-
The quality assurance test of the SliT ASIC for the J-PARC muon $g-2$/EDM experiment
Authors:
Takashi Yamanaka,
Yoichi Fujita,
Eitaro Hamada,
Tetsuichi Kishishita,
Tsutomu Mibe,
Yutaro Sato,
Yoshiaki Seino,
Masayoshi Shoji,
Taikain Suehara,
Manobu M. Tanaka,
Junji Tojo,
Keisuke Umebayashi,
Tamaki Yoshioka
Abstract:
The SliT ASIC is a readout chip for the silicon strip detector to be used at the J-PARC muon $g-2$/EDM experiment. The production version of SliT128D was designed and mass production was finished. A quality assurance test method for bare SliT128D chips was developed to provide a sufficient number of chips for the experiment. The quality assurance test of the SliT128D chips was performed and 5735 c…
▽ More
The SliT ASIC is a readout chip for the silicon strip detector to be used at the J-PARC muon $g-2$/EDM experiment. The production version of SliT128D was designed and mass production was finished. A quality assurance test method for bare SliT128D chips was developed to provide a sufficient number of chips for the experiment. The quality assurance test of the SliT128D chips was performed and 5735 chips were inspected. No defect was observed in chips of 84.3%. Accepting a few channels with poor time walk performance out of 128 channels per chip, more than 90% yield can be achieved, which is sufficient to construct the whole detector.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC
Authors:
B. Aimard,
L. Aizawa,
C. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (138 additional authors not shown)
Abstract:
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passi…
▽ More
The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performances of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.
△ Less
Submitted 20 December, 2020; v1 submitted 16 October, 2020;
originally announced October 2020.
-
LTARS: Analog Readout Front-end ASIC for Versatile TPC-applications
Authors:
Tetsuichi Kishishita,
S. Sumomozawa,
T. Kosaka,
T. Igarashi,
K. Sakashita,
M. Shoji,
M. M. Tanaka,
T. Hasegawa,
K. Negishi,
S. Narita,
T. Nakamura,
K. Miuchi
Abstract:
We designed a versatile analog front-end chip, called LTARS, for TPC-applications, primarily targeted at dual-phase liquid Ar-TPCs for neutrino experiments and negative-ion $μ$-TPCs for directional dark matter searches. Low-noise performance and wide dynamic range are two requirements for reading out the signals induced on the TPC readout channels. One of the development objectives is to establish…
▽ More
We designed a versatile analog front-end chip, called LTARS, for TPC-applications, primarily targeted at dual-phase liquid Ar-TPCs for neutrino experiments and negative-ion $μ$-TPCs for directional dark matter searches. Low-noise performance and wide dynamic range are two requirements for reading out the signals induced on the TPC readout channels. One of the development objectives is to establish the analog processing circuits under low temperature operation, which are designed on function block basis as reusable IPs (Intellectual Properties). The newly developed ASIC was implemented in the Silterra 180~nm CMOS technology and has 16 readout channels. We carried out the performance test at room temperature and the results showed an equivalent noise charge of 2695$\pm$71~e$^-$ (rms) with a detector capacitance of 300~pF. The dynamic range was measured to be 20--100~fC in the low-gain mode and 200--1600~fC in the high-gain mode within 10\% integral nonlinearity at room temperature. We also tested the performance at the liquid-Ar temperature and found a deterioration of the noise level with a longer shaper time. Based on these results, we also discuss a unique simulation methodology for future cold-electronics development. This method can be applicable to design the electronics used at low temperature.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
SliT: A Strip-sensor Readout Chip with Subnanosecond Time-walk for the J-PARC Muon $g-2$/EDM Experiment
Authors:
Tetsuichi Kishishita,
Yutaro Sato,
Yoichi Fujita,
Eitaro Hamada,
Tsutomu Mibe,
Tsubasa Nagasawa,
Shohei Shirabe,
Masayoshi Shoji,
Taikan Suehara,
Manobu M. Tanaka,
Junji Tojo,
Yuki Tsutumi,
Takashi Yamanaka,
Tamaki Yoshioka
Abstract:
