-
Irradiation Study Using QA Test Pieces of ATLAS18 ITk Strip Sensors with 80MeV Protons
Authors:
Y. Huang,
H. Li,
B. Crick,
V. Cindro,
A. Chisholm,
M. Cai,
H. Deng,
V. Fadeyev,
S. Hirose,
H. Jing,
B. Jiang,
P. Liu,
Y. Liu,
W. Lu,
H. Liu,
I. Mandić,
R. S. Orr,
X. Shi,
Z. Tan,
Y. Unno,
M. Ullan,
S. Wang,
Z. Xu
Abstract:
The ATLAS experiment is planning a complete replacement of its inner detector(ID) with a new all-silicon inner tracker (ITk) for the ATLAS Inner Tracker Phase-2 upgrade. The ATLAS18 silicon strip sensors are designed to operate up to the integrated luminosity of 4000 fb$^{-1}$, which corresponds to the maximum fluence of $1.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ (including safety f…
▽ More
The ATLAS experiment is planning a complete replacement of its inner detector(ID) with a new all-silicon inner tracker (ITk) for the ATLAS Inner Tracker Phase-2 upgrade. The ATLAS18 silicon strip sensors are designed to operate up to the integrated luminosity of 4000 fb$^{-1}$, which corresponds to the maximum fluence of $1.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ (including safety factor). To enhance the quality assurance (QA) program to monitor the key properties of the sensors, the strip sensor community is considering to include China Spallation Neutron Source (CSNS) as a proton irradiation site and Institute of High Energy Physics (IHEP) as a QA test site. A total of 18 ATLAS18 ITk QA test pieces were irradiated with $6.0 \times 10^{14}$, $1.6 \times 10^{15}$, and $2.6 \times 10^{15} \, \text n_{\text{eq}} / \text{cm}^2$ protons at CSNS, and measured at IHEP, including IV (leakage current-voltage), CV (capacitance-voltage) and CCE (charge collection efficiency) measurements. The upgraded irradiation setup at CSNS and measurement setup at IHEP are shown in this paper. Irradiated samples were exchanged between IHEP, Ljubljana and Birmingham to cross-check CCE measurements.
△ Less
Submitted 25 March, 2025;
originally announced March 2025.
-
Performance of neutron and proton irradiated AC-LGAD sensors
Authors:
G. Stage,
A. Borjigin,
J. Ding,
M. Davis,
S. Beringer,
M. Gignac,
F. McKinney-Martinez,
S. M. Mazza,
A. Molnar,
J. Ott,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden,
T. Shin,
M. Wilder,
G. Kramberger,
I. Mandic,
S. Seidel,
J. Si,
R. Novotny
Abstract:
Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EI…
▽ More
Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment.
△ Less
Submitted 24 March, 2025; v1 submitted 20 March, 2025;
originally announced March 2025.
-
Evolution of the electrical characteristics of the ATLAS18 ITk strip sensors with HL-LHC radiation exposure range
Authors:
J. Fernandez-Tejero,
E. Bach,
V. Cindro,
V. Fadeyev,
P. Federicova,
C. Fleta,
S. Hirose,
J. Kroll,
I. Mandic,
K. Maeyama,
M. Mikestikova,
L. Poley,
B. Stelzer,
P. Tuma,
M. Ullan,
Y. Unno
Abstract:
The objective of the study is to evaluate the evolution of the performance of the new ATLAS Inner-Tracker (ITk) strip sensors as a function of radiation exposure, to ensure the proper operation of the upgraded detector during the lifetime of the High-Luminosity Large Hadron Collider (HL-LHC). Full-size ATLAS ITk Barrel Short-Strip (SS) sensors with final layout design, ATLAS18SS, have been irradia…
▽ More
The objective of the study is to evaluate the evolution of the performance of the new ATLAS Inner-Tracker (ITk) strip sensors as a function of radiation exposure, to ensure the proper operation of the upgraded detector during the lifetime of the High-Luminosity Large Hadron Collider (HL-LHC). Full-size ATLAS ITk Barrel Short-Strip (SS) sensors with final layout design, ATLAS18SS, have been irradiated with neutrons and gammas, to confirm the results obtained with prototypes and miniature sensors during the development phase. The irradiations cover a wide range of fluences and doses that ITk will experience, going from 1e13 neq/cm2 and 0.49 Mrad, to 1.6e15 neq/cm2 and 80 Mrad. The split irradiation enables a proper combination of fluence and dose values of the HL-LHC, including a 1.5 safety factor. A complete electrical characterization of the key sensor parameters before and after irradiation is presented, studying the leakage current, bulk capacitance, single-strip and inter-strip characteristics. The results confirm the fulfilment of the ATLAS specifications throughout the whole experiment. The study of a wide range of fluences and doses also allows to obtain detailed results, such as the frequency dependence of the bulk capacitance measurements for highly irradiated sensors, or the evolution of the punch-through protection and inter-strip resistance with radiation.
△ Less
Submitted 3 October, 2024;
originally announced October 2024.
