-
Future Circular Collider Feasibility Study Report: Volume 2, Accelerators, Technical Infrastructure and Safety
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
A. Abada
, et al. (1439 additional authors not shown)
Abstract:
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory;…
▽ More
In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration hosted by CERN. This report describes the FCC integrated programme, which consists of two stages: an electron-positron collider (FCC-ee) in the first phase, serving as a high-luminosity Higgs, top, and electroweak factory; followed by a proton-proton collider (FCC-hh) at the energy frontier in the second phase.
FCC-ee is designed to operate at four key centre-of-mass energies: the Z pole, the WW production threshold, the ZH production peak, and the top/anti-top production threshold - delivering the highest possible luminosities to four experiments. Over 15 years of operation, FCC-ee will produce more than 6 trillion Z bosons, 200 million WW pairs, nearly 3 million Higgs bosons, and 2 million top anti-top pairs. Precise energy calibration at the Z pole and WW threshold will be achieved through frequent resonant depolarisation of pilot bunches. The sequence of operation modes remains flexible.
FCC-hh will operate at a centre-of-mass energy of approximately 85 TeV - nearly an order of magnitude higher than the LHC - and is designed to deliver 5 to 10 times the integrated luminosity of the HL-LHC. Its mass reach for direct discovery extends to several tens of TeV. In addition to proton-proton collisions, FCC-hh is capable of supporting ion-ion, ion-proton, and lepton-hadron collision modes.
This second volume of the Feasibility Study Report presents the complete design of the FCC-ee collider, its operation and staging strategy, the full-energy booster and injector complex, required accelerator technologies, safety concepts, and technical infrastructure. It also includes the design of the FCC-hh hadron collider, development of high-field magnets, hadron injector options, and key technical systems for FCC-hh.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 3, Civil Engineering, Implementation and Sustainability
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. I…
▽ More
Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region.
The report describes development of the project scenario based on the 'avoid-reduce-compensate' iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain - including numerous urban, economic, social, and technical aspects - confirmed the project's technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a concise summary of the studies conducted to document the current state of the environment.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors
Authors:
M. Benedikt,
F. Zimmermann,
B. Auchmann,
W. Bartmann,
J. P. Burnet,
C. Carli,
A. Chancé,
P. Craievich,
M. Giovannozzi,
C. Grojean,
J. Gutleber,
K. Hanke,
A. Henriques,
P. Janot,
C. Lourenço,
M. Mangano,
T. Otto,
J. Poole,
S. Rajagopalan,
T. Raubenheimer,
E. Todesco,
L. Ulrici,
T. Watson,
G. Wilkinson,
P. Azzi
, et al. (1439 additional authors not shown)
Abstract:
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model.…
▽ More
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools /reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
△ Less
Submitted 25 April, 2025;
originally announced May 2025.
-
The Muon Collider
Authors:
Carlotta Accettura,
Simon Adrian,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aime',
Avni Aksoy,
Gian Luigi Alberghi,
Siobhan Alden,
Luca Alfonso,
Muhammad Ali,
Anna Rita Altamura,
Nicola Amapane,
Kathleen Amm,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Ludovica Aperio Bella,
Rob Appleby,
Artur Apresyan,
Pouya Asadi,
Mohammed Attia Mahmoud,
Bernhard Auchmann,
John Back,
Anthony Badea,
Kyu Jung Bae
, et al. (433 additional authors not shown)
Abstract:
Muons offer a unique opportunity to build a compact high-energy electroweak collider at the 10 TeV scale. A Muon Collider enables direct access to the underlying simplicity of the Standard Model and unparalleled reach beyond it. It will be a paradigm-shifting tool for particle physics representing the first collider to combine the high-energy reach of a proton collider and the high precision of an…
▽ More
Muons offer a unique opportunity to build a compact high-energy electroweak collider at the 10 TeV scale. A Muon Collider enables direct access to the underlying simplicity of the Standard Model and unparalleled reach beyond it. It will be a paradigm-shifting tool for particle physics representing the first collider to combine the high-energy reach of a proton collider and the high precision of an electron-positron collider, yielding a physics potential significantly greater than the sum of its individual parts. A high-energy muon collider is the natural next step in the exploration of fundamental physics after the HL-LHC and a natural complement to a future low-energy Higgs factory. Such a facility would significantly broaden the scope of particle colliders, engaging the many frontiers of the high energy community.
The last European Strategy for Particle Physics Update and later the Particle Physics Project Prioritisation Panel in the US requested a study of the muon collider, which is being carried on by the International Muon Collider Collaboration. In this comprehensive document we present the physics case, the state of the work on accelerator design and technology, and propose an R\&D project that can make the muon collider a reality.
△ Less
Submitted 30 April, 2025;
originally announced April 2025.
