-
Sterile-neutrino search based on 259 days of KATRIN data
Authors:
Himal Acharya,
Max Aker,
Dominic Batzler,
Armen Beglarian,
Justus Beisenkötter,
Matteo Biassoni,
Benedikt Bieringer,
Yanina Biondi,
Matthias Böttcher,
Beate Bornschein,
Lutz Bornschein,
Marco Carminati,
Auttakit Chatrabhuti,
Suren Chilingaryan,
Deseada Díaz Barrero,
Byron A. Daniel,
Martin Descher,
Otokar Dragoun,
Guido Drexlin,
Frank Edzards,
Klaus Eitel,
Enrico Ellinger,
Ralph Engel,
Sanshiro Enomoto,
Luca Fallböhmer
, et al. (110 additional authors not shown)
Abstract:
Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial role in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, reveals that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact…
▽ More
Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial role in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, reveals that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact via the weak force. The KATRIN experiment, primarily designed to measure the neutrino mass via tritium $β$-decay, also searches for sterile neutrinos suggested by these anomalies. A sterile-neutrino signal would appear as a distortion in the $β$-decay energy spectrum, characterized by a discontinuity in curvature (kink) related to the sterile-neutrino mass. This signature, which depends only on the shape of the spectrum rather than its absolute normalization, offers a robust, complementary approach to reactor experiments. KATRIN examined the energy spectrum of 36 million tritium $β$-decay electrons recorded in 259 measurement days within the last 40 electronvolt below the endpoint. The results exclude a substantial part of the parameter space suggested by the gallium anomaly and challenge the Neutrino-4 claim. Together with other neutrino-disappearance experiments, KATRIN probes sterile-to-active mass splittings from a fraction of an electron-volt squared to several hundred electron-volts squared, excluding light sterile neutrinos with mixing angles above a few percent.
△ Less
Submitted 24 March, 2025;
originally announced March 2025.
-
Measurement of the inhomogeneity of the KATRIN tritium source electric potential by high-resolution spectroscopy of conversion electrons from $^{83m}$Kr
Authors:
H. Acharya,
M. Aker,
D. Batzler,
A. Beglarian,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
M. Descher,
D. Díaz Barrero,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel,
S. Enomoto
, et al. (108 additional authors not shown)
Abstract:
Precision spectroscopy of the electron spectrum of the tritium $β$-decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than 0.3$\,$eV (90$\,$% C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to di…
▽ More
Precision spectroscopy of the electron spectrum of the tritium $β$-decay near the kinematic endpoint is a direct method to determine the effective electron antineutrino mass. The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to determine this quantity with a sensitivity of better than 0.3$\,$eV (90$\,$% C.L.). An inhomogeneous electric potential in the tritium source of KATRIN can lead to distortions of the $β$-spectrum, which directly impact the neutrino-mass observable. This effect can be quantified through precision spectroscopy of the conversion-electrons of co-circulated metastable $^{83m}$Kr. Therefore, dedicated, several-weeks long measurement campaigns have been performed within the KATRIN data taking schedule. In this work, we infer the tritium source potential observables from these measurements, and present their implications for the neutrino-mass determination.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
Comparison of the detector response and calibration function of metallic microcalorimeters for X-ray photons and external electrons
Authors:
Neven Kovac,
Fabienne Adam,
Sebastian Kempf,
Marie-Christin Langer,
Michael Müller,
Rudolf Sack,
Magnus Schlösser,
Markus Steidl,
Kathrin Valerius
Abstract:
Metallic microcalorimeters (MMCs) are cryogenic single-particle detectors that rely on a calorimetric detection principle. Due to their excellent energy resolution, close-to-ideal linear detector response, fast signal rise time and the potential for \SI{100}{\%} quantum efficiency, MMCs outperform conventional detectors by several orders of magnitude in resolution. These attributes make them parti…
▽ More
Metallic microcalorimeters (MMCs) are cryogenic single-particle detectors that rely on a calorimetric detection principle. Due to their excellent energy resolution, close-to-ideal linear detector response, fast signal rise time and the potential for \SI{100}{\%} quantum efficiency, MMCs outperform conventional detectors by several orders of magnitude in resolution. These attributes make them particularly interesting for a broad spectrum of applications, including a next-generation neutrino mass experiment based on the measurement of the tritium beta-decay spectrum, with an objective of achieving a sensitivity surpassing that of the pioneering KATRIN experiment. However, although MMCs have been used in measurements of photons and heavy ions with great success, no information is currently available on the interaction between MMCs and external light charged particles such as electrons. This work aims to provide such missing information and to demonstrate that MMC-based detectors are suitable for high-resolution spectroscopy of external electron sources. Particularly, we present the first-ever measurements of external electrons using a metallic microcalorimeter, comprehensively discuss the characteristics of the signal shape and the calibration function and give a direct comparison between well-defined conversion electron and X-ray photon signals from the same $^{83}$Rb/$^{83m}$Kr source.