-
Measurements of time resolution of the RD50-MPW2 DMAPS prototype using TCT and $^{90}\mathrm{Sr}$
Authors:
J. Debevc,
M. Franks,
B. Hiti,
U. Kraemer,
G. Kramberger,
I. Mandić,
R. Marco-Hernández,
D. J. L. Nobels,
S. Powell,
J. Sonneveld,
H. Steininger,
C. Tsolanta,
E. Vilella,
C. Zhang
Abstract:
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage…
▽ More
Results in this paper present an in-depth study of time resolution for active pixels of the RD50-MPW2 prototype CMOS particle detector. Measurement techniques employed include Backside- and Edge-TCT configurations, in addition to electrons from a $^{90}\mathrm{Sr}$ source. A sample irradiated to $5\cdot 10^{14}\,\mathrm{n}_\mathrm{eq}/\mathrm{cm}^2$ was used to study the effect of radiation damage. Timing performance was evaluated for the entire pixel matrix and with positional sensitivity within individual pixels as a function of the deposited charge. Time resolution obtained with TCT is seen to be uniform throughout the pixel's central region with approx. $220\,\mathrm{ps}$ at $12\,\mathrm{ke}^-$ of deposited charge, degrading at the edges and lower values of deposited charge. $^{90}\mathrm{Sr}$ measurements show a slightly worse time resolution as a result of delayed events coming from the peripheral areas of the pixel.
△ Less
Submitted 25 January, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
Gain Recovery in Heavily Irradiated Low Gain Avalanche Detectors by High Temperature Annealing
Authors:
I. Mandić,
V. Cindro,
A. Gorišek,
B. Hiti,
A. Howard,
Ž. Kljun,
G. Kramberger,
M. Maček Kržmanc,
M. Mikuž,
B. Novak
Abstract:
Studies of annealing at temperatures up to 450$^\circ$C with LGADs irradiated with neutrons are described. It was found that the performance of LGADs irradiated with 1.5e15 n/cm$^2$ was already improved at 5 minutes of annealing at 250$^\circ$C. Isochronal annealing for 30 minutes in 50$^\circ$C steps between 300$^\circ$C and 450$^\circ$C showed that the largest beneficial effect of annealing is a…
▽ More
Studies of annealing at temperatures up to 450$^\circ$C with LGADs irradiated with neutrons are described. It was found that the performance of LGADs irradiated with 1.5e15 n/cm$^2$ was already improved at 5 minutes of annealing at 250$^\circ$C. Isochronal annealing for 30 minutes in 50$^\circ$C steps between 300$^\circ$C and 450$^\circ$C showed that the largest beneficial effect of annealing is at around 350$^\circ$C. Another set of devices was annealed for 60 minutes at 350$^\circ$C and this annealing significantly increased V$_{\mathrm{gl}}$. The effect is equivalent to reducing the effective acceptor removal constant by a factor of $\sim$ 4. Increase of V$_{\mathrm{gl}}$ is the consequence of increased effective space charge in the gain layer caused by formation of electrically active defects or re-activation of interstitial Boron atoms.
△ Less
Submitted 20 March, 2023; v1 submitted 25 January, 2023;
originally announced January 2023.
-
Tuning of gain layer doping concentration and Carbon implantation effect on deep gain layer
Authors:
S. M. Mazza,
C. Gee,
Y. Zhao,
R. Padilla,
E. Ryan,
N. Tournebise,
B. Darby,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
B. Schumm,
V. Cindro,
G. Kramberger,
I. Mandić,
M. Mikuž,
M. Zavrtanik,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
V. Sola,
A. Staiano,
M. Boscardin,
G. F. Della Betta,
F. Ficorella
, et al. (2 additional authors not shown)
Abstract:
Next generation Low Gain Avalanche Diodes (LGAD) produced by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with ~1MeV neutrons at the JSI facility in Ljubljana. Sensors were irradiated to a maximum 1-MeV equivalent fluence of 2.5E15 Neq/cm2. The sensors analysed in this paper are an improvement after the lessons learned from previous FBK and…
▽ More
Next generation Low Gain Avalanche Diodes (LGAD) produced by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with ~1MeV neutrons at the JSI facility in Ljubljana. Sensors were irradiated to a maximum 1-MeV equivalent fluence of 2.5E15 Neq/cm2. The sensors analysed in this paper are an improvement after the lessons learned from previous FBK and HPK productions that were already reported in precedent papers. The gain layer of HPK sensors was fine-tuned to optimize the performance before and after irradiation. FBK sensors instead combined the benefit of Carbon infusion and deep gain layer to further the radiation hardness of the sensors and reduced the bulk thickness to enhance the timing resolution. The sensor performance was measured in charge collection studies using \b{eta}-particles from a 90Sr source and in capacitance-voltage scans (C-V) to determine the bias to deplete the gain layer. The collected charge and the timing resolution were measured as a function of bias voltage at -30C. Finally a correlation is shown between the bias voltage to deplete the gain layer and the bias voltage needed to reach a certain amount of gain in the sensor. HPK sensors showed a better performance before irradiation while maintaining the radiation hardness of the previous production. FBK sensors showed exceptional radiation hardness allowing a collected charge up to 10 fC and a time resolution of 40 ps at the maximum fluence.
△ Less
Submitted 31 January, 2022; v1 submitted 21 January, 2022;
originally announced January 2022.
