-
Integrated impedance sensing of liquid sample plug flow enables automated high throughput NMR spectroscopy
Authors:
Omar Nassar,
Mazin Jouda,
Michael Rapp,
Dario Mager,
Jan G. Korvink,
Neil MacKinnon
Abstract:
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample…
▽ More
A novel approach for automated high throughput NMR spectroscopy with improved mass-sensitivity is accomplished by integrating microfluidic technologies and micro-NMR resonators. A flow system is utilized to transport a sample of interest from outside the NMR magnet through the NMR detector, circumventing the relatively vast dead volume in the supplying tube by loading a series of individual sample plugs separated by an immiscible fluid. This dual-phase flow demands a real-time robust sensing system to track the sample position and velocities and synchronize the NMR acquisition. In this contribution, we describe an NMR probe head that possesses a microfluidic system featuring: i) a micro saddle coil for NMR spectroscopy and ii) a pair of interdigitated capacitive sensors flanking the NMR detector for continuous position and velocity monitoring of the plugs with respect to the NMR detector. The system was successfully tested for automating flow-based measurement in a 500 MHz NMR system, enabling high resolution spectroscopy and NMR sensitivity of 2.18 $nmol \ s^{1/2}$ with the flow sensors in operation. The flow sensors featured sensitivity to an absolute difference of 0.2 in relative permittivity, enabling distinction between most common solvents. It was demonstrated that a fully automated NMR measurement of nine individual 120 $μ$L samples could be done within 3.6 min or effectively 15.3 s per sample.
△ Less
Submitted 16 November, 2020;
originally announced November 2020.
-
NMR microscopy for in vivo metabolomics, digitally twinned by computational systems biology, needs a sensitivity boost
Authors:
Jan G. Korvink,
Vlad Badilita,
Lorenzo Bordonali,
Mazin Jouda,
Dario Mager,
Neil MacKinnon
Abstract:
The metabolism of an organism is regulated at the cellular level, yet is strongly influenced by its environment. The precise metabolomic study of living organisms is currently hampered by measurement sensitivity: most metabolomic measurement techniques involve some compromise, in that averaging is performed over a volume significantly larger than a single cell, or require invasion of the organism,…
▽ More
The metabolism of an organism is regulated at the cellular level, yet is strongly influenced by its environment. The precise metabolomic study of living organisms is currently hampered by measurement sensitivity: most metabolomic measurement techniques involve some compromise, in that averaging is performed over a volume significantly larger than a single cell, or require invasion of the organism, or arrest the state of the organism. NMR is an inherently non-invasive chemometric and imaging method, and hence in principle suitable for metabolomic measurements. The digital twin of metabolomics is computational systems biology, so that NMR microscopy is potentially a viable approach with which to join the theoretical and experimental exploration of the metabolomic and behavioural response of organisms. This prospect paper considers the challenge of performing in vivo NMR-based metabolomics on the small organism C. elegans, points the way towards possible solutions created using MEMS techniques, and highlights currently insurmountable challenges.
△ Less
Submitted 27 July, 2017;
originally announced July 2017.
-
Magnetic Flux Tailoring through Lenz Lenses in Toroidal Diamond Indenter Cells: A New Pathway to High Pressure Nuclear Magnetic Resonance
Authors:
Thomas Meier,
Nan Wang,
Dario Mager,
Jan G. Korvink,
Sylvain Petigirard,
Leonid Dubrovinsky
Abstract:
A new pathway to nuclear magnetic resonance spectroscopy in high pressure diamond anvil cells is introduced, using inductively coupled broadband passive electro-magnetic lenses to locally amplify the magnetic flux at the isolated sample, leading to an increase in sensitivity. The lenses are adopted for the geometrical restrictions imposed by a toroidal diamond indenter cell, and yield high signal-…
▽ More
A new pathway to nuclear magnetic resonance spectroscopy in high pressure diamond anvil cells is introduced, using inductively coupled broadband passive electro-magnetic lenses to locally amplify the magnetic flux at the isolated sample, leading to an increase in sensitivity. The lenses are adopted for the geometrical restrictions imposed by a toroidal diamond indenter cell, and yield high signal-to-noise ratios at pressures as high as 72 GPa, at initial sample volumes of only 230 pl. The corresponding levels of detection, LODt, are found to be up to four orders of magnitude lower compared to formerly used solenoidal micro-coils in diamond anvil cells, as shown by Proton-NMR measurements on paraffin oil. This approach opens up the field of ultra-high pressure sciences for one of the most versatile spectroscopic methods available in a pressure range unprecedended up to now.
△ Less
Submitted 24 May, 2017;
originally announced June 2017.
-
High voltage charging system for pulsed power generators
Authors:
M. Evans,
B. Foy,
D. Mager,
R. Shapovalov,
P. -A. Gourdain
Abstract:
A robust and portable power supply has been developed specifically for charging linear transformer drivers, a modern incarnation of fast pulsed power generators. It is capable of generator +100 kV and -100 kV at 1 mA, while withstanding the large voltage spikes generated when the pulsed-power generator is triggered. The three-stage design combines a zero-voltage switching circuit, a step-up transf…
▽ More
A robust and portable power supply has been developed specifically for charging linear transformer drivers, a modern incarnation of fast pulsed power generators. It is capable of generator +100 kV and -100 kV at 1 mA, while withstanding the large voltage spikes generated when the pulsed-power generator is triggered. The three-stage design combines a zero-voltage switching circuit, a step-up transformer using ferrite cores, and a dual Cockcroft-Walton voltage multiplier. The zero-voltage switching circuit drives the primary of the transformer in parallel with a capacitor. With this driver, the tank circuit naturally remain in its resonant state, allowing for maximum energy coupling between the zero-voltage switching circuit and the Cockcroft-Walton voltage multiplier across a wide range of loading conditions.
△ Less
Submitted 3 July, 2018; v1 submitted 12 May, 2017;
originally announced May 2017.
-
HADES: a High Amperage Driver for Extreme States
Authors:
P. -A. Gourdain,
M. Evans,
B. Foy,
D. Mager,
R. McBride,
R. Spielman
Abstract:
Linear transformer drivers (LTD) allow to greatly reduce the size of pulsed-power drivers while increasing their efficiency and repetition rate. However, limitations on the capacitors voltage and current exist, mostly driven by technological imperatives. As a result, LTD required to be connected in series and in parallel to form a practical pulsed-power generator. The High Amperage Driver for Extr…
▽ More
Linear transformer drivers (LTD) allow to greatly reduce the size of pulsed-power drivers while increasing their efficiency and repetition rate. However, limitations on the capacitors voltage and current exist, mostly driven by technological imperatives. As a result, LTD required to be connected in series and in parallel to form a practical pulsed-power generator. The High Amperage Driver for Extreme States (HADES) proposed here can generate 250 GW of power, i.e. a 1 MA on current with a rise time of 150 ns into a 20nH load. The key feature of the driver is its size. The machine footprint is less than 5m2 and its height is less than 1.6m. This reduction in footprint, compared to other 1 MA LTD based-systems, comes from a compact transmission line geometry which allow to connect LTDs is series and in parallel efficiently. This paper summarizes this design and describes HADES operation and maintenance.
△ Less
Submitted 11 May, 2017;
originally announced May 2017.