-
First constraints on the coherent elastic scattering of reactor antineutrinos off xenon nuclei
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovstsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase emission detector with an active volume containing 126~kg of liquid xenon. The detector was exposed to the antineutrino flux of about $1.4 \cdot 10^{13}~$cm$^{-2}$s$^{-1}$ at a distance of 19~m from the 3.1~GW Kalinin Nuclear Power Plant (KNPP) reactor core. The comparison of data from 331~kg$\cdot$days with the reactor on and 106~kg$\cdot$days with the reactor off shows no…
▽ More
RED-100 is a two-phase emission detector with an active volume containing 126~kg of liquid xenon. The detector was exposed to the antineutrino flux of about $1.4 \cdot 10^{13}~$cm$^{-2}$s$^{-1}$ at a distance of 19~m from the 3.1~GW Kalinin Nuclear Power Plant (KNPP) reactor core. The comparison of data from 331~kg$\cdot$days with the reactor on and 106~kg$\cdot$days with the reactor off shows no statistically significant excess and allows to put constraints on coherent elastic interactions of antineutrinos with xenon nuclei.
△ Less
Submitted 25 November, 2024;
originally announced November 2024.
-
First detection of coherent elastic neutrino-nucleus scattering on germanium
Authors:
S. Adamski,
M. Ahn,
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
N. Cedarblade-Jones,
J. Colón Rivera,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller
, et al. (62 additional authors not shown)
Abstract:
We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization…
▽ More
We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6$_{+7.1}^{-6.3}$ counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Calibration and characterization of the RED-100 detector at the Kalinin nuclear power plant
Authors:
D. Yu. Akimov,
I. S. Aleksandrov,
F. B. Ata Kurbonova,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
Yu. I. Koskin,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy recons…
▽ More
RED-100 is a two-phase Xe detector designed and built for the study of coherent elastic neutrino-nucleus scattering CEvNS of reactor antineutrinos. A comprehensive calibration was performed in order to obtain important parameters of the detector during its exposition at the Kalinin Nuclear Power Plant (Tver, Russia). This paper describes the analysis of calibration data, position and energy reconstruction procedures, and evaluation of the efficiency of electron extraction from the liquid xenon to the gas phase.
△ Less
Submitted 31 October, 2024; v1 submitted 19 March, 2024;
originally announced March 2024.
-
Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS
Authors:
P. S. Barbeau,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
E. Conley,
V. da Silva,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
A. Erlandson,
L. Fabris,
M. Febbraro,
A. Galindo-Uribarri,
M. P. Green,
J. Hakenmüller,
M. R. Heath,
S. Hedges,
B. A. Johnson
, et al. (55 additional authors not shown)
Abstract:
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We…
▽ More
We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.
△ Less
Submitted 21 November, 2023;
originally announced November 2023.
-
Characterization of the ambient background in the RED-100 experiment location at Kalinin Nuclear Power Plant
Authors:
D. Y. Akimov,
I. S. Alexandrov,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
Yu. V. Gusakov,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
B. O. Lavrov,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper descr…
▽ More
The RED-100 experiment with a liquid xenon target was carried out at Kalinin Nuclear Power Plant. The goal of the experiment is the detection and study of the coherent elastic neutrino nucleus scattering process (CE$ν$NS) for the low-energy antineutrinos in close vicinity to a reactor core. A good understanding of the external radioactive background is needed to achieve this goal. This paper describes the external background conditions for the RED-100 experiment at Kalinin Nuclear Power Plant.
△ Less
Submitted 24 November, 2023; v1 submitted 1 November, 2023;
originally announced November 2023.
