-
CERN AD/ELENA Antimatter Program
Authors:
R. Caravita,
A. Cridland Mathad,
J. S. Hangst,
M. Hori,
B. M. Latacz,
A. Obertelli,
P. Perez,
S. Ulmer,
E. Widmann
Abstract:
The CERN AD/ELENA Antimatter program studies the fundamental charge, parity, time (CPT) reversal invariance through high-precision studies of antiprotons, antihydrogen, and antiprotonic atoms. Utilizing the world-unique Antiproton Decelerator (AD) and the Extra Low Energy Antiproton (ELENA) decelerator, the program supports multiple groundbreaking experiments aimed at testing fundamental symmetrie…
▽ More
The CERN AD/ELENA Antimatter program studies the fundamental charge, parity, time (CPT) reversal invariance through high-precision studies of antiprotons, antihydrogen, and antiprotonic atoms. Utilizing the world-unique Antiproton Decelerator (AD) and the Extra Low Energy Antiproton (ELENA) decelerator, the program supports multiple groundbreaking experiments aimed at testing fundamental symmetries, probing gravity with antimatter, and investigating potential asymmetric antimatter/dark matter interactions. Some experiments focus on precision spectroscopy of antihydrogen, while others conduct the most precise tests of CPT invariance in the baryon sector by comparing proton and antiproton properties. Other efforts are dedicated to measure the ballistic properties of antihydrogen under gravity and performing antiproton-based studies of neutron skins in exotic nuclei. These efforts have led to major breakthroughs, including the first trapped antihydrogen, antihydrogen's first gravitational acceleration measurement, and record-breaking precision CPT-tests in the baryon sector.
With continuous advancements in antimatter cooling, trapping, and transport, CERN's program is opening new frontiers in fundamental physics. Future goals, described in this document and reaching to timelines beyond 2040, include further improving the precision of antimatter studies, developing transportable antimatter traps, and advancing our understanding of quantum field theory, gravity, and dark matter interactions. Furthermore, new areas of hadron physics with antiprotons will be explored through studies of the Pontecorvo reaction, antineutron annihilation dynamics and hypernuclei decays. The CERN AD/ELENA Antimatter program remains at the forefront of experimental physics, pushing the limits of precision measurements to unravel the mysteries of the universe.
△ Less
Submitted 31 March, 2025; v1 submitted 28 March, 2025;
originally announced March 2025.
-
Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons
Authors:
B. M. Latacz,
M. Fleck,
J. I. Jaeger,
G. Umbrazunas,
B. P. Arndt,
S. R. Erlewein,
E. J. Wursten,
J. A. Devlin,
P. Micke,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we dem…
▽ More
We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.
△ Less
Submitted 11 April, 2024;
originally announced April 2024.
-
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
Authors:
C. Will,
M. Wiesinger,
P. Micke,
H. Yildiz,
T. Driscoll,
S. Kommu,
F. Abbass,
B. P. Arndt,
B. B. Bauer,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
A. Mooser,
D. Schweitzer,
G. Umbrazunas,
E. Wursten,
K. Blaum,
J. A. Devlin,
C. Ospelkaus,
W. Quint,
A. Soter,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a mileston…
▽ More
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Ultra thin polymer foil cryogenic window for antiproton deceleration and storage
Authors:
B. M. Latacz,
B. P. Arndt,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. I. Jäger,
P. Micke,
G. Umbrazunas,
E. Wursten,
F. Abbass,
D. Schweitzer,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
C. Smorra,
A. Sótér,
W. Quint,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons thro…
▽ More
We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $μ$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.
△ Less
Submitted 24 August, 2023;
originally announced August 2023.
-
Trap-integrated fluorescence detection based on silicon photomultipliers in a cryogenic Penning trap
Authors:
Markus Wiesinger,
Florian Stuhlmann,
Matthew A. Bohman,
Peter Micke,
Christian Will,
Hüseyin Yildiz,
Fatma Abbass,
Bela P. Arndt,
Jack A. Devlin,
Stefan Erlewein,
Markus Fleck,
Julia I. Jäger,
Barbara M. Latacz,
Daniel Schweitzer,
Gilbertas Umbrazunas,
Elise Wursten,
Klaus Blaum,
Yasuyuki Matsuda,
Andreas Mooser,
Wolfgang Quint,
Anna Soter,
Jochen Walz,
Christian Smorra,
Stefan Ulmer
Abstract:
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at ro…
▽ More
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPM) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically-sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1/s and a detection efficiency of 2.5(3) %. We further discuss the design of our cryogenic fluorescence-detection trap, and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our experiment.
