-
Quantum noise cancellation in asymmetric speed meters with balanced homodyne readout
Authors:
T Zhang,
E Knyazev,
S Steinlechner,
F Ya Khalili,
B W Barr,
A S Bell,
P Dupej,
C Gräf,
J Callaghan,
J S Hennig,
E A Houston,
S H Huttner,
S S Leavey,
D Pascucci,
B Sorazu,
A Spencer,
J Wright,
K A Strain,
S L Danilishin,
S Hild
Abstract:
Sagnac speed meter (SSM) topology is known as an alternative technique to reduce quantum back-action in gravitational-wave interferometers. However, any potential imbalance of the main beamsplitter was shown to reduce the quantum noise superiority of speed meter at low frequencies, caused due to increased laser noise coupling to the detection port. In this paper, we show that implementing balanced…
▽ More
Sagnac speed meter (SSM) topology is known as an alternative technique to reduce quantum back-action in gravitational-wave interferometers. However, any potential imbalance of the main beamsplitter was shown to reduce the quantum noise superiority of speed meter at low frequencies, caused due to increased laser noise coupling to the detection port. In this paper, we show that implementing balanced homodyne readout scheme and for a particular choice of the local oscillator (LO) delivery port, the excess laser noise contribution to quantum noise limited sensitivity (QNLS) is partly compensated and the speed meter sensitivity can outperform state-of-the-art position meters. This can be achieved by picking the local oscillator from interferometer reflection (\textit{co-moving} LO) or the main beamsplitter anti-reflective coating surface (BSAR LO). We also show that this relaxes the relative intensity noise (RIN) requirement of the input laser. For example, for a beam splitter imbalance of $0.1 \%$ in Glasgow speed meter proof of concept experiment, the RIN requirement at frequency of 100Hz decreases from $4\times 10^{-10}/\sqrt{\rm Hz}$ to $4\times 10^{-7}/\sqrt{\rm Hz}$, moving the RIN requirement from a not practical achievable value to one which is routinely achieved with moderate effort.
△ Less
Submitted 14 June, 2018;
originally announced June 2018.
-
Demonstration of a switchable damping system to allow low-noise operation of high-Q low-mass suspension systems
Authors:
Jan-Simon Hennig,
Bryan W. Barr,
Angus S. Bell,
William Cunningham,
Stefan L. Danilishin,
Peter Dupej,
Christian Graef,
Sabina H. Huttner,
Russell Jones,
Sean S. Leavey,
Daniela Pascucci,
Martin Sinclair,
Borja Sorazu,
Andrew Spencer,
Sebastian Steinlechner,
Kenneth A. Strain,
Jennifer Wright,
Teng Zhang,
Stefan Hild
Abstract:
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementa…
▽ More
Low mass suspension systems with high-Q pendulum stages are used to enable quantum radiation pressure noise limited experiments. Utilising multiple pendulum stages with vertical blade springs and materials with high quality factors provides attenuation of seismic and thermal noise, however damping of these high-Q pendulum systems in multiple degrees of freedom is essential for practical implementation. Viscous damping such as eddy-current damping can be employed but introduces displacement noise from force noise due to thermal fluctuations in the damping system. In this paper we demonstrate a passive damping system with adjustable damping strength as a solution for this problem that can be used for low mass suspension systems without adding additional displacement noise in science mode. We show a reduction of the damping factor by a factor of 8 on a test suspension and provide a general optimisation for this system.
△ Less
Submitted 25 October, 2017; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Effects of static and dynamic higher-order optical modes in balanced homodyne readout for future gravitational waves detectors
Authors:
Teng Zhang,
Stefan L Danilishin,
Sebastian Steinlechner,
Bryan W Barr,
Angus S Bell,
Peter Dupej,
Christian Gräf,
Jan-Simon Hennig,
E Alasdair Houston,
Sabina H Huttner,
Sean S Leavey,
Daniela Pascucci,
Borja Sorazu,
Andrew Spencer,
Jennifer Wright,
Kenneth A Strain,
Stefan Hild
Abstract:
With the recent discovery of Gravitational waves, marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for u…
▽ More
With the recent discovery of Gravitational waves, marking the start of the new field of GW astronomy, the push for building more sensitive laser-interferometric gravitational wave detectors (GWD) has never been stronger. Balanced homodyne detection (BHD) allows for a quantum noise limited readout of arbitrary light field quadratures, and has therefore been suggested as a vital building block for upgrades to Advanced LIGO and third generation observatories. In terms of the practical implementation of BHD, we develop a full framework for analyzing the static optical high order modes (HOMs) occurring in the BHD paths related to the misalignment or mode matching at the input and output ports of the laser interferometer. We find the effects of HOMs on the quantum noise limited sensitivity is independent of the actual interferometer configuration, e.g. Michelson and Sagnac interferometers are effected in the same way. We show that output misalignment only effects the high frequency part of the quantum noise limited sensitivity. However, at low frequencies, HOMs reduce the interferometer response and the radiation pressure noise by the same amount and hence the quantum noise limited sensitivity is not negatively effected. We show that the input misalignment to the interferometer produces the same effect as output misalignment and additionally decreases the power inside the interferometer. We also analyze dynamic HOM effects, such as beam jitter created by the suspended mirrors of the BHD. Our analyses can be directly applied to any BHD implementation in a future GWD. Moreover, we apply our analytical techniques to the example of the speed meter proof of concept experiment under construction in Glasgow. We find that for our experimental parameters, the performance of our seismic isolation system in the BHD paths is compatible with the design sensitivity of the experiment.
