Skip to main content

Showing 51–58 of 58 results for author: Luethi, M

.
  1. arXiv:1512.05968  [pdf, other

    physics.ins-det hep-ex

    On the Electric Breakdown in Liquid Argon at Centimeter Scale

    Authors: M. Auger, A. Blatter, A. Ereditato, D. Goeldi, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, T. Strauss, M. S. Weber

    Abstract: We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first t… ▽ More

    Submitted 16 March, 2016; v1 submitted 18 December, 2015; originally announced December 2015.

    Comments: Minor revision according to editor report. 17 pages, 15 figures, 2 tables. Turboencabulator

    Journal ref: 2016 JINST 11 P03017

  2. arXiv:1503.01520  [pdf, other

    physics.ins-det hep-ex

    A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam

    Authors: R. Acciarri, C. Adams, R. An, C. Andreopoulos, A. M. Ankowski, M. Antonello, J. Asaadi, W. Badgett, L. Bagby, B. Baibussinov, B. Baller, G. Barr, N. Barros, M. Bass, V. Bellini, P. Benetti, S. Bertolucci, K. Biery, H. Bilokon, M. Bishai, A. Bitadze, A. Blake, F. Boffelli, T. Bolton, M. Bonesini , et al. (199 additional authors not shown)

    Abstract: A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-sca… ▽ More

    Submitted 4 March, 2015; originally announced March 2015.

    Comments: 209 pages, 129 figures

  3. arXiv:1408.7046  [pdf, other

    physics.ins-det hep-ex

    Performance of cryogenic charge readout electronics with the ARGONTUBE LAr TPC

    Authors: A. Ereditato, D. Goeldi, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, M. Schenk, T. Strauss, M. S. Weber, M. Zeller

    Abstract: ARGONTUBE is a liquid argon time projection chamber (TPC) with an electron drift length of up to 5 m equipped with cryogenic charge-sensitive preamplifiers. In this work, we present results on its performance including a comparison of the new cryogenic charge-sensitive preamplifiers with the previously used room-temperature-operated charge preamplifiers.

    Submitted 30 October, 2014; v1 submitted 29 August, 2014; originally announced August 2014.

  4. arXiv:1408.6635  [pdf, other

    physics.ins-det hep-ex

    Measurement of the drift field in the ARGONTUBE LAr TPC with 266~nm pulsed laser beams

    Authors: A. Ereditato, D. Goeldi, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, M. Schenk, T. Strauss, M. S. Weber, M. Zeller

    Abstract: ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift field generated in-situ by a Greinacher voltage multiplier circuit. We present results on the measurement of the drift-field distribution inside ARGONTUBE using straight ionization tracks generated by an intense UV laser beam. Our analysis is based on a simplified model of the charging of a multi-stage Greinacher circuit to… ▽ More

    Submitted 30 October, 2014; v1 submitted 28 August, 2014; originally announced August 2014.

    Journal ref: JINST 9 (2014) 11, P11010

  5. arXiv:1406.6400  [pdf, other

    physics.ins-det hep-ex

    A steerable UV laser system for the calibration of liquid argon time projection chambers

    Authors: A. Ereditato, I. Kreslo, M. Lüthi, C. Rudolf von Rohr, M. Schenk, T. Strauss, M. Weber, M. Zeller

    Abstract: A number of liquid argon time projection chambers (LAr TPC's) are being build or are proposed for neutrino experiments on long- and short baseline beams. For these detectors a distortion in the drift field due to geometrical or physics reasons can affect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity this distortion could be of the same magnitude… ▽ More

    Submitted 4 October, 2014; v1 submitted 24 June, 2014; originally announced June 2014.

    Journal ref: JINST 9 (2014) T11007

  6. arXiv:1406.3929  [pdf, ps, other

    physics.ins-det hep-ex

    A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters

    Authors: M. Auger, A. Ereditato, D. Goeldi, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, T. Strauss, T. Tolba, M. S. Weber

    Abstract: We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier.

    Submitted 16 June, 2014; originally announced June 2014.

  7. arXiv:1401.6693  [pdf, ps, other

    physics.ins-det hep-ex

    Experimental study of electric breakdowns in liquid argon at centimeter scale

    Authors: A. Blatter, A. Ereditato, C. -C. Hsu, S. Janos, I. Kreslo, M. Luethi, C. Rudolf von Rohr, M. Schenk, T. Strauss, M. S. Weber, M. Zeller

    Abstract: In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are… ▽ More

    Submitted 11 February, 2014; v1 submitted 26 January, 2014; originally announced January 2014.

    Journal ref: JINST 9 (2014) P04006

  8. arXiv:1310.6601  [pdf, other

    physics.ins-det hep-ex

    Development of a camera casing suited for cryogenic and vacuum applications

    Authors: S. C. Delaquis, R. Gornea, S. Janos, M. Lüthi, Ch. Rudolf von Rohr, M. Schenk, J. -L. Vuilleumier

    Abstract: We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a lighting system. The design of the camera casing and its components are discussed in detail. Pictures taken by this cryo-camera while immersed in argon vapour and liquid nitrogen are presented. The cryo-camera can provide… ▽ More

    Submitted 24 October, 2013; originally announced October 2013.