-
Study of neutron irradiation effects in Depleted CMOS detector structures
Authors:
I. Mandić,
V. Cindro,
J. Debevc,
A. Gorišek,
B. Hiti,
G. Kramberger,
P. Skomina,
M. Zavrtanik,
M. Mikuž,
E. Vilella,
C. Zhang,
S. Powell,
M. Franks,
R. Marco-Hernandez,
H. Steininger
Abstract:
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$Ω$cm are presented. Samples were irradiated with reactor neutrons up to a fluence of 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Depletion depth was measured with Edge-TCT. Effective space charg…
▽ More
In this paper results of Edge-TCT and I-V measurements with passive test structures made in LFoundry 150 nm HV-CMOS process on p-type substrates with different initial resistivities ranging from 0.5 to 3 k$Ω$cm are presented. Samples were irradiated with reactor neutrons up to a fluence of 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Depletion depth was measured with Edge-TCT. Effective space charge concentration $N_{\mathrm{eff}}$ was estimated from the dependence of depletion depth on bias voltage and studied as a function of neutron fluence. Dependence of $N_{\mathrm{eff}}$ on fluence changes with initial acceptor concentration in agreement with other measurements with p-type silicon. Long term accelerated annealing study of $N_{\mathrm{eff}}$ and detector current up to 1280 minutes at 60$^\circ$C was made. It was found that $N_{\mathrm{eff}}$ and current in reverse biased detector behaves as expected for irradiated silicon.
△ Less
Submitted 15 February, 2022; v1 submitted 20 December, 2021;
originally announced December 2021.
-
Characterisation of analogue front end and time walk in CMOS active pixel sensor
Authors:
B. Hiti,
V. Cindro,
A. Gorišek,
M. Franks,
R. Marco-Hernández,
G. Kramberger,
I. Mandić,
M. Mikuž,
S. Powell,
H. Steininger,
E. Vilella,
M. Zavrtanik,
C. Zhang
Abstract:
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2. Threshold, noise and calibration of the analogue front end were determined with external charge injection. A spatially sensitive measurement of collected charge a…
▽ More
In this work we investigated a method to determine time walk in an active silicon pixel sensor prototype using Edge-TCT with infrared laser charge injection. Samples were investigated before and after neutron irradiation to 5e14 neq/cm2. Threshold, noise and calibration of the analogue front end were determined with external charge injection. A spatially sensitive measurement of collected charge and time walk was carried out with Edge-TCT, showing a uniform charge collection and output delay in pixel centre. On pixel edges charge sharing was observed due to finite beam width resulting in smaller signals and larger output delay. Time walk below 25 ns was observed for charge above 2000 electrons at a threshold above the noise level. Time walk measurement with external charge injection yielded identical results.
△ Less
Submitted 23 November, 2021; v1 submitted 11 October, 2021;
originally announced October 2021.
-
Mapping the in-plane electric field inside irradiated diodes
Authors:
L. Poley,
A. J. Blue,
C. Buttar,
V. Cindro,
C. Darroch,
V. Fadeyev,
J. Fernandez-Tejero,
C. Fleta,
C. Helling,
C. Labitan,
I. Mandić,
S. N. Santpur,
D. Sperlich,
M. Ullán,
Y. Unno
Abstract:
A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of…
▽ More
A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of the Large Hadron Collider at CERN, which will significantly increase the rate of particle collisions and resulting particle tracks. During their operation in the ATLAS detector, sensors for the ITk strip tracker are expected to accumulate fluences up to 1.6 x 10^15 n_eq/cm^2 (including a safety factor of 1.5), which will significantly affect their performance. One characteristic of interest for highly irradiated sensors is the shape and homogeneity of the electric field inside its active area. For the results presented here, diodes with edge structures similar to full size ATLAS sensors were irradiated up to fluences comparable to those in the ATLAS ITk strip tracker and their electric fields mapped using a micro-focused X-ray beam (beam diameter 2x3 μm^2). This study shows the extension and shape of the electric field inside highly irradiated diodes over a range of applied bias voltages. Additionally, measurements of the outline of the depleted sensor areas allow a comparison of the measured leakage current for different fluences with expectations for the corresponding active areas.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
The ABC130 barrel module prototyping programme for the ATLAS strip tracker
Authors:
Luise Poley,
Craig Sawyer,
Sagar Addepalli,
Anthony Affolder,
Bruno Allongue,
Phil Allport,
Eric Anderssen,
Francis Anghinolfi,
Jean-François Arguin,
Jan-Hendrik Arling,
Olivier Arnaez,
Nedaa Alexandra Asbah,
Joe Ashby,
Eleni Myrto Asimakopoulou,
Naim Bora Atlay,
Ludwig Bartsch,
Matthew J. Basso,
James Beacham,
Scott L. Beaupré,
Graham Beck,
Carl Beichert,
Laura Bergsten,
Jose Bernabeu,
Prajita Bhattarai,
Ingo Bloch
, et al. (224 additional authors not shown)
Abstract:
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000…
▽ More
For the Phase-II Upgrade of the ATLAS Detector, its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100 % silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototyping programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-25) and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototyping program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.
△ Less
Submitted 7 September, 2020;
originally announced September 2020.
