Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising
Authors:
Ashkan Pakzad,
Robert Turnbull,
Simon J. Mutch,
Thomas A. Leatham,
Darren Lockie,
Jane Fox,
Beena Kumar,
Daniel Häsermann,
Christopher J. Hall,
Anton Maksimenko,
Benedicta D. Arhatari,
Yakov I. Nesterets,
Amir Entezam,
Seyedamir T. Taba,
Patrick C. Brennan,
Timur E. Gureyev,
Harry M. Quiney
Abstract:
Breast cancer is the most frequently diagnosed human cancer in the United States at present. Early detection is crucial for its successful treatment. X-ray mammography and digital breast tomosynthesis are currently the main methods for breast cancer screening. However, both have known limitations in terms of their sensitivity and specificity to breast cancers, while also frequently causing patient…
▽ More
Breast cancer is the most frequently diagnosed human cancer in the United States at present. Early detection is crucial for its successful treatment. X-ray mammography and digital breast tomosynthesis are currently the main methods for breast cancer screening. However, both have known limitations in terms of their sensitivity and specificity to breast cancers, while also frequently causing patient discomfort due to the requirement for breast compression. Breast computed tomography is a promising alternative, however, to obtain high-quality images, the X-ray dose needs to be sufficiently high. As the breast is highly radiosensitive, dose reduction is particularly important. Phase-contrast computed tomography (PCT) has been shown to produce higher-quality images at lower doses and has no need for breast compression. It is demonstrated in the present study that, when imaging full fresh mastectomy samples with PCT, deep learning-based image denoising can further reduce the radiation dose by a factor of 16 or more, without any loss of image quality. The image quality has been assessed both in terms of objective metrics, such as spatial resolution and contrast-to-noise ratio, as well as in an observer study by experienced medical imaging specialists and radiologists. This work was carried out in preparation for live patient PCT breast cancer imaging, initially at specialized synchrotron facilities.
△ Less
Submitted 9 May, 2025;
originally announced May 2025.
-
Comparison of three reconstruction algorithms for low-dose phase-contrast computed tomography of the breast with synchrotron radiation
Authors:
Sandro Donato,
Simone Caputo,
Luca Brombal,
Bruno Golosio,
Renata Longo,
Giuliana Tromba,
Raffaele G. Agostino,
Gianluigi Greco,
Benedicta D. Arhatari,
Chris Hall,
Anton Maksimenko,
Daniel Hausermann,
Darren Lockie,
Jane Fox,
Beena Kumar,
Sarah Lewis,
Patrick C. Brennan,
Harry M. Quiney,
Seyedamir Tavakoli Taba,
Timur E. Gureyev
Abstract:
Three different computed tomography (CT) reconstruction algorithms: Filtered Back Projection (FBP), Unified Tomographic Reconstruction (UTR) and customized Simultaneous Algebraic Reconstruction Technique (cSART), have been systematically compared and evaluated using experimental data from CT scans of ten fresh mastectomy samples collected at the Imaging and Medical beamline of the Australian Synch…
▽ More
Three different computed tomography (CT) reconstruction algorithms: Filtered Back Projection (FBP), Unified Tomographic Reconstruction (UTR) and customized Simultaneous Algebraic Reconstruction Technique (cSART), have been systematically compared and evaluated using experimental data from CT scans of ten fresh mastectomy samples collected at the Imaging and Medical beamline of the Australian Synchrotron. All the scans were collected at the mean glandular dose of 2 mGy, using monochromatic X-rays with 32 keV energy, flat-panel detectors with 0.1 mm pixels and 6 meter distance between the rotation stage and the detector. Paganin's phase retrieval method was used in conjunction with all three CT reconstruction algorithms. The reconstructed images were compared in terms of the objective image quality characteristics, including spatial resolution, contrast, signal-to-noise, and contrast-to-noise ratios. The images were also evaluated by seven experienced medical imaging specialists, rating perceptible contrast, sharpness of tissue interfaces, image noise, calcification visibility and overall image quality. Of the three compared algorithms, cSART was clearly superior to UTR and FBP in terms of most measured objective image quality characteristics. At the same time, the results of the subjective quality evaluation consistently favoured the images reconstructed by FBP, followed by UTR, with cSART receiving lower scores on average. We argue that this apparent disagreement between the objective and subjective assessments of image quality can be explained by the importance assigned to image contrast in the subjective assessment, while the signal-to-noise ratio seemed to receive relatively low weighting. This study was conducted in preparation for phase-contrast breast CT imaging of live patients at Australian Synchrotron (Melbourne, Australia).
△ Less
Submitted 16 December, 2024;
originally announced December 2024.
-
Tomographic phase and attenuation extraction for a sample composed of unknown materials using X-ray propagation-based phase-contrast imaging
Authors:
Samantha J. Alloo,
David M. Paganin,
Kaye S. Morgan,
Timur E. Gureyev,
Sherry C. Mayo,
Sara Mohammadi,
Darren Lockie,
Ralf Hendrik Menk,
Fulvia Arfelli,
Fabrizio Zanconati,
Giuliana Tromba,
Konstantin M. Pavlov
Abstract:
Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the X-ray attenuation, $β$, and refraction, $δ$, components of the complex…
▽ More
Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the X-ray attenuation, $β$, and refraction, $δ$, components of the complex refractive index of distinct materials within an unknown sample. The method involves curve-fitting an error-function-based model to a phase-retrieved interface in a PB-PCXI tomographic reconstruction, which is obtained when Paganin-type phase-retrieval is applied with incorrect values of $δ$ and $β$. The fit parameters can then be used to calculate true $δ$ and $β$ values for composite materials. This approach requires no a priori sample information, making it broadly applicable. Our PB-PCXI reconstruction is single distance, requiring only one exposure per tomographic angle, which is important for radiosensitive samples. We apply this approach to a breast-tissue sample, recovering the refraction component, $δ$, with 0.6 - 2.4\% accuracy compared to theoretical values.
△ Less
Submitted 14 October, 2021; v1 submitted 12 October, 2021;
originally announced October 2021.