Image Reconstruction in Cone Beam Computed Tomography Using Controlled Gradient Sparsity
Authors:
Alexander Meaney,
Mikael A. K. Brix,
Miika T. Nieminen,
Samuli Siltanen
Abstract:
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray tomography (CBCT) has been limited so far, mainly due to heavy computational loads at clinically relevant 3D resolutions and the difficulty in choosing the regularizati…
▽ More
Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray tomography (CBCT) has been limited so far, mainly due to heavy computational loads at clinically relevant 3D resolutions and the difficulty in choosing the regularization parameter. Here an efficient minimization algorithm is presented, combined with a dynamic parameter adjustment based on control theory. The result is a fully automatic 3D reconstruction method running in clinically acceptable time. The input on top of projection data and system geometry is desired degree of sparsity of the reconstruction. This can be determined from an atlas of CT scans, or alternatively used as an easily adjustable parameter with straightforward interpretation.
△ Less
Submitted 10 December, 2024;
originally announced December 2024.
-
Dynamic computerized tomography using inexact models and motion estimation
Authors:
Gesa Sarnighausen,
Anne Wald,
Alexander Meaney
Abstract:
Reconstructing a dynamic object with affine motion in computerized tomography (CT) leads to motion artifacts if the motion is not taken into account. In most cases, the actual motion is neither known nor can be determined easily. As a consequence, the respective model that describes CT is incomplete. The iterative RESESOP-Kaczmarz method can - under certain conditions and by exploiting the modelin…
▽ More
Reconstructing a dynamic object with affine motion in computerized tomography (CT) leads to motion artifacts if the motion is not taken into account. In most cases, the actual motion is neither known nor can be determined easily. As a consequence, the respective model that describes CT is incomplete. The iterative RESESOP-Kaczmarz method can - under certain conditions and by exploiting the modeling error - reconstruct dynamic objects at different time points even if the exact motion is unknown. However, the method is very time-consuming. To speed the reconstruction process up and obtain better results, we combine the following three steps: 1. RESESOP-Kacmarz with only a few iterations is implemented to reconstruct the object at different time points. 2. The motion is estimated via landmark detection, e.g. using deep learning. 3. The estimated motion is integrated into the reconstruction process, allowing the use of dynamic filtered backprojection. We give a short review of all methods involved and present numerical results as a proof of principle.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
Don't Take it Personally: Analyzing Gender and Age Differences in Ratings of Online Humor
Authors:
J. A. Meaney,
Steven R. Wilson,
Luis Chiruzzo,
Walid Magdy
Abstract:
Computational humor detection systems rarely model the subjectivity of humor responses, or consider alternative reactions to humor - namely offense. We analyzed a large dataset of humor and offense ratings by male and female annotators of different age groups. We find that women link these two concepts more strongly than men, and they tend to give lower humor ratings and higher offense scores. We…
▽ More
Computational humor detection systems rarely model the subjectivity of humor responses, or consider alternative reactions to humor - namely offense. We analyzed a large dataset of humor and offense ratings by male and female annotators of different age groups. We find that women link these two concepts more strongly than men, and they tend to give lower humor ratings and higher offense scores. We also find that the correlation between humor and offense increases with age. Although there were no gender or age differences in humor detection, women and older annotators signalled that they did not understand joke texts more often than men. We discuss implications for computational humor detection and downstream tasks.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Synergistic Multi-spectral CT Reconstruction with Directional Total Variation
Authors:
Evelyn Cueva,
Alexander Meaney,
Samuli Siltanen,
Matthias J. Ehrhardt
Abstract:
This work considers synergistic multi-spectral CT reconstruction where information from all available energy channels is combined to improve the reconstruction of each individual channel, we propose to fuse this available data (represented by a single sinogram) to obtain a polyenergetic image which keeps structural information shared by the energy channels with increased signal-to-noise-ratio. Thi…
▽ More
This work considers synergistic multi-spectral CT reconstruction where information from all available energy channels is combined to improve the reconstruction of each individual channel, we propose to fuse this available data (represented by a single sinogram) to obtain a polyenergetic image which keeps structural information shared by the energy channels with increased signal-to-noise-ratio. This new image is used as prior information during a channel-by-channel minimization process through the directional total variation. We analyze the use of directional total variation within variational regularization and iterative regularization. Our numerical results on simulated and experimental data show improvements in terms of image quality and in computational speed.