-
Microwave Spin-Pumping from an Antiferromagnet FeBO3
Authors:
David Gabrielyan,
Dmitry Volkov,
Elizabeth Kozlova,
Ansar Safin,
Dmitry Kalyabin,
Alexey Klimov,
Vladimir Preobrazhensky,
Mark Strugatsky,
Sergey Yagupov,
Ivan Moskal,
Gennady Ovsyannikov,
Sergey Nikitov
Abstract:
Recently, canted antiferromagnets offer great potential for fundamental research and applications due to their unique properties. The presence of the Dzyaloshinskii-Moriya interaction leads to the existence of a weak ferromagnetic moment at room temperature. We study both theoretically and experimentally microwave spin pumping by the quasi-ferromagnetic mode from a canted easy plane antiferromagne…
▽ More
Recently, canted antiferromagnets offer great potential for fundamental research and applications due to their unique properties. The presence of the Dzyaloshinskii-Moriya interaction leads to the existence of a weak ferromagnetic moment at room temperature. We study both theoretically and experimentally microwave spin pumping by the quasi-ferromagnetic mode from a canted easy plane antiferromagnet with weak ferromagnetism FeBO3. The conversion of a microwave signal into the constant voltage is realized using the inverse spin Hall effect in an iron borate/heavy metal heterostructure. We use an additional bias magnetic field to selectively tune the resonance frequency of such a microwave detector over a wide range up to 43.5 GHz with potential sensitivity near 2.5 microV/W. We confirm the pure spin current nature by changing polarity of the detected via inverse spin Hall effect voltage by switching the direction of the bias magnetic field. We believe that our results will be useful for the development of highly tunable, portable and sensitive microwave antiferromagnet-based functional devices.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (53 additional authors not shown)
Abstract:
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the…
▽ More
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.
△ Less
Submitted 14 July, 2023;
originally announced July 2023.
-
Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector
Authors:
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
A. Brown,
J. Browning,
B. Cabrera-Palmer,
M. Cervantes,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
A. C. Germer
, et al. (64 additional authors not shown)
Abstract:
Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measureme…
▽ More
Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.
△ Less
Submitted 7 March, 2024; v1 submitted 31 May, 2023;
originally announced May 2023.
-
Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source
Authors:
COHERENT Collaboration,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
S. W. Belling,
V. Belov,
I. Bernardi,
C. Bock,
A. Bolozdynya,
R. Bouabid,
A. Brown,
J. Browning,
B. Cabrera-Palmer,
M. Cervantes,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso
, et al. (62 additional authors not shown)
Abstract:
Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is…
▽ More
Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.
△ Less
Submitted 30 October, 2023; v1 submitted 21 December, 2022;
originally announced December 2022.
-
A Review of NEST Models for Liquid Xenon and Exhaustive Comparison to Other Approaches
Authors:
M. Szydagis,
J. Balajthy,
G. A. Block,
J. P. Brodsky,
E. Brown,
J. E. Cutter,
S. J. Farrell,
J. Huang,
A. C. Kamaha,
E. S. Kozlova,
C. S. Liebenthal,
D. N. McKinsey,
K. McMichael,
R. McMonigle,
M. Mooney,
J. Mueller,
K. Ni,
G. R. C. Rischbieter,
K. Trengove,
M. Tripathi,
C. D. Tunnell,
V. Velan,
S. Westerdale,
M. D. Wyman,
Z. Zhao
, et al. (1 additional authors not shown)
Abstract:
This paper will discuss the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describe experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background will be presented using the Noble Element Simulation Technique (NEST),…
▽ More
This paper will discuss the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describe experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background will be presented using the Noble Element Simulation Technique (NEST), which is a toolkit based on experimental data and simple, empirical formulae, which mimic previous microphysics modeling, but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field will be reviewed, as well as models for energy resolution and final pulse areas. NEST will be compared to other models or sets of models, and vetted against real data, with several specific examples pulled from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.
△ Less
Submitted 19 December, 2024; v1 submitted 19 November, 2022;
originally announced November 2022.
-
The RED-100 experiment
Authors:
D. Yu. Akimov,
I. S. Alexandrov,
R. R. Alyev,
V. A. Belov,
A. I. Bolozdynya,
A. V. Etenko,
A. V. Galavanov,
E. M. Glagovsky,
Y. V. Gusakov,
A. V. Khromov,
S. M. Kiselev,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
A. V. Pinchuk,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
A. A. Vasin
Abstract:
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is des…
▽ More
The RED-100 two-phase xenon emission detector has been deployed at 19-m distance from the reactor core of the Kalinin Nuclear Power Plant (KNPP) in 2021 - 2022 for investigation of the possibility to observe reactor antineutrinos using the effect of coherent elastic neutrino-nucleus scattering (CEνNS). The performance of the main systems of the RED-100 setup at operating nuclear power plant is described. There is no correlation of the radioactive background at the experimental setup site with ON and OFF states of the reactor. The data taking run was carried out at the beginning of the year 2022 and covered both the reactor OFF and ON periods.