△ Less
Submitted 9 February, 2025;
originally announced February 2025.
-
First constraints on general neutrino interactions based on KATRIN data
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
B. Bornschein,
L. Bornschein,
M. Böttcher,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards,
K. Eitel,
E. Ellinger,
R. Engel,
S. Enomoto
, et al. (108 additional authors not shown)
Abstract:
The precision measurement of the tritium $β$-decay spectrum performed by the KATRIN experiment provides a unique way to search for general neutrino interactions (GNI). All theoretical allowed GNI terms involving neutrinos are incorporated into a low-energy effective field theory, and can be identified by specific signatures in the measured tritium $β$-spectrum. In this paper an effective descripti…
▽ More
The precision measurement of the tritium $β$-decay spectrum performed by the KATRIN experiment provides a unique way to search for general neutrino interactions (GNI). All theoretical allowed GNI terms involving neutrinos are incorporated into a low-energy effective field theory, and can be identified by specific signatures in the measured tritium $β$-spectrum. In this paper an effective description of the impact of GNI on the $β$-spectrum is formulated and the first constraints on the effective GNI parameters are derived based on the 4 million electrons collected in the second measurement campaign of KATRIN in 2019. In addition, constraints on selected types of interactions are investigated, thereby exploring the potential of KATRIN to search for more specific new physics cases, including a right-handed W boson, a charged Higgs or leptoquarks.
△ Less
Submitted 12 November, 2024; v1 submitted 14 October, 2024;
originally announced October 2024.
-
Measurement of the electric potential and the magnetic field in the shifted analysing plane of the KATRIN experiment
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
S. Bobien,
M. Böttcher,
B. Bornschein,
L. Bornschein,
T. S. Caldwell,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards
, et al. (113 additional authors not shown)
Abstract:
The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after five years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN's main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The co…
▽ More
The projected sensitivity of the effective electron neutrino-mass measurement with the KATRIN experiment is below 0.3 eV (90 % CL) after five years of data acquisition. The sensitivity is affected by the increased rate of the background electrons from KATRIN's main spectrometer. A special shifted-analysing-plane (SAP) configuration was developed to reduce this background by a factor of two. The complex layout of electromagnetic fields in the SAP configuration requires a robust method of estimating these fields. We present in this paper a dedicated calibration measurement of the fields using conversion electrons of gaseous $^\mathrm{83m}$Kr, which enables the neutrino-mass measurements in the SAP configuration.
△ Less
Submitted 9 August, 2024;
originally announced August 2024.