-
Measurement of the emittance of accelerated electron bunches at the AWAKE experiment
Authors:
D. A. Cooke,
F. Pannell,
G. Zevi Della Porta,
J. Farmer,
V. Bencini,
M. Bergamaschi,
S. Mazzoni,
L. Ranc,
E. Senes,
P. Sherwood,
M. Wing,
R. Agnello,
C. C. Ahdida,
C. Amoedo,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
J. M. Arnesano,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
M. Chung,
A. Clairembaud,
C. Davut
, et al. (59 additional authors not shown)
Abstract:
The vertical plane transverse emittance of accelerated electron bunches at the AWAKE experiment at CERN has been determined, using three different methods of data analysis. This is a proof-of-principle measurement using the existing AWAKE electron spectrometer to validate the measurement technique. Large values of the geometric emittance, compared to that of the injection beam, are observed (…
▽ More
The vertical plane transverse emittance of accelerated electron bunches at the AWAKE experiment at CERN has been determined, using three different methods of data analysis. This is a proof-of-principle measurement using the existing AWAKE electron spectrometer to validate the measurement technique. Large values of the geometric emittance, compared to that of the injection beam, are observed ($\sim \SI{0.5}{\milli\metre\milli\radian}$ compared with $\sim \SI{0.08}{\milli\metre\milli\radian}$), which is in line with expectations of emittance growth arising from plasma density ramps and large injection beam bunch size. Future iterations of AWAKE are anticipated to operate in conditions where emittance growth is better controlled, and the effects of the imaging systems of the existing and future spectrometer designs on the ability to measure the emittance are discussed. Good performance of the instrument down to geometric emittances of approximately $\SI{1e-4}{\milli\metre\milli\radian}$ is required, which may be possible with improved electron optics and imaging.
△ Less
Submitted 13 November, 2024;
originally announced November 2024.
-
MuCol Milestone Report No. 5: Preliminary Parameters
Authors:
Carlotta Accettura,
Simon Adrian,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aimé,
Avni Aksoy,
Gian Luigi Alberghi,
Siobhan Alden,
Luca Alfonso,
Nicola Amapane,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Rob Appleby,
Artur Apresyan,
Pouya Asadi,
Mohammed Attia Mahmoud,
Bernhard Auchmann,
John Back,
Anthony Badea,
Kyu Jung Bae,
E. J. Bahng,
Lorenzo Balconi,
Fabrice Balli,
Laura Bandiera
, et al. (369 additional authors not shown)
Abstract:
This document is comprised of a collection of updated preliminary parameters for the key parts of the muon collider. The updated preliminary parameters follow on from the October 2023 Tentative Parameters Report. Particular attention has been given to regions of the facility that are believed to hold greater technical uncertainty in their design and that have a strong impact on the cost and power…
▽ More
This document is comprised of a collection of updated preliminary parameters for the key parts of the muon collider. The updated preliminary parameters follow on from the October 2023 Tentative Parameters Report. Particular attention has been given to regions of the facility that are believed to hold greater technical uncertainty in their design and that have a strong impact on the cost and power consumption of the facility. The data is collected from a collaborative spreadsheet and transferred to overleaf.
△ Less
Submitted 5 November, 2024;
originally announced November 2024.
-
Interim report for the International Muon Collider Collaboration (IMCC)
Authors:
C. Accettura,
S. Adrian,
R. Agarwal,
C. Ahdida,
C. Aimé,
A. Aksoy,
G. L. Alberghi,
S. Alden,
N. Amapane,
D. Amorim,
P. Andreetto,
F. Anulli,
R. Appleby,
A. Apresyan,
P. Asadi,
M. Attia Mahmoud,
B. Auchmann,
J. Back,
A. Badea,
K. J. Bae,
E. J. Bahng,
L. Balconi,
F. Balli,
L. Bandiera,
C. Barbagallo
, et al. (362 additional authors not shown)
Abstract:
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accele…
▽ More
The International Muon Collider Collaboration (IMCC) [1] was established in 2020 following the recommendations of the European Strategy for Particle Physics (ESPP) and the implementation of the European Strategy for Particle Physics-Accelerator R&D Roadmap by the Laboratory Directors Group [2], hereinafter referred to as the the European LDG roadmap. The Muon Collider Study (MuC) covers the accelerator complex, detectors and physics for a future muon collider. In 2023, European Commission support was obtained for a design study of a muon collider (MuCol) [3]. This project started on 1st March 2023, with work-packages aligned with the overall muon collider studies. In preparation of and during the 2021-22 U.S. Snowmass process, the muon collider project parameters, technical studies and physics performance studies were performed and presented in great detail. Recently, the P5 panel [4] in the U.S. recommended a muon collider R&D, proposed to join the IMCC and envisages that the U.S. should prepare to host a muon collider, calling this their "muon shot". In the past, the U.S. Muon Accelerator Programme (MAP) [5] has been instrumental in studies of concepts and technologies for a muon collider.
△ Less
Submitted 28 January, 2025; v1 submitted 17 July, 2024;
originally announced July 2024.
