-
Diffusion pore imaging in the presence of extraporal water
Authors:
Dominik Ludwig,
Frederik Bernd Laun,
Karel D. Klika,
Julian Rauch,
Mark Edward Ladd,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far…
▽ More
Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure.
More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far, artificial systems have been used for experimental demonstration without extraporal signal components and relatively low gradient amplitudes.
Therefore, the aim of this study was to investigate the feasibility of diffusion pore imaging in the presence of extraporal fluids and to develop correction methods for effects arising from extraporal signal contributions. Monte Carlo simulations and validation experiments on a 14.1 T spectrometer with a dedicated diffusion probe head were performed.
Both by using a filter gradient approach suppressing extraporal signal components as well as using postprocessing methods relying on the Gaussian phase approximation, it was possible to reconstruct pore space functions in the presence of extraporal fluids with little to no deviations from the expectations. These results may be a significant step towards application of diffusion pore imaging to biological samples. While still ultra-high gradients are required, this problem may be mitigated by recent developments in the field of local gradient coils for human applications.
△ Less
Submitted 10 October, 2021;
originally announced October 2021.
-
NeXtQSM -- A complete deep learning pipeline for data-consistent quantitative susceptibility mapping trained with hybrid data
Authors:
Francesco Cognolato,
Kieran O'Brien,
Jin Jin,
Simon Robinson,
Frederik B. Laun,
Markus Barth,
Steffen Bollmann
Abstract:
Deep learning based Quantitative Susceptibility Mapping (QSM) has shown great potential in recent years, obtaining similar results to established non-learning approaches. Many current deep learning approaches are not data consistent, require in vivo training data or solve the QSM problem in consecutive steps resulting in the propagation of errors. Here we aim to overcome these limitations and deve…
▽ More
Deep learning based Quantitative Susceptibility Mapping (QSM) has shown great potential in recent years, obtaining similar results to established non-learning approaches. Many current deep learning approaches are not data consistent, require in vivo training data or solve the QSM problem in consecutive steps resulting in the propagation of errors. Here we aim to overcome these limitations and developed a framework to solve the QSM processing steps jointly. We developed a new hybrid training data generation method that enables the end-to-end training for solving background field correction and dipole inversion in a data-consistent fashion using a variational network that combines the QSM model term and a learned regularizer. We demonstrate that NeXtQSM overcomes the limitations of previous deep learning methods. NeXtQSM offers a new deep learning based pipeline for computing quantitative susceptibility maps that integrates each processing step into the training and provides results that are robust and fast.
△ Less
Submitted 30 August, 2023; v1 submitted 16 July, 2021;
originally announced July 2021.
-
NMR diffusion pore imaging: Experimental phase detection by double diffusion encoding
Authors:
Kerstin Demberg,
Frederik Bernd Laun,
Johannes Windschuh,
Reiner Umathum,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
Diffusion pore imaging is an extension of diffusion-weighted nuclear magnetic resonance imaging enabling the direct measurement of the shape of arbitrarily formed, closed pores by probing diffusion restrictions using the motion of spin-bearing particles. Examples of such pores comprise cells in biological tissue or oil containing cavities in porous rocks. All pores contained in the measurement vol…
▽ More
Diffusion pore imaging is an extension of diffusion-weighted nuclear magnetic resonance imaging enabling the direct measurement of the shape of arbitrarily formed, closed pores by probing diffusion restrictions using the motion of spin-bearing particles. Examples of such pores comprise cells in biological tissue or oil containing cavities in porous rocks. All pores contained in the measurement volume contribute to one reconstructed image, which reduces the problem of vanishing signal at increasing resolution present in conventional magnetic resonance imaging. It has been previously experimentally demonstrated that pore imaging using a combination of a long and a narrow magnetic field gradient pulse is feasible. In this work, an experimental verification is presented showing that pores can be imaged using short gradient pulses only. Experiments were carried out using hyperpolarized xenon gas in well-defined pores. The phase required for pore image reconstruction was retrieved from double diffusion encoded (DDE) measurements, while the magnitude could either be obtained from DDE signals or classical diffusion measurements with single encoding. The occurring image artifacts caused by restrictions of the gradient system, insufficient diffusion time, and by the phase reconstruction approach were investigated. Employing short gradient pulses only is advantageous compared to the initial long-narrow approach due to a more flexible sequence design when omitting the long gradient and due to faster convergence to the diffusion long-time limit, which may enable application to larger pores.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
