AC-LGADs Fermilab Front-End Electronics Characterization
Authors:
René Ríos,
Esteban Felipe Molina Cardenas,
Cristian Peña,
Orlando Soto,
William Brooks,
Artur Apresyan,
Sergey Los,
Claudio San Martín
Abstract:
We characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the signal resolution is influenced by the front-end electroni…
▽ More
We characterized the front-end electronics used to process high-frequency signals from low-gain avalanche diodes (LGADs) at the Fermilab Test Beam Facility. LGADs are silicon detectors employed for charged particle tracking, offering exceptional spatial and temporal resolution. The purpose of this characterization was to understand how the signal resolution is influenced by the front-end electronics. To achieve this, we developed a setup capable of generating input signals with varying amplitudes. The output results demonstrated that signal processing by the front-end electronics plays a crucial role in enhancing time resolution. We showed that the time resolution achieved by the FEE board is better than $2\: ps$.
△ Less
Submitted 15 April, 2025; v1 submitted 11 April, 2025;
originally announced April 2025.
-
High Energy Particle Detection with Large Area Superconducting Microwire Array
Authors:
Cristián Peña,
Christina Wang,
Si Xie,
Adolf Bornheim,
Matías Barría,
Claudio San Martín,
Valentina Vega,
Artur Apresyan,
Emanuel Knehr,
Boris Korzh,
Jamie Luskin,
Lautaro Narváez,
Sahil Patel,
Matthew Shaw,
Maria Spiropulu
Abstract:
We present the first detailed study of an 8-channel $2\times2$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV proton beam and 8 GeV electron and pion beam at the Fermilab Test Beam Facility. The SMSPD detection efficiency was measured for the first time for protons, electrons, and pions, enabled by the use of a silicon tracking telescope that provide…
▽ More
We present the first detailed study of an 8-channel $2\times2$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV proton beam and 8 GeV electron and pion beam at the Fermilab Test Beam Facility. The SMSPD detection efficiency was measured for the first time for protons, electrons, and pions, enabled by the use of a silicon tracking telescope that provided precise spatial resolution of 30 $μ$m for 120 GeV protons and 130 $μ$m for 8 GeV electrons and pions. The result demonstrated consistent detection efficiency across pixels and at different bias currents. Time resolution of 1.15 ns was measured for the first time for SMSPD with proton, electron, and pions, enabled by the use of an MCP-PMT which provided a ps-level reference time stamp. The results presented is the first step towards developing SMSPD array systems optimized for high energy particle detection and identification for future accelerator-based experiments.
△ Less
Submitted 6 March, 2025; v1 submitted 30 September, 2024;
originally announced October 2024.
-
Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam
Authors:
Irene Dutta,
Christopher Madrid,
Ryan Heller,
Shirsendu Nanda,
Danush Shekar,
Claudio San Martín,
Matías Barría,
Artur Apresyan,
Zhenyu Ye,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Alessandro Tricoli,
Aram Hayrapetyan,
Hakseong Lee,
Ohannes Kamer Köseyan,
Sergey Los,
Koji Nakamura,
Sayuka Kita,
Tomoka Imamura,
Cristían Peña,
Si Xie
Abstract:
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attaina…
▽ More
We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20 $μ$m-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20 $μ$m-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50 $μ$m-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n$^{+}$ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.
△ Less
Submitted 20 January, 2025; v1 submitted 13 July, 2024;
originally announced July 2024.
-
First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam
Authors:
Christopher Madrid,
Ryan Heller,
Claudio San Martín,
Shirsendu Nanda,
Artur Apresyan,
William K. Brooks,
Wei Chen,
Gabriele Giacomini,
Ohannes Kamer Köseyan,
Sergey Los,
Cristián Peña,
René Rios,
Alessandro Tricoli,
Si Xie,
Zhenyu Ye
Abstract:
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-bas…
▽ More
We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 micron and 32 ps resolutions from strips of 1 cm length and 500 micron pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.
△ Less
Submitted 20 April, 2023; v1 submitted 17 November, 2022;
originally announced November 2022.
-
Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam
Authors:
Ryan Heller,
Christopher Madrid,
Artur Apresyan,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Ikumi Goya,
Kazuhiko Hara,
Sayuka Kita,
Sergey Los,
Adam Molnar,
Koji Nakamura,
Cristián Peña,
Claudio San Martín,
Alessandro Tricoli,
Tatsuki Ueda,
Si Xie
Abstract:
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows deta…
▽ More
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6-10 micron position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.
△ Less
Submitted 29 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Performance tests of boron-coated straw detectors with thermal and cold neutron beams
Authors:
Georg Ehlers,
Athanasios Athanasiades,
Liang Sun,
Christopher S. Martin,
Murari Regmi,
Jeffrey L. Lacy
Abstract:
Prototypes of newly developed boron-coated straw (BCS) detectors have been tested in the thermal and cold neutron energy ranges. Their neutron detection performance has been benchmarked against the industry standard (detector tubes filled with 3He gas). The tests show that the BCS straws perform near their theoretical limit regarding the detection efficiency, which is adequate for scientific instr…
▽ More
Prototypes of newly developed boron-coated straw (BCS) detectors have been tested in the thermal and cold neutron energy ranges. Their neutron detection performance has been benchmarked against the industry standard (detector tubes filled with 3He gas). The tests show that the BCS straws perform near their theoretical limit regarding the detection efficiency, which is adequate for scientific instruments in the cold neutron energy range. The BCS detectors perform on par with 3He tubes in terms of signal to noise and timing resolution, and superior regarding longitudinal spatial resolution.
△ Less
Submitted 5 August, 2019;
originally announced August 2019.