-
Epidemiological impacts of age structures on human malaria transmission
Authors:
Quentin Richard,
Marc Choisy,
Ramsès Djidjou-Demasse,
Thierry Lefèvre
Abstract:
Malaria is one of the most common mosquito-borne diseases widespread in tropical and subtropical regions, causing thousands of deaths every year in the world. In a previous paper, we formulated an age-structured model containing three structural variables: (i) the chronological age of human and mosquito populations, (ii) the time since they are infected, and (iii) humans waning immunity (i.e. the…
▽ More
Malaria is one of the most common mosquito-borne diseases widespread in tropical and subtropical regions, causing thousands of deaths every year in the world. In a previous paper, we formulated an age-structured model containing three structural variables: (i) the chronological age of human and mosquito populations, (ii) the time since they are infected, and (iii) humans waning immunity (i.e. the progressive loss of protective antibodies after recovery). In the present paper, we expand the analysis of this age-structured model and focus on the derivation of entomological and epidemiological results commonly used in the literature, following the works of Smith and McKenzie. We generalize their results to the age-structured case. In order to quantify the impact of neglecting structuring variables such as chronological age, we assigned values from the literature to our model parameters. While some parameters values are readily accessible from the literature, at least those about the human population, the parameters concerning mosquitoes are less commonly documented and the values of a number of them (e.g. mosquito survival in the presence or in absence of infection) can be discussed extensively.
△ Less
Submitted 22 May, 2024; v1 submitted 11 October, 2023;
originally announced October 2023.
-
Understanding the growth mechanism of BaZrS$_3$ chalcogenide perovskite thin films from sulfurized oxide precursors
Authors:
Santhanu Panikar Ramanandan,
Andrea Giunto,
Elias Z. Stutz,
Benoit Xavier Marie Reyner,
Iléane Tiphaine Françoise Marie Lefevre,
Marin Rusu,
Susan Schorr,
Thomas Unold,
Anna Fontcuberta i Morral,
José Márquez Prieto,
Mirjana Dimitrievska
Abstract:
Barium zirconium sulfide (BaZrS3) is an earth-abundant and environmentally friendly chalcogenide perovskite with promising properties for various energy conversion applications. Recently, sulfurization of oxide precursors has been suggested as a viable solution for effective synthesis, especially from the perspective of circumventing the difficulty of handling alkali earth metals. In this work, we…
▽ More
Barium zirconium sulfide (BaZrS3) is an earth-abundant and environmentally friendly chalcogenide perovskite with promising properties for various energy conversion applications. Recently, sulfurization of oxide precursors has been suggested as a viable solution for effective synthesis, especially from the perspective of circumventing the difficulty of handling alkali earth metals. In this work, we explore in detail the synthesis of BaZrS3 from Ba-Zr-O oxide precursor films sulfurized at temperatures ranging from 700 °C to 1000 °C. We propose a formation mechanism of BaZrS3 based on a two-step reaction involving an intermediate amorphization step of the BaZrO3 crystalline phase. We show how the diffusion of sulfur (S) species in the film is the rate-limiting step of this reaction. The processing temperature plays a key role in determining the total fraction of conversion from oxide to sulfide phase at a constant flow rate of the sulfur-containing H2S gas used as a reactant. Finally, we observe the formation of stoichiometric BaZrS3 (1:1:3), even under Zr-rich precursor conditions, with the formation of ZrO2 as a secondary phase. This marks BaZrS3 quite unique among the other types of chalcogenides, such as chalcopyrites and kesterites, which can instead accommodate quite a large range of non-stoichiometric compositions. This work opens up a pathway for further optimization of the BaZrS3 synthesis process, straightening the route towards future applications of this material.
△ Less
Submitted 13 December, 2022; v1 submitted 27 September, 2022;
originally announced September 2022.
-
The AWAKE Run 2 programme and beyond
Authors:
Edda Gschwendtner,
Konstantin Lotov,
Patric Muggli,
Matthew Wing,
Riccardo Agnello,
Claudia Christina Ahdida,
Maria Carolina Amoedo Goncalves,
Yanis Andrebe,
Oznur Apsimon,
Robert Apsimon,
Jordan Matias Arnesano,
Anna-Maria Bachmann,
Diego Barrientos,
Fabian Batsch,
Vittorio Bencini,
Michele Bergamaschi,
Patrick Blanchard,
Philip Nicholas Burrows,
Birger Buttenschön,
Allen Caldwell,
James Chappell,
Eric Chevallay,
Moses Chung,
David Andrew Cooke,
Heiko Damerau
, et al. (77 additional authors not shown)
Abstract:
Plasma wakefield acceleration is a promising technology to reduce the size of particle accelerators. Use of high energy protons to drive wakefields in plasma has been demonstrated during Run 1 of the AWAKE programme at CERN. Protons of energy 400 GeV drove wakefields that accelerated electrons to 2 GeV in under 10 m of plasma. The AWAKE collaboration is now embarking on Run 2 with the main aims to…
▽ More
Plasma wakefield acceleration is a promising technology to reduce the size of particle accelerators. Use of high energy protons to drive wakefields in plasma has been demonstrated during Run 1 of the AWAKE programme at CERN. Protons of energy 400 GeV drove wakefields that accelerated electrons to 2 GeV in under 10 m of plasma. The AWAKE collaboration is now embarking on Run 2 with the main aims to demonstrate stable accelerating gradients of 0.5-1 GV/m, preserve emittance of the electron bunches during acceleration and develop plasma sources scalable to 100s of metres and beyond. By the end of Run 2, the AWAKE scheme should be able to provide electron beams for particle physics experiments and several possible experiments have already been evaluated. This article summarises the programme of AWAKE Run 2 and how it will be achieved as well as the possible application of the AWAKE scheme to novel particle physics experiments.