Experimental determination of pore shapes using phase retrieval from q-space NMR diffraction
Authors:
Kerstin Demberg,
Frederik Bernd Laun,
Marco Bertleff,
Peter Bachert,
Tristan Anselm Kuder
Abstract:
This paper presents a novel approach on solving the phase problem in nuclear magnetic resonance (NMR) diffusion pore imaging, a method, which allows imaging the shape of arbitrary closed pores filled with an NMR-detectable medium for investigation of the microstructure of biological tissue and porous materials. Classical q-space imaging composed of two short diffusion-encoding gradient pulses yiel…
▽ More
This paper presents a novel approach on solving the phase problem in nuclear magnetic resonance (NMR) diffusion pore imaging, a method, which allows imaging the shape of arbitrary closed pores filled with an NMR-detectable medium for investigation of the microstructure of biological tissue and porous materials. Classical q-space imaging composed of two short diffusion-encoding gradient pulses yields, analogously to diffraction experiments, the modulus squared of the Fourier transform of the pore image which entails an inversion problem: An unambiguous reconstruction of the pore image requires both magnitude and phase. Here, the phase information is recovered from the Fourier modulus by applying a phase retrieval algorithm. This allows omitting experimentally challenging phase measurements using specialized temporal gradient profiles. A combination of the hybrid input-output algorithm and the error reduction algorithm was used with dynamically adapting support (shrinkwrap extension). No a priori knowledge on the pore shape was fed to the algorithm except for a finite pore extent. The phase retrieval approach proved successful for simulated data with and without noise and was validated in phantom experiments with well-defined pores using hyperpolarized xenon gas.
△ Less
Submitted 6 May, 2021;
originally announced May 2021.
-
On the field strength dependence of bi- and triexponential intravoxel incoherent motion (IVIM) parameters in the liver
Authors:
Andreas Julian Riexinger,
Jan Martin,
Susanne Rauh,
Andreas Wetscherek,
Mona Pistel,
Tristan Anselm Kuder,
Armin Michael Nagel,
Michael Uder,
Bernhard Hensel,
Lars Müller,
Frederik Bernd Laun
Abstract:
Background: Studies on intravoxel incoherent motion (IVIM) imaging are carried out with different acquisition protocols. Purpose: Investigate the dependence of IVIM parameters on the B_0field strength when using a bi- or triexponential model. Field Strength/Sequence: 20 volunteers were examined at two field strengths (1.5 and 3T). Diffusion-weighted images of the abdomen were acquired at 24 b-valu…
▽ More
Background: Studies on intravoxel incoherent motion (IVIM) imaging are carried out with different acquisition protocols. Purpose: Investigate the dependence of IVIM parameters on the B_0field strength when using a bi- or triexponential model. Field Strength/Sequence: 20 volunteers were examined at two field strengths (1.5 and 3T). Diffusion-weighted images of the abdomen were acquired at 24 b-values ranging from 0.2 to 500 s/mm2. Assessment: ROIs were manually drawn in the liver. Data were fitted with a bi- and a triexponential IVIM model. Resulting parameters were compared between both field strengths. Results: At b-values below 6s/mm2, the triexponential model provided better agreement with the data than the biexponential model. The average tissue diffusivity was D=1.22/1.00 um/ms at 1.5/3T. The average pseudo-diffusion coefficients for the biexponential model were D*=308/260um/ms at 1.5/3T; and for the triexponential model D1*=81.3/65.9um/ms , D2*=2453/2333um/ms at 1.5/3T. The average perfusion fractions for the biexponential model were f=0.286/0.303 at 1.5/3T; and for the triexponential model f1=0.161/0.174 and f2=0.152/0.159 at 1.5/3T. A significant B0 dependence was only found for the biexponential pseudo-diffusion coefficient (ANOVA/KW p=0.037/0.0453) and tissue diffusivity (ANOVA/KW: p<0.001). Conclusion: Our experimental results suggest that triexponential pseudo-diffusion coefficients and perfusion fractions obtained at different field strengths could be compared across different studies using different B0. However, it is recommendable to take the field strength into account when comparing tissue diffusivities or using the biexponential IVIM model. Considering published values for oxygenation-dependent transversal relaxation times of blood, it is unlikely that the two blood compartments of the triexponential model represent venous and arterial blood.