A new silicon-strip readout chip named "SliT" has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal integrated circuits. An analog circuit incorporates a conventional charge-sensitive amplifier, shaping amplifiers, and two distinct discriminators for each of 12…
▽ More
A new silicon-strip readout chip named "SliT" has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal integrated circuits. An analog circuit incorporates a conventional charge-sensitive amplifier, shaping amplifiers, and two distinct discriminators for each of 128 identical channels. A digital part includes storage memories, an event building block, a serializer, and LVDS drivers. A distinct feature of the SliT is utilization of the zero-cross architecture, which consists of a CR-RC filter followed by a CR circuit as a voltage differentiator. This architecture enables to generate hit signals with subnanosecond amplitude-independent time walk, which is the primary requirement for the experiment. The test results show the time walk of $0.38 \pm 0.16$ ns between 0.5 and 3 MIP signals. The equivalent noise charge is $1547 \pm 75 $ $e^{-}$ (rms) at $C_{\rm det} = 33$ pF as a strip-sensor capacitance. Other functionalities such as a strip-sensor readout chip have also been proven in the tests. The SliT128C satisfies all requirements of the J-PARC muon $g-2$/EDM experiment.
△ Less
Submitted 28 July, 2020; v1 submitted 14 June, 2020;
originally announced June 2020.
-
Prototype Front-end ASIC for Silicon-strip Detectors of J-PARC Muon g-2/EDM Experiment
Authors:
Yuki Tsutsumi,
Tetsuichi Kishishita,
Yutaro Sato,
Masayoshi Shoji,
Manobu M. Tanaka,
Tsutomu Mibe,
Junji Tojo
Abstract:
We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granular…
▽ More
We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8~ns with a sufficient dynamic range of 6~MIPs and pulse width of 45~ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.
△ Less
Submitted 29 January, 2019;
originally announced January 2019.
-
A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment
Authors:
M. Abe,
S. Bae,
G. Beer,
G. Bunce,
H. Choi,
S. Choi,
M. Chung,
W. da Silva,
S. Eidelman,
M. Finger,
Y. Fukao,
T. Fukuyama,
S. Haciomeroglu,
K. Hasegawa,
K. Hayasaka,
N. Hayashizaki,
H. Hisamatsu,
T. Iijima,
H. Iinuma,
K. Inami,
H. Ikeda,
M. Ikeno,
K. Ishida,
T. Itahashi,
M. Iwasaki
, et al. (71 additional authors not shown)
Abstract:
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon…
▽ More
This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.
△ Less
Submitted 10 March, 2019; v1 submitted 10 January, 2019;
originally announced January 2019.
-
Prototype Analog Front-end for Negative-ion Gas and Dual-phase Liquid-Ar TPCs
Authors:
Miki Nakazawa,
Tetsuichi Kishishita,
Masayoshi Shoji,
Ken Sakashita,
Tomonori Ikeda,
Hirohisa Ishiura,
James B. R. Battat,
Catherine Nicoloff,
Manobu M. Tanaka,
Takuya Hasegawa,
Kentaro Miuchi
Abstract:
We report on the recent development of a versatile analog front-end compatible with a negative-ion $μ$-TPC for a directional dark matter search as well as a dual-phase, next-generation $\mathcal{O}$(10~kt) liquid argon TPC to study neutrino oscillations, nucleon decay, and astrophysical neutrinos. Although the operating conditions for negative-ion and liquid argon TPCs are quite different (room te…
▽ More
We report on the recent development of a versatile analog front-end compatible with a negative-ion $μ$-TPC for a directional dark matter search as well as a dual-phase, next-generation $\mathcal{O}$(10~kt) liquid argon TPC to study neutrino oscillations, nucleon decay, and astrophysical neutrinos. Although the operating conditions for negative-ion and liquid argon TPCs are quite different (room temperature \textit{vs.} $\sim$88~K operation, respectively), the readout electronics requirements are similar. Both require a wide-dynamic range up to 1600 fC, and less than 2000--5000 e$^-$ noise for a typical signal of 80 fC with a detector capacitance of $C_{\rm det} \approx 300$~pF. In order to fulfill such challenging requirements, a prototype ASIC was newly designed using 180-nm CMOS technology. Here, we report on the performance of this ASIC, including measurements of shaping time, dynamic range, and equivalent noise charge (ENC). We also demonstrate the first operation of this ASIC on a low-pressure negative-ion $μ$-TPC.