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
The CLIC project
Authors:
O. Brunner,
P. N. Burrows,
S. Calatroni,
N. Catalan Lasheras,
R. Corsini,
G. D'Auria,
S. Doebert,
A. Faus-Golfe,
A. Grudiev,
A. Latina,
T. Lefevre,
G. Mcmonagle,
J. Osborne,
Y. Papaphilippou,
A. Robson,
C. Rossi,
R. Ruber,
D. Schulte,
S. Stapnes,
I. Syratchev,
W. Wuensch
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e$^+$e$^-$-collider under development by the CLIC accelerator collaboration, hosted by CERN. The CLIC accelerator has been optimised for three energy stages at centre-of-mass energies 380 GeV, 1.5 TeV and 3 TeV. CLIC uses a novel two-beam acceleration technique, with normal-conducting accelerating structures operating in the…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e$^+$e$^-$-collider under development by the CLIC accelerator collaboration, hosted by CERN. The CLIC accelerator has been optimised for three energy stages at centre-of-mass energies 380 GeV, 1.5 TeV and 3 TeV. CLIC uses a novel two-beam acceleration technique, with normal-conducting accelerating structures operating in the range of 70-100 MV/m.
The report describes recent achievements in accelerator design, technology development and prototyping, system tests and beam tests. Large-scale CLIC-specific beam tests have taken place, for example, at the CLIC Test Facility CTF3 at CERN, at the Accelerator Test Facility ATF2 at KEK, at the FACET facility at SLAC and at the FERMI facility in Trieste. Together, they demonstrate that all implications of the CLIC design parameters are well understood and reproducible in beam tests and prove that the CLIC performance goals are realistic. The implementation of CLIC near CERN has been investigated. Focusing on a staged approach starting at 380 GeV, this includes civil engineering aspects, electrical networks, cooling and ventilation and installation scheduling, transport. All CLIC studies have put emphasis on optimising cost and energy efficiency, and the resulting power and cost estimates are reported. The report follows very closely the accelerator project description in the CLIC Summary Report for the European Particle Physics Strategy update 2018-19.
Detailed studies of the physics potential and detector for CLIC, and R&D on detector technologies, have been carried out by the CLIC detector and physics (CLICdp) collaboration. CLIC provides excellent sensitivity to Beyond Standard Model physics, through direct searches and via a broad set of precision measurements of Standard Model processes, particularly in the Higgs and top-quark sectors.
△ Less
Submitted 18 April, 2022; v1 submitted 17 March, 2022;
originally announced March 2022.
-
Analysis of Proton Bunch Parameters in the AWAKE Experiment
Authors:
V. Hafych,
A. Caldwell,
R. Agnello,
C. C. Ahdida,
M. Aladi,
M. C. Amoedo Goncalves,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
A. Dexter,
S. Doebert
, et al. (63 additional authors not shown)
Abstract:
A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along t…
▽ More
A precise characterization of the incoming proton bunch parameters is required to accurately simulate the self-modulation process in the Advanced Wakefield Experiment (AWAKE). This paper presents an analysis of the parameters of the incoming proton bunches used in the later stages of the AWAKE Run 1 data-taking period. The transverse structure of the bunch is observed at multiple positions along the beamline using scintillating or optical transition radiation screens. The parameters of a model that describes the bunch transverse dimensions and divergence are fitted to represent the observed data using Bayesian inference. The analysis is tested on simulated data and then applied to the experimental data.
△ Less
Submitted 27 September, 2021;
originally announced September 2021.