-
Measurements with silicon detectors at extreme neutron fluences
Authors:
I. Mandić,
V. Cindro,
A. Gorišek,
B. Hiti,
G. Kramberger,
M. Mikuž,
M. Zavrtanik,
P. Skomina,
S. Hidalgo,
G. Pellegrini
Abstract:
Thin pad detectors made from 75 $μ$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that the active detector thickness is limited to the epitaxial layer and does not extend into the low resistivity substrate even after the highest fluence. Detector c…
▽ More
Thin pad detectors made from 75 $μ$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that the active detector thickness is limited to the epitaxial layer and does not extend into the low resistivity substrate even after the highest fluence. Detector current was measured under reverse and forward bias. The forward current was higher than the reverse at the same voltage but the difference gets smaller with increasing fluence. Rapid increase of current (breakdown) above ~ 700 V under reverse bias was observed. An annealing study at 60$^\circ$C was made to 1200 minutes of accumulated annealing time. It showed that the reverse current anneals with similar time constants as measured at lower fluences. A small increase of forward current due to annealing was seen. Collected charge was measured with electrons from $^{90}$Sr source in forward and reverse bias configurations. Under reverse bias the collected charge increased linearly with bias voltage up to 6000 electrons at 2.5$\times 10^{16}$ n/cm$^2$ and 3000 electrons at 1$\times 10^{17}$ n/cm$^2$. Rapid increase of noise was measured above $\sim$ 700 V reverse bias due to breakdown resulting in worse S/N ratio. At low bias voltages slightly more charge is measured under forward bias compared to reverse. However better S/N is achieved under reverse bias. Effective trapping times were estimated from charge collection measurements under forward bias showing that at high fluences they are much longer than values extrapolated from low fluence measurements - at 1$\times 10^{17}$ n/cm$^2$ a factor of 6 larger value was measured.
△ Less
Submitted 2 September, 2020; v1 submitted 10 July, 2020;
originally announced July 2020.
-
Annealing effects on operation of thin Low Gain Avalanche Detectors
Authors:
G. Kramberger. V. Cindro,
A. Howard,
Z. Kljun,
I. Mandic,
M. Mikuz
Abstract:
Several thin Low Gain Avalanche Detectors from Hamamatsu Photonics were irradiated with neutrons to different equivalent fluences up to $Φ_{eq}=3\cdot10^{15}$ cm$^{-2}$. After the irradiation they were annealed at 60$^\circ$C in steps to times $>20000$ minutes. Their properties, mainly full depletion voltage, gain layer depletion voltage, generation and leakage current, as well as their performanc…
▽ More
Several thin Low Gain Avalanche Detectors from Hamamatsu Photonics were irradiated with neutrons to different equivalent fluences up to $Φ_{eq}=3\cdot10^{15}$ cm$^{-2}$. After the irradiation they were annealed at 60$^\circ$C in steps to times $>20000$ minutes. Their properties, mainly full depletion voltage, gain layer depletion voltage, generation and leakage current, as well as their performance in terms of collected charge and time resolution, were determined between the steps.
It was found that the effect of annealing on timing resolution and collected charge is not very large and mainly occurs within the first few tens of minutes. It is a consequence of active initial acceptor concentration decrease in the
gain layer with time, where changes of around 10\% were observed. For any relevant annealing times for detector operation the changes of effective doping concentration in the bulk negligibly influences the performance of the device, due to their small thickness and required high bias voltage operation. At very long annealing times the increase of the effective doping concentration in the bulk leads to a significant increase of the electric field in the gain layer and, by that, to the increase of gain at given voltage. The leakage current decreases in accordance with generation current annealing.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
Authors:
S. Xiao,
S. Alderweireldt,
S. Ali,
C. Allaire,
C. Agapopoulou,
N. Atanov,
M. K. Ayoub,
G. Barone,
D. Benchekroun,
A. Buzatu,
D. Caforio,
L. Castillo García,
Y. Chan,
H. Chen,
V. Cindro,
L. Ciucu,
J. Barreiro Guimarães da Costa,
H. Cui,
F. Davó Miralles,
Y. Davydov,
G. d'Amen,
C. de la Taille,
R. Kiuchi,
Y. Fan,
A. Falou
, et al. (75 additional authors not shown)
Abstract:
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated wi…
▽ More
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. Jing,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Experimental Study of Acceptor Removal in UFSD
Authors:
Y. Jin,
H. Ren,
S. Christie,
Z. Galloway,
C. Gee,
C. Labitan,
M. Lockerby,
F. Martinez-McKinney,
S. M. Mazza,
R. Padilla,
H. F. -W. Sadrozinski,
B. Schumm,
A. Seiden,
M. Wilder,
W. Wyatt,
Y. Zhao,
R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
F. Siviero,
V. Sola,
M. Tornago,
V. Cindro,
A. Howard
, et al. (3 additional authors not shown)
Abstract:
The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the doping concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between t…
▽ More
The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the doping concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C-V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.
△ Less
Submitted 16 September, 2020; v1 submitted 16 March, 2020;
originally announced March 2020.
-
Recent Results from Polycrystalline CVD Diamond Detectors
Authors:
RD42 Collaboration,
L. Bäni,
A. Alexopoulos,
M. Artuso,
F. Bachmair,
M. Bartosik,
H. Beck,
V. Bellini,
V. Belyaev,
B. Bentele,
A. Bes,
J. -M. Brom,
M. Bruzzi,
G. Chiodini,
D. Chren,
V. Cindro,
G. Claus,
J. Collot,
J. Cumalat,
A. Dabrowski,
R. D'Alessandro,
D. Dauvergne,
W. de Boer,
C. Dorfer,
M. Dünser
, et al. (87 additional authors not shown)
Abstract:
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse hei…
▽ More
Diamond is a material in use at many nuclear and high energy facilities due to its inherent radiation tolerance and ease of use. We have characterized detectors based on chemical vapor deposition (CVD) diamond before and after proton irradiation. We present preliminary results of the spatial resolution of unirradiated and irradiated CVD diamond strip sensors. In addition, we measured the pulse height versus particle rate of unirradiated and irradiated polycrystalline CVD (pCVD) diamond pad detectors up to a particle flux of $20\,\mathrm{MHz/cm^2}$ and a fluence up to $4 \times 10^{15}\,n/\mathrm{cm^2}$.