△ Less
Submitted 8 January, 2019;
originally announced January 2019.
-
A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers
Authors:
B. Aimard,
Ch. Alt,
J. Asaadi,
M. Auger,
V. Aushev,
D. Autiero,
M. M. Badoi,
A. Balaceanu,
G. Balik,
L. Balleyguier,
E. Bechetoille,
D. Belver,
A. M. Blebea-Apostu,
S. Bolognesi,
S. Bordoni,
N. Bourgeois,
B. Bourguille,
J. Bremer,
G. Brown,
G. Brunetti,
L. Brunetti,
D. Caiulo,
M. Calin,
E. Calvo,
M. Campanelli
, et al. (147 additional authors not shown)
Abstract:
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kin…
▽ More
A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and oers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of 3x1x1 $m^3$ has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.
△ Less
Submitted 19 October, 2018; v1 submitted 8 June, 2018;
originally announced June 2018.
-
Charge collection properties in an irradiated pixel sensor built in a thick-film HV-SOI process
Authors:
B. Hiti,
V. Cindro,
A. Gorišek,
T. Hemperek,
T. Kishishita,
G. Kramberger,
H. Krüger,
I. Mandić,
M. Mikuž,
N. Wermes,
M. Zavrtanik
Abstract:
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiat…
▽ More
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiation. In this article we present results of an extensive irradiation hardness study with neutrons up to a fluence of 1x10e16 neq/cm2. Charge collection in a passive pixelated structure was measured by Edge Transient Current Technique (E-TCT). The evolution of the effective space charge concentration was found to be compliant with the acceptor removal model, with the minimum of the space charge concentration being reached after 5x10e14 neq/cm2. An investigation of the in-pixel uniformity of the detector response revealed parasitic charge collection by the epitaxial silicon layer characteristic for the SOI design. The results were backed by a numerical simulation of charge collection in an equivalent detector layout.
△ Less
Submitted 26 October, 2017; v1 submitted 23 January, 2017;
originally announced January 2017.
-
A Monolithic active pixel sensor for ionizing radiation using a 180nm HV-SOI process
Authors:
Tomasz Hemperek,
Tetsuichi Kishishita,
Hans Krüger,
Norbert Wermes
Abstract:
An improved SOI-MAPS (Silicon On Insulator Monolithic Active Pixel Sensor) for ionizing radiation based on thick-film High Voltage SOI technology (HV-SOI) has been developed. Similar to existing Fully Depleted SOI-based (FD-SOI) MAPS, a buried silicon oxide inter-dielectric (BOX) layer is used to separate the CMOS electronics from the handle wafer which is used as a depleted charge collection laye…
▽ More
An improved SOI-MAPS (Silicon On Insulator Monolithic Active Pixel Sensor) for ionizing radiation based on thick-film High Voltage SOI technology (HV-SOI) has been developed. Similar to existing Fully Depleted SOI-based (FD-SOI) MAPS, a buried silicon oxide inter-dielectric (BOX) layer is used to separate the CMOS electronics from the handle wafer which is used as a depleted charge collection layer. FD-SOI MAPS suffer from radiation damage such as transistor threshold voltage shifts due to charge traps in the oxide layers and charge states created at the silicon oxide boundaries (back gate effect). The X-FAB 180-nm HV-SOI technology offers an additional isolation by deep non-depleted implant between the BOX layer and the active circuitry witch mitigates this problem. Therefore we see in this technology a high potential to implement radiation-tolerant MAPS with fast charge collection property. The design and measurement results from a first prototype are presented including charge collection in neutron irradiated samples.