-
Simulation and Experimental Study of Proton Bunch Self-Modulation in Plasma with Linear Density Gradients
Authors:
P. I. Morales Guzmán,
P. Muggli,
R. Agnello,
C. C. Ahdida,
M. Aladi,
M. C. Amoedo Goncalves,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
F. Braunmüller,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter
, et al. (66 additional authors not shown)
Abstract:
We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported in arXiv:2007.14894v2: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency vari…
▽ More
We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported in arXiv:2007.14894v2: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency varies with gradient. Simulation results show that dephasing of the wakefields with respect to the relativistic protons along the plasma is the main cause for the loss of charge. The study of the modulation frequency reveals details about the evolution of the self-modulation process along the plasma. In particular for negative gradients, the modulation frequency across time-resolved images of the bunch indicates the position along the plasma where protons leave the wakefields. Simulations and experimental results are in excellent agreement.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Human-vector malaria transmission model structured by age, time since infection and waning immunity
Authors:
Quentin Richard,
Marc Choisy,
Thierry Lefèvre,
Ramsès Djidjou-Demasse
Abstract:
In contrast to the many theoretical studies on the transmission of human-mosquitoes malaria infection, few studies have considered a multiple structure model formulations including (i) the chronological age of humans and mosquitoes population, (ii) the time since humans and mosquitoes are infected and (iii) humans waning immunity (i.e., the progressive loss of protective antibodies after recovery)…
▽ More
In contrast to the many theoretical studies on the transmission of human-mosquitoes malaria infection, few studies have considered a multiple structure model formulations including (i) the chronological age of humans and mosquitoes population, (ii) the time since humans and mosquitoes are infected and (iii) humans waning immunity (i.e., the progressive loss of protective antibodies after recovery). Such structural variables are well documented to be fundamental for the transmission of human-mosquitoes malaria infections. Here we formulate an age-structured model accounting for the three structural variables. Using integrated semigroups theory, we first handle the well-posedness of the model proposed. We also investigate the existence of model's steady-states. A disease-free equilibrium always exists while the existence of endemic equilibria is discussed. We derive the threshold R0 (the basic reproduction number). The expression of the R0 obtained here particularly highlight the effect of above structural variables on key important epidemiological traits of the human-vector association. This includes, humans and mosquitoes transmission probability and survival rates. Next, we derive a necessary and sufficient condition that implies the bifurcation of an endemic equilibrium. In some configuration where the age-structure of the human population is neglected, we show that, depending on the sign of some constant Cbif given by the parameters, a bifurcation occurs at R0 = 1 that is either forward or backward. In the former case, it means that there exists a (unique) endemic equilibrium if and only if R0 > 1. In the latter case, no endemic equilibrium exists for R0<< 1 small enough, a unique exists if R0 > 1 while multiple endemic equilibria exist when 0 <<R0 < 1 close enough to 1.
△ Less
Submitted 30 December, 2020;
originally announced December 2020.
-
Transition between Instability and Seeded Self-Modulation of a Relativistic Particle Bunch in Plasma
Authors:
F. Batsch,
P. Muggli,
R. Agnello,
C. C. Ahdida,
M. C. Amoedo Goncalves,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
P. Blanchard,
F. Braunmüller,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
H. L. Deubner,
S. Doebert,
J. Farmer
, et al. (72 additional authors not shown)
Abstract:
We use a relativistic ionization front to provide various initial transverse wakefield amplitudes for the self-modulation of a long proton bunch in plasma. We show experimentally that, with sufficient initial amplitude ($\ge(4.1\pm0.4)$ MV/m), the phase of the modulation along the bunch is reproducible from event to event, with 3 to 7% (of 2$π$) rms variations all along the bunch. The phase is not…
▽ More
We use a relativistic ionization front to provide various initial transverse wakefield amplitudes for the self-modulation of a long proton bunch in plasma. We show experimentally that, with sufficient initial amplitude ($\ge(4.1\pm0.4)$ MV/m), the phase of the modulation along the bunch is reproducible from event to event, with 3 to 7% (of 2$π$) rms variations all along the bunch. The phase is not reproducible for lower initial amplitudes. We observe the transition between these two regimes. Phase reproducibility is essential for deterministic external injection of particles to be accelerated.
△ Less
Submitted 17 December, 2020;
originally announced December 2020.
-
Experimental study of extended timescale dynamics of a plasma wakefield driven by a self-modulated proton bunch
Authors:
J. Chappell,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschön,
A. Caldwell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter,
G. P. Djotyan,
S. Doebert
, et al. (74 additional authors not shown)
Abstract:
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield cau…
▽ More
Plasma wakefield dynamics over timescales up to 800 ps, approximately 100 plasma periods, are studied experimentally at the Advanced Wakefield Experiment (AWAKE). The development of the longitudinal wakefield amplitude driven by a self-modulated proton bunch is measured using the external injection of witness electrons that sample the fields. In simulation, resonant excitation of the wakefield causes plasma electron trajectory crossing, resulting in the development of a potential outside the plasma boundary as electrons are transversely ejected. Trends consistent with the presence of this potential are experimentally measured and their dependence on wakefield amplitude are studied via seed laser timing scans and electron injection delay scans.
△ Less
Submitted 12 October, 2020;
originally announced October 2020.