△ Less
Submitted 16 October, 2019;
originally announced October 2019.
-
Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC
Authors:
M. Dyndal,
V. Dao,
P. Allport,
I. Asensi Tortajada,
M. Barbero,
S. Bhat,
D. Bortoletto,
I. Berdalovic,
C. Bespin,
C. Buttar,
I. Caicedo,
R. Cardella,
F. Dachs,
Y. Degerli,
H. Denizli,
L. Flores Sanz de Acedo,
P. Freeman,
L. Gonella,
A. Habib,
T. Hemperek,
T. Hirono,
B. Hiti,
T. Kugathasan,
I. Mandić,
D. Maneuski
, et al. (19 additional authors not shown)
Abstract:
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silico…
▽ More
Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.
△ Less
Submitted 14 December, 2019; v1 submitted 26 September, 2019;
originally announced September 2019.
-
Determination of the electric field in highly-irradiated silicon sensors using edge-TCT measurements
Authors:
R. Klanner,
G. Kramberger,
I. Mandic,
M. Mikuz,
M. Milovanovic,
J. Schwandt
Abstract:
A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are investigated by simulations of non-irradiated $n^+p$ pad sensors and by the analysis of edge-TCT data from non-irradiated $n^+p$ strip-detectors. The method is then used…
▽ More
A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are investigated by simulations of non-irradiated $n^+p$ pad sensors and by the analysis of edge-TCT data from non-irradiated $n^+p$ strip-detectors. The method is then used to determine the position dependent electric field and charge density in $n^+p$ strip detectors irradiated by reactor neutrons to fluences between 1 and $10 \times 10^{15}$ cm$^{-2}$ for forward-bias voltages between 25 V and up to 550 V and for reverse-bias voltages between 50 V and 800 V. In all cases the velocity profiles are well described. The electric fields and charge densities determined provide quantitative insights into the effects of radiation damage for silicon sensors by reactor neutrons.
△ Less
Submitted 11 September, 2019;
originally announced September 2019.
-
Timing performance of small cell 3D silicon detectors
Authors:
G. Kramberger,
V. Cindro,
D. Flores,
S. Hidalgo,
B. Hiti,
M. Manna,
I. Mandić,
M. Mikuž,
D. Quirion,
G. Pellegrini,
M. Zavrtanik
Abstract:
A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time resolution of Low Gain Avalanche Detectors (LGADs). The measurements were compared to those with LGADs and also simulations. The studies showed that the dominant cont…
▽ More
A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time resolution of Low Gain Avalanche Detectors (LGADs). The measurements were compared to those with LGADs and also simulations. The studies showed that the dominant contribution to the timing resolution comes from the time walk originating from different induced current shapes for hits over the cell area. This contribution decreases with higher bias voltages, lower temperatures and smaller cell sizes. It is around 30 ps for a 3D detector of 50x50 um2 cell at 150 V and -20C, which is comparable to the time walk due to Landau fluctuations in LGADs. It even improves for inclined tracks and larger pads composed of multiple cells. A good agreement between measurements and simulations was obtained, thus validating the simulation results.
△ Less
Submitted 15 January, 2019; v1 submitted 8 January, 2019;
originally announced January 2019.
-
Proprieties of FBK UFSDs after neutron and proton irradiation up to 6*10e15 neq/cm2
Authors:
S. M. Mazza,
E. Estrada,
Z. Galloway,
C. Gee,
A. Goto,
Z. Luce,
F. McKinney-Martinez,
R. Rodriguez,
H. F. -W. Sadrozinski,
A. Seiden,
B. Smithers,
Y. Zhao,
V. Cindro,
G. Kramberger,
I. Mandić,
M. Mikuž,
M. Zavrtanik R. Arcidiacono,
N. Cartiglia,
M. Ferrero,
M. Mandurrino,
V. Sola,
A. Staiano,
M. Boscardin,
G. F. Della Betta,
F. Ficorella
, et al. (2 additional authors not shown)
Abstract:
The properties of 60-μm thick Ultra-Fast Silicon Detectors (UFSD) detectors manufactured by Fondazione Bruno Kessler (FBK), Trento (Italy) were tested before and after irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source . This FBK production, called UFSD2, has UFSDs with gain layer made of Boron, Boron low-diffusion, Gallium, Carbonated Boron and Carbonated. The irradiati…
▽ More
The properties of 60-μm thick Ultra-Fast Silicon Detectors (UFSD) detectors manufactured by Fondazione Bruno Kessler (FBK), Trento (Italy) were tested before and after irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source . This FBK production, called UFSD2, has UFSDs with gain layer made of Boron, Boron low-diffusion, Gallium, Carbonated Boron and Carbonated. The irradiation with neutrons took place at the TRIGA reactor in Ljubljana, while the proton irradiation took place at CERN SPS. The sensors were exposed to a neutron fluence of 4*10e14, 8*1014, 1.5*10e15, 3*10e15, 6*10e15 neq/cm2 and to a proton fluence of 9.6*10e14 p/cm2, equivalent to a fluence of 6*10e14 neq/cm2. The internal gain and the timing resolution were measured as a function of bias voltage at -20C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both.