△ Less
Submitted 4 August, 2023;
originally announced August 2023.
-
Production of antihydrogen atoms by 6 keV antiprotons through a positronium cloud
Authors:
P. Adrich,
P. Blumer,
G. Caratsch,
M. Chung,
P. Cladé,
P. Comini,
P. Crivelli,
O. Dalkarov,
P. Debu,
A. Douillet,
D. Drapier,
P. Froelich,
N. Garroum,
S. Guellati-Khelifa,
J. Guyomard,
P-A. Hervieux,
L. Hilico,
P. Indelicato,
S. Jonsell,
J-P. Karr,
B. Kim,
S. Kim,
E-S. Kim,
Y. J. Ko,
T. Kosinski
, et al. (39 additional authors not shown)
Abstract:
We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen productio…
▽ More
We report on the first production of an antihydrogen beam by charge exchange of 6.1 keV antiprotons with a cloud of positronium in the GBAR experiment at CERN. The antiproton beam was delivered by the AD/ELENA facility. The positronium target was produced from a positron beam itself obtained from an electron linear accelerator. We observe an excess over background indicating antihydrogen production with a significance of 3-4 standard deviations.
△ Less
Submitted 3 July, 2023; v1 submitted 27 June, 2023;
originally announced June 2023.
-
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Authors:
C. Smorra,
F. Abbass,
M. Bohman,
Y. Dutheil,
A. Hobl,
D. Popper,
B. Arndt,
B. B. Bauer,
J. A. Devlin,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
P. Micke,
M. Schiffelholz,
G. Umbrazunas,
M. Wiesinger,
C. Will,
E. Wursten,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
W. Quint
, et al. (4 additional authors not shown)
Abstract:
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To…
▽ More
Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE
Authors:
E. J. Wursten,
M. J. Borchert,
J. A. Devlin,
S. R. Erlewein,
M. Fleck,
J. A. Harrington,
J. I. Jäger,
B. M. Latacz,
P. Micke,
G. Umbrazunas,
F. Abbass,
M. Bohman,
S. Kommu,
D. Popper,
M. Wiesinger,
C. Will,
H. Yildiz,
K. Blaum,
Y. Matsuda,
A. Mooser,
C. Ospelkaus,
A. Soter,
W. Quint,
J. Walz,
Y. Yamazaki
, et al. (2 additional authors not shown)
Abstract:
The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton cha…
▽ More
The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.
△ Less
Submitted 1 February, 2023;
originally announced February 2023.
-
Positron accumulation in the GBAR experiment
Authors:
P. Blumer,
M. Charlton,
M. Chung,
P. Clade,
P. Comini,
P. Crivelli,
O. Dalkarov,
P. Debu,
L. Dodd,
A. Douillet,
S. Guellati,
P. -A Hervieux,
L. Hilico,
P. Indelicato,
G. Janka,
S. Jonsell,
J. -P. Karr,
B. H. Kim,
E. S. Kim,
S. K. Kim,
Y. Ko,
T. Kosinski,
N. Kuroda,
B. M. Latacz,
B. Lee
, et al. (45 additional authors not shown)
Abstract:
We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), whic…
▽ More
We present a description of the GBAR positron (e+) trapping apparatus, which consists of a three stage Buffer Gas Trap (BGT) followed by a High Field Penning Trap (HFT), and discuss its performance. The overall goal of the GBAR experiment is to measure the acceleration of the neutral antihydrogen (H) atom in the terrestrial gravitational field by neutralising a positive antihydrogen ion (H+), which has been cooled to a low temperature, and observing the subsequent H annihilation following free fall. To produce one H+ ion, about 10^10 positrons, efficiently converted into positronium (Ps), together with about 10^7 antiprotons (p), are required. The positrons, produced from an electron linac-based system, are accumulated first in the BGT whereafter they are stacked in the ultra-high vacuum HFT, where we have been able to trap 1.4(2) x 10^9 positrons in 1100 seconds.
△ Less
Submitted 9 May, 2022;
originally announced May 2022.