△ Less
Submitted 4 May, 2021;
originally announced May 2021.
-
Eddy current compensated double diffusion encoded (DDE) MRI
Authors:
Lars Mueller,
Andreas Wetscherek,
Tristan Anselm Kuder,
Frederik Bernd Laun
Abstract:
Purpose: Eddy currents might lead to image distortions in diffusion weighted echo planar imaging. A method is proposed to reduce their effects on double diffusion encoding (DDE) MRI experiments and the thereby derived microscopic fractional anisotropy (μFA) . Methods: The twice refocused spin echo scheme was adapted for DDE measurements. To assess the effect of individual diffusion encodings on th…
▽ More
Purpose: Eddy currents might lead to image distortions in diffusion weighted echo planar imaging. A method is proposed to reduce their effects on double diffusion encoding (DDE) MRI experiments and the thereby derived microscopic fractional anisotropy (μFA) . Methods: The twice refocused spin echo scheme was adapted for DDE measurements. To assess the effect of individual diffusion encodings on the image distortions, measurements of a grid of plastic rods in water were performed. The effect of eddy current compensation on μFA measurements was evaluated in the brains of six healthy volunteers. Results: The use of an eddy current compensation reduced the signal variation. As expected, the distortions caused by the second encoding were larger than those of the first encoding entailing a stronger need to compensate for them. For an optimal result, however, both encodings had to be compensated. The artifact reduction strongly improved the measurement of the μFA in ventricles and grey matter by reducing the overestimation. An effect of the compensation on absolute μFA values in white matter was not observed. Conclusion: It is advisable to compensate both encodings in DDE measurements for eddy currents.
△ Less
Submitted 18 April, 2021;
originally announced April 2021.
-
Contrast-to-noise ratio analysis of microscopic diffusion anisotropy indices in q-space trajectory imaging
Authors:
Jan Martin,
Sebastian Endt,
Andreas Wetscherek,
Tristan Anselm Kuder,
Arnd Doerfler,
Michael Uder,
Bernhard Hensel,
Frederik Bernd Laun
Abstract:
Diffusion anisotropy in diffusion tensor imaging (DTI) is commonly quantified with normalized diffusion anisotropy indices (DAIs). Most often, the fractional anisotropy (FA) is used, but several alternative DAIs have been introduced in attempts to maximize the contrast-to-noise ratio (CNR) in diffusion anisotropy maps. Examples include the scaled relative anisotropy (sRA), the gamma variate anisot…
▽ More
Diffusion anisotropy in diffusion tensor imaging (DTI) is commonly quantified with normalized diffusion anisotropy indices (DAIs). Most often, the fractional anisotropy (FA) is used, but several alternative DAIs have been introduced in attempts to maximize the contrast-to-noise ratio (CNR) in diffusion anisotropy maps. Examples include the scaled relative anisotropy (sRA), the gamma variate anisotropy index (GV), the surface anisotropy (UAsurf), and the lattice index (LI). With the advent of multidimensional diffusion encoding it became possible to determine the presence of microscopic diffusion anisotropy in a voxel, which is theoretically independent of orientation coherence. In accordance with DTI, the microscopic anisotropy is typically quantified by the microscopic fractional anisotropy (uFA). In this work, in addition to the uFA, the four microscopic diffusion anisotropy indices (uDAIs) usRA, uGV, uUAsurf, and uLI are defined in analogy to the respective DAIs by means of the average diffusion tensor and the covariance tensor. Simulations with three representative distributions of microscopic diffusion tensors revealed distinct CNR differences when differentiating between isotropic and microscopically anisotropic diffusion. q-Space trajectory imaging (QTI) was employed to acquire brain in-vivo maps of all indices. For this purpose, a 15 min protocol featuring linear, planar, and spherical tensor encoding was used. The resulting maps were of good quality and exhibited different contrasts, e.g. between gray and white matter. This indicates that it may be beneficial to use more than one uDAI in future investigational studies.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Domain Adaptation for Deviating Acquisition Protocols in CNN-based Lesion Classification on Diffusion-Weighted MR Images
Authors:
Jennifer Kamphenkel,
Paul F. Jaeger,
Sebastian Bickelhaupt,
Frederik Bernd Laun,
Wolfgang Lederer,
Heidi Daniel,
Tristan Anselm Kuder,
Stefan Delorme,
Heinz-Peter Schlemmer,
Franziska Koenig,
Klaus H. Maier-Hein
Abstract:
End-to-end deep learning improves breast cancer classification on diffusion-weighted MR images (DWI) using a convolutional neural network (CNN) architecture. A limitation of CNN as opposed to previous model-based approaches is the dependence on specific DWI input channels used during training. However, in the context of large-scale application, methods agnostic towards heterogeneous inputs are des…
▽ More
End-to-end deep learning improves breast cancer classification on diffusion-weighted MR images (DWI) using a convolutional neural network (CNN) architecture. A limitation of CNN as opposed to previous model-based approaches is the dependence on specific DWI input channels used during training. However, in the context of large-scale application, methods agnostic towards heterogeneous inputs are desirable, due to the high deviation of scanning protocols between clinical sites. We propose model-based domain adaptation to overcome input dependencies and avoid re-training of networks at clinical sites by restoring training inputs from altered input channels given during deployment. We demonstrate the method's significant increase in classification performance and superiority over implicit domain adaptation provided by training-schemes operating on model-parameters instead of raw DWI images.
△ Less
Submitted 17 July, 2018;
originally announced July 2018.
-
Revealing Hidden Potentials of the q-Space Signal in Breast Cancer
Authors:
Paul Jaeger,
Sebastian Bickelhaupt,
Frederik Bernd Laun,
Wolfgang Lederer,
Daniel Heidi,
Tristan Anselm Kuder,
Daniel Paech,
David Bonekamp,
Alexander Radbruch,
Stefan Delorme,
Heinz-Peter Schlemmer,
Franziska Steudle,
Klaus H. Maier-Hein
Abstract:
Mammography screening for early detection of breast lesions currently suffers from high amounts of false positive findings, which result in unnecessary invasive biopsies. Diffusion-weighted MR images (DWI) can help to reduce many of these false-positive findings prior to biopsy. Current approaches estimate tissue properties by means of quantitative parameters taken from generative, biophysical mod…
▽ More
Mammography screening for early detection of breast lesions currently suffers from high amounts of false positive findings, which result in unnecessary invasive biopsies. Diffusion-weighted MR images (DWI) can help to reduce many of these false-positive findings prior to biopsy. Current approaches estimate tissue properties by means of quantitative parameters taken from generative, biophysical models fit to the q-space encoded signal under certain assumptions regarding noise and spatial homogeneity. This process is prone to fitting instability and partial information loss due to model simplicity. We reveal unexplored potentials of the signal by integrating all data processing components into a convolutional neural network (CNN) architecture that is designed to propagate clinical target information down to the raw input images. This approach enables simultaneous and target-specific optimization of image normalization, signal exploitation, global representation learning and classification. Using a multicentric data set of 222 patients, we demonstrate that our approach significantly improves clinical decision making with respect to the current state of the art.
△ Less
Submitted 22 May, 2017; v1 submitted 27 February, 2017;
originally announced February 2017.
-
NMR-Based Diffusion Lattice Imaging
Authors:
Frederik Bernd Laun,
Tristan Anselm Kuder
Abstract:
Nuclear magnetic resonance (NMR) diffusion experiments are widely employed as they yield information about structures hindering the diffusion process, e.g. about cell membranes. While it has been shown in recent articles, that these experiments can be used to determine the exact shape of closed pores averaged over a volume of interest, it is still an open question how much information can be gaine…
▽ More
Nuclear magnetic resonance (NMR) diffusion experiments are widely employed as they yield information about structures hindering the diffusion process, e.g. about cell membranes. While it has been shown in recent articles, that these experiments can be used to determine the exact shape of closed pores averaged over a volume of interest, it is still an open question how much information can be gained in open systems. In this theoretical work, we show that the full structure information of periodic open systems is accessible. To this end, the so-called 'SEquential Rephasing by Pulsed field-gradient Encoding N Time-intervals' (SERPENT) sequence is used, which employs several diffusion weighting gradient pulses with different amplitudes. The structural information is obtained by an iterative technique relying on a Gaussian envelope model of the diffusion propagator. Two solid matrices that are surrounded by an NMR-visible medium are considered: a hexagonal lattice of cylinders and a cubic lattice of triangles.
