-
Magneto-optical trapping in a near-surface borehole
Authors:
Jamie Vovrosh,
Katie Wilkinson,
Sam Hedges,
Kieran McGovern,
Farzad Hayati,
Christopher Carson,
Adam Selyem,
Jonathan Winch,
Ben Stray,
Luuk Earl,
Maxwell Hamerow,
Georgia Wilson,
Adam Seedat,
Sanaz Roshanmanesh,
Kai Bongs,
Michael Holynski
Abstract:
Borehole gravity sensing can be used in a number of applications to measure features around a well including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors based on atom interferometry have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, sign…
▽ More
Borehole gravity sensing can be used in a number of applications to measure features around a well including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors based on atom interferometry have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of ($60\pm0.1$) mm at its widest point and a length of ($890\pm5$) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate an in-borehole gravity surveys are performed. During the survey the system generated on average clouds of (3.0 $\pm 0.1) \times 10^{5}$ $^{87}$Rb atoms with the standard deviation in atom number across the survey observed to be as low as $9 \times 10^{4}$.
△ Less
Submitted 21 November, 2022;
originally announced November 2022.
-
Scale Reliant Inference
Authors:
Michelle Pistner Nixon,
Kyle C. McGovern,
Jeffrey Letourneau,
Lawrence A. David,
Nicole A. Lazar,
Sayan Mukherjee,
Justin D. Silverman
Abstract:
Many scientific fields, including human gut microbiome science, collect multivariate count data where the sum of the counts is unrelated to the scale of the underlying system being measured (e.g., total microbial load in a subject's colon). This disconnect complicates downstream analyses such as differential analysis in case-control studies. This article is motivated by a novel study of in vitro h…
▽ More
Many scientific fields, including human gut microbiome science, collect multivariate count data where the sum of the counts is unrelated to the scale of the underlying system being measured (e.g., total microbial load in a subject's colon). This disconnect complicates downstream analyses such as differential analysis in case-control studies. This article is motivated by a novel study of in vitro human gut microbiome models. Popular tools for analyzing these data led to dramatically elevated rates of both false positives and false negatives. To understand those failures, we provide a formal problem statement that frames these challenges of scale in terms of the classical theory of identifiability. We call this the problem of Scale Reliant Inference (SRI). We use this formulation to prove fundamental limits on SRI in terms of criteria such as consistency and type-I error control. We show that the failures of existing methods stem from a fundamental failure to properly quantify uncertainty in the system scale. We demonstrate that a particular type of Bayesian model called a Bayesian Partially Identified Model (PIMs) can correctly quantify uncertainty in SRI. We introduce Scale Simulation Random Variables (SSRVs) as a flexible and efficient approach to specifying and inferring Bayesian PIMs. In the context of both real and simulated data, we find SSRVs drastically decrease type-I and type-II error rates.
△ Less
Submitted 4 November, 2024; v1 submitted 10 January, 2022;
originally announced January 2022.
-
Bespoke magnetic field design for a magnetically shielded cold atom interferometer
Authors:
P. J. Hobson,
J. Vovrosh,
B. Stray,
M. Packer,
J. Winch,
N. Holmes,
F. Hayati,
K. McGovern,
R. Bowtell,
M. J. Brookes,
K. Bongs,
T. M. Fromhold,
M. Holynski
Abstract:
Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field environment. Typically, background magnetic fields are attenuated using high permeability magnetic shielding, with the cancelling of residual and introduction of quanti…
▽ More
Quantum sensors based on cold atoms are being developed which produce measurements of unprecedented accuracy. Due to shifts in atomic energy levels, quantum sensors often have stringent requirements on their internal magnetic field environment. Typically, background magnetic fields are attenuated using high permeability magnetic shielding, with the cancelling of residual and introduction of quantisation fields implemented with coils inside the shield. The high permeability shield, however, distorts all magnetic fields, including those generated inside the sensor. Here, we demonstrate a solution by designing multiple coils overlaid on a 3D-printed former to generate three uniform and three constant linear gradient magnetic fields inside the capped cylindrical magnetic shield of a cold atom interferometer. The fields are characterised in-situ and match their desired forms to high accuracy. For example, the uniform transverse field, $B_x$, deviates by less than $0.2$% over more than $40$% of the length of the shield. We also map the field directly using the cold atoms and investigate the potential of the coil system to reduce bias from the quadratic Zeeman effect. This coil design technology enables targeted field compensation over large spatial volumes and has the potential to reduce systematic shifts and noise in numerous cold atom systems.
△ Less
Submitted 23 June, 2022; v1 submitted 9 October, 2021;
originally announced October 2021.