△ Less
Submitted 18 March, 2020; v1 submitted 15 April, 2018;
originally announced April 2018.
-
Comparison of 35 and 50 μm thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2
Authors:
Y. Zhao,
N. Cartiglia,
E. Estrada,
Z. Galloway,
C. Gee,
A. Goto,
Z. Luce,
S. M. Mazza,
F. McKinney-Martinez,
R. Rodriguez,
H. F. -W. Sadrozinski,
A. Seiden V. Cindro,
G. Kramberger,
I. Mandić,
M. Mikuž,
M. Zavrtanik
Abstract:
We report results from the testing of 35 μm thick Ultra-Fast Silicon Detectors (UFSD produced by Hamamatsu Photonics (HPK), Japan and the comparison of these new results to data reported before on 50 μm thick UFSD produced by HPK. The 35 μm thick sensors were irradiated with neutrons to fluences of 0, 1*10^14, 1*10^15, 3*10^15, 6*10^15 neq/cm^2. The sensors were tested pre-irradiation and post-irr…
▽ More
We report results from the testing of 35 μm thick Ultra-Fast Silicon Detectors (UFSD produced by Hamamatsu Photonics (HPK), Japan and the comparison of these new results to data reported before on 50 μm thick UFSD produced by HPK. The 35 μm thick sensors were irradiated with neutrons to fluences of 0, 1*10^14, 1*10^15, 3*10^15, 6*10^15 neq/cm^2. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source. The leakage current, capacitance, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -27C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. Within the fluence range measured, the advantage of the 35 μm thick UFSD in timing accuracy, bias voltage and power can be established.
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Charge collection properties of irradiated depleted CMOS pixel test structures
Authors:
I. Mandić,
V. Cindro,
A. Gorišek,
B. Hiti,
G. Kramberger,
M. Zavrtanik,
M. Mikuž,
T. Hemperek
Abstract:
Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$Ω$cm are presented. Measurements were made before and after irradiation with reactor neutrons up to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Two sets of devices were investigated: unthinned (700 $μ$m) with substrate biased through…
▽ More
Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$Ω$cm are presented. Measurements were made before and after irradiation with reactor neutrons up to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Two sets of devices were investigated: unthinned (700 $μ$m) with substrate biased through the implant on top and thinned (200 $μ$m) with processed and metallised back plane.
Depleted depth was estimated with Edge-TCT and collected charge was measured with $^{90}$Sr source using an external amplifier with 25 ns shaping time. Depleted depth at given bias voltage decreased with increasing neutron fluence but it was still larger than 70 $μ$m at 250 V after the highest fluence. After irradiation much higher collected charge was measured with thinned detectors with processed back plane although the same depleted depth was observed with Edge-TCT. Most probable value of collected charge of over 5000 electrons was measured also after irradiation to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. This is sufficient to ensure successful operation of these detectors at the outer layer of the pixel detector in the ATLAS experiment at the upgraded HL-LHC.
△ Less
Submitted 22 January, 2018; v1 submitted 11 January, 2018;
originally announced January 2018.
-
Radiation Hardness of Thin Low Gain Avalanche Detectors
Authors:
G. Kramberger,
M. Carulla,
E. Cavallaro,
V. Cindro,
D. Flores,
Z. Galloway,
S. Grinstein,
S. Hidalgo,
V. Fadeyev,
J. Lange,
I. Mandic,
G. Medin,
A. Merlos,
F. McKinney-Martinez,
M. Mikuz,
D. Quirion,
G. Pellegrini,
M. Petek,
H. F-W. Sadrozinski,
A. Seiden,
M. Zavrtanik
Abstract:
Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate doping of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations.…
▽ More
Low Gain Avalanche Detectors (LGAD) are based on a n++-p+-p-p++ structure where an appropriate doping of the multiplication layer (p+) leads to high enough electric fields for impact ionization. Gain factors of few tens in charge significantly improve the resolution of timing measurements, particularly for thin detectors, where the timing performance was shown to be limited by Landau fluctuations. The main obstacle for their operation is the decrease of gain with irradiation, attributed to effective acceptor removal in the gain layer. Sets of thin sensors were produced by two different producers on different substrates, with different gain layer doping profiles and thicknesses (45, 50 and 80 um). Their performance in terms of gain/collected charge and leakage current was compared before and after irradiation with neutrons and pions up to the equivalent fluences of 5e15 cm-2. Transient Current Technique and charge collection measurements with LHC speed electronics were employed to characterize the detectors. The thin LGAD sensors were shown to perform much better than sensors of standard thickness (~300 um) and offer larger charge collection with respect to detectors without gain layer for fluences <2e15 cm-2. Larger initial gain prolongs the beneficial performance of LGADs. Pions were found to be more damaging than neutrons at the same equivalent fluence, while no significant difference was found between different producers. At very high fluences and bias voltages the gain appears due to deep acceptors in the bulk, hence also in thin standard detectors.
△ Less
Submitted 16 November, 2017;
originally announced November 2017.