-
A primary electron beam facility at CERN -- eSPS Conceptual design report
Authors:
M. Aicheler,
T. Akesson,
F. Antoniou,
A. Arnalich,
P. A. Arrutia Sota,
P. Bettencourt Moniz Cabral,
D. Bozzini,
M. Brugger,
O. Brunner,
P. N. Burrows,
R. Calaga,
M. J. Capstick,
R. Corsini,
S. Doebert,
L. A. Dougherty,
Y. Dutheil,
L. A. Dyks,
O. Etisken,
L. Evans,
A. Farricker,
R. Fernandez Ortega,
M. A. Fraser,
J. Gall,
S. J. Gessner,
B. Goddard
, et al. (30 additional authors not shown)
Abstract:
The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron accelerator, and leverages the development invested in Compact Linear Collider (CLIC) technology for its injector and as an accelerator research and development infrastru…
▽ More
The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron accelerator, and leverages the development invested in Compact Linear Collider (CLIC) technology for its injector and as an accelerator research and development infrastructure. The facility would be relevant for several of the key priorities in the 2020 update of the European Strategy for Particle Physics, such as an electron-positron Higgs factory, accelerator R\&D, dark sector physics, and neutrino physics. In addition, it could serve experiments in nuclear physics. The electron beam delivered by this facility would provide access to light dark matter production significantly beyond the targets predicted by a thermal dark matter origin, and for natures of dark matter particles that are not accessible by direct detection experiments. It would also enable electro-nuclear measurements crucial for precise modelling the energy dependence of neutrino-nucleus interactions, which is needed to precisely measure neutrino oscillations as a function of energy. The implementation of the facility is the natural next step in the development of X-band high-gradient acceleration technology, a key technology for compact and cost-effective electron/positron linacs. It would also become the only facility with multi-GeV drive bunches and truly independent electron witness bunches for plasma wakefield acceleration. A second phase capable to deliver positron witness bunches would make it a complete facility for plasma wakefield collider studies. [...]
△ Less
Submitted 21 December, 2020; v1 submitted 15 September, 2020;
originally announced September 2020.
-
Proton beam defocusing in AWAKE: comparison of simulations and measurements
Authors:
A. A. Gorn,
M. Turner,
E. Adli,
R. Agnello,
M. Aladi,
Y. Andrebe,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
M. A. Baistrukov,
F. Batsch,
M. Bergamaschi,
P. Blanchard,
P. N. Burrows,
B. Buttenschon,
A. Caldwell,
J. Chappell,
E. Chevallay,
M. Chung,
D. A. Cooke,
H. Damerau,
C. Davut,
G. Demeter,
L. H. Deubner,
A. Dexter
, et al. (74 additional authors not shown)
Abstract:
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and…
▽ More
In 2017, AWAKE demonstrated the seeded self-modulation (SSM) of a 400 GeV proton beam from the Super Proton Synchrotron (SPS) at CERN. The angular distribution of the protons deflected due to SSM is a quantitative measure of the process, which agrees with simulations by the two-dimensional (axisymmetric) particle-in-cell code LCODE. Agreement is achieved for beam populations between $10^{11}$ and $3 \times 10^{11}$ particles, various plasma density gradients ($-20 ÷20\%$) and two plasma densities ($2\times 10^{14} \text{cm}^{-3}$ and $7 \times 10^{14} \text{cm}^{-3}$). The agreement is reached only in the case of a wide enough simulation box (at least five plasma wavelengths).
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
Polarization and Centre-of-mass Energy Calibration at FCC-ee
Authors:
Alain Blondel,
Patrick Janot,
Jörg Wenninger,
Ralf Aßmann,
Sandra Aumon,
Paolo Azzurri,
Desmond P. Barber,
Michael Benedikt,
Anton V. Bogomyagkov,
Eliana Gianfelice-Wendt,
Dima El Kerchen,
Ivan A. Koop,
Mike Koratzinos,
Evgeni Levitchev,
Thibaut Lefevre,
Attilio Milanese,
Nickolai Muchnoi,
Sergey A. Nikitin,
Katsunobu Oide,
Emmanuel Perez,
Robert Rossmanith,
David C. Sagan,
Roberto Tenchini,
Tobias Tydecks,
Dmitry Shatilov
, et al. (3 additional authors not shown)
Abstract:
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm…
▽ More
The first stage of the FCC (Future Circular Collider) is a high-luminosity electron-positron collider (FCC-ee) with centre-of-mass energy ranging from 88 to 365 GeV, to study with high precision the Z, W, Higgs and top particles, with samples of $5 \times 10^{12}$ Z bosons, $10^8$ W pairs, $10^6$ Higgs bosons and $10^6$ top quark pairs. A cornerstone of the physics program lays in the precise (ppm) measurements of the W and Z masses and widths, as well as forward-backward asymmetries. To this effect the centre-of-mass energy distribution should be determined with the high precision. This document describes the capacity offered by FCC-ee, starting with transverse polarization of the beams around the Z pole and the W pair threshold. A running scheme based on regular measurements of the beam energy by resonant depolarization of pilot bunches, during physics data taking, is proposed. The design for polarization wigglers, polarimeter and depolarizer is outlined. The $e^\pm$ beam energies will be monitored with a relative precision of $10^{-6}$. The centre-of-mass energy is derived subject to further corrections, related to the beam acceleration, synchrotron radiation and beamstrahlung; these effects are identified and evaluated. Dimuon events $e^+e^- \to μ^+ μ^-$, recorded in the detectors, provide with great precision the beam crossing angle, the centre-of-mass energy spread, and the $e^+$ and $e^-$ energy difference. Monitoring methods to minimize absolute error and relative uncertainties are discussed. The impact on the physics measurements is given. A programme of further simulations, design, monitoring and R&D is outlined.
