X-ray fluorescence computed tomography (XFCT) imaging with a superfine pencil beam x-ray source
Authors:
Ignacio O. Romero,
Yile Fang,
Michael Lun,
Changqing Li
Abstract:
X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique of x-ray photons, which can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. XFCT has been an active research topic for many years. However, XFCT has not been a popular molecular imaging tool because it has limited molecular sensitivity and spatial resolution. To further in…
▽ More
X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique of x-ray photons, which can be used to sense different elements or nanoparticle (NP) agents inside deep samples or tissues. XFCT has been an active research topic for many years. However, XFCT has not been a popular molecular imaging tool because it has limited molecular sensitivity and spatial resolution. To further investigate XFCT imaging, we present a benchtop XFCT imaging system, in in which a unique pencil beam x-ray source and a ring of x-ray spectrometers were simulated using GATE (Geant4 Application for Tomographic Emission) software. An accelerated majorization minimization (MM) algorithm with an L1 regularization scheme was used to reconstruct the XRF image of Molybdenum (Mo) NP targets from the numerical measurements of GATE simulations. With a low x-ray source output rate, good target localization was achieved with a DICE coefficient of 83.681%. The reconstructed signal intensity of the targets was found to be relatively proportional to the target concentrations if detector number and placement is optimized. The MM algorithm performance was compared with maximum likelihood expectation maximization (ML-EM) and filtered back projection (FBP) algorithms. In the future, the benchtop XFCT imaging system will be tested experimentally
△ Less
Submitted 29 January, 2021;
originally announced January 2021.
-
Development of a focused-X-ray luminescence tomography (FXLT) system
Authors:
Michael C Lun,
Wei Zhang,
Yue Zhao,
Jeffrey Anker,
Wenxiang Cong,
Ge Wang,
Changqing Li
Abstract:
Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise ratio and poor image quality, mainly due to strong optical scattering especially in deep tissues. Recently, X-ray luminescence computed tomography (XLCT) has emerge…
▽ More
Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise ratio and poor image quality, mainly due to strong optical scattering especially in deep tissues. Recently, X-ray luminescence computed tomography (XLCT) has emerged as a hybrid molecular imaging modality and shown great promises in overcoming the optical scattering in deep tissues. However, its high spatial resolution capacity has not been fully implemented yet. In this paper, with a superfine focused X-ray beam we design a focused-X-ray luminescence tomography (FXLT) system for spatial resolution better than 150 micrometers and molecular sensitivity of 2 micromolar. First, we describe our system design. Then, we demonstrate that the molecular sensitivity of FXLT is about 5 micromolar considering the emitted visible photons from background. Furthermore, we analyze the measurement time per scan from measured photons numbers with a fiber bundle-PMT setup, report numerical and experimental results. Finally, we specify the imaging system performance based on numerical simulations and physical measurements.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
X-ray luminescence computed tomography using a focused X-ray beam
Authors:
Wei Zhang,
Michael C Lun,
Alex Anh-Tu Nguyen,
Changqing Li
Abstract:
Due to the low X-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device (EMCCD) camera setup, the collimator based narrow beam X-ray luminescence computed tomography (XLCT) usually requires a long measurement time. In this paper, we, for the first time, report a focused X-ray beam based XLCT imaging system with measurements by a single o…
▽ More
Due to the low X-ray photon utilization efficiency and low measurement sensitivity of the electron multiplying charge coupled device (EMCCD) camera setup, the collimator based narrow beam X-ray luminescence computed tomography (XLCT) usually requires a long measurement time. In this paper, we, for the first time, report a focused X-ray beam based XLCT imaging system with measurements by a single optical fiber bundle and a photomultiplier tube (PMT). An X-ray tube with a polycapillary lens was used to generate a focused X-ray beam whose X-ray photon density is 1200 times larger than a collimated X-ray beam. An optical fiber bundle was employed to collect and deliver the emitted photons on the phantom surface to the PMT. The total measurement time was reduced to 12.5 minutes. For numerical simulations of both single and six fiber bundle cases, we were able to reconstruct six targets successfully. For the phantom experiment, two targets with an edge-to-edge distance of 0.4 mm and a center-to-center distance of 0.8 mm were successfully reconstructed by the measurement setup with a single fiber bundle and a PMT.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.