△ Less
Submitted 23 February, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
DMAPS: a fully depleted monolithic active pixel sensor - analog performance characterization
Authors:
Miroslav Havránek,
Tomasz Hemperek,
Hans Krüger,
Yunan Fu,
Leonard Germic,
Tetsuichi Kishishita,
Theresa Obermann,
Norbert Wermes
Abstract:
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s based on silicon substrates with a thin epitaxial layer (thickness of 10-15 $μ$m) in which charge is collected on an electrode, albeit by disordered and slow diffusion rather than by drift in a directed electric field. As a consequence, the signal is small ($\approx$ 1000 e$^-$) and the radiation tolerance is much belo…
▽ More
Monolithic Active Pixel Sensors (MAPS) have been developed since the late 1990s based on silicon substrates with a thin epitaxial layer (thickness of 10-15 $μ$m) in which charge is collected on an electrode, albeit by disordered and slow diffusion rather than by drift in a directed electric field. As a consequence, the signal is small ($\approx$ 1000 e$^-$) and the radiation tolerance is much below the LHC requirements by factors of 100 to 1000. In this paper we present the development of a fully Depleted Monolithic Active Pixel Sensors (DMAPS) based on a high resistivity substrate allowing the creation of a fully depleted detection volume. This concept overcomes the inherent limitations of charge collection by diffusion in the standard MAPS designs. We present results from a test chip EPCB01 designed in a commercial 150 nm CMOS technology. The technology provides a thin (50 $μ$m) high resistivity n-type silicon substrate as well as an additional deep p-well which allows to integrate full CMOS circuitry inside the pixel. Different matrix types with several variants of collection electrodes have been implemented. Measurements of the analog performance of this first implementation of DMAPS pixels will be presented.
△ Less
Submitted 2 July, 2014;
originally announced July 2014.
-
Nonthermal emission properties of the northwestern rim of supernova remnant RX J0852-4622
Authors:
Tetsuichi Kishishita,
Junko Hiraga,
Yasunobu Uchiyama
Abstract:
The supernova remnant (SNR) RX J0852-4622 (Vela Jr., G266.6-1.2) is one of the most important SNRs for investigating the acceleration of multi-TeV particles and the origin of Galactic cosmic rays because of its strong synchrotron X-ray and TeV gamma-ray emission, which show a shell-like morphology similar to each other. Using the XMM-Newton archival data consisting of multiple pointing observation…
▽ More
The supernova remnant (SNR) RX J0852-4622 (Vela Jr., G266.6-1.2) is one of the most important SNRs for investigating the acceleration of multi-TeV particles and the origin of Galactic cosmic rays because of its strong synchrotron X-ray and TeV gamma-ray emission, which show a shell-like morphology similar to each other. Using the XMM-Newton archival data consisting of multiple pointing observations of the northwestern rim of the remnant, we investigate the spatial properties of the nonthermal X-ray emission as a function of distance from an outer shock wave. All X-ray spectra are well reproduced by an absorbed power-law model above 2 keV. It is found that the spectra show gradual softening from a photon index 2.56 in the rim region to 2.96 in the interior region. We show that this radial profile can be interpreted as a gradual decrease of the cutoff energy of the electron spectrum due to synchrotron cooling. By using a simple spectral evolution model that includes continuous synchrotron losses, the spectral softening can be reproduced with the magnetic field strength in the post-shock flow to less than several tens of uG. If this is a typical magnetic field in the SNR shell, gamma-ray emission would be accounted for by inverse Compton scattering of high-energy electrons that also produce the synchrotron X-ray emission. Future hard X-ray imaging observations with Nustar and ASTRO-H and TeV gamma-ray observations with the Cherenkov Telescope Array (CTA) will allow to us to explore other possible explanations of the systematic softening of the X-ray spectra.