△ Less
Submitted 26 September, 2019;
originally announced September 2019.
-
Gamma Factory at CERN -- novel research tools made of light
Authors:
W. Placzek,
A. Abramov,
S. E. Alden,
R. Alemany Fernandez,
P. S. Antsiferov,
A. Apyan,
H. Bartosik,
E. G. Bessonov,
N. Biancacci,
J. Bieron,
A. Bogacz,
A. Bosco,
R. Bruce,
D. Budker,
K. Cassou,
F. Castelli,
I. Chaikovska,
C. Curatolo,
P. Czodrowski,
A. Derevianko,
K. Dupraz,
Y. Dutheil,
K. Dzierzega,
V. Fedosseev,
N. Fuster Martinez
, et al. (37 additional authors not shown)
Abstract:
We discuss the possibility of creating novel research tools by producing and storing highly relativistic beams of highly ionised atoms in the CERN accelerator complex, and by exciting their atomic degrees of freedom with lasers to produce high-energy photon beams. Intensity of such photon beams would be by several orders of magnitude higher than offered by the presently operating light sources, in…
▽ More
We discuss the possibility of creating novel research tools by producing and storing highly relativistic beams of highly ionised atoms in the CERN accelerator complex, and by exciting their atomic degrees of freedom with lasers to produce high-energy photon beams. Intensity of such photon beams would be by several orders of magnitude higher than offered by the presently operating light sources, in the particularly interesting gamma-ray energy domain of 0.1-400 MeV. In this energy range, the high-intensity photon beams can be used to produce secondary beams of polarised electrons, polarised positrons, polarised muons, neutrinos, neutrons and radioactive ions. New research opportunities in a wide domain of fundamental and applied physics can be opened by the Gamma Factory scientific programme based on the above primary and secondary beams.
△ Less
Submitted 14 June, 2019; v1 submitted 21 March, 2019;
originally announced March 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Experimental observation of proton bunch modulation in a plasma, at varying plasma densities
Authors:
E. Adli,
A. Ahuja,
O. Apsimon,
R. Apsimon,
A. -M. Bachmann,
D. Barrientos,
M. M. Barros,
J. Batkiewicz,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmüller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschön,
A. Caldwell,
M. Cascella,
J. Chappell
, et al. (87 additional authors not shown)
Abstract:
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the…
▽ More
We give direct experimental evidence for the observation of the full transverse self-modulation of a relativistic proton bunch propagating through a dense plasma. The bunch exits the plasma with a density modulation resulting from radial wakefield effects with a period reciprocal to the plasma frequency. We show that the modulation is seeded by using an intense laser pulse co-propagating with the proton bunch which creates a relativistic ionization front within the bunch. We show by varying the plasma density over one order of magnitude that the modulation period scales with the expected dependence on the plasma density.
△ Less
Submitted 1 April, 2019; v1 submitted 12 September, 2018;
originally announced September 2018.
-
AWAKE readiness for the study of the seeded self-modulation of a 400\,GeV proton bunch
Authors:
P. Muggli,
E. Adli,
R. Apsimon,
F. Asmus,
R. Baartman,
A. -M. Bachmann,
M. Barros Marin,
F. Batsch,
J. Bauche,
V. K. Berglyd Olsen,
M. Bernardini,
B. Biskup,
A. Boccardi,
T. Bogey,
T. Bohl,
C. Bracco,
F. Braunmuller,
S. Burger,
G. Burt,
S. Bustamante,
B. Buttenschon,
A. Butterworth,
A. Caldwell,
M. Cascella,
E. Chevallay
, et al. (82 additional authors not shown)
Abstract:
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propag…
▽ More
AWAKE is a proton-driven plasma wakefield acceleration experiment. % We show that the experimental setup briefly described here is ready for systematic study of the seeded self-modulation of the 400\,GeV proton bunch in the 10\,m-long rubidium plasma with density adjustable from 1 to 10$\times10^{14}$\,cm$^{-3}$. % We show that the short laser pulse used for ionization of the rubidium vapor propagates all the way along the column, suggesting full ionization of the vapor. % We show that ionization occurs along the proton bunch, at the laser time and that the plasma that follows affects the proton bunch. %
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Making the best of data derived from a daily practice in clinical legal medicine for research and practice - the example of Spe3dLab
Authors:
Vincent Laugier,
Eric Stindel,
Alcibiade Lichterowicz,
Séverine Ansart,
Thomas Lefèvre
Abstract:
Forensic science suffers from a lack of studies with high-quality design, such as randomized controlled trials (RCT). Evidence in forensic science may be of insufficient quality, which is a major concern. Results from RCT are criticized for providing artificial results that are not useful in real life and unfit for individualized prescription. Various sources of collected data (e.g. data collected…
▽ More
Forensic science suffers from a lack of studies with high-quality design, such as randomized controlled trials (RCT). Evidence in forensic science may be of insufficient quality, which is a major concern. Results from RCT are criticized for providing artificial results that are not useful in real life and unfit for individualized prescription. Various sources of collected data (e.g. data collected in routine practice) could be exploited for distinct goals. Obstacles remain before such data can be practically accessed and used, including technical issues. We present an easy-to-use software dedicated to innovative data analyses for practitioners and researchers. We provide 2 examples in forensics. Spe3dLab has been developed by 3 French teams: a bioinformatics laboratory (LaTIM), a private partner (Tekliko) and a department of forensic medicine (Jean Verdier Hospital). It was designed to be open source, relying on documented and maintained libraries, query-oriented and capable of handling the entire data process from capture to export of best predictive models for their integration in information systems. Spe3dLab was used for 2 specific forensics applications: i) the search for multiple causal factors and ii) the best predictive model of the functional impairment (total incapacity to work, TIW) of assault survivors. 2,892 patients were included over a 6-month period. Time to evaluation was the only direct cause identified for TIW, and victim category was an indirect cause. The specificity and sensitivity of the predictive model were 99.9% and 90%, respectively. Spe3dLab is a quick and efficient tool for accessing observational, routinely collected data and performing innovative analyses. Analyses can be exported for validation and routine use by practitioners, e.g., for computer-aided evaluation of complex problems. It can provide a fully integrated solution for individualized medicine.
