-
Superstability of micrometer jets surrounded by a polymeric shell
Authors:
A. Rubio,
J. M. Montanero,
M. Vakili,
F. H. M. Koua,
S. Bajt,
H. N. Chapman,
A. M. Gañán-Calvo
Abstract:
We have produced superstable compound liquid microjets with a three-dimensional printed coaxial flow-focusing injector. The aqueous jet core is surrounded by a shell, a few hundred nanometers in thickness, of a low-concentration aqueous solution of a low-molecular-weight polymer. Due to the stabilizing effect of the polymeric shell, the minimum liquid flow rate leading to stable flow-focusing is d…
▽ More
We have produced superstable compound liquid microjets with a three-dimensional printed coaxial flow-focusing injector. The aqueous jet core is surrounded by a shell, a few hundred nanometers in thickness, of a low-concentration aqueous solution of a low-molecular-weight polymer. Due to the stabilizing effect of the polymeric shell, the minimum liquid flow rate leading to stable flow-focusing is decreased by one order of magnitude, resulting in much thinner and longer jets. Possible applications of this technique for Serial Femtosecond X-ray Crystallography are discussed.
△ Less
Submitted 27 May, 2025;
originally announced May 2025.
-
3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers
Authors:
Patrick E. Konold,
Tong You,
Johan Bielecki,
Joana Valerio,
Marco Kloos,
Daniel Westphal,
Alfredo Bellisario,
Tej Varma,
August Wolter,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Romain Letrun,
Adam Round,
Tokushi Sato,
Petra Mésźaros,
Leonardo Monrroy,
Jennifer Mutisya,
Szabolcs Bódizs,
Taru Larkiala,
Amke Nimmrich,
Roberto Alvarez,
Richard Bean,
Tomas Ekeberg,
Richard A. Kirian,
Sebastian Westenhoff
, et al. (1 additional authors not shown)
Abstract:
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a b…
▽ More
X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Ultrasound cavitation and exfoliation dynamics of 2D materials re-vealed in operando by X-ray free electron laser megahertz imaging
Authors:
Kang Xiang,
Shi Huang,
Hongyuan Song,
Vasilii Bazhenov,
Valerio Bellucci,
Sarlota Birnsteinova,
Raphael de Wijn,
Jayanath C. P. Koliyadu,
Faisal H. M. Koua,
Adam Round,
Ekaterina Round,
Abhisakh Sarma,
Tokushi Sato,
Marcin Sikorski,
Yuhe Zhang,
Eleni Myrto Asimakopoulou,
Pablo Villanueva-Perez,
Kyriakos Porfyrakis,
Iakovos Tzanakis,
Dmitry G. Eskin,
Nicole Grobert,
Adrian Mancuso,
Richard Bean,
Patrik Vagovic,
Jiawei Mi
Abstract:
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simul…
▽ More
Ultrasonic liquid phase exfoliation is a promising method for the production of two-dimensional (2D) layered materials. A large number of studies have been made in investigating the underlying ultrasound exfoliation mechanisms. However, due to the experimental challenges for capturing the highly transient and dynamic phenomena in real-time at sub-microsecond time and micrometer length scales simultaneously, most theories reported to date still remain elusive. Here, using the ultra-short X-ray Free Electron Laser pulses (~25ps) with a unique pulse train structure, we applied MHz X-ray Microscopy and machine-learning technique to reveal unambiguously the full cycles of the ultrasound cavitation and graphite layer exfoliation dynamics with sub-microsecond and micrometer resolution. Cyclic fatigue shock wave impacts produced by ultrasound cloud implosion were identified as the dominant mechanism to deflect and exfoliate graphite layers mechanically. For the graphite flakes, exfoliation rate as high as ~5 angstroms per shock wave impact was observed. For the HOPG graphite, the highest exfoliation rate was ~0.15 angstroms per impact. These new findings are scientifically and technologically important for developing industrial upscaling strategies for ultrasonic exfoliation of 2D materials.
△ Less
Submitted 23 June, 2023; v1 submitted 15 May, 2023;
originally announced May 2023.