△ Less
Submitted 1 February, 2013;
originally announced February 2013.
-
X-ray investigation of the diffuse emission around plausible gamma-ray emitting pulsar wind nebulae in Kookaburra region
Authors:
Tetsuichi Kishishita,
Aya Bamba,
Yasunobu Uchiyama,
Yasuyuki Tanaka,
Tadayuki Takahashi
Abstract:
We report on the results from {\it Suzaku} X-ray observations of the radio complex region called Kookaburra, which includes two adjacent TeV $γ$-ray sources HESS J1418-609 and HESS J1420-607. The {\it Suzaku} observation revealed X-ray diffuse emission around a middle-aged pulsar PSR J1420-6048 and a plausible PWN Rabbit with elongated sizes of $σ_{\rm X}=1^{\prime}.66$ and…
▽ More
We report on the results from {\it Suzaku} X-ray observations of the radio complex region called Kookaburra, which includes two adjacent TeV $γ$-ray sources HESS J1418-609 and HESS J1420-607. The {\it Suzaku} observation revealed X-ray diffuse emission around a middle-aged pulsar PSR J1420-6048 and a plausible PWN Rabbit with elongated sizes of $σ_{\rm X}=1^{\prime}.66$ and $σ_{\rm X}=1^{\prime}.49$, respectively. The peaks of the diffuse X-ray emission are located within the $γ$-ray excess maps obtained by H.E.S.S. and the offsets from the $γ$-ray peaks are $2^{\prime}.8$ for PSR J1420-6048 and $4^{\prime}.5$ for Rabbit. The X-ray spectra of the two sources were well reproduced by absorbed power-law models with $Γ=1.7-2.3$. The spectral shapes tend to become softer according to the distance from the X-ray peaks. Assuming the one zone electron emission model as the first order approximation, the ambient magnetic field strengths of HESS J1420-607 and HESS J1418-609 can be estimated as 3 $μ$G, and $2.5 μ$G, respectively. The X-ray spectral and spatial properties strongly support that both TeV sources are pulsar wind nebulae, in which electrons and positrons accelerated at termination shocks of the pulsar winds are losing their energies via the synchrotron radiation and inverse Compton scattering as they are transported outward.
△ Less
Submitted 26 March, 2012;
originally announced March 2012.
-
Long-term Stability of Non-thermal X-ray Modulation in the Gamma-ray Binary LS 5039
Authors:
Tetsuichi Kishishita,
Takaaki Tanaka,
Yasunobu Uchiyama,
Tadayuki Takahashi
Abstract:
We report on long-term stability of X-ray modulation apparently synchronized with an orbital period of 3.9 days in the gamma-ray binary LS 5039. Recent observations with the Suzaku satellite in the year 2007, which covered continuously more than one orbital period, have provided us with detailed characterization of X-ray flux and spectral shape as a function of orbital phase. Motivated by the re…
▽ More
We report on long-term stability of X-ray modulation apparently synchronized with an orbital period of 3.9 days in the gamma-ray binary LS 5039. Recent observations with the Suzaku satellite in the year 2007, which covered continuously more than one orbital period, have provided us with detailed characterization of X-ray flux and spectral shape as a function of orbital phase. Motivated by the results from Suzaku, we have re-analyzed the X-ray data obtained with ASCA, XMM-Newton, and Chandra between 1999 and 2005, to investigate long-term behavior of LS 5039 in the X-ray band.