△ Less
Submitted 22 April, 2021; v1 submitted 5 January, 2021;
originally announced January 2021.
-
Gel phantom data for dynamic X-ray tomography
Authors:
Tommi Heikkilä,
Hanna Help,
Alexander Meaney
Abstract:
This is the documentation for dynamic X-ray tomography measurements of a gel phantom diffused with potassium iodide contrast agent. The measured data and additional materials are available at http://www.fips.fi/dataset.php and Zenodo (DOI:10.5281/zenodo.7876521) for open use by the scientific community, as long as the data and this documentation at arXiv are appropriately referenced.
The files c…
▽ More
This is the documentation for dynamic X-ray tomography measurements of a gel phantom diffused with potassium iodide contrast agent. The measured data and additional materials are available at http://www.fips.fi/dataset.php and Zenodo (DOI:10.5281/zenodo.7876521) for open use by the scientific community, as long as the data and this documentation at arXiv are appropriately referenced.
The files contain: (1) 17 consecutive measurements of the gel phantom organized into sinograms at two different resolutions (binning levels) and some additional metadata which can be used to create matrix-free forward operators and filtered back-projection reconstructions; (2) the first measurement using a greater number of projections, and an additional measurement of an 18th time step using very dense angular sampling, for example to be used for reference reconstructions; (3) short example codes to showcase how the data could be used to test and validate reconstruction algorithms.
△ Less
Submitted 28 April, 2023; v1 submitted 5 March, 2020;
originally announced March 2020.
-
Joint Reconstruction in Low Dose Multi-Energy CT
Authors:
Jussi Toivanen,
Alexander Meaney,
Samuli Siltanen,
Ville Kolehmainen
Abstract:
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction…
▽ More
Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost of a higher radiation dose. A straightforward way to lower the dose is to reduce the number of projections per energy, but this makes tomographic reconstruction more ill-posed. In this paper, we propose how this problem can be overcome with a combination of a regularization method that promotes structural similarity between images at different energies and a suitably selected low-dose data acquisition protocol using non-overlapping projections. The performance of various joint regularization models is assessed with both simulated and experimental data, using the novel low-dose data acquisition protocol. Three of the models are well-established, namely the joint total variation, the linear parallel level sets and the spectral smoothness promoting regularization models. Furthermore, one new joint regularization model is introduced for multi-energy CT: a regularization based on the structure function from the structural similarity index. The findings show that joint regularization outperforms individual channel-by-channel reconstruction. Furthermore, the proposed combination of joint reconstruction and non-overlapping projection geometry enables significant reduction of radiation dose.
△ Less
Submitted 13 February, 2020; v1 submitted 11 April, 2019;
originally announced April 2019.
-
Tomographic X-ray data of 3D cross phantom
Authors:
Salla Latva-Äijö,
Alexander Meaney,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of cross phantom made available at this https URL The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram with 16 or 30 time frames (depending on theresolution) of 2D slices of the phantom and (2) the corresponding static and…
▽ More
This is the documentation of the tomographic X-ray data of cross phantom made available at this https URL The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram with 16 or 30 time frames (depending on theresolution) of 2D slices of the phantom and (2) the corresponding static and dynamic measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 1 September, 2018;
originally announced September 2018.
-
Tomographic X-ray data of 3D emoji
Authors:
Alexander Meaney,
Zenith Purisha,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram of a single 2D slice of 33 emoji faces (contains 15 different emoji faces) made by sma…
▽ More
This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram of a single 2D slice of 33 emoji faces (contains 15 different emoji faces) made by small squared ceramic stones and (2) the corresponding static and dynamic measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 60-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 23 February, 2018;
originally announced February 2018.
-
Tomographic X-ray data of carved cheese
Authors:
Tatiana A. Bubba,
Markus Juvonen,
Jonatan Lehtonen,
Maximilian März,
Alexander Meaney,
Zenith Purisha,
Samuli Siltanen
Abstract:
This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/. The data set consists of (1) the X-ray sinogram of a single 2D slice of the cheese slice with three different resolutions and (2) the correspond…
▽ More
This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in https://arxiv.boxedpaper.com/. The data set consists of (1) the X-ray sinogram of a single 2D slice of the cheese slice with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.
△ Less
Submitted 14 June, 2017; v1 submitted 12 May, 2017;
originally announced May 2017.