△ Less
Submitted 26 July, 2017;
originally announced July 2017.
-
Beam Instrumentation and Long-Range Beam-Beam Compensation
Authors:
E. Bravin,
B. Dehning,
R. Jones,
T. Lefevre,
H. Schmickler
Abstract:
Chapter 13 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme tempe…
▽ More
Chapter 13 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.
△ Less
Submitted 26 May, 2017;
originally announced May 2017.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Introduction to Beam Instrumentation and Diagnostics
Authors:
M. Gasior,
R. Jones,
T. Lefevre,
H. Schmickler,
K. Wittenburg
Abstract:
These lectures aim to describe instruments and methods used for measuring beam parameters in particle accelerators. Emphasis will be given to new detection and analysis techniques in each field of accelerator instrumentation. A clear distinction is made between 'instrumentation', the design and construction of the instruments themselves, and 'diagnostics', the use of the data from these instrument…
▽ More
These lectures aim to describe instruments and methods used for measuring beam parameters in particle accelerators. Emphasis will be given to new detection and analysis techniques in each field of accelerator instrumentation. A clear distinction is made between 'instrumentation', the design and construction of the instruments themselves, and 'diagnostics', the use of the data from these instruments for running and improving the performance of the accelerator.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Laser Wire Scanner Compton Scattering Techniques for the Measurement of the Transverse Beam Size of Particle Beams at Future Linear Colliders
Authors:
I. Agapov,
K. Baleski,
G. A. Blair,
J. Bosser,
H. H. Braun,
E. Bravin,
G. Boorman,
S. T. Boogert,
J. Carter,
E. D'amico,
N. Delerue,
D. F. Howell,
S. Doebert,
C. Driouichi,
J. Frisch,
K. Honkavaaram S. Hutchins,
T. Kamps,
T. Lefevre,
H. Lewin,
T. Paris,
F. Poirier,
M. T. Price,
R. Maccaferi,
S. Malton,
G. Penn
, et al. (9 additional authors not shown)
Abstract:
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
This archive summarizes a working paper and conference proceedings related to laser wire scanner development for the Future Linear Collider (FLC) in the years 2001 to 2006. In particular the design, setup and data taking for the laser wire experiments at PETRA II and CT2 are described. The material is focused on the activities undertaken by Royal Holloway University of London (RHUL).
△ Less
Submitted 9 December, 2014;
originally announced December 2014.
-
Status of the ILC Main Linac BPM R&D
Authors:
M. Wendt,
T. Lefevre,
C. Simon,
S. Vilalte
Abstract:
An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant reso…
▽ More
An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).
△ Less
Submitted 17 February, 2009;
originally announced February 2009.
-
Analysis of longitudinal bunching inan FEL driven two-beam accelerator
Authors:
S. Lidia,
J. Gardelle,
T. Lefevre,
J. T. Donohue,
P. Gouard,
J. L. Rullier,
C. Vermare
Abstract:
Recent experiments [1] have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here we present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, we examine the effect of t…
▽ More
Recent experiments [1] have explored the use of a free-electron laser (FEL) as a buncher for a microwave two-beam accelerator, and the subsequent driving of a standing-wave rf output cavity. Here we present a deeper analysis of the longitudinal dynamics of the electron bunches as they are transported from the end of the FEL and through the output cavity. In particular, we examine the effect of the transport region and cavity aperture to filter the bunched portion of the beam.
[1] T. Lefevre, et. al., Phys. Rev. Lett. 84 (2000), 1188.
△ Less
Submitted 17 August, 2000;
originally announced August 2000.