We found that the modulation curves in 1999--2007 are surprisingly stable. Even fine structures in the light curves such as spikes and dips are found to be quite similar from one orbit to another. The spectral characteristics observed in the past are consistent with those seen with Suzaku for some orbital phase segments. We suggest that magneto-hydrodynamical collisions between the relativistic outflow from a compact object and the stellar wind from the O star explain the clock-like non-thermal X-ray emission over eight years through remarkably stable production of high-energy particles near the binary system.
△ Less
Submitted 19 June, 2009; v1 submitted 7 April, 2009;
originally announced April 2009.
-
Study of the Spectral and Temporal Characteristics of X-Ray Emission of the Gamma-Ray Binary LS 5039 with Suzaku
Authors:
T. Takahashi,
T. Kishishita,
Y. Uchiyama,
T. Tanaka,
K. Yamaoka,
D. Khangulyan,
F. A. Aharonian,
V. Bosch-Ramon,
J. A. Hinton
Abstract:
We report on the results from Suzaku broadband X-ray observations of the galactic binary source LS5039. The Suzaku data, which have continuous coverage of more than one orbital period, show strong modulation of the X-ray emission at the orbital period of this TeV gamma-ray emitting system.The X-ray emission shows a minimum at orbital phase ~ 0.1, close to the so-called superior conjunction of th…
▽ More
We report on the results from Suzaku broadband X-ray observations of the galactic binary source LS5039. The Suzaku data, which have continuous coverage of more than one orbital period, show strong modulation of the X-ray emission at the orbital period of this TeV gamma-ray emitting system.The X-ray emission shows a minimum at orbital phase ~ 0.1, close to the so-called superior conjunction of the compact object, and a maximum at phase ~0.7, very close to the inferior conjunction of the compact object. The X-ray spectral data up to 70 keV are described by a hard power-law with a phase-dependent photon index which varies within Gamma ~1.45 - 1.61. The amplitude of the flux variation is a factor of 2.5, but is significantly less than that of the factor ~8 variation in the TeV flux. Otherwise the two light curves are similar, but not identical. Although periodic X-ray emission has been found from many galactic binary systems, the Suzaku result implies a phenomenon different from the "standard" origin of X-rays related to the emission of the hot accretion plasma formed around the compact companion object. The X-ray radiation of LS5039is likely to be linked to very-high-energy electrons which are also responsible for the TeV gamma-ray emission. While the gamma-rays are the result of inverse Compton scattering by electrons on optical stellar photons, X-rays are produced via synchrotron radiation. Yet, while the modulation of the TeV gamma-ray signal can be naturally explained by the photon-photon pair production and anisotropic inverse Compton scattering, the observed modulation of synchrotron X-rays requires an additional process, the most natural one being adiabatic expansion in the radiation production region.
△ Less
Submitted 26 April, 2009; v1 submitted 17 December, 2008;
originally announced December 2008.
-
Study of Nonthermal Emission from SNR RX J1713.7-3946 with Suzaku
Authors:
Takaaki Tanaka,
Yasunobu Uchiyama,
Felix A. Aharonian,
Tadayuki Takahashi,
Aya Bamba,
Junko S. Hiraga,
Jun Kataoka,
Tetsuichi Kishishita,
Motohide Kokubun,
Koji Mori,
Kazuhiro Nakazawa,
Robert Petre,
Hiroyasu Tajima,
Shin Watanabe
Abstract:
We present results obtained from a series of observations of the supernova remnant RX J1713.7-3946 by the Suzaku satellite. The observations cover about two-thirds of the remnant surface. We successfully detected hard X-rays up to ~ 40 keV from each pointing. The hard X-ray spectra are described by power-law functions with photon indices of ~ 3.0, which are larger than those in the energy region…
▽ More
We present results obtained from a series of observations of the supernova remnant RX J1713.7-3946 by the Suzaku satellite. The observations cover about two-thirds of the remnant surface. We successfully detected hard X-rays up to ~ 40 keV from each pointing. The hard X-ray spectra are described by power-law functions with photon indices of ~ 3.0, which are larger than those in the energy region below 10 keV. Connection of the spatially-integrated XIS and HXD spectra clearly reveals a spectral cutoff in the 0.4--40 keV X-ray spectrum. This cutoff is interpreted to correspond to the maximum acceleration energy of electrons emitting synchrotron radiation. The wide-band coverage of Suzaku for the first time allows us to derive the parent electron spectrum in the cutoff region, which shows good agreement with theoretical predictions. The inferred cutoff energy in the spatially-integrated X-ray spectrum indicates that particle acceleration in the remnant is so efficient that it is almost at the theoretical limit, the so-called Bohm limit. Based on the Suzaku data, we present results of multi-wavelength studies from spectral and morphological points of view. The spectral energy distribution favors the hadronic scenario rather than the leptonic scenario. For the morphology studies, we compare the surface brightness maps from the Suzaku XIS and the H.E.S.S. telescope. We confirm the strong correlation between X-ray and TeV gamma-ray emission. In addition to the correlation, we found that in the bright western rim regions the X-ray emission is brighter than expected from the general X-ray to gamma-ray correlation.