△ Less
Submitted 14 November, 2022; v1 submitted 30 September, 2022;
originally announced September 2022.
-
A COHERENT constraint on leptophobic dark matter using CsI data
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
R. Bouabid,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliot,
L. Fabris,
M. Febbraro,
A. Gallo Rosso
, et al. (56 additional authors not shown)
Abstract:
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV…
▽ More
We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV/c$^2$. No evidence for dark matter is observed and a limit on the mediator coupling to quarks is placed. This constraint improves upon previous results by two orders of magnitude. This newly explored parameter space probes the region where the dark matter relic abundance is explained by leptophobic dark matter when the mediator mass is roughly twice the dark matter mass. COHERENT sets the best constraint on leptophobic dark matter at these masses.
△ Less
Submitted 26 May, 2022; v1 submitted 24 May, 2022;
originally announced May 2022.
-
The COHERENT Experimental Program
Authors:
D. Akimov,
S. Alawabdeh,
P. An,
A. Arteaga,
C. Awe,
P. S. Barbeau,
C. Barry,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
C. Bock,
B. Bodur,
A. Bolozdynya,
R. Bouabid,
A. Bracho,
J. Browning,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Daughtry,
E. Day
, et al. (106 additional authors not shown)
Abstract:
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies o…
▽ More
The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.
△ Less
Submitted 9 April, 2022;
originally announced April 2022.
-
Monitoring the SNS basement neutron background with the MARS detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (53 additional authors not shown)
Abstract:
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the…
▽ More
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.
△ Less
Submitted 14 April, 2022; v1 submitted 5 December, 2021;
originally announced December 2021.
-
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (52 additional authors not shown)
Abstract:
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at t…
▽ More
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
△ Less
Submitted 6 October, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
First Probe of Sub-GeV Dark Matter Beyond the Cosmological Expectation with the COHERENT CsI Detector at the SNS
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (51 additional authors not shown)
Abstract:
The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent ela…
▽ More
The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6~kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants $α_D<0.64$, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.
△ Less
Submitted 14 February, 2023; v1 submitted 21 October, 2021;
originally announced October 2021.
-
Measurement of the Coherent Elastic Neutrino-Nucleus Scattering Cross Section on CsI by COHERENT
Authors:
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri,
M. P. Green
, et al. (51 additional authors not shown)
Abstract:
We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systemat…
▽ More
We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT collaboration determined the cross section to be $(165^{+30}_{-25})\times10^{-40}$~cm$^2$, consistent with the standard model, giving the most precise measurement of \cevns{} yet. The timing structure of the neutrino beam has been exploited to compare the \cevns{} cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino non-standard interactions while testing lepton flavor universality and measures the weak mixing angle as $\sin^2θ_{W}=0.220^{+0.028}_{-0.026}$ at $Q^2\approx(50\text{ MeV})^2$
△ Less
Submitted 2 June, 2022; v1 submitted 14 October, 2021;
originally announced October 2021.
-
Simulating the neutrino flux from the Spallation Neutron Source for the COHERENT experiment
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
C. Bock,
A. Bolozdynya,
J. Browning,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
J. Galambos,
A. Gallo Rosso
, et al. (58 additional authors not shown)
Abstract:
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 sim…
▽ More
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 simulation of neutrino production at the SNS and the flux calculation which informs the COHERENT studies. We estimate the uncertainty of this calculation at about 10% based on validation against available low-energy pion production data.
△ Less
Submitted 29 March, 2022; v1 submitted 22 September, 2021;
originally announced September 2021.
-
A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
D. Chernyak,
E. Conley,
J. Daughhetee,
E. Day,
J. Detwiler,
K. Ding,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
A. Gallo Rosso,
A. Galindo-Uribarri
, et al. (54 additional authors not shown)
Abstract:
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncerta…
▽ More
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.
△ Less
Submitted 25 August, 2021; v1 submitted 19 April, 2021;
originally announced April 2021.