△ Less
Submitted 2 February, 2017; v1 submitted 2 December, 2016;
originally announced December 2016.
-
Control of a velocity-sensitive audio-band quantum non-demolition interferometer
Authors:
S. S. Leavey,
S. L. Danilishin,
A. Gläfke,
B. W. Barr,
A. S. Bell,
C. Gräf,
J. -S. Hennig,
E. A. Houston,
S. H. Huttner,
H. Lück,
D. Pascucci,
K. Somiya,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
J. Wright,
T. Zhang,
S. Hild
Abstract:
The Sagnac speed meter interferometer topology can potentially provide enhanced sensitivity to gravitational waves in the audio-band compared to equivalent Michelson interferometers. A challenge with the Sagnac speed meter interferometer arises from the intrinsic lack of sensitivity at low frequencies where the velocity-proportional signal is smaller than the noise associated with the sensing of t…
▽ More
The Sagnac speed meter interferometer topology can potentially provide enhanced sensitivity to gravitational waves in the audio-band compared to equivalent Michelson interferometers. A challenge with the Sagnac speed meter interferometer arises from the intrinsic lack of sensitivity at low frequencies where the velocity-proportional signal is smaller than the noise associated with the sensing of the signal. Using as an example the on-going proof-of-concept Sagnac speed meter experiment in Glasgow, we quantify the problem and present a solution involving the extraction of a small displacement-proportional signal. This displacement signal can be combined with the existing velocity signal to enhance low frequency sensitivity, and we derive optimal filters to accomplish this for different signal strengths. We show that the extraction of the displacement signal for low frequency control purposes can be performed without reducing significantly the quantum non-demolition character of this type of interferometer.
△ Less
Submitted 24 March, 2016;
originally announced March 2016.
-
Local-Oscillator Noise Coupling in Balanced Homodyne Readout for Advanced Gravitational Wave Detectors
Authors:
Sebastian Steinlechner,
Bryan W Barr,
Angus S Bell,
Stefan L Danilishin,
Andreas Gläfke,
Christian Gräf,
Jan-Simon Hennig,
E Alasdair Houston,
Sabina H Huttner,
Sean S Leavey,
Daniela Pascucci,
Borja Sorazu,
Andrew Spencer,
Kenneth A Strain,
Jennifer Wright,
Stefan Hild
Abstract:
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature…
▽ More
The second generation of interferometric gravitational wave detectors are quickly approaching their design sensitivity. For the first time these detectors will become limited by quantum back-action noise. Several back-action evasion techniques have been proposed to further increase the detector sensitivity. Since most proposals rely on a flexible readout of the full amplitude- and phase-quadrature space of the output light field, balanced homodyne detection is generally expected to replace the currently used DC readout. Up to now, little investigation has been undertaken into how balanced homodyne detection can be successfully transferred from its ubiquitous application in table-top quantum optics experiments to large-scale interferometers with suspended optics. Here we derive implementation requirements with respect to local oscillator noise couplings and highlight potential issues with the example of the Glasgow Sagnac Speed Meter experiment, as well as for a future upgrade to the Advanced LIGO detectors.
△ Less
Submitted 24 June, 2015;
originally announced June 2015.
-
Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries
Authors:
S. L. Danilishin,
C. Graef,
S. S. Leavey,
J. Hennig,
E. A. Houston,
D. Pascucci,
S. Steinlechner,
J. Wright,
S. Hild
Abstract:
The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity tha…
▽ More
The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.
△ Less
Submitted 19 February, 2015; v1 submitted 2 December, 2014;
originally announced December 2014.
-
Design of a speed meter interferometer proof-of-principle experiment
Authors:
C. Gräf,
B. W. Barr,
A. S. Bell,
F. Campbell,
A. V. Cumming,
S. L. Danilishin,
N. A. Gordon,
G. D. Hammond,
J. Hennig,
E. A. Houston,
S. H. Huttner,
R. A. Jones,
S. S. Leavey,
H. Lück,
J. Macarthur,
M. Marwick,
S. Rigby,
R. Schilling,
B. Sorazu,
A. Spencer,
S. Steinlechner,
K. A. Strain,
S. Hild
Abstract:
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of develo…
▽ More
The second generation of large scale interferometric gravitational wave detectors will be limited by quantum noise over a wide frequency range in their detection band. Further sensitivity improvements for future upgrades or new detectors beyond the second generation motivate the development of measurement schemes to mitigate the impact of quantum noise in these instruments. Two strands of development are being pursued to reach this goal, focusing both on modifications of the well-established Michelson detector configuration and development of different detector topologies. In this paper, we present the design of the world's first Sagnac speed meter interferometer which is currently being constructed at the University of Glasgow. With this proof-of-principle experiment we aim to demonstrate the theoretically predicted lower quantum noise in a Sagnac interferometer compared to an equivalent Michelson interferometer, to qualify Sagnac speed meters for further research towards an implementation in a future generation large scale gravitational wave detector, such as the planned Einstein Telescope observatory.
△ Less
Submitted 11 September, 2014; v1 submitted 12 May, 2014;
originally announced May 2014.