△ Less
Submitted 9 June, 2008;
originally announced June 2008.
-
In-Orbit Performance of the Hard X-ray Detector on board Suzaku
Authors:
M. Kokubun,
K. Makishima,
T. Takahashi,
T. Murakami,
M. Tashiro,
Y. Fukazawa,
T. Kamae,
G. M. Madejski,
K. Nakazawa,
K. Yamaoka,
Y. Terada,
D. Yonetoku,
S. Watanabe,
T. Tamagawa,
T. Mizuno,
A. Kubota,
N. Isobe,
I. Takahashi,
G. Sato,
H. Takahashi,
S. Hong,
M. Kawaharada,
N. Kawano,
T. Mitani,
M. Murashima
, et al. (32 additional authors not shown)
Abstract:
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of P…
▽ More
The in-orbit performance and calibration of the Hard X-ray Detector (HXD) on board the X-ray astronomy satellite Suzaku are described. Its basic performances, including a wide energy bandpass of 10-600 keV, energy resolutions of ~4 keV (FWHM) at 40 keV and ~11% at 511 keV, and a high background rejection efficiency, have been confirmed by extensive in-orbit calibrations. The long-term gains of PIN-Si diodes have been stable within 1% for half a year, and those of scintillators have decreased by 5-20%. The residual non-X-ray background of the HXD is the lowest among past non-imaging hard X-ray instruments in energy ranges of 15-70 and 150-500 keV. We provide accurate calibrations of energy responses, angular responses, timing accuracy of the HXD, and relative normalizations to the X-ray CCD cameras using multiple observations of the Crab Nebula.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.
-
Hard X-ray Detector (HXD) on Board Suzaku
Authors:
T. Takahashi,
K. Abe,
M. Endo,
Y. Endo,
Y. Ezoe,
Y. Fukazawa,
M. Hamaya,
S. Hirakuri,
S. Hong,
M. Horii,
H. Inoue,
N. Isobe,
T. Itoh,
N. Iyomoto,
T. Kamae,
D. Kasama,
J. Kataoka,
H. Kato,
M. Kawaharada,
N. Kawano,
K. Kawashima,
S. Kawasoe,
T. Kishishita,
T. Kitaguchi,
Y. Kobayashi
, et al. (44 additional authors not shown)
Abstract:
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the…
▽ More
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from 10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators. The HXD is designed to achieve an extremely low in-orbit back ground based on a combination of new techniques, including the concept of well-type active shield counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV, the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2} keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for the phoswich counter. Tight active shielding of the HXD results in a large array of guard counters surrounding the main detector parts. These anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large effective area for sub-MeV to MeV gamma-rays. They work as an excellent gamma-ray burst monitor with limited angular resolution (~5 degree). The on-board signal-processing system and the data transmitted to the ground are also described.
△ Less
Submitted 7 November, 2006;
originally announced November 2006.