△ Less
Submitted 7 May, 2013;
originally announced May 2013.
-
Diffusion Pore Imaging by Hyperpolarized Xenon-129 Nuclear Magnetic Resonance
Authors:
Tristan Anselm Kuder,
Peter Bachert,
Johannes Windschuh,
Frederik Bernd Laun
Abstract:
Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not…
▽ More
Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not be preserved. Here we demonstrate experimentally using the measurement technique which we have recently proposed theoretically that the shape of arbitrary closed pores can be imaged by diffusion acquisitions, which yield the phase information. For this purpose, we use hyperpolarized xenon gas in well-defined geometries. The signal can be collected from the whole sample which mainly eliminates the problem of vanishing signal at increasing resolution of conventional NMR imaging. This could be used to non-invasively gain structural information inaccessible so far such as pore or cell shapes, cell density or axon integrity.
△ Less
Submitted 6 December, 2012;
originally announced December 2012.
-
Diffusion pore imaging with generalized temporal gradient profiles
Authors:
Frederik Bernd Laun,
Tristan Anselm Kuder
Abstract:
In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore imaging. In this work we present a generalization of these previous results. We sho…
▽ More
In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore imaging. In this work we present a generalization of these previous results. We show that the specific temporal gradient profiles that were used so far are not unique as more general temporal diffusion gradient profiles may be used. These temporal gradient profiles may consist of any number of 'short' gradient pulses, which fulfil the short-gradient approximation. Additionally, 'long' gradient pulses of small amplitude may be present, which can be used to fulfil the rephasing condition for the complete profile. Some exceptions exist. For example, classical q-space gradients consisting of two short gradient pulses of opposite sign cannot be used as the phase information is lost due to the temporal antisymmetry of this profile.
△ Less
Submitted 7 May, 2013; v1 submitted 3 August, 2012;
originally announced August 2012.
-
NMR Based Diffusion Pore Imaging by Double Wave Vector Measurements
Authors:
Tristan Anselm Kuder,
Frederik Bernd Laun
Abstract:
In porous material research, one main interest of nuclear magnetic resonance (NMR) diffusion experiments is the determination of the exact shape of pores. It has been a longstanding ques-tion if this is achievable in principle. In this work, we present a method using short diffusion gradient pulses only, which is able to reveal the shape of arbitrary closed pores without rely-ing on a priori knowl…
▽ More
In porous material research, one main interest of nuclear magnetic resonance (NMR) diffusion experiments is the determination of the exact shape of pores. It has been a longstanding ques-tion if this is achievable in principle. In this work, we present a method using short diffusion gradient pulses only, which is able to reveal the shape of arbitrary closed pores without rely-ing on a priori knowledge. In comparison to former approaches, the method has reduced de-mands on relaxation times and allows for a more flexible NMR sequence design, since, for example, stimulated echoes can be used.
△ Less
Submitted 8 May, 2012;
originally announced May 2012.
-
Determination of the Defining Boundary in Nuclear Magnetic Resonance Diffusion Experiments
Authors:
Frederik Bernd Laun,
Tristan Anselm Kuder,
Wolfhard Semmler,
Bram Stieltjes
Abstract:
While nuclear magnetic resonance diffusion experiments are widely used to resolve structures confining the diffusion process, it has been elusive whether they can exactly reveal these structures. This question is closely related to X-ray scattering and to Kac's "hear the drum" problem. Although the shape of the drum is not "hearable", we show that the confining boundary of closed pores can indeed…
▽ More
While nuclear magnetic resonance diffusion experiments are widely used to resolve structures confining the diffusion process, it has been elusive whether they can exactly reveal these structures. This question is closely related to X-ray scattering and to Kac's "hear the drum" problem. Although the shape of the drum is not "hearable", we show that the confining boundary of closed pores can indeed be detected using modified Stejskal-Tanner magnetic field gradients that preserve the phase information and enable imaging of the average pore in a porous medium with a largely increased signal-to-noise ratio.
△ Less
Submitted 8 May, 2012; v1 submitted 23 September, 2010;
originally announced September 2010.