-
Mapping the path to Cryogenic Atom Probe Tomography Analysis of biomolecules
Authors:
Eric V. Woods,
Tim M. Schwarz,
Mahander P. Singh,
Shuo Zhang,
Se-Ho Kim,
Ayman A. El-Zoka,
Lothar Gremer,
Dieter Willbold,
Ingrid McCarroll,
B. Gault
Abstract:
The understanding of protein structure, folding, and interaction with other proteins remains one of the grand challenges of modern biology. Tremendous progress has been made thanks to X-ray- or electron-based techniques that have provided atomic configurations of proteins, and their solvation shell. These techniques though require a large number of similar molecules to provide an average view, and…
▽ More
The understanding of protein structure, folding, and interaction with other proteins remains one of the grand challenges of modern biology. Tremendous progress has been made thanks to X-ray- or electron-based techniques that have provided atomic configurations of proteins, and their solvation shell. These techniques though require a large number of similar molecules to provide an average view, and lack detailed compositional information that might play a major role in the biochemical activity of these macromolecules. Based on its intrinsic performance and recent impact in materials science, atom probe tomography (APT) has been touted as a potential novel tool to analyse biological materials, including proteins. However, analysis of biomolecules in their native, hydrated state by APT have not yet been routinely achieved, and the technique's true capabilities remain to be demonstrated. Here, we present and discuss systematic analyses of individual amino-acids in frozen aqueous solutions on two different nanoporous metal supports across a wide range of analysis conditions. Using a ratio of the molecular ions of water as a descriptor for the conditions of electrostatic field, we study the fragmentation and behavior of those amino acids. We discuss the importance sample support, specimen preparation route, acquisition conditions and data analysis, to pave the way towards establishing guidelines for cryo-APT analysis of biomolecules.
△ Less
Submitted 19 April, 2024;
originally announced April 2024.
-
Analysis of water ice in nanoporous copper needles using cryo atom probe tomography
Authors:
Levi Tegg,
Ingrid E. McCarroll,
Se-Ho Kim,
Renelle Dubosq,
Eric V. Woods,
Ayman A. El-Zoka,
Baptiste Gault,
Julie M. Cairney
Abstract:
The application of atom probe tomography (APT) to frozen liquids is limited by difficulties in specimen preparation. Here, we report on the use of nanoporous Cu needles as a physical framework to hold water ice for investigation using APT. Nanoporous Cu needles are prepared by the electropolishing and dealloying of Cu-Mn matchstick precursors. Cryogenic scanning electron microscopy and focused-ion…
▽ More
The application of atom probe tomography (APT) to frozen liquids is limited by difficulties in specimen preparation. Here, we report on the use of nanoporous Cu needles as a physical framework to hold water ice for investigation using APT. Nanoporous Cu needles are prepared by the electropolishing and dealloying of Cu-Mn matchstick precursors. Cryogenic scanning electron microscopy and focused-ion beam milling reveal a hierarchical, dendritic, highly-wettable microstructure. The atom probe mass spectrum is dominated by peaks of Cu+ and H(H2O)n+ up to n <= 3, and the reconstructed volume shows the protrusion of a Cu ligament into an ice-filled pore. The continuous Cu ligament network electrically connects the apex to the cryostage, leading to enhanced electric field at the apex and increased cooling, both of which simplify the mass spectrum compared to previous reports.
△ Less
Submitted 7 February, 2024;
originally announced February 2024.
-
In-situ metallic coating of atom probe specimen for enhanced yield, performance, and increased field-of-view
Authors:
Tim M. Schwarz,
Eric Woods,
Mahander P. Singh,
Chanwon Jung,
Leonardo S. Aota,
Kyuseon Jang,
Mathias Krämer,
Se-Ho Kim,
Ingrid McCarroll,
Baptiste Gault
Abstract:
Atom probe tomography requires needle-shaped specimens with a diameter typically below 100 nm, making them both very fragile and reactive, and defects (notches at grain boundaries or precipitates) are known to affect the yield and data quality. The use of a conformal coating directly on the sharpened specimen has been proposed to increase yield and reduce background. However, to date, these coatin…
▽ More
Atom probe tomography requires needle-shaped specimens with a diameter typically below 100 nm, making them both very fragile and reactive, and defects (notches at grain boundaries or precipitates) are known to affect the yield and data quality. The use of a conformal coating directly on the sharpened specimen has been proposed to increase yield and reduce background. However, to date, these coatings have been applied ex-situ and mostly are not uniformly. Here, we report on the controlled focused ion beam in-situ deposition of a thin metal film on specimens immediately after specimen preparation. Different metallic targets e.g. Cr were attached to a micromanipulator via a conventional lift-out method and sputtered using the Ga or Xe ions. We showcase the many advantages of coating specimens from metallic to non-metallic materials. We have identified an increase in data quality and yield, an improvement of the mass resolution, as well as an increase in the effective field-of-view enabling visualization of the entire original specimen, including the complete surface oxide layer. The ease of implementation of the approach makes it very attractive for generalizing its use across a very wide range of atom probe analyses.
△ Less
Submitted 17 January, 2024; v1 submitted 14 September, 2023;
originally announced September 2023.
-
Chemical and structural characterization of the native oxide scale on a Mg-based alloy
Authors:
Deborah Neuß,
Ingrid E. McCarroll,
Siyuan Zhang,
Eric Woods,
Wassilios J. Delis,
Leandro Tanure,
Hauke Springer,
Stefanie Sandlöbes,
Jing Yang,
Mira Todorova,
Daniela Zander,
Christina Scheu,
Jochen M. Schneider,
Marcus Hans
Abstract:
In this study, the structure and composition of the native oxide forming on the basal plane (0001) of Mg-2Al-0.1Ca is investigated by a correlative approach, combining scanning transmission electron microscopy (STEM) and atom probe tomography (APT). Atom probe specimens were prepared conventionally in a Ga focused ion beam (FIB) as well as a Xe plasma FIB in a cryogenic setup and subsequently clea…
▽ More
In this study, the structure and composition of the native oxide forming on the basal plane (0001) of Mg-2Al-0.1Ca is investigated by a correlative approach, combining scanning transmission electron microscopy (STEM) and atom probe tomography (APT). Atom probe specimens were prepared conventionally in a Ga focused ion beam (FIB) as well as a Xe plasma FIB in a cryogenic setup and subsequently cleaned in the atom probe to remove surface contamination before oxidation. While thermal energy input from the laser and longer atmospheric exposure time increased the measured hydrogen content in the specimen's apex region, cryo preparation revealed, that the hydrogen uptake in magnesium is independent of the employment of conventional or cryogenic FIB preparation. TEM measurements demonstrated the growth of a (111) MgO oxide layer with 3-4 nm thickness on the basal (0001) plane of the Mg atom probe specimen. APT data further revealed the formation of an aluminum-rich region between bulk Mg and the native oxide. The aluminum enrichment of up to ~20 at.% at the interface is consistent with an inward growth of the oxide scale.
△ Less
Submitted 2 June, 2023; v1 submitted 14 March, 2023;
originally announced March 2023.