Exposing nanobubble-like objects to a degassed environment
Authors:
Robin P. Berkelaar,
Erik Dietrich,
Gerard A. M. Kip,
E. Stefan Kooij,
Harold J. W. Zandvliet,
Detlef Lohse
Abstract:
The primary attribute of interest of surface nanobubbles is their unusual stability and a number of theories trying to explain this have been put forward. Interestingly, the dissolution of nanobubbles is a topic that did not receive a lot of attention yet. In this work we applied two different experimental procedures which should cause gaseous nanobubbles to completely dissolve. In our experiments…
▽ More
The primary attribute of interest of surface nanobubbles is their unusual stability and a number of theories trying to explain this have been put forward. Interestingly, the dissolution of nanobubbles is a topic that did not receive a lot of attention yet. In this work we applied two different experimental procedures which should cause gaseous nanobubbles to completely dissolve. In our experiments we nucleated nanobubble-like objects by putting a drop of water on HOPG using a plastic syringe and disposable needle. In method A, the nanobubble-like objects were exposed to a flow of degassed water (1.17 mg/l) for 96 hours. In method B, the ambient pressure was lowered in order to degas the liquid and the nanobubble-like objects. Interestingly, the nanobubble-like objects remained stable after exposure to both methods. After thorough investigation of the procedures and materials used during our experiments, we found that the nanobubble-like object were induced by the use of disposable needles in which PDMS contaminated the water. It is very important for the nanobubble community to be aware of the fact that, although features look and behave like nanobubbles, in some cases they might in fact be or induced by contamination. The presence of contamination could also resolve some inconsistencies found in the nanobubble literature.
△ Less
Submitted 24 May, 2016;
originally announced May 2016.
Round Robin: Quantitative Lateral Resolution of PHI XPS microprobes Quantum 2000 / Quantera SXM
Authors:
U. Scheithauer,
M. Kolb,
G. A. M. Kip,
E. Naburgh,
J. H. M. Snijders
Abstract:
The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitati…
▽ More
The quantitative lateral resolution is a reliable measure for the quality of an XPS microprobe equipped with a focused X-ray beam. It describes the long tail contributions of the X-ray beam intensity distribution. The knowledge of these long tail contributions is essential when judging on the origin of signals of XPS spectra recorded on small-sized features. In this round robin test the quantitative lateral resolution of 7 PHI XPS microprobes has been estimated. As expected, the quantitative lateral resolution has significantly larger values than the nominal X-ray beam diameter. The estimated values of the quantitative lateral resolution follow a trend in time: The newer the monochromator of an XPS microprobe so much the better the quantitative lateral resolution.
△ Less
Submitted 9 May, 2016;
originally announced May 2016.