-
Extraction of $|V_{cb}|$ from two-body hadronic B decays
Authors:
Noriaki Kitazawa,
Kyo-suke Masukawa,
Yuki Sakai
Abstract:
We propose a method of extracting the Cabibbo-Kobayashi-Maskawa matrix element $|V_{cb}|$ from two-body hadronic decay processes of $B\to DK$ with precisely determined form factors of $B$ meson semi-leptonic decays. The amplitude $\mathcal{M}(\bar{B}^0 \to D^+ K^-)$ which does not include the effect of hadronic final state interactions can be theoretically evaluated by using factorization and form…
▽ More
We propose a method of extracting the Cabibbo-Kobayashi-Maskawa matrix element $|V_{cb}|$ from two-body hadronic decay processes of $B\to DK$ with precisely determined form factors of $B$ meson semi-leptonic decays. The amplitude $\mathcal{M}(\bar{B}^0 \to D^+ K^-)$ which does not include the effect of hadronic final state interactions can be theoretically evaluated by using factorization and form factors of semi-leptonic B decays. We can obtain all the amplitudes in an isospin relation $\mathcal{A}(B^-\to D^0K^-) =\mathcal{A}(\bar{B}^0\to D^+K^{-})+\mathcal{A}(\bar{B}^0\to D^{0}\bar{K}^0)$ including the effect of hadronic final state interactions as well as $|V_{cb}|$ using the experimental data of branching fractions of these three processes with a truncation of the states which contribute to the hadronic final state interactions. The extracted value of $|V_{cb}|$ is $(37\pm 6)\times 10^{-3}$. The decay processes of $B\to DK^{*}$ and $B\to D^{*}K$ can also be used in the same way and the extracted values of $|V_{cb}|$ are $(41\pm 7)\times 10^{-3}$ and $(42\pm 9)\times 10^{-3}$, respectively. This method becomes possible by virtue of recent precise determinations of the form factors of semi-leptonic B decays. The uncertainties of $|V_{cb}|$ by this method are expected to be reduced by the results of future B-factory experiments and lattice calculations.
△ Less
Submitted 12 December, 2018; v1 submitted 15 February, 2018;
originally announced February 2018.
-
In Orbit Timing Calibration of the Hard X-Ray Detector on Board Suzaku
Authors:
Yukikatsu Terada,
Teruaki Enoto,
Ryouhei Miyawaki,
Yoshitaka Ishisaki,
Tadayasu Dotani,
Ken Ebisawa,
Masanobu Ozaki,
Yoshihiro Ueda,
Lucien Kuiper,
Manabu Endo,
Yasushi Fukazawa,
Tsuneyoshi Kamae,
Madoka Kawaharada,
Motohide Kokubun,
Yoshikatsu Kuroda,
Kazuo Makishima,
Kazunori Masukawa,
Tsunefumi Mizuno,
Toshio Murakami,
Kazuhiro Nakazawa,
Atsushi Nakajima,
Masaharu Nomach,
Naoki Shibayama,
Tadayuki Takahashi,
Hiromitsu Takahashi
, et al. (6 additional authors not shown)
Abstract:
The hard X-ray detector (HXD) on board the X-ray satellite Suzaku is designed to have a good timing capability with a 61 $μ$s time resolution. In addition to detailed descriptions of the HXD timing system, results of in-orbit timing calibration and performance of the HXD are summarized. The relative accuracy of time measurements of the HXD event was confirmed to have an accuracy of…
▽ More
The hard X-ray detector (HXD) on board the X-ray satellite Suzaku is designed to have a good timing capability with a 61 $μ$s time resolution. In addition to detailed descriptions of the HXD timing system, results of in-orbit timing calibration and performance of the HXD are summarized. The relative accuracy of time measurements of the HXD event was confirmed to have an accuracy of $1.9\times 10^{-9}$ s s$^{-1}$ per day, and the absolute timing was confirmed to be accurate to 360 $μ$s or better. The results were achieved mainly through observations of the Crab pulsar, including simultaneous ones with RXTE, INTEGRAL, and Swift.
△ Less
Submitted 16 November, 2007;
originally announced November 2007.
-
Hard X-ray Detector (HXD) on Board Suzaku
Authors:
T. Takahashi,
K. Abe,
M. Endo,
Y. Endo,
Y. Ezoe,
Y. Fukazawa,
M. Hamaya,
S. Hirakuri,
S. Hong,
M. Horii,
H. Inoue,
N. Isobe,
T. Itoh,
N. Iyomoto,
T. Kamae,
D. Kasama,
J. Kataoka,
H. Kato,
M. Kawaharada,
N. Kawano,
K. Kawashima,
S. Kawasoe,
T. Kishishita,
T. Kitaguchi,
Y. Kobayashi
, et al. (44 additional authors not shown)
Abstract:
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the…
▽ More
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.