-
A Review of Basic Energy Reconstruction Techniques in Liquid Xenon and Argon Detectors for Dark Matter and Neutrino Physics Using NEST
Authors:
M. Szydagis,
G. A. Block,
C. Farquhar,
A. J. Flesher,
E. S. Kozlova,
C. Levy,
E. A. Mangus,
M. Mooney,
J. Mueller,
G. R. C. Rischbieter,
A. K. Schwartz
Abstract:
Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (Weakly Interacting Massive Particles or WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret ex…
▽ More
Detectors based upon the noble elements, especially liquid xenon as well as liquid argon, as both single- and dual-phase types, require reconstruction of the energies of interacting particles, both in the field of direct detection of dark matter (Weakly Interacting Massive Particles or WIMPs, axions, etc.) and in neutrino physics. Experimentalists, as well as theorists who reanalyze/reinterpret experimental data, have used a few different techniques over the past few decades. In this paper, we review techniques based on solely the primary scintillation channel, the ionization or secondary channel available at non-zero drift electric fields, and combined techniques that include a simple linear combination and weighted averages, with a brief discussion of the applications of profile likelihood, maximum likelihood, and machine learning. Comparing results for electron recoils (beta and gamma interactions) and nuclear recoils (primarily from neutrons) from the Noble Element Simulation Technique (NEST) simulation to available data, we confirm that combining all available information generates higher-precision means, lower widths (energy resolution), and more symmetric shapes (approximately Gaussian) especially at keV-scale energies, with the symmetry even greater when thresholding is addressed. Near thresholds, bias from upward fluctuations matters. For MeV-GeV scales, if only one channel is utilized, an ionization-only-based energy scale outperforms scintillation; channel combination remains beneficial. We discuss here what major collaborations use.
△ Less
Submitted 21 March, 2021; v1 submitted 19 February, 2021;
originally announced February 2021.
-
Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
I. Bernardi,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr i…
▽ More
We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV
△ Less
Submitted 27 January, 2021; v1 submitted 21 October, 2020;
originally announced October 2020.
-
COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox
, et al. (58 additional authors not shown)
Abstract:
Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data c…
▽ More
Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.
△ Less
Submitted 29 July, 2020; v1 submitted 22 June, 2020;
originally announced June 2020.
-
First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
L. Blokland,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
D. Chernyak,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox
, et al. (58 additional authors not shown)
Abstract:
We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7)…
▽ More
We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.
△ Less
Submitted 15 February, 2021; v1 submitted 23 March, 2020;
originally announced March 2020.
-
Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter
Authors:
COHERENT Collaboration,
D. Akimov,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
N. Chen,
E. Conley,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. R. Durand,
Y. Efremenko,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri,
M. P. Green,
K. S. Hansen
, et al. (53 additional authors not shown)
Abstract:
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitu…
▽ More
The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
First ground-level laboratory test of the two-phase xenon emission detector RED-100
Authors:
D. Yu. Akimov,
V. A. Belov,
A. I. Bolozdynya,
Yu. V. Efremenko,
A. V. Etenko,
A. V. Galavanov,
D. V. Gouss,
Yu. V. Gusakov,
Dj. Ed. Kdib,
A. V. Khromov,
A. M. Konovalov,
V. N. Kornoukhov,
A. G. Kovalenko,
E. S. Kozlova,
A. V. Kumpan,
A. V. Lukyashin,
Yu. A. Melikyan,
V. V. Moramzin,
O. E. Razuvaeva,
D. G. Rudik,
A. V. Shakirov,
G. E. Simakov,
V. V. Sosnovtsev,
Yu. V. Stogov,
A. A. Vasin
Abstract:
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamats…
▽ More
RED-100 is a two-phase detector for study of coherent elastic scattering of reactor electron antineutrinos off xenon atomic nuclei. The detector contains a total of 200 kg of liquid xenon in a titanium cryostat with 160 kg of xenon in active volume inside a Teflon-made light collection cage associated with electrode system. The active volume is viewed by two arrays of nineteen 3"-diameter Hamamatsu R11410-20 PMTs assembled in two planes on top and bottom. The electrode system is equipped with an electron shutter (a patented device) to reduce a "spontaneous" single-electron noise. The detector was tested in a ground-level laboratory. The obtained results demonstrate that detection of coherent elastic scattering of reactor antineutrinos off xenon nuclei at Kalinin nuclear power plant with the RED-100 detector is feasible with a threshold of 4 ionization electrons.
△ Less
Submitted 14 October, 2019;
originally announced October 2019.
