of the expected detector performance.
△ Less
Submitted 15 January, 2018;
originally announced January 2018.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Trapping in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trapping rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trapping rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trapping rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
The Physics of the B Factories
Authors:
A. J. Bevan,
B. Golob,
Th. Mannel,
S. Prell,
B. D. Yabsley,
K. Abe,
H. Aihara,
F. Anulli,
N. Arnaud,
T. Aushev,
M. Beneke,
J. Beringer,
F. Bianchi,
I. I. Bigi,
M. Bona,
N. Brambilla,
J. B rodzicka,
P. Chang,
M. J. Charles,
C. H. Cheng,
H. -Y. Cheng,
R. Chistov,
P. Colangelo,
J. P. Coleman,
A. Drutskoy
, et al. (2009 additional authors not shown)
Abstract:
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary…
▽ More
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C.
Please note that version 3 on the archive is the auxiliary version of the Physics of the B Factories book. This uses the notation alpha, beta, gamma for the angles of the Unitarity Triangle. The nominal version uses the notation phi_1, phi_2 and phi_3. Please cite this work as Eur. Phys. J. C74 (2014) 3026.
△ Less
Submitted 31 October, 2015; v1 submitted 24 June, 2014;
originally announced June 2014.
-
Silicon Avalanche Pixel Sensor for High Precision Tracking
Authors:
N. D'Ascenzo,
P. S. Marrocchesi,
C. S. Moon,
F. Morsani,
L. Ratti,
V. Saveliev,
A. Savoy Navarro,
Q. Xie
Abstract:
The development of an innovative position sensitive pixelated sensor to detect and measure with high precision the coordinates of the ionizing particles is proposed. The silicon avalanche pixel sensors (APiX) is based on the vertical integration of avalanche pixels connected in pairs and operated in coincidence in fully digital mode and with the processing electronics embedded on the chip. The APi…
▽ More
The development of an innovative position sensitive pixelated sensor to detect and measure with high precision the coordinates of the ionizing particles is proposed. The silicon avalanche pixel sensors (APiX) is based on the vertical integration of avalanche pixels connected in pairs and operated in coincidence in fully digital mode and with the processing electronics embedded on the chip. The APiX sensor addresses the need to minimize the material budget and related multiple scattering effects in tracking systems requiring a high spatial resolution in the presence of a large occupancy. The expected operation of the new sensor features: low noise, low power consumption and suitable radiation tolerance. The APiX device provides on-chip digital information on the position of the coordinate of the impinging charged particle and can be seen as the building block of a modular system of pixelated arrays, implementing a sparsified readout. The technological challenges are the 3D integration of the device under CMOS processes and integration of processing electronics.
△ Less
Submitted 30 November, 2013;
originally announced December 2013.
-
The MEG detector for $μ+\to e+γ$ decay search
Authors:
J. Adam,
X. Bai,
A. M. Baldini,
E. Baracchini,
C. Bemporad,
G. Boca,
P. W. Cattaneo,
G. Cavoto,
F. Cei,
C. Cerri,
M. Corbo,
N. Curalli,
A. De Bari,
M. De Gerone,
L. Del Frate,
S. Doke,
S. Dussoni,
J. Egger,
K. Fratini,
Y. Fujii,
L. Galli,
S. Galeotti,
G. Gallucci,
F. Gatti,
B. Golden
, et al. (51 additional authors not shown)
Abstract:
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and…
▽ More
The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.
△ Less
Submitted 10 April, 2013; v1 submitted 10 March, 2013;
originally announced March 2013.
-
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Authors:
P. S. Marrocchesi,
H. S. Ahn,
M. G. Bagliesi,
A. Basti,
G. Bigongiari,
A. Castellina,
M. A. Ciocci,
A. Di Virgilio,
T. Lomtatze,
O. Ganel,
K. C. Kim,
M. H. Lee,
F. Ligabue,
L. Lutz,
P. Maestro,
A. Malinine,
M. Meucci,
V. Millucci,
F. Morsani,
E. S. Seo,
R. Sina,
J. Wu,
J. Wu,
Y. S. Yoon,
R. Zei
, et al. (1 additional authors not shown)
Abstract:
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at…
▽ More
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
△ Less
Submitted 15 June, 2018; v1 submitted 24 March, 2010;
originally announced March 2010.
-
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Authors:
P. S. Marrocchesi,
H. S. Ahn,
M. G. Bagliesi,
A. Basti,
G. Bigongiari,
A. Castellina,
M. A. Ciocci,
A. Di Virgilio,
T. Lomtatze,
O. Ganel,
K. C. Kim,
M. H. Lee,
F. Ligabue,
L. Lutz,
P. Maestro,
A. Malinine,
M. Meucci,
V. Millucci,
F. Morsani,
E. S. Seo,
R. Sina,
J. Wu,
Y. S. Yoon,
R. Zei,
S. -Y. Zinn
Abstract:
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams…
▽ More
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
△ Less
Submitted 24 July, 2005;
originally announced July 2005.
-
The CDF-II Online Silicon Vertex Tracker
Authors:
A. Bardi,
A. Belloni,
R. Carosi,
A. Cerri,
G. Chlachidze,
M. Dell'Orso,
S. Donati,
S. Galeotti,
P. Giannetti,
V. Glagolev,
E. Meschi,
F. Morsani,
D. Passuello,
G. Punzi,
L. Ristori,
A. Semenov,
F. Spinella,
A. Barchiesi,
M. Rescigno,
S. Sarkar,
L. Zanello,
M. Bari,
S. Belforte,
A. M. Zanetti,
I. Fiori
, et al. (14 additional authors not shown)
Abstract:
The Online Silicon Vertex Tracker is the new CDF-II level 2 trigger processor designed to reconstruct 2-D tracks within the Silicon Vertex Detector with high speed and accuracy. By performing a precise measurement of impact parameters the SVT allows tagging online B events which typically show displaced secondary vertices. Physics simulations show that this will greatly enhance the CDF-II B-phys…
▽ More
The Online Silicon Vertex Tracker is the new CDF-II level 2 trigger processor designed to reconstruct 2-D tracks within the Silicon Vertex Detector with high speed and accuracy. By performing a precise measurement of impact parameters the SVT allows tagging online B events which typically show displaced secondary vertices. Physics simulations show that this will greatly enhance the CDF-II B-physics capability. The SVT has been fully assembled and operational since the beginning of Tevatron RunII in April 2001. In this paper we briefly review the SVT design and physics motivation and then describe its performance during the early phase (April-October 2001) of run II.
△ Less
Submitted 10 December, 2001;
originally announced December 2001.