-
Performance of irradiated thin n-in-p planar pixel sensors for the ATLAS Inner Tracker upgrade
Authors:
Natascha Savic,
Julien-Christopher Beyer,
Bojan Hiti,
Alessandro La Rosa,
Gregor Kramberger,
Anna Macchiolo,
Igor Mandic,
Richard Nisius,
Martin Petek
Abstract:
The ATLAS collaboration will replace its tracking detector with new all silicon pixel and strip systems. This will allow to cope with the higher radiation and occupancy levels expected after the 5-fold increase in the luminosity of the LHC accelerator complex (HL-LHC). In the new tracking detector (ITk) pixel modules with increased granularity will implement to maintain the occupancy with a higher…
▽ More
The ATLAS collaboration will replace its tracking detector with new all silicon pixel and strip systems. This will allow to cope with the higher radiation and occupancy levels expected after the 5-fold increase in the luminosity of the LHC accelerator complex (HL-LHC). In the new tracking detector (ITk) pixel modules with increased granularity will implement to maintain the occupancy with a higher track density. In addition, both sensors and read-out chips composing the hybrid modules will be produced employing more radiation hard technologies with respect to the present pixel detector. Due to their outstanding performance in terms of radiation hardness, thin n-in-p sensors are promising candidates to instrument a section of the new pixel system. Recently produced and developed sensors of new designs will be presented. To test the sensors before interconnection to chips, a punch-through biasing structure has been implemented. Its design has been optimized to decrease the possible tracking efficiency losses observed. After irradiation, they were caused by the punch-through biasing structure. A sensor compatible with the ATLAS FE-I4 chip with a pixel size of 50x250 $\mathrmμ$m$^{2}$, subdivided into smaller pixel implants of 30x30 $\mathrmμ$m$^{2}$ size was designed to investigate the performance of the 50x50 $\mathrmμ$m$^{2}$ pixel cells foreseen for the HL-LHC. Results on sensor performance of 50x250 and 50x50 $\mathrmμ$m$^{2}$ pixel cells in terms of efficiency, charge collection and electric field properties are obtained with beam tests and the Transient Current Technique.
△ Less
Submitted 25 September, 2017;
originally announced September 2017.
-
Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2
Authors:
Z. Galloway,
V. Fadeyev,
P. Freeman,
E. Gkougkousis,
B. Gruey,
C. A. Labitan,
Z. Luce,
F. McKinney-Martinez,
H. F. -W. Sadrozinski,
A. Seiden,
E. Spencer,
M. Wilder,
N. Woods,
A. Zatserklyaniy,
Y. Zhao,
N. Cartiglia,
M. Ferrero,
S. Giordanengo,
M. Mandurrino,
A. Staiano,
V. Sola,
F. Cenna,
F. Fausti,
R. Arcidiacono,
F. Carnasecchi
, et al. (5 additional authors not shown)
Abstract:
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in th…
▽ More
In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.
△ Less
Submitted 10 April, 2020; v1 submitted 16 July, 2017;
originally announced July 2017.
-
Gain and time resolution of 45 $μ$m thin Low Gain Avalanche Detectors before and after irradiation up to a fluence of $10^{15}$ n$_{eq}$/cm$^2$
Authors:
J. Lange,
M. Carulla,
E. Cavallaro,
L. Chytka,
P. M. Davis,
D. Flores,
F. Förster,
S. Grinstein,
S. Hidalgo,
T. Komarek,
G. Kramberger,
I. Mandić,
A. Merlos,
L. Nozka,
G. Pellegrini,
D. Quirion,
T. Sykora
Abstract:
Low Gain Avalanche Detectors (LGADs) are silicon sensors with a built-in charge multiplication layer providing a gain of typically 10 to 50. Due to the combination of high signal-to-noise ratio and short rise time, thin LGADs provide good time resolutions.
LGADs with an active thickness of about 45 $μ$m were produced at CNM Barcelona. Their gains and time resolutions were studied in beam tests f…
▽ More
Low Gain Avalanche Detectors (LGADs) are silicon sensors with a built-in charge multiplication layer providing a gain of typically 10 to 50. Due to the combination of high signal-to-noise ratio and short rise time, thin LGADs provide good time resolutions.
LGADs with an active thickness of about 45 $μ$m were produced at CNM Barcelona. Their gains and time resolutions were studied in beam tests for two different multiplication layer implantation doses, as well as before and after irradiation with neutrons up to $10^{15}$ n$_{eq}$/cm$^2$.
The gain showed the expected decrease at a fixed voltage for a lower initial implantation dose, as well as for a higher fluence due to effective acceptor removal in the multiplication layer. Time resolutions below 30 ps were obtained at the highest applied voltages for both implantation doses before irradiation. Also after an intermediate fluence of $3\times10^{14}$ n$_{eq}$/cm$^2$, similar values were measured since a higher applicable reverse bias voltage could recover most of the pre-irradiation gain. At $10^{15}$ n$_{eq}$/cm$^2$, the time resolution at the maximum applicable voltage of 620 V during the beam test was measured to be 57 ps since the voltage stability was not good enough to compensate for the gain layer loss. The time resolutions were found to follow approximately a universal function of gain for all implantation doses and fluences.
△ Less
Submitted 6 May, 2017; v1 submitted 27 March, 2017;
originally announced March 2017.