-
First Constraint on Coherent Elastic Neutrino-Nucleus Scattering in Argon
Authors:
COHERENT Collaboration,
D. Akimov,
J. B. Albert,
P. An,
C. Awe,
P. S. Barbeau,
B. Becker,
V. Belov,
M. A. Blackston,
A. Bolozdynya,
B. Cabrera-Palmer,
M. Cervantes,
J. I. Collar,
R. L. Cooper,
J. Daughhetee,
M. del Valle Coello,
J. A. Detwiler,
M. D'Onofrio,
Y. Efremenko,
E. M. Erkela,
S. R. Elliott,
L. Fabris,
M. Febbraro,
W. Fox,
A. Galindo-Uribarri
, et al. (55 additional authors not shown)
Abstract:
Coherent elastic neutrino-nucleus scattering (CEvNS) is the dominant neutrino scattering channel for neutrinos of energy $E_ν< 100$ MeV. We report a limit for this process using data collected in an engineering run of the 29 kg CENNS-10 liquid argon detector located 27.5 m from the Oak Ridge National Laboratory Spallation Neutron Source (SNS) Hg target with $4.2\times 10^{22}$ protons on target. T…
▽ More
Coherent elastic neutrino-nucleus scattering (CEvNS) is the dominant neutrino scattering channel for neutrinos of energy $E_ν< 100$ MeV. We report a limit for this process using data collected in an engineering run of the 29 kg CENNS-10 liquid argon detector located 27.5 m from the Oak Ridge National Laboratory Spallation Neutron Source (SNS) Hg target with $4.2\times 10^{22}$ protons on target. The dataset yielded $< 7.4$ observed CEvNS events implying a cross section for the process, averaged over the SNS pion decay-at-rest flux, of $<3.4 \times 10^{-39}$ cm$^{2}$, a limit within twice the Standard Model prediction. This is the first limit on CEvNS from an argon nucleus and confirms the earlier CsI non-standard neutrino interaction constraints from the collaboration. This run demonstrated the feasibility of the ongoing experimental effort to detect CEvNS with liquid argon.
△ Less
Submitted 12 September, 2019;
originally announced September 2019.
-
VISON: An Ontology-Based Approach for Software Visualization Tool Discoverability
Authors:
Leonel Merino,
Ekaterina Kozlova,
Oscar Nierstrasz,
Daniel Weiskopf
Abstract:
Although many tools have been presented in the research literature of software visualization, there is little evidence of their adoption. To choose a suitable visualization tool, practitioners need to analyze various characteristics of tools such as their supported software concerns and level of maturity. Indeed, some tools can be prototypes for which the lifespan is expected to be short, whereas…
▽ More
Although many tools have been presented in the research literature of software visualization, there is little evidence of their adoption. To choose a suitable visualization tool, practitioners need to analyze various characteristics of tools such as their supported software concerns and level of maturity. Indeed, some tools can be prototypes for which the lifespan is expected to be short, whereas others can be fairly mature products that are maintained for a longer time. Although such characteristics are often described in papers, we conjecture that practitioners willing to adopt software visualizations require additional support to discover suitable visualization tools. In this paper, we elaborate on our efforts to provide such support. To this end, we systematically analyzed research papers in the literature of software visualization and curated a catalog of 70 available tools that employ various visualization techniques to support the analysis of multiple software concerns. We further encapsulate these characteristics in an ontology. VISON, our software visualization ontology, captures these semantics as concepts and relationships. We report on early results of usage scenarios that demonstrate how the ontology can support (i) developers to find suitable tools for particular development concerns, and (ii) researchers who propose new software visualization tools to identify a baseline tool for a controlled experiment.
△ Less
Submitted 12 August, 2019;
originally announced August 2019.
-
Nonstoichiometric titanium dioxide nanotubes with enhanced catalytical activity under visible light
Authors:
A. A. Valeeva,
E. A. Kozlova,
A. S. Vokhmintsev,
R. V. Kamalov,
I. B. Dorosheva,
A. A. Saraev,
I. A. Weinstein,
A. A. Rempel
Abstract:
The catalytic activity of nanotubular titanium dioxide films formed during the oxidation of acetone to carbon dioxide under the action of visible light with a wavelength of 450 nm was found to be approximately 2 times higher compared to standard titanium dioxide (Degussa P25). The nanotubular films were grown by the anodization of titanium foil using an original technique. Diffuse reflectance spec…
▽ More
The catalytic activity of nanotubular titanium dioxide films formed during the oxidation of acetone to carbon dioxide under the action of visible light with a wavelength of 450 nm was found to be approximately 2 times higher compared to standard titanium dioxide (Degussa P25). The nanotubular films were grown by the anodization of titanium foil using an original technique. Diffuse reflectance spectra of the films are attributed to enhanced activity in the visible spectrum by the nonstoichiometry of titanium dioxide near the interface between the nanotubular film and the titanium foil substrate.
△ Less
Submitted 14 June, 2019;
originally announced June 2019.
-
Effect of the temperature and magnetic field induced martensitic transformation in bulk Fe$_{45}$Mn$_{26}$Ga$_{29}$ alloy on its electronic structure and physical properties
Authors:
Y. V. Kudryavtsev,
N. V. Uvarov,
A. E. Perekos,
J. Dubowik,
L. E. Kozlova
Abstract:
Effect of the temperature and magnetic field induced martensitic transformation (MT) on the electronic structure and some physical properties of bulk Fe$_{45.2}$Mn$_{25.9}$Ga$_{28.9}$ Heusler alloy has been investigated. {According to the experimental results of DSC, magnetic and transport measurements direct and reverse martensitic transformation without external magnetic field takes place within…
▽ More
Effect of the temperature and magnetic field induced martensitic transformation (MT) on the electronic structure and some physical properties of bulk Fe$_{45.2}$Mn$_{25.9}$Ga$_{28.9}$ Heusler alloy has been investigated. {According to the experimental results of DSC, magnetic and transport measurements direct and reverse martensitic transformation without external magnetic field takes place within 194 $\leq T \leq$ 328 K temperature range with a hysteresis up to $ΔT \approx$ 100 K defined as $ΔT$ = $A_{f,s}$ - $M_{s,f}$, where $A_{f,s}$ and $M_{s,f}$ are the critical temperatures of direct and reverse martensitic transformation. External magnetic field of $μ_{0}H$ = 5 T causes a high-temperature shift of MT temperatures.} MT from parent austenite L2$_{1}$ phase to martensitic tetragonally distorted L2$_{1}$ one (i. e. to L1$_{0}$) causes significant changes in the electronic structure of alloy, a drastic increase in alloy magnetization, a decrease in the alloy resistivity, and a reversal of the sign of the temperature coefficient of resistivity from negative to positive. At the same time experimentally determined optical properties of Fe$_{45.6}$Mn$_{25.9}$Ga$_{28.9}$ Heusler alloy in austenitic and martensitic states look visually rather similar being noticeable different in microscopic nature as can be concluded from first-principle calculations. Experimentally observed changes in the physical properties of the alloy are discussed in terms of the electronic structures of an austenite and martensite phases.
△ Less
Submitted 20 February, 2019;
originally announced February 2019.
-
Properties of the lunar exosphere during the perseid 2009 meteor shower
Authors:
A. A. Berezhnoy,
K. I. Churyumov,
V. V. Kleshchenok,
E. A. Kozlova,
V. Mangano,
Yu. V. Pakhomov,
V. O. Ponomarenko,
V. V. Shevchenko,
Yu. I. Velikodsky
Abstract:
Influence of the meteoroid bombardment on properties of the lunar exosphere has been confirmed. Quick increase in the zenith column density of Na atoms above the lunar north pole on August 13, 2009 at 0-1 UT is detected and explained by numerous collisions of relatively small Perseid meteoroids (< 1 kg) with the Moon during maximum of the Perseid meteor shower. New stringent upper limits of the co…
▽ More
Influence of the meteoroid bombardment on properties of the lunar exosphere has been confirmed. Quick increase in the zenith column density of Na atoms above the lunar north pole on August 13, 2009 at 0-1 UT is detected and explained by numerous collisions of relatively small Perseid meteoroids (< 1 kg) with the Moon during maximum of the Perseid meteor shower. New stringent upper limits of the column densities for Ca, Ba, and Ti atoms in the lunar exosphere are obtained as 5*10^7, 2.2*10^6, and 6.9*10^8 cm^-2, respectively. It is found that the content of impact-produced Ca and Al atoms in the lunar exosphere is depleted as compared to that of Na atoms.
△ Less
Submitted 8 April, 2014;
originally announced April 2014.