-
Direct neutrino-mass measurement based on 259 days of KATRIN data
Authors:
M. Aker,
D. Batzler,
A. Beglarian,
J. Behrens,
J. Beisenkötter,
M. Biassoni,
B. Bieringer,
Y. Biondi,
F. Block,
S. Bobien,
M. Böttcher,
B. Bornschein,
L. Bornschein,
T. S. Caldwell,
M. Carminati,
A. Chatrabhuti,
S. Chilingaryan,
B. A. Daniel,
K. Debowski,
M. Descher,
D. Díaz Barrero,
P. J. Doe,
O. Dragoun,
G. Drexlin,
F. Edzards
, et al. (124 additional authors not shown)
Abstract:
The fact that neutrinos carry a non-vanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass bears important relevance from particle physics to cosmology. In this work, we report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium $β$-decay close to the…
▽ More
The fact that neutrinos carry a non-vanishing rest mass is evidence of physics beyond the Standard Model of elementary particles. Their absolute mass bears important relevance from particle physics to cosmology. In this work, we report on the search for the effective electron antineutrino mass with the KATRIN experiment. KATRIN performs precision spectroscopy of the tritium $β$-decay close to the kinematic endpoint. Based on the first five neutrino-mass measurement campaigns, we derive a best-fit value of $m_ν^{2} = {-0.14^{+0.13}_{-0.15}}~\mathrm{eV^2}$, resulting in an upper limit of $m_ν< {0.45}~\mathrm{eV}$ at 90 % confidence level. With six times the statistics of previous data sets, amounting to 36 million electrons collected in 259 measurement days, a substantial reduction of the background level and improved systematic uncertainties, this result tightens KATRIN's previous bound by a factor of almost two.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Development and characterisation of high-resolution microcalorimeter detectors for the ECHo-100k experiment
Authors:
Federica Mantegazzini,
Neven Kovac,
Christian Enss,
Andreas Fleischmann,
Markus Griedel,
Loredana Gastaldo
Abstract:
The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach thi…
▽ More
The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach this goal, a new generation of high-resolution magnetic microcalorimeters with embedded Ho-163 have been developed and characterised. The design has been optimised to meet all the challenging requirements of the ECHo-100k experimental phase, such as excellent energy resolution, wafer scale implantation and multi-chip operation with multiplexing read-out. We present the optimisation studies, the final design of the detector array and the first characterisation studies. The results demonstrate that the detectors fully match and even surpass the requirements for the current experimental phase, ECHo-100k.
△ Less
Submitted 24 July, 2023; v1 submitted 16 January, 2023;
originally announced January 2023.
-
Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment
Authors:
F. Mantegazzini,
A. Barth,
H. Dorrer,
Ch. E. Düllmann,
C. Enss,
A. Fleischmann,
R. Hammann,
S. Kempf,
T. Kieck,
N. Kovac,
C. Velte,
M. Wegner,
K. Wendt,
T. Wickenhäuser,
L. Gastaldo
Abstract:
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has…
▽ More
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stopping power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Piezospectroscopy and first-principles calculations of the nitrogen-vacancy center in gallium arsenide
Authors:
Nicola Kovač,
Christopher Künneth,
Hans Christian Alt
Abstract:
The nitrogen-vacancy (NV) center occurs in GaAs bulk crystals doped or implanted with nitrogen. The local vibration of nitrogen gives rise to a sharp infrared absorption band at 638 cm$^{-1}$, exhibiting a fine structure due to the different masses of neighboring $^{69}$Ga and $^{71}$Ga host isotopes. Piezospectroscopic investigations in the crystallographic <100> direction prove that the center h…
▽ More
The nitrogen-vacancy (NV) center occurs in GaAs bulk crystals doped or implanted with nitrogen. The local vibration of nitrogen gives rise to a sharp infrared absorption band at 638 cm$^{-1}$, exhibiting a fine structure due to the different masses of neighboring $^{69}$Ga and $^{71}$Ga host isotopes. Piezospectroscopic investigations in the crystallographic <100> direction prove that the center has C$_\text{3v}$ point symmetry, which is weakly perturbed by the isotope effect. The stress-induced shifts of some band components show an unusual non-linear behavior that can be explained by coupling between the isotope and the stress splitting. First-principles density-functional theory calculations are in full accordance with the experiments and confirm the C$_\text{3v}$ symmetry, caused by relaxation of the nitrogen atom from the anion lattice site towards the nearest-neighbor Ga plane. The NV center in GaAs is structurally analogous to the same center in diamond. The $-3$ charge state is most stable for nearly all Fermi-level positions.
△ Less
Submitted 6 February, 2018; v1 submitted 29 October, 2017;
originally announced October 2017.