-
Charge collection properties in an irradiated pixel sensor built in a thick-film HV-SOI process
Authors:
B. Hiti,
V. Cindro,
A. Gorišek,
T. Hemperek,
T. Kishishita,
G. Kramberger,
H. Krüger,
I. Mandić,
M. Mikuž,
N. Wermes,
M. Zavrtanik
Abstract:
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiat…
▽ More
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiation. In this article we present results of an extensive irradiation hardness study with neutrons up to a fluence of 1x10e16 neq/cm2. Charge collection in a passive pixelated structure was measured by Edge Transient Current Technique (E-TCT). The evolution of the effective space charge concentration was found to be compliant with the acceptor removal model, with the minimum of the space charge concentration being reached after 5x10e14 neq/cm2. An investigation of the in-pixel uniformity of the detector response revealed parasitic charge collection by the epitaxial silicon layer characteristic for the SOI design. The results were backed by a numerical simulation of charge collection in an equivalent detector layout.
△ Less
Submitted 26 October, 2017; v1 submitted 23 January, 2017;
originally announced January 2017.
-
Neutron irradiation test of depleted CMOS pixel detector prototypes
Authors:
Igor Mandić,
Vladimir Cindro,
Andrej Gorišek,
Bojan Hiti,
Gregor Kramberger,
Marko Mikuž,
Marko Zavrtanik,
Tomasz Hemperek,
Michael Daas,
Fabian Hügging,
Hans Krügerc,
David-Leon Pohl,
Norbert Wermes,
Laura Gonella
Abstract:
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$Ω$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation. The test structures were produced for investigation of CMOS technology in tracking detectors for experiments at HL-LHC upgrade. Measurements were made with passive d…
▽ More
Charge collection properties of depleted CMOS pixel detector prototypes produced on p-type substrate of 2 k$Ω$cm initial resistivity (by LFoundry 150 nm process) were studied using Edge-TCT method before and after neutron irradiation. The test structures were produced for investigation of CMOS technology in tracking detectors for experiments at HL-LHC upgrade. Measurements were made with passive detector structures in which current pulses induced on charge collecting electrodes could be directly observed. Thickness of depleted layer was estimated and studied as function of neutron irradiation fluence. An increase of depletion thickness was observed after first two irradiation steps to 1$\cdot$10$^{13}$ n/cm$^{2}$ and 5$\cdot$10$^{13}$ n/cm$^{2}$ and attributed to initial acceptor removal. At higher fluences the depletion thickness at given voltage decreases with increasing fluence because of radiation induced defects contributing to the effective space charge concentration. The behaviour is consistent with that of high resistivity silicon used for standard particle detectors. The measured thickness of the depleted layer after irradiation with 1$\cdot$10$^{15}$ n/cm$^{2}$ is more than 50 $μ$m at 100 V bias. This is sufficient to guarantee satisfactory signal/noise performance on outer layers of pixel trackers in HL-LHC experiments.
△ Less
Submitted 18 January, 2017;
originally announced January 2017.
-
Studies of irradiated AMS H35 CMOS detectors for the ATLAS tracker upgrade
Authors:
Emanuele Cavallaro,
Raimon Casanova,
Fabian Förster,
Sebastian Grinstein,
Jörn Lange,
Gregor Kramberger,
Igor Mandić,
Carles Puigdengoles,
Stefano Terzo
Abstract:
Silicon detectors based on the HV-CMOS technology are being investigated as possible candidate for the outer layers of the ATLAS pixel detector for the High Luminosity LHC. In this framework the H35Demo ASIC has been produced in the 350 nm AMS technology (H35). The H35Demo chip has a large area ($18.49 \times 24.40 \, \mathrm{mm^2}$) and includes four different pixel matrices and three test struct…
▽ More
Silicon detectors based on the HV-CMOS technology are being investigated as possible candidate for the outer layers of the ATLAS pixel detector for the High Luminosity LHC. In this framework the H35Demo ASIC has been produced in the 350 nm AMS technology (H35). The H35Demo chip has a large area ($18.49 \times 24.40 \, \mathrm{mm^2}$) and includes four different pixel matrices and three test structures. In this paper the radiation hardness properties, in particular the evolution of the depletion region with fluence is studied using edge-TCT on test structures. Measurements on the test structures from chips with different substrate resistivity are shown for non irradiated and irradiated devices up to a cumulative fluence of $2 \cdot 10^{15} \, \mathrm{1\,MeV\, n_{eq} / cm^{2}}$.
△ Less
Submitted 9 January, 2017; v1 submitted 15 November, 2016;
originally announced November 2016.
-
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Authors:
N. Cartiglia,
A. Staiano,
V. Sola,
R. Arcidiacono,
R. Cirio,
F. Cenna,
M. Ferrero,
V. Monaco,
R. Mulargia,
M. Obertino,
F. Ravera,
R. Sacchi,
A. Bellora,
S. Durando,
M. Mandurrino,
N. Minafra,
V. Fadeyev,
P. Freeman,
Z. Galloway,
E. Gkougkousis,
H. Grabas,
B. Gruey,
C. A. Labitan,
R. Losakul,
Z. Luce
, et al. (18 additional authors not shown)
Abstract:
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below th…
▽ More
In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 μm) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.
△ Less
Submitted 3 January, 2017; v1 submitted 30 August, 2